Loading...
HomeMy WebLinkAboutConstruction Plans— —�---- — I O27 r 27 27 / \ 27 10 O I I 26 13 MASTER z7 BEDROOM I LIVING O. S_ ROOM I\ M CLO --- --- MASTER 13 RO 22 23 BATH I � 15 M CLO O 25 % 29 30 O 2 BEDROOM 2 l\�\16/i��l 313z 27 II \ / 11 DINING to DEN -- -- it 17 ENTRY \ / 18 O r � 'I nl II ` 19 BATH 2 1 �-- -- 27 ❑I I� ^\ LJI II / --------- II LI 1 1 1 1 .fS 3 DEMO PLAN 4"=1' SCALE I l D PATIO REMOVALS O1 REMOVE EXISTING CLOSET O REMOVE EXISTING CLOSET REMOVE EXISTING WET BAR CAP EXISTING WATER -----`�--- SUPPLY LINES AND SANITARY LINES AS REQUIRED 14 \\ O4 REMOVE EXISTING NON SUPPORTING WALL O\\ OS REMOVE EXISTING ANGLED WALLS (SUPPORTING WALL TO \\ \ REMAIN) IA \ © REMOVE EXISTING ANGLED WALL 0M O7 REMOVE EXISTING KITCHEN APPLIANCES O8 REMOVE EXISTING KITCHEN COUNTERTOP O9 REMOVE KITCHEN CABINETS 27 10 REMOVE EXISTING POCKET DOOR IN KITCHEN 11 REMOVE EXISTING CORNICE ABOVE 12 REMOVE EXISTING POSTS 13 REMOVE EXISTING BOOKSHELVES 14 REMOVE EXISTING SLIDING GLASS DOORS AND HARDWARE �' 15 REMOVE EXISTING GYP BOARD FROM AROUND OPEN WALL SECTION PREPARE TO INFILL OPENING F-------- I 16 REMOVE EXISTING FRONT DOUBLE DOORS Ir 17 REMOVE EXISTING ARCHED TRANSOM WINDOW IlLi I KITCHEN I�• I 27 MOVE EXISTING FIXED ARCHED WINDOW 7 8 9 ILJ I I 19 REMOVE ALL BATHROOM FIXTURES ,VALVES 28 I AND ASSOCIATED HARDWARE IN BATH #2 — J I 20 REMOVE EXISTING SHOWER AND ASSOCIATED HARDWARE. CAP EXISTING WATER LINES AND REMOVE EXISTING SANITARY LINE AS NEEDED 24 Z1 REMOVE EXISTING SOAKING TUB 22 REMOVE EXISTING SINKS, VALVES AND ASSOCIATED HARDWARE 23 REMOVE EXISTING VANITY 24 REMOVE EXISTING ELECTRICAL PANEL 25 REMOVE EXISTING RECESSED CEILING LIGHTS IN FOYER AND DINING ROOM 26 REMOVE EXISTING EXTERIOR DOOR AT CABANA BATH 27 REMOVE ALL WINDOWS AS MARKED FOR REPLACEMENT IN GARAGE EXISTING OPENINGS 28 REMOVE EXISTING KITCHEN CEILING LIGHTING 29 REMOVE EXISTING RECESSED CAN LIGHTING IN ENTRY 30 REMOVE EXISTING ENTRY LIGHT SWITCHES 31 REMOVE EXISTING DINING ROOM RECESSED CAN LIGHTING 32 REMOVE EXISTING DINING ROOM LIGHT SWITCHES 33 REMOVE EXISTING VAPOR PROOF LIGHT IN MASTER BATHROOM WIRING AND SWITCH 34 REMOVE EXISTING VANITY LIGHTING IN MASTER BATHROOM 35 REMOVE EXISTING MASTER BATHROOM RECESSED CAN LIGHTING Scope of Work Single level CBS single family residence Interior Renovation Building Code 2017 Florida Building Code: Residential 2014 National Electric Code Design Loads Roof Live Load: 20.0 p.s.f. Roof Dead Load: 25.0 p.s.f. Floor Live Load: N.A. Wind Speed: 160 MPH (3 second gusts) Wind Importance Factor: 1.0 Building Category: II Wind Exposure: B Internal Pressure Coefficent: .18 • Structure Designed: Enclosed Soil bearing capacity: 2000 p.s.f. GENERAL NOTES: 1. ALL CONSTRUCTION AND MATERIALS SHALL CONFORM TO THE 2017 FLORIDA BUILDING CODE. 2. INSTALL ALL MATERIALS PER MANUFACTURER'S STANDARDS AND SPECIFICATIONS. 