Loading...
HomeMy WebLinkAboutConstruction PlansI I 1 12'-7Yz' I. 12'-0" 1. Plan View PILING NOTES 0TOP OF 8' PILING — 6' ABOVE DECK ELEVATION 0TOP OF 8' PILING — 3' ABOVE DECK ELEVATION Q TOP OF 8' PILING — UNDER DECK ELEVATION CONTRACTOR NOTES 1. PLANKED DECKING: MINIMUM 1/2' GAP 2. TERMINAL SIZE: 160 SO. FT. 3. DECKING HEIGHT: MINIMUM 5' ABOVE MHW/OHW 4. PILING INSTALLATION: LOW PRESSURE PUMP JETTING MANGROVE NOTES 1. THE WIDTH OF THE PILING —SUPPORTED STRUCTURE ENTRY IS LIMITED TO A MAXIMUM OF 4 FEET. 2. THE LOCATION AND ALIGNMENT OF THE PILING — SUPPORTED STRUCTURE IS THROUGH THE NARROWEST AREA OF THE MANGROVE FRINGE 3. THE PROPOSED LOCATION OF THE DOCK STRUCTURE AVOIDS ALTERING ANY EXISTING MANGROVE. JOHNSON'S SEAGRASS NOTES 1. A JOHNSON'S SEAGRASS INSPECTION WAS PER— FORMED BY RON A. DEGRAZIA ON 04/09/20. 2. NO JOHNSON'S SEAGRASS WAS OBSERVED. 24' MAX. SPAN : DOCK ENTRY LOCATED DaSITNG MANGROVE OPENING 1�1�71 I I 0 mI 0 I C4 N 38'-0" PROPERTY FRONTAGE RESIDENCE -§OVEIRUDE9�0RCFt — i— co mKns w4s*o a s N03004!01eWt 28.53' Lj n Zia J }I l I — Of EXISTING WIDE 0.-I DOCK & C); BOAT LIFT 0-1 oI I— I U' w' 01 i e of l m= 1 TABULATION 725 s,f. EXISTING DOCK 375 s,f. PROPOSED DOCK 350 s,f, NET REDUCTION DESIGN CRITERIA (FBC 2017 WIND SPEED - 16OMPH Vult RISK CATEGORY - I EXPOSURE = D ENCLOSURE OPEN IMPORTANCE FACTOR gCE7) - 0.77 RESULTANT WIND PRESSURE - 40.96 PSF HANDRAIL LOAD o. 50PLF = 200LB CONCENTRATED INTERMEDIATE RAILS - 50 LB ON 15F AREA MATERIALS SPECIFICATIONS WOOD: ALL WOOD MEMBERS SHALL BE NO.2 OR BETTER SOUTHERN YELLOW PINE (UNLESS OTHERWISE SPECIFIED). PRESSURE TREATED IN ACCORDANCE WITH THE A.W.PA STANDARD C-18 FOR MARINE CONSTRUCTION. THE PRESERVATIVE USED SHALL BE A WATERBORNE TYPE SUCH AS 'B' OR 'C' AS COVERED IN FEDERAL SPEC. Tr—W-535, AND A.W.PA STANDARDS P5, C2, AND C14. ALL WOOD TO BE STRAIGHT. TRUE, AND FREE FROM SPLINTS, WANE OR OTHER OBJECTIONABLE DEFECTS. BOLT HOLES SHALL BE DRILLED TO THE BOLT DIAMETER AND THEN HAMMERED INTO PLACE PILINGS SHALL BE TREATED WITH NOT LESS THAN 2.5 LBS./C.F. OF C.CA PRESERVATIVE SALTS IN WITH A.W.PA STANDARD C-18. 60 PSF Total Loud 40 PSF Live Load #10 x 3' STAINLESS -STEEL DECK SCREWS 20 PSF Dmd Load 2 PER DECK BOARD AT EACH STRINGER` 10 x 3' STAINLESS -STEEL SCREWS PER EACH STRINGER/PILING CONNECTION REVIEWED FOR ODE COMPLIANCE T. LUCIE COUNTY BOCC Typical Dock Detail PROPOSED DOCK & BOAT LIFT Site Plan / Survey 7,000# BOAT LIFT PROFILE 12' MAX. SPAN f z 1. rd W LS' x 5.5' 'Narb* Deck' P/T DECKING r/I/Z' GAP 2 x 8 P/T STRINGER 5/8' STAINLESS -STEEL ALL -THREAD r/NUT/WASHER EACH END 2 x 8 P/T BENT TYP. 8' MARINE GRADE PILINGS ■ Pilings set to 6' minimum enbednent KNIGHT, McGUIRE &ASSOCIATES, INC. CONSULTING ENGINEERS AND PLANNERS 80 ROYAL PALM POINTE, SUITE 401 VERO BEACH, FL 32960 PHONE: (772) 569-5505 FAX: (772) 569-1455 CERTIFICATE OF AUTHORIZATION NUMBER — 00006335 Vero Dock,Baade Dock 5313 Montego Circle, Ft. Pierce, FL 34949 s DATE.