Loading...
HomeMy WebLinkAboutPeterson HVHZ Roof pROOF ASSEMBLIES AND ROOFTOP STRUCTURES SECTION 1526 HIGH -VELOCITY HURRICANE ZONES - UNIFORM PERMIT APPLICATION Florida Building Code 6th Edition (2017) High -Velocity Hurricane Zen, Uniform Permit Application Form. INSTRUCTION PAGE COMPLETE THE NECESSARY SECTIONS OF THE UNIFORM ROOFING PERMIT APPLICATION FORM AND ATTACH THE REQUIRED DOCUMENTS AS NOTED BELOW: Roof System f the RequjAppiletlIn Permorm Attachments Required Sea List BelowLow Slope Application 1,2,3,4,5,6,7Prescriptive BUR-RAS 160 4,5,6,7Asphaltic Shingles 1,2,4,5,6,7Concrete or Clay Tile 1,2,3,4,5,6,7Metal Roofs 1,2,3,4,5,8,7 Wood Shingles and Shakes A,B,D 1,2p,6,6,7 Other As Applicable 1,2,3,4,6,6,7 ATTACHMENTS REQUIRED: 1. Fire Directory Listing Page 2. From Product Approval: Front Page Specific System Description Specific System Limitations General Limitations Applicable Detail Drawings 3. I Dee ign Calculations per Chapter 16, or If Applicable, RAS 127 or RAS Other 5. Municipal Permit Applic 6. 1 Owners Notification for FLORIDA BUILDING CODE 6th Edition 12017)—BUILDING 5.31 ROOF ASSEM8 LIES AND ROOFTOP STRUCTURES Master Permit Contractor's t Job Address Florida Building Code 6th Edition (2017) High -Velocity Hurricane Zone Uniform Permit Appliwtlon Fonn. Section A (General InforinatioW Process ❑ Low Slope ❑ Mechanically Fastened Tile (Asphaltic Shingles ❑ Metal Panel/Shingles ❑ Prescriptive BUR-RAS 150 ROOF TYPE WNew Roof QRepair ❑ Maintenance ROOF SYSTEM INFORMATION Low Slope Roof Area (SF) Steep Sloped Roof Area (SF) ❑ Mortar/Adhesive Set Tile ❑ Wood Shingles/Shakes 13 Reroofing ❑ Recovering Total (SF) 0 Section B (Roof Plate Sketch Roof Plan: Illustrate all levels and sections, roof drains, scuppers, overflow scuppers and overflow drains. Include dimensions of sections and levels, clearly identify dimensions of elevated pressure zones and location of parapets. 15.32 FLORIDA BUILDING CODE ath Edition (2017) —BUILDING ROOF ASSEMBLIES AND ROOFTOP STRUCTURES Florida Building Code 6th Edition (2017) High -Velocity Hurricane ton® Uniform Permit Application Form. S C -O C L w SI a rC do Surfacing: Fill in specific roof assembl omponents and identify manufacturer (If a component is not used, I Fastener S acin for Anchor tify es "NA") P 9 se Sheet Attachment: System Manufacturer: Field._"ac@Lap. ows_@_"cc Product Approval No.: Perimeter._"o LaP,#Rows_@_==oe Comer:_ @Lap,#Rows_@_"oc Design Wind Pressures, From RAS 12 r Calculations: Prow: Pmax2: p G: Number o eateners Per Insulation Board: M D ' Field Perimeter ax. aslgn Pressure, from the specific Approval system: Deck: Anchor/Base Sheet & No. of Ply(s):_ Anchor/Base Sheet Fastener/Bonding Insulation Base Layer. Base Insulation Size and Thickness: Base Insulation Fastener/Bonding M rial: Top Insulation Layer Top Insulation Size and Thlckn s: Top Insulation Fastener/Bon g Material: Base Sheet(s) & No. of Ply Base Sheet Fastener/Bon g Material: PlySheet(s) & No. of Ply(: Ply Sheet Fastener/Bond g Material: Top Ply: Top Ply Fastener/Bonding Material: _ Corner_ ustrate Components Noted and Details as pplicable: oodblocking, Gutter, Edge Termination, Stripping, Flashing, Continuous Cleat, Cam Strip, Base Flashing, Counter - Flashing, Coping, Etc. Indicate: Mean Roof Height, Parapet Height, Height of Base Flashing, Component Material, Material Thickness, Fastener Type, Fastener Spacing or Submit Mean Roof Height FLORIDA BUILDING CODE 6th Edition (20171—BUILDING 16.33 ROOF ASSEMBLIES AND ROOFTOP STRUCTURES Florida Building Code Edition 6th Edition (2017) High -Velocity Hurricane Zone Uniform Permit Applimeon Fonn. Section D (Steep Sloped Roof System) Roof System Manufacturer: NI R Notice