3. PATCH ALL SURROUNDING DAMAGED AREAS TO MATCH EXISTING FINISHES. 4. NONCOMBUSTIBLE MATERIALS SHALL CONFORM TO SECTIONS 703.4, 703.4.1, 703.4.2 OF THE FLORIDA BUILDING CODE. DEMO SCHEDULE — — — — — — EXISTING TO BE REMOVED EXISTING TO REMAIN AREA SCHEDULE LIVING AREA 2808 SQ. FT. GARAGE 554 SQ. FT. PATIO 239 SQ. FT. ENTRY 26 SQ. FT. TOTAL 3627 SQ. FT. SUMMIT DESIGN & FORENSICS, INC. 725 SE PORT SAINT LUCIE BLVD. SUITE 203 PORT SAINT LUCIE FL 34984 (772)285-0572 BRIAN J. MASKOL FL PE #66080 = * ; No. 0 �� �NAi z 0 a U U LU w 0 LU 0 z 0 w K Q z J J W = J IL wm zo Q�U Wm Z�Q CL 06 D J DATE DESIGNED GMW 03-27-20 DRAWN GMW 03-27-20 CHECKED RECEI7Permittinq JOB NO. MAY 2 0 2020-087 G�`"' > "� ST. Luce Count REVIEWED FOR CODE COMPLIANCE ST. LUCIE COUNTY ' BC)CC C"Op""T s(z[ A A-3 yvp 0 Q6 PATIO MASTER BEDROOM El LIVING ROOM O M CLO MEDIA LIGHT ROOM TUBE 13 Q@,I MASTER @20 BATH LIGHT FYITUBE M CLO © II O 8 t2 II (D I I (t6� ' REF BEDROOM 2 DiNINO © 0 DEN ❑W 1❑ 11 NEW i q� ® D o ENTRY 12 13 NEW 18 BATH 2 A-3 e OT s O 1t I O �o NEW WORK 17 NEW KITCHEN CABINETS UPPER AND LOWER FOLLOW KITCHEN DESIGNERS LAYOUT O1 NEW WALL SECTIONS AND 2668 DOOR 18 NEW REFRIGERATOR O REPAIR AND REFINISH AS NEW 19 NEW ELECTRIC STOVE INFILL WALL SECTION TO MATCH EXISTING 20 NEW DISHWASHER O4 INFILL WALL SECTION TO MATCH EXISTING 21 NEW MICROWAVE 22 NEW BEVERAGE COOLER O NEW GLASS PANELS RECESSED INTO BASE 23 NEW DOUBLE SINK, VALVES AND ASSOCIATED HARDWARE RECESSED INTO FLOOR U6 NEW OUT SWING FRENCH DOORS 8 NEW KITCHEN COUNTERTOP FOLLOW KITCHEN DESIGNERS LAYOUT 7O NEW "RECTANGULAR" TRANSOM WINDOW 25 NEW CENTER ISLAND FOLLOW KITCHEN DESIGNERS LAYOUT INFILL AS NEEDED (SEE DETAIL FOR INFILL) 26 NEW LIGHT TUBES IN KITCHEN, MEDIA ROOM AND MASTER n NEW "RECTANGULAR" TRANSOM WINDOW BATH. LIGHT TUBES MAY BE MOVED AT THE DISCRETION OF INFILL AS NEEDED (SEE DETAIL FOR INFILL) THE CONTRACTOR AND/OR OWNER KITCHEN BEV CLR 2 1 Q QI I DW I IL z Ir. LIGHT TUBE LLJ 19 21 GARAGE s -I I 5 I 4 I_ I 4 1 0 R `O.. A• 5 5. I >t A.4 I 14 Wind Zones - Walls WIND DESIGN PRESSURES END WIND TRIB. ZONES- PSF 17 2 3 4 5 ZONE SPEED AREA <10 S.F. -30.6 -53.8 -78.8 +33.5 +33.5 -36.3 -44.8 20 S.F. -29.8 -49.0 -73.6 +31.9 +31.9 4 FT. 160 -34.8 -41.8 50 S.F. -28.6 -43.3 -66.9 +29.9 -32 7 +29.9 -37.8 MPH 100 S.F. -27.7 -39A -61.8 1 +28.5 +28,5 -31 3 -34.8 500 S.F. +24.9 +24.9 -27.7 -27.7 ALLOWABLE PRESSURES ARE FOR WINDOWS AND DOORS, FRAMING, ROOFING AND OTHER BUILDING COMPONENTS AND CLADDING. ROOF ZONES: 1 THRU 3 WALL ZONES: 4 AND 5 PROPOSED INIEW FLOOR PLAN i"=1' gCALE O9 NEW TOILEf,:VALVE AND HARDWARE 27 INFILL EXISTING OPENING 28 REBUILT EXISTING WALL 10 NEW TUB AND HARDWARE. 