HomeMy WebLinkAboutEnergy CodeFORM R405-2017
FLORIDA ENERGYEFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
_ Project Name: WYNULTHE GRAND CAR
Builder Name: WYNNE BUILDING CORR.
� Street: \r \�, ��e\�A_Q G
PermitOffice: ST. LUCIE COUNTY
City, State, Zip: FT. PIERCE, FL, ..J
Permit Number:
Owner. WYNNE BUILDING CROP
Judsdiction: ST. LUCIE COUNTY
Design Location: FL, Fort Pierce
County: St. Lucie (Florida Climate Zone 2 )
1. New construction or existing New (From Plans)
9. Wall Types (1442.0 sqft.)
Insulation Area
2. Single family or multiple family Single-family
a. Concrete Block - Int Insul, Exterior
R=4.1' 1250.00 ft-
3. Number of units, if multiple family 1
b. Frame - Wood, Adjacent
c N/A
R=11.0 192.00 ft=
R= ft=
4. Number of Bedrooms 2
d. N/A
R= ft=
5. Is this a worst case? YB5
10. Ceiling Types (1476.0 sqft.)
Insulation Area
a. Under Attic (Vented)
R=30.0' 1446.00 ft=
6. Conditioned floor area above grade (W) 1446
b. Knee Wall (Vented)
R=19.Q 30.00 ft=
Conditioned floor area below grade (ft=) 0
0• WA
R= ft
7. Windows(141.3 sqft.) Description Area
11. Ducts
a. Sup: Attic, Ret: Attic, AH: Attic
R ft=
6 250
a. U-Factor: Sgl, U=0.54 101.25 ft=
SHGC: SHGC=0.25
b. U-Factor: Sgl, U=0.55 40.00 ft=
12. Cooling systems
kBtu/hr Efficiency
SHGC: SHGC=0.25
a. Central Unit
34.8 SEER:15.00
c. U-Factor. N/A ft=
SHGC:
d. U-Factor. N/A
13. Heating systems
kBtulhr Efficiency
ft2
a. Electric Heat Pump
34.8 HSPF:8.50
SHGC:
Area Weighted Average Overhang Depth: 3.832 ft.
Area Weighted Average SHGC: 0.250
14. Hot water systems
8. Floor Types (1445.5 sqft.) Insulation Area
a. Electric
Cap:.50 gallons
a. Slab -On -Grade Edge Insulation R=0.0 1445.50 ft'
b. Conservation features
EF: 0.970-
b. N/A R= ft=
None
d. N/A R= ft.
15. Credits
Patel
Glass/Floor Area: 0.098 Total Proposed Modified Loads: 46.69
PASS
Total Baseline Loads: 48.09
I hereby certify that the plans and specifications covered by
Review of.the plans and
FOESTa
this calculation are in compliance with the Florida Energy
Code.
specifications covered by this
indicates
0
9,n
calculation compliance<_
with the Florida Energy Code.
1. ;ur,,.. !@ �O
PREPARED BY.,
Before construction is completed
c+
DATE: - 4-21-20
this building will be inspectedfor
compliance with Section 553.908
♦ o
I hereby certify that this building, as designed, is in compliance
Florida Statutes.
'
with the Florida Energy Code.
y'Opyy