of Acceptance Number- f«o'7y� I e raJ Minimum Design Wind Pressures, If Applicable (From 127 or Calculations rom R �1: 33 P2: S'7 P3: a'L � Steep Sloped Roof System D s intion Deck Type: -7 rr cmh Type Underlayment: no Slope: S d 30h. 2 Insulation: jJ 5 he d. Fire Barrier: N FF Shed Ridge Ventlla'o ' Fastener Type & Spacing: J" cn F I Adhesive Type: I vo �rm�nt Mean Roof Height: 11 Type Cap Sheet: /J/ A S e Roof Covering: \ Type &Size Drip Bdge: aal Uani zed a"xa" J drip ed9� ts.0 FLORIDA BUILDING CODE 01h edition (2017) —BUILDING For Mo fi based file sysmlb.c W�1 b the irlr vabsai (Oe ¢ch V (P2: � xx m2:_xx Eryuised Momevr of Buiaboce (M/ Mean Roof 'Mu¢ be oed in boJunction with Ica each aura of the mof. den the We ROOF ASSEMBLIES AND ROOFTOP STRUCTURES Florida Building Code 6th Edition (2017) /elOC4 Hurricane Zone Uniform Permit Application Form. Section E (Tile Calculations) e eiderMtlhM I m 2. Compare tlee, un m MrwiW Ne values 5om A9(.I( rvuluasuegrcaW lhepar of dm't,, men de file ebobb—f memaJ n armpbhk. Metbad I`Momms Bw "I Celculaiuns Fer IW 12T' —)-M8.__�Mr, P. ppmval Mr_ =—)-ME:�=MR_ P nAPpmval Mr_ —_)-M6:—=Mt.1_ rotluo Approval Mr_ Me od2'S'Wlifmd IDe111W-bme Per Ie Below" Ram Tubl elow_ Prodoa AP M f� IM quired Moment lsmnce' 5' 20' 25' of 20' 40' eodoaed by Bu: anwod Couby Bo of Rules aotl Appeal tfie .for Fe IfNe F vl amg , bb are4utlm Ne RNuu, Pm RA$120' W: B _Frl_ PrWua APWnvilF_ W. B 'Fa_ P�Wua AppoylF_ P bctA Pgorsl F _ I B :Me M P�bSl.1 aF W Pmduty Apprvval L=1en8W w _.._ai Pmdua APPrvral FLORIDA BUILDING CODE 60h Edition (2017) — BUILDING 15.05 SECTION 1524 - HIGH VELOCITY HURRICANE ZONES REQUIRED OWNERS NOTIFICATION FOR ROOFING CONSIDERATIONS 1524.1 Scope. As it pertains to this section, it is the responsibility of the roofing contractor to provide the owner with the required roofing permit, and to explain to the owner the content of this section. The provisions of Chapter 15 of the Florida Building Cade, Building govern he minimum requirements and standards of the industry for roofing system installations. Additionally, the following items should be addressed as part of the agreement between the own the contractor. The owner's initial in the designated space indicates that the item has been explained. V. Aesthetics -Workmanship: The workmanship provisions of Chapter 15 (High Velocity Hurricane Zone) are a purpose of providing that the roofing system meets the wind resistance and water intrusion performance standards. Aesthetics (appearance) are not a conslderefion with respect to workmanship ic tacance ch as color or architectural appearance, that are not part of a zoning code, should be addrelssed as partofment between the owner and the contractor. ng hen replacing roofing, existing nwtih the current provisions of Chapter 1s (HightVelocity Hurticanefdeck may Zones) of heve to be ronailed Flodda Bu'Iding J(il,�nlfiouses, lding. (The roof deck is usually concealed prior to removing the existing roof system). Common Roofs: Common roofs are those which have no visible delineation between neighboring units condominiums, etc.). In buildings with common roofs, the roofing contractor and/or owner should occupants of adjacent units of roofing work to be performed. arn ein below. ceilings: The ownerpmay wishntotmaintain ceilingsare rarchitectural appearanceere the undemide of[ theeforehe roof �lroofing can nal pe trations of the underside of the decking may not be acceptable. The provides the option of maintaining this p rice. . Pending Water: The current roof system and/or deck of the building may not drain well an tl may cause wa pond (awumulata) in low-lying areas of the roof. Ponding can be an indication of structural distress