HomeMy WebLinkAboutAuger Anchor DetailsEACH 2'-0" BLOCK MUST BE INSTALLED WITH (2) ROWS y OF 10d NAILS @ 3" O.C. ° J 0 ATTACH BRACKET TO J STUD STUD THRU HOLE IN ANCHOR PLATE WITH o ° 3/8"0 x 6" CARRIAGE in lV BOLT AND LOCKNUT CORNER STUD STUD SIDING END WALL TRIM LANCHOR BRACKET TO BE FLUSH WITH EDGE OF TRIM 0 n ANCHORS INSTALLED AT EACH CORNER OF THE BUILDING AUGER ANCHO Y OLIVER TECHNOLOGIES • PART NUMBERS: OT3644GPMP- 5/8" X 36" (36" IMBED) GALVANIZED AUGER OT17SWB - SIDEWALL BRACKET FOR USE WITH THRU BOLTS REPORT NO. LO-FJ90129-A -OR- OT24SWBSIDEWALL BRACKET FOR USE WITH THRU BOLTS REPORT NO. LO-FJ90129-B • WORKING LOAD FOR ANCHOR SYSTEM IS 3,150 LBS WITH THE MAXIMUM LOAD OF 5,080 LBS • THE ANCHORS MUST BE INSTALLED AND TESTED IN ACCORDANCE TO THE MANUFACTURER'S SPECIFICATIONS. \ \ 1 IINIV/ � i No 35 2017 FLORIDA BUILDING CODE, 6TH EDITION, HVHZ - P OF � `r /p •� E Scale: NTS CUSTOMERS NAME: Tuff Shed P.O .# �///llllllllllll�� QTUFFSHED' TitIe:AUGERANCHOR DETAIL Drawn By:PK abm,Foum%' &e•" Date Drawn: 3/13119 FOR WIND SPEEDS Checked By: UP TO 175 MPH Date Revised: BUILD SIZE OTY OF ANCHORS UP TOING 8X12 4 UP TO 10X15 4