11 NEW DOUBLE SINK, VANITY, COUNTER, VALVES AND ASSOCIATED HARDWARE WINDOW SCHEDULE 12 NEW TOILET, VALVE AND HARDWARE 13 NEW DOUBLE SINK, VANITY, COUNTER, VALVES AND ASSOCIATED HARDWARE 14 NEW SHOWER, SHOWER PAN, MIXING VALVE AND ASSOCIATED HARDWARE CONNECT SHOWER SANITARY TO EXISTING TUB LINE IN MINIMUM SIZE 2" TRENCH AS/IF REQUIRED iS NEW SLIDING GLASS DOOR IN MASTER BEDROOM 16 NEW 200A "SQUARE D" OR EQUAL POWER PANEL I� NOTE: FIELD VERIFY ALL MASONRY OPENINGS AND WINDOW/DOOR SIZES PRIOR TO ORDERING MATERIALS NOTE: PRECAST LINTELS SHALL CONFORM TO CAST CRETE RECCOMENDATIONS & SPECIFICATIONS MARK FRAME SIZE TYPE REMARKS 1 105"x 72" Fixed Impact Q2 36"x 71" Fixed Impact Q 106"x 28-1/4" Fixed Impact 4 36"x 28-1/4" Fixed Impact Q 36"x 63" Fixed Impact © 37 x 63" Singlehung Impact 7 47"x 56" Fixed Impact 8 73"x 61-1/2" Singlehung Impact Q9 46"x 24" Fixed Impact 10 74"x 63" Singlehung Impact 11 NEW 74"x 36" Fixed Impact 1 73"x 61-1/2" Singlehung Impact 13 NEW 74"x 36" Fixed Impact 14 37"x 63" Singlehung Impact 15 60"x 37" Rolle°ntal Impact 16 74"z 63" Fixed Impact 17 46"x 23-1/2" Fixed Impact ALL WINDOWS ARE REMOVE AND REPLACE IN EXISTING WINDOW OPENIN CLEAR GLASS, LOW E DOOR SCHEDULE Exterior Doors Size Type 72" X 80" 3 PANEL CLEAR GLASS AIRMASTER DOUBLE OUTSWING 2❑ 139-7/16" X 96" 3 PANEL CLEAR GLASS SLIDING GLASS DOOR POCKET 30"`X 80" AIRMASTER FULL GLASS 72" X 80" FIXED PANEL CLEAR GLASS SLIDING GLASS DOOR 48" X 80" FRENCH DOOR SOLID PANEL © 60" X 80" FRENCH DOOR SOLID PANEL n I I I � AREA OF NEW WORK I I \ VTR REMOVE AND CAP 3- 1-1/2 V EXISTING SINK I \ \ NEW I \ \.. UNNEISTARY AND VENT I I� II I \ \\ I I \ 2' EW SHWR REMOVE AND CAP I SANIIAARYRSAHND OWEVENr \ \ UNES I , �- II \ Ir< \ l --'--� EXISTING �\`\ PLUMBING RISER DIAGRAM \\\\ NOT TO SCALE \ ' \ � TO SANITARY * PLUMBER TO LOCATE SEWER \SYSTEM AND WATER CONNECTIONS Ja .ems DESIGN & FORENSICS, INC. 725 SE PORT SAINT LUCIE BLVD. SUITE 203 PORT SAINT LUCIE FL 34984 (772) 285-0572 BRIAN 1. MASKOL FL PE #66080 �� Q>,• 0o F'• * N 0 700, ATEjQ NA 11������\ z 0 u w 0 w Q z T- W .J W D u- :J ` LJJ O I- z�U Co N W p-1 J ^ L.V 06 Q y DATE DESIGNED GMW 03-27-20 DRAWN GMW 03-27-20 CHECKED JOB