and may require the review of a professional structural engineer. Pending may Shorten the ]its expectancy and irents ce of the new roofing system. Pending conditions may not be evident until the original roofing system is ending conditions should be corrected. Overflow Scuppers (wall outlets): It is required that rainwater flow off so that the roof is not Overloaded ildup of water. Perimeter/edge walls or other roof extensions may block this discharge if overflow wall outlets) are not provided' It may be necessary to install overflow scuppers in accordance with the of Chapter 15 and /6 herein and the Florida Building Code, Plumbing. Ventilation: Most roof structures should have some ability to vent natural airflow through the interior of al assembly (the building itself). The existing amount of attic ventilation shall not be reduced. Exception: Attic spaces, designed by a Florida licensed engineer or registered architect to eliminate the attic venting, venting shall not be required. COMMENTS: 44)&0 Contractor's Signature City of Plantation Rev. 03/15/12 UL Evaluation Report UL ER2453-02 Issued: April 5, 2017 Malt JU. OmLinp Certifica6ona Dl,ectory: bw,ul.comlerdi=ectoy for current etatua of Ropoet bm UL Category Cade: ULEZ CS] MasterFormaM 1 DIVISION: 07 00 00 —THERMAL AND MOISTURE PROTECTION Sub4evel 2: 07 30 00 — Steep Slope Roofing SUb4GVel 3: 07 3100 — Shingles and Shakes Sub-leval 4: 07 31 13 _ Asphalt Shingles COMPANY: OWENS CORNING ONE OWENS CORNING PKY TOLEDO, OH 43659 (419)248-7060 (,La:llwwvu owonscorntr<o.cnml I. SUBJECT: Asphalt Shingles CLASSIC®,SUPREME®, DURATION® PREMIUM, TRUDEFINITIONS DURATIONS, TRUDEFINITIONS DURATION® STORMTM, TRUDEFINITIONS DURATIONS MAX', TRUDEFINITIONS OAKRIDGES, OAKRIDGES, WOODCRESTS, WOODMOORS, TRUDEFINITIONS WEATHERGUARDS HP, BERKSHIRES, DEVONSHIRE-, WOODSTARTS STARTER SHINGLE, STARTER STRIP PLUS, STARTER STRIP SHINGLE, AND TRI BUILT STARTER STRIP BERKSHIRES HIP & RIDGE SHINGLES, HIGH RIDGE HIP & RIDGE SHINGLES WITH SEALANT, RIZERIDGES HIP & RIDGE SHINGLES WITH SEALANT, WEATHERGUARDS HP HIP & RIDGE SHINGLES, PROEDGES, DURARIDGE, HIP & RIDGE SHINGLES AND PROEDGES STORMS HIP & RIDGE SHINGLES 2. SCOPE OF EVALUATION ■2015, 2012, 2009, and 2006 lntemational Building Cade S (IBC) 02015, 2012, 2009, and 2006 international Residential Cade S (IRC) Y ICC ES Acceptance Criteria for Quality Documentation (ACI0), Dated December 2012 ® ICC ES Acceptance Criteria for Alternative Asphalt Roofing Shingles (AC438), Dated March 2012 The products were evaluated for the following properties ■External Fire Exposure (ANSIN1-790, ASTM E108) ■ Wind Resistance (ASTM 03161; ASTM D7158) ■ Physical Properties (CC-ESAC438) 3, REFERENCED DOCUMENTS ■ ANS VUL790 Eighth Edition, (ASTM E108), Standard Test Methods for Fire Tests of Roof Coverings ■ ASTM D3161-13, Standard Test Method for Wind -Resistance of Steep Slope Roofing Products (Fan -Induced Method) ■ ASTM D7158.11, Standard Test Method for Wind Resistance of Asphalt Shingles (Uplift ForceNpllft Resistance Method) ■ UL Subject 2375, Outline of Investigation for Hip and Ridge Shingles (UL Fire and Wind Tests) ■ ICGES Acceptance Criteria for Alternative Asphalt Roofing Shingles (AC438), Dated March 2012 4, USES OWENS CORNING asphalt shingles described in this report are alternatives to asphalt shingles complying with Section 1507.2.5 of the 2015, 2012, 2009 and 2006 IBC and Section R905.2.4 of the 2016, 2012, 2009, and 2006 IRC, and are Class A roof coverings for new and existing roofs. 