HomeMy WebLinkAbout7. Farrell Storage 605 Kitterman Rd. Signed and Sealed Drawings.This Design, in whole or in part, is the property of Art-Kraft Sign Company and may not be used without the expressed written permission of Art-Kraft Sign Company, Inc.2675 Kirby Circle N.E. Palm Bay Fl., 32905 (321) 727-7324 FAX (321) 951-2466
ART-KRAFT SIGN COMPANY, INC.
CUSTOMER APPROVAL DATE
ART-KRAFT SIGN COMPANY IS NOT RESPONSIBLE
FOR PRIMARY ELECTRICAL HOOK-UP OF SIGN
DESIGN NO.
SCALE
REVISION
DATESALES REP.
www.Art-Kraft.com
ArtKraftSigns
COLOR SCHEDULE:
WALL SIGN FACE DECORATION
Celebrating 52 years of Quality
Manufacturing and Service
SIGN CUTAWAY SECTION
SCALE: NOT TO SCALE
PART DESCRIPTION
DESIGNER. AMANDA
CUSTOMER FARRELL STORAGE 39331
ROBERT AS SHOWN 6 - 11 - 20
ORIGINAL DESIGN NO. 00000
FACE DECORATION
CABINET
CABINET PANTONE 295
FACE PANTONE 295
EXTRUDED ALUMINUM SIGN CABINET
1-1/2” ALUMINUM ANGLE RETAINER SYSTEM
3/16” THICK ACRYLIC FACE ( PANNED OR FLAT )
( VINYL DECORATION WHERE APPLICABLE )
WHITE L.E.D. STRIPS MOUNTED INSIDE LETTERS
( MIN. 2 ) WEEP HOLES AS REQUIRED.
“WALL BUSTER” WALL PENETRATION SLEEVE KIT
CARLING 20 AMP. 120 - 277 VAC DISCONNECT SWITCH
CONDUIT TO PRIMARY POWER. POWER TO SIGN BY OTHERS
CABINET MECHANICALLY MOUNTED TO WALL
FASTENER TYPE DETERMINED BY WALL CONSTRUCTION
( MIN 4 FASTENERS PER CABINET )
2”x 2” x 1/8” ALUMINUM ANGLE MOUNTING BRACKETS
WELDED TO BACK OF CABINET INTERIOR
M1
M2
M3
M4
M7
M8
( 120 VOLT ) L.E.D. POWER SUPPLIES MOUNTED INSIDE OF
CABINET
M10
M9
M11
M5
M6
U in 110-277V ACI in 2.2-0.90AP in 140.0W
DC OUTPUT x 2
INPUT
U out DC 12VI out 0.10.0A(DUAL 5A)P out Each 60W MAXTOTAL 120W MAX
M1
M2
M7
M6
M10
M9
M11
M8M4
M3
UnderwritersLaboratories, Inc.
E147646 ( R )
ANCHOR SCHEDULE
WALL MATERIAL ANCHOR TYPE QTY OR SPACING
CONCRETE (3ksi)
or HOLLOW MANSONARY
1/2” PLYWOOD
(NO ACCESS BEHIND)
METAL
STUDS OR PANELS
HOLLOW WALL
+ BLOCKING
MIN. 4 PER 8 SQ. FT.
OF SIGNAGE
TOTAL 12 FASTENERS
MIN. 4 PER 8 SQ. FT.
OF SIGNAGE
TOTAL 12 FASTENERS
MIN. 4 PER 8 SQ. FT.
OF SIGNAGE
TOTAL 12 FASTENERS
MIN. 4 PER 8 SQ. FT.
OF SIGNAGE
TOTAL 12 FASTENERS
3/8” LAG BOLTS
#14 METAL SCREWS
TO MIN. 18GA STL OR .090 ALUMINUM
3/8” THRU BOLTS OR LAGS
TO SOLID BLOCKING BEHIND
3/8” EXPANSION ACHORS MIN. 3-1/2” EMBED
FULL EMBED
Engineer Notes:
1.Contractor to verify actual field conditions and
notify Engineer if conditions vary and require
different fasteners.
2. Seal all wall penetrations to prevent water
intrusion into building.
3.Anchors to be uniformly spaced.
This structure has been designed in accordance
with the requirements of Chapter 16, Structural
Design, of the 6th Edition (2017) Florida Building
Code. The following wind load requirements, in
accordance with Section 1609, were employed in
the design of the structure:
Ultimate Design Wind Speed: 160 MPH (3-Second
Gust Wind Speed) -Port St. Lucie, FL Nominal
Design Wind Speed: 124 MPH (3-Second Gust
Wind Speed); Building Risk Category: II;
Wind Exposure: B; External Pressure Coefficient,
GCp = -1.4 / +1.0; Design Pressure: -32.8 PSF /
+23.4 PSF
Wall Connection Engineer of
Record: James D. Wells, Jr., P.E.
Professional Engineer No. 53616
J & L Wells Consulting LLC
1453 Arbitus Circle
Oviedo, FL 32765
(407)496-5489
Certificate of Authorization No.
27162
SCALE 1/2” = 1’-0” (QTY. 3 ) LED ILLUMINATED SINGLE SIDED WALL SIGNS
FARRELL STORAGE
605 KITTERMAN ROAD
PORT ST. LUCIE, FL
7/8” SECONDARY POWER HOLE
DISCONNECT TOGGLE SWITCH
ON SIDE OF CABINET
(12) 3/8” WALL FASTENERS
( TYPE DETERMINED BY WALL CONSTRUCTION )
14'-0"
4'-6"
3'-8"
2'-0"
2'-0"
7"
Note: Pre-Engineered Wall Sign - Designed by Others
(12)3/8” WALL FASTENERS ( TYPE DETERMINED BY WALL CONSTRUCTION )
This item has been electronically signed and sealed by
James D. Wells, Jr., P.E. on 6/22/2020 using a Digital
Signature. Printed copies of this document are not
considered signed and sealed and the signature must be
verified on any electronic copies.