NO. 2020-087 PRODUCT APPROVAL Approval Product Model Number Manufacturer Glass Attachment Method Building Rated Product Rated Number Type Design Pressures Design Pressures NOA No. 19-0611.07 Aluminum Series 410 Win Door Inc. Impact 1/4" x 1''11/4" min embedment i Tdpcons See Plan +/- 60.7 Fixed Window at 16" o. max. NOA No. 18-0430.05 Aluminum Fixed Windo w PW7720A PGT Industries Inc Impact 1/4" x 111/4" min embedment See Plan +/- 80.0 Topcons at 2-1/2 / 12 o.c. max. Aluminum 1/4" x 1',1/4" min embedment Tapcons al 6"/ 12"o.c. NOA No. 18-0430.06 S.H. Windows SH7700A PGT Industries Inc Impact Max. See Plan +65/-80 NOA No. 18-0627.01 Aluminum Horizontal Roller HR7710A PGT Industries Inc Impact 1/4" x 1:1/4" min embedment Topcons a 22.5"o.c. See Plan +/— 65.0 Windows max. Aluminum 1/4" x 1'1/4" min embedment. NOA No. 19-1126.06 Horizontal Sliding SGD-770 PGT Industries Inc Impact Topcons 1"/ 4"o:c. See Plan +/— 60.0 Window at max. NOA No..18-0926.06 Aluminum Door Series 450 WinDoor Inc.Impact 1/4" x 1 1/4" min embedment Tapcons a1 19"0., c. max. See Plan +/-70.0 $" PLYWOOD FASTENED WITH 8d SPA. @ 6" O.C. NEW WINDOW 8"X8" POURED CONCRETE SILL W/ STUCCO FINISH TO (2)-#5. EPDXY REINFORCING 6" I G MATCH EXISTING MIN. INTO JAMBS. • 'JYF D T CTI Ill CD6 o . l QI- I. #4 DOWEL SPA. @ 4'-0" I O.C. MAX. EPDXY 6" INTO EX. FOOTER. I I I u III�IIIII I I-4I'i J— EX FOOTING SECTION A 1fj=1' SCALE (2) No. 12 X 3" � 2X6 P.T. r-Irinl SIMPSON HGAM10KTA 4X6 P.T. W/ (4)-41' X 2j" TITEN2 2X6 P.T. & (4)-Iq" X lg' SDS (TYP.) VIEW B 1"=1' SCALE NEW WINDOW OPENING J" X 3y TAPCON SPA. @ 8" O.C. STAGGERED (TYP.) --- EX. MASONRY WALL No. 12 X 3" WOOD SCREW SPA. @ 8" O.C. STAGGERED (TYP.) 9Olength - ,h oi4 tlSk 4 t ryp536 k .. fi,,, xw z "ax . Net , x . a il.�aY a (- c r r pro` Cures The Top Rtjbbao� to ;,.;.,= d arm ILING BASE AT LIVING RO M STEP NOT TO SCALE PRE -MANUFACTURED ROOF TRUSSES 2'-0" O.C. -R-30 MIN. DRYWALL CIELING F TOP PLATE DRYWALL BOTH SIDES 2x4 WOOD STUDS SPACED @ 24" O.C. BASEBOARD (TYP.) 2x4 WOOD P.T. BOTTOM PLATE CONCRETE FLOOR YP INTERIOR NON LOAD kB0EAR,JNG WALL SECTION NOT TO SCALE #5 DOWEL X V-0" LNG. SPA. @ V-4" O.C. EPDXIED 6" INTO NEW SLAB INFILL. CONCRETE SLAB (TYP.) MATCH EX. EXISTING THICKNESS. CONCRETE SLAB n n COMPACTED FILL SAWCUT EXI'l HOT & COLD WATER LINES' CONCRETE SLAB INSULATED FULL DEPTH NEW SANITARY SEWER PIPE TO MATCH ELEVATION & GRADE FOR TIE-IN TO EXISTING SEWER LINE ETAI L NOT TO SCALE .