5. PRODUCT DESCRIPTION OWENS CORNING asphalt shingles are roof covering materials complying with the following properties when installed as described in this report. The products are three -tab shingles, laminated shingles and hip & ridge shingles. The products are available In standard and metric sizes. Fire Classification: OWENS CORNING asphalt shingles covered under this Report have been tested for fire classification Class A In accordance with UL790 (ASTM El08). Shingles tested in accordance with UL790 (ASTM E108) qualify for use under Section 1505.1 of the 2015, 2012, 2009 and 20061BC and Section R902.1 of the 2015, 2012, 2009 and 2006 IRC. Wind Resistance: OWENS CORNING asphalt shingles covered under this Report have been tested for wind resistance In accordance with ASTM D3161 or ASTM D7158. Shingles tested in accordance with ASTM D3161 are classified as Class F or Class A and qualify for use under the exception to Section 1507.2.8.1 of the 2016 IBC, Section 1607.2.7.1 of the 2012, 2009 and 2006 IBC, or the exception to Section R905.2A.1 of the 2015, 2012, 2009 and 20061RC. Shingles tested in accordance with ASTM D7158 are classified as Class H and qualify for use in locations as shown in Table 1504.1.1 of the 2015 IBC, Table 1607.2.7.1 of the 2012 and 2009 IBC or Table R905.2.4.1 of the 2015, 2012 and 2009 IRC, where the maximum basic wind speed is 150 mph (67 m/s) or less with exposure category of S or C (ASCE 7) and a maximum building height of 60 feet (18.3 m). Installation must be in accordance with Section 1507.2.7 of the 2015, 2012, 2009 and 2006 IBC or Section R906.2.6 of the 2015. 2012, 2009 and 2006 IRC, as applicable. Physical Properties: OWENS CORNING asphalt shingles covered under this Report have been tested for physical properties in accordance with AC 438. Shingles tested In accordance with AC438 qualify as an altemative roof covering for use under Section 1507.2.5 of the 2015, 2012, 2009 and 2006 IBC or Section R905.2.4 of the 2015, 2012, 2009 and 2006 IRC. When Installed in new construction in accordance with this report and the OWENS CORNING Installation instructions, the shingles area Class A fire classification roof covering. When the shingles are installed over existing roof coverings, the fire classification Is maintained. Peas 2 of 3a MIJ6h11• MICONTRO SKCTPOY �fA�867A�A rR�RJ RE MINISTR TANDION ECONOMIC RESODRCES (REA) PRODUCT CONTROL SECTION UE ADMINISTRATION DIVISION I1805 Sw 26 atrcef, Room 208 beeau, Florida 33175 2474 T (786) 315 2590 F (786) 315-25W NOTICE OF ACCEPTANCE (NOA) ,.,. _...�.e..� � Owens Coming Roofing and Asphalt, LLC One Owens Coming Parkway Toledo, OH 43659 SCOPE: This NOA is being issued under the applicable riles and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami -Dade COunry RE -Product Control Section to be used in Miami -Dade County and other areas where allowed by the Authority Having Jurisdiction (AHD). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section (in Miami -Dade County) and/or the AHJ (in areas other than Miami -Dade County) reserve the right to have this Product Or material tested for quality assurance purposes. If this product or material fails to perform in the accepted iately revoke, manner, the manufacturer will incur the expense of such testing and the AHD may immedmodify , or suspend thee of such product or material within theirjmisi iction. RER reserves the right to revoke t if it is determined by Miami -Dade County Product Control Section that this product Or material fais acceptance, ils to his the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: Oakridge®, TruDefinition Oakridgeg, and TruDetlnition Oakridge® Artisan Colors Shingles LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at thejob site at the request of the Building Official. This NOA renews NOA No. 12-0430.01 and consists of pages I through 4. The submitted documentation