- DATE. 2 2 2020A Scott B. McGuire, P.E. David S. Knight, P.E. Fl. Reg No. 39573 Fl. Reg No. 41060 CORE Marine Contractors, Inc. P. 0. Box 643711 Vero Beach, FL 32964 772.234.4228 Phone 888.858.1492 Fax /—E /—H / 1 /_G u K C A g Equal Equal 1 B L ` Plan View Scale: 3/8" = 1'.0�'T""�,,, J�N 1 g 2019; • P••�tcENs ,.% l _ AID. -)3 = IF 91 MAY 12 320 ST. Lucie County, General Notes: • Design in accordance with Florida Building Code, 6th Edition (2017). • This lifting structure has been designed to withstand wind foods associated with speeds of V (ult) = 180 MPH, (3 Second Gust) Exposure 'D' without a boat on the lift per ASCE 7-10 using above ground sign/wall method. The lifting structure including boat has been designed to withstand wind speeds of V (ult) = 73 MPH in Exposure V. • Boats shall not be stored on lift during high wind events. • Do not scale drawings for dimensions. • Licensed Contractor to verify location of existing utilities prior to commencing work. • The Licensed contractor to install and remove all shoring and bracing as required for the proper installation of the work. • Licensed Contractor to obtain all permits as necessary from all Local, State, and Federal agencies. • Aluminum: Material 6061 T6 Aluminum, all welds are min. }° full fillet weld using 5556 filler alloy, all welding must conform to AISC steel construction manual 14th ED as inspected and verified by others. The contractor is responsible to insulate aluminum members from dissimilar metals, to prevent electrolysis. • Aluminum members in contact with concrete and wood shall be protected by 'Koppers Bituminous Paint` or Polyethylene Tape UHMW (ultra high molecular weight). 11.7 mils (0.30 mm) min. total thickness in accordance with current Florida Building Code. • All anchors to be MIN Brand br Approved Equal. All bolts shall be hot dipped galvanized or stainless steel & meet the requirements of ASTM A304 with hardened washers and hex nuts. Washers shall be used between wood & bolt head & between wood & nqt. Where generic fasteners are labeled in details, capacities shall be equal to or greater than Hilti Kwik Bolt 11 or Red Head thru bolts SAE Grade 5 or better. Embedment depths specified herein are depths into solid substrate and do not included thickness of other finishes. • MW Engineering has no control of the manufacturing, performance or installation of this product. These generic plans were engineered in accordance with accepted engineering practices and data provided by the manufacturer. • Ptles shall be dnven to refusal and suffiaently penetrated into sand or rock strata to LU support lift capacity, weight and loads. • Each pile to carry commensurate load LE 1/4th lift capacity for 4—post lift (Factor of CC Z Safety of 1.5) 0 Z • Allowable minimum compression pile capacity of 5 tons. J O • The contractor of record shall verify pile type, installation and driving in compliance with ®a V FBC 6th ED (2017) UJ • Sub —surface conditions can vary greatly. 0u1 W .. Ll, 4 _ DATE NOTES REVISIONS NOT VALIDVA%9ff SIGTJEtSW �; s� 32 ORIGINAL ENja R'�IGNATURE : <c,. MW, ENGINEERING, INC Proposed 4 - Post Boat Lifts NEPTUNE BOAT LIFTS ten:: o5.,2so,s 01/07/2018 Changed FBC Note A��RID P,.