�� DESIGN & FORENSICS, INC. 725 SE PORT SAINT LUCIE BLVD. SUITE 203 PORT SAINT LUCIE FL34984 (772)285-0572 BRIAN J. MASKOL FL PE #66080 v�GE i s ty N 0 = S1OIN z 0 a U V Ln w a 0 z LU WZr rD iii co 5-1 • DATE DESIGNED GMW 03-27-20 DRAWN GMW 03-27-20 CHECKED JOB NO. 2020-087 II I I I ELECTRICAL LEGEND 5 5" RECESSED LED CAN LIGHT 40 v V G 5" RECESSED LED CAN LIGHT W/ADJUSTABLE \ GIMBAL FOR DIRECTIONAL LIGHTING QO° 4 RECESSED LED CAN LIGHT i 1 UNDER CABINET LED LIGHTING sG G sc $DUPLEX OUTLET - _- 220 V OUTLET LI\ FI G SWITCH ROUND FAULT F INTERRUPTER ` \I WALL LIVING G I \\ SCONCE I RO M - THREE WAY SWITCH MASTER NOTE. RECEPTACLES IN KITCHEN & BATH AREAS TO 6E 46" A.F.F. L")Cr'1n ll llAA I / All 12aV SINGI.F PHASE 15 At 20 AMP BRANCH CIRCUITS SUPPLYING MCLU I I I. YHAJt It, & LU AMY bKAN.GH UIKUV11S WALL I ) MEDIA SCONCE I I " -- I ROOM I LIGHT �� ��.,( / \ (3) #2j 0 (THW) cop er O G and (1).#4,ground (PTHW) copper in 2 gals. conduit FI MASTER I `\ �,``.,, wall BATH LIGHT RELOCATED KITCHEN TUBE LIGHTING SWITCH M CLO RELOCATED EX. RELOCATED HALL LIGHTING Panel: 200 A.M.C.B. 0 LIGHTING SWITCH 200 Al O ® � 1 �, 3W 40 Circuit Panel 120/240 Volt �I EX REMOVE LIGHT a.c --� BEV GFI disc - - CLR G � ' ' F.P.L. service ,- KIT. _ I _ dla. x 10 0 I I 5/8 Underground. long ground rod l �10 d GFI. ._-..DENLIGHT ❑. TUBE ! 3�4„ copper I water pipe BEDROOM 2 NEW 200A tie ground wire ---�s POWER PANEL to footing rebars Electrical Riser Diagram OVEN C00 KTOP & 18 BATH 2 MICROWAVE NOTE: ALL EXISTING LIGHTING IN' HOME TO REMAIN UNLESS NOTES AS REMOVE AND REPLACE OR Electrical Load Calculations RELOCATE 2808 Living S.F. at 3 VA 8424 VA Two 20 Amp Appliance Ckts. 3000 VA Laundry 1500 VA Dryer 5000 VA Dishwasher 1200 VA ELECTRICAL PLAN = Trash Compactor 1000 VA Range' 12000 VA 4"=1' SCALE GARAGE Ref. Circuit 1300 VA WaterHeater 5500" VA Garage Door Opener 900 VA Disposal 800 VA Pool Equipment 3000 VA Pool Equipment 3000 VA Golf Cart Charger 2200 VA Total 48,824 VA First 10 KVA at 100% 10,000 VA Remainder at _40% 15,530 VA Total 25,530 VA I'I AC Heat at 100% 20,500 VA Ili) Total 46,030 VA 46,030 VA / 240 V = 192 Amps 200 Amp New Service Smoke detectors wired to 120V Bathroom lights Non Switchable, Non GFI El ectrical Y equipment loads contractor to verify all. e ui meat Prior to start of construction . Electrical contractor to recalculate n electrical schedule if loads are to be modified N1;1" ..�° ,, I DESIGN & FORENSICS, INC. 725 SE PORT SAINT LUCIE BLVD. SUITE 203 PORT SAINT LUCIE FL 34984 (772)285-0572 BRIAN J. MASKOL FL PE #66080 J. �O: Naiiia�,,\\ r z O U w 0 w Q z O In W • .i r 9W DATE DESIGNED GMW 03-27-20 DRAWN GMW 03-27-20 CHECKED JOB NO. 2020-087 E-1