was reviewed by Gaspar D Rodriguez. HIgH4napECOtlNTY (f NOA No.: 151102.03 Expiration Date: 02/03/21 Approval Date: 01/21/16 Page 1 of 4 ROOFING ASSEMBLY APPROVAL Category: Roofing Sub -Category: Asphalt Shingles Materials: Laminate Deck Type, Wood SCOPE This approves a roofing system using Onkridge®, TraDefrdtion Oakrldge®, and TruDefinition Oakrldge® Artisan Colors asphalt shingles manufactured by Owens Coming as described in Section 2 of his Notice of Acceptance. PRODUCT DESCRIPTION Product Oakridge®, TruDefinition Oakridge®, and TruDefinition Oakridge® Artisan Colors Manufacturing Locations #1, 2, 3, 4 Oakridge®, TruDefinition Oakridge®, and TruDefinition Oakridge® Artisan Colors Manufacturing Locatfon #1, 2, 3, 4, 5 Dimensions Test Specifications 13 'C' x 393/s" TAS 110 Product Description A heavy weight, fiberglass reinforced laminate asphalt shingle with continuous bead of sealant. 13 %4" x 39 s/s" TAS 110 A heavyweight, fiberglass reinforced laminate asphalt shingle with dashed bead of sealant. MANUFACTURING LOCATION 1. Memphis, TN 2. Irving, TX 3. Savannah, GA 4. Jacksonville, FL 5. Atlanta, GA EVIDENCE SUBMITTED Test Agency Test Identifier Test Name/Report Date PRI Construction OCF-153-02-01 TAS 100 Materials Technologies OCF-152-02-01 TAS 100 09/22/10 OCF-15-02-01 TAS 100 09/21/10 OCF-151-02-01 TAS 100 11/10/10 0-02-01 TAS 100 0927/10 GCF-1 CF-165-02-01 TAS 00 0921/10 OCF-170-02-01 TAS 1100 01/07/11 OCF-17-02-01 TAS 100 06/06/11 OCF-1787 -02-01 TAS 100 12/05/11 02/02/12 NOA No.: 15-1102.03 Expiration Date: 02/03/21 Approval Date: 01/21/16 Page 2 of 4 Underwriters 09NK14530 ASTMD 3462 Laboratories 12/31/09 R2453 ASTM D 3462 1//10 R2453 ASTMD 3462 11/0303/10 R2453 ASTM D 3462 10/11/10 R2453 ASTM D 3462 10/11/10 R2453 ASTME 108 01/13/11 R2453 ASTM E 108 10/11/10 R2453 ASTM E 108 11/03/10 R2453 ASTME 108 10/11/10 R2453 ASTM E 108 09NK14530 TAS 107 (ASTM D 3161) 10/11/10 12/31/09 R2453 TAS 107 (ASTM D 3161) 10/27/15 1ONK13947 TAS 107 (ASTM D 3161) 11/12/10 R2453 TAS 107 (ASTMD 3161) 10/11/10 R2453 TAS 107 (ASTM D 3161) 10/27/15 IONK13947 TAS 107 (ASTM D 3161) 0129/11 IICA15662 TAS 107 (ASTM D 3161) 0527/11 1ICA65092 ASTM D 3462 / TAS 107 (ASTM D 3161) / ASTM E 108 02/14/12 11CA40912 ASTMD 3462/ TAS 107 (ASTM D 3161)/ASTM 15log 11/30/11 LIMITATIONS 1. Fire classification is not part of this acceptance; refer to a current Approved Roofing Materials Directory for fire ratings of this product. 2. Shall not be installed on roof mean heights in excess of 33 R. 3. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and Rule 61G20-3 of the Florida Administrative Code. INSTALLATION 1. Shingles shall be installed in compliance with Roofing Application Standard RAS 115. 2. Flashing shall be in accordance with Roofing Application Standard RAS 115 3. The manufacturer shall provide clearly written application instructions. 4. Exposure and course layout shall be in compliance with Detail'A', attached. 5. Nailing shall be in compliance with Demil'B', attached. LABELING 1. Shingles shall be labeled with the Miami -Dade Seal as seen below, or the wording "Miami -Dade County Product Control Approved". MIAMI-DADECOUMry �111,1011411� BUILDING PERMIT REQUIREMENTS I. Application for building permit shall be accompanied by copies of the following: 1.1 This Notice of Acceptance. 12 Any other documents required by the Building Official or the applicable code in order to properly evaluate the installation this of system. MIgn1DM^" NOA No.: 15-1102.03 �u..... Expiration Date: 02/03/21 Approval Date: 01/21/16 Page 3 of 4 DETAIL A DETAIL B END OF THIS ACCEPTANCE MIAM1 RLINTY EXPOSURE NOA No.: 15-1102.03 Expiration Date: 02/03/21 Approval Date: 01/21/16 Page 4 of 4