� ��: 902 NE 1 Street Suite DRAWN 9r: wRT � / C �: 4,500 Ib 228 SW 21 Terrace '•�NAL EN .�` Pompano Beach, Florida 33060 t� Fort Lauderdale, Florida 33312 wccKEo BY. wn, �4'"""'�V . Ofc: 754-333-0877 Phone: 954-524-3616 •oe No: o.at•r 32.awg MARK E. WEBER, P.E. WM.MWEn meerin 24,000Ib ' LICENSE #53895 1 CA 30702 9 9•flet Fax:954-524-3604 Sheet 1 of 3 , I , Typical -Cross Section A —A scale. -JIB" = ,11=0" , „nnrrrrr �•��CENSF�A J No.53895 iupport Pile typical) (2) J"0 Wedge Anchors Into Concrete Piles 4" Minimum Embedment (2) J10 Lag Bolts Into Wood Piles 4" Minimum Embedment enter Line of Ile (Typical) 0.50"0 5" W , 12" p V , 5 1 ® Q LL=® 4--v —4r w 2 LU c' O Mounting Bracket Detail w v 0° ' , - W O DATE NOTES REVISIONS NOT VALID Sasssr NGNAt6kL� ORIGINAL ENOINEEfYiS SI AND FPAl p S • ,ORtD•. NAL - �� MW, ENGINEERING, INC 902 NE 1 Street Suite#2 �`�� Pompano Beach, Florida 33060 Ofc: 754-333-0877 WWW.MwEn In g� eering.net Proposed 4 - Post Boat Lifts p 4,500 Ib t0 24 000 lb � NEPTUNE BOAT LIFTS 228 SW 21 Terrace Fort. Lauderdale, Florida 33312 Phone: 954-524-3616 Fax:954-524-3604 SCALE: 32 0110712018 Changed FBC Note DATE: 05.12.2015 DRAWN BY wRT CHECKED BY. WM „r, . MARK E.38951C 3 LICENSE#538951 CA 30702 MS No: Ovotor 3Zdwq Sheet 2 of 3 C Center rem/a. u Typical Cross Section B—B Scale: J/8" = 1'=0" JUN 1 6 2019 PRK E. 14 •�LICF4, at N •I 389p e ?J A B C D E F G H I J K L M BUNK NOTE: Or Aluminum Equivalent with Protective Cap Components Lift Capacity (In Pounds) 4,500 1 7,000 1 10,000 13,000 1 16,000 1 20,000 24,000 Bunk WKS" Pressure Treated Southern Yellow Pine #1 - See Bunk Note 3"x10" Pressure Treated Southern Yellow Pine #1 - See Bunk Note 3"x12" PT SYP #1 Bunk Bracket Support a^x2g2" ' Lifter Beam AA 16"x4.7 AA 18'7c(3.3 AA 18"x7.0 AA 1 10"z10.3 AA 117)(11.91 Sheave Pulley Plate kx4"x5" Angle Cable Size (Stainless Steel) {6" Diameter 7x19 SS 304^ (1 Part) Diameter 7x19 SS 304 (2 Part) is" Diameter 7x19 SS 304 (3 Part) Piling Mounting Bracket J"x3"x12" Flat Bar Carrier Beam End Plate n"x5" Flat Bar }"x6" Flat Bar } x7" Flat Bar J"x5" Flat Bar Drive Shaft Bearing Block 2"x3" Flat Bar Drive Shaft 1-1/2" Nominal Diameter Schedule 80 Galvanized Pipe Top Carrier Assembly 2 C-Channels Per Assembly 5 AA CS 5"x2.2 AA CS 6"x2.8 AA CS 7"x3.2 AA CS 8"x4.3 AA CS 8"x5.79 Motor Size (Horse PowerNoltage) Top Carrier Connector j"x3"x12" Flat Bar Guide Post Socket 2" Nominal Diameter Schedule 80 Aluminum Pipe 0 � V L L _ ... V LU �w L L�96�im LU LU ^� E GATE NOTES REVISIONS NOT VALID UNL•E N D F ORIGINAL ENGIK SiJATURE AND �R)p �• = ,, .MW ENGINEERING INC ; \\,�= 902 NE 1 Street Suite #2 Pompano Beach, Florida 33060 '� _ Ofc: 754-333-0877 WWW.MwEngineering.net Proposed 4 - Post Boat Lifts P 4,500 Ib to 24,000 Ib NEPTUNE BOAT LIFTS 228 SW 21 Terrace Fort Lauderdale, Florida 33312 � Phone: 954-524-3616 Fax: 954-524-3604 SCALE E' 3 01/07/2018 Changed FBC Note DATE W2RT- 15 DRAWN BY: CHECKED BY: WM MARK E. WEBER, E. P.E." LICENSE#538951 CA 30702 JOB No: Elw"t"r 72ewg Sheet 3 of 3