Loading...
HomeMy WebLinkAbout7. Farrell Storage 605 Kitterman Rd. Signed and Sealed Drawings.This Design, in whole or in part, is the property of Art-Kraft Sign Company and may not be used without the expressed written permission of Art-Kraft Sign Company, Inc.2675 Kirby Circle N.E. Palm Bay Fl., 32905 (321) 727-7324 FAX (321) 951-2466 ART-KRAFT SIGN COMPANY, INC. CUSTOMER APPROVAL DATE ART-KRAFT SIGN COMPANY IS NOT RESPONSIBLE FOR PRIMARY ELECTRICAL HOOK-UP OF SIGN DESIGN NO. SCALE REVISION DATESALES REP. www.Art-Kraft.com ArtKraftSigns COLOR SCHEDULE: WALL SIGN FACE DECORATION Celebrating 52 years of Quality Manufacturing and Service SIGN CUTAWAY SECTION SCALE: NOT TO SCALE PART DESCRIPTION DESIGNER. AMANDA CUSTOMER FARRELL STORAGE 39331 ROBERT AS SHOWN 6 - 11 - 20 ORIGINAL DESIGN NO. 00000 FACE DECORATION CABINET CABINET PANTONE 295 FACE PANTONE 295 EXTRUDED ALUMINUM SIGN CABINET 1-1/2” ALUMINUM ANGLE RETAINER SYSTEM 3/16” THICK ACRYLIC FACE ( PANNED OR FLAT ) ( VINYL DECORATION WHERE APPLICABLE ) WHITE L.E.D. STRIPS MOUNTED INSIDE LETTERS ( MIN. 2 ) WEEP HOLES AS REQUIRED. “WALL BUSTER” WALL PENETRATION SLEEVE KIT CARLING 20 AMP. 120 - 277 VAC DISCONNECT SWITCH CONDUIT TO PRIMARY POWER. POWER TO SIGN BY OTHERS CABINET MECHANICALLY MOUNTED TO WALL FASTENER TYPE DETERMINED BY WALL CONSTRUCTION ( MIN 4 FASTENERS PER CABINET ) 2”x 2” x 1/8” ALUMINUM ANGLE MOUNTING BRACKETS WELDED TO BACK OF CABINET INTERIOR M1 M2 M3 M4 M7 M8 ( 120 VOLT ) L.E.D. POWER SUPPLIES MOUNTED INSIDE OF CABINET M10 M9 M11 M5 M6 U in 110-277V ACI in 2.2-0.90AP in 140.0W DC OUTPUT x 2 INPUT U out DC 12VI out 0.10.0A(DUAL 5A)P out Each 60W MAXTOTAL 120W MAX M1 M2 M7 M6 M10 M9 M11 M8M4 M3 UnderwritersLaboratories, Inc. E147646 ( R ) ANCHOR SCHEDULE WALL MATERIAL ANCHOR TYPE QTY OR SPACING CONCRETE (3ksi) or HOLLOW MANSONARY 1/2” PLYWOOD (NO ACCESS BEHIND) METAL STUDS OR PANELS HOLLOW WALL + BLOCKING MIN. 4 PER 8 SQ. FT. OF SIGNAGE TOTAL 12 FASTENERS MIN. 4 PER 8 SQ. FT. OF SIGNAGE TOTAL 12 FASTENERS MIN. 4 PER 8 SQ. FT. OF SIGNAGE TOTAL 12 FASTENERS MIN. 4 PER 8 SQ. FT. OF SIGNAGE TOTAL 12 FASTENERS 3/8” LAG BOLTS #14 METAL SCREWS TO MIN. 18GA STL OR .090 ALUMINUM 3/8” THRU BOLTS OR LAGS TO SOLID BLOCKING BEHIND 3/8” EXPANSION ACHORS MIN. 3-1/2” EMBED FULL EMBED Engineer Notes: 1.Contractor to verify actual field conditions and notify Engineer if conditions vary and require different fasteners. 2. Seal all wall penetrations to prevent water intrusion into building. 3.Anchors to be uniformly spaced. This structure has been designed in accordance with the requirements of Chapter 16, Structural Design, of the 6th Edition (2017) Florida Building Code. The following wind load requirements, in accordance with Section 1609, were employed in the design of the structure: Ultimate Design Wind Speed: 160 MPH (3-Second Gust Wind Speed) -Port St. Lucie, FL Nominal Design Wind Speed: 124 MPH (3-Second Gust Wind Speed); Building Risk Category: II; Wind Exposure: B; External Pressure Coefficient, GCp = -1.4 / +1.0; Design Pressure: -32.8 PSF / +23.4 PSF Wall Connection Engineer of Record: James D. Wells, Jr., P.E. Professional Engineer No. 53616 J & L Wells Consulting LLC 1453 Arbitus Circle Oviedo, FL 32765 (407)496-5489 Certificate of Authorization No. 27162 SCALE 1/2” = 1’-0” (QTY. 3 ) LED ILLUMINATED SINGLE SIDED WALL SIGNS FARRELL STORAGE 605 KITTERMAN ROAD PORT ST. LUCIE, FL 7/8” SECONDARY POWER HOLE DISCONNECT TOGGLE SWITCH ON SIDE OF CABINET (12) 3/8” WALL FASTENERS ( TYPE DETERMINED BY WALL CONSTRUCTION ) 14'-0" 4'-6" 3'-8" 2'-0" 2'-0" 7" Note: Pre-Engineered Wall Sign - Designed by Others (12)3/8” WALL FASTENERS ( TYPE DETERMINED BY WALL CONSTRUCTION ) This item has been electronically signed and sealed by James D. Wells, Jr., P.E. on 6/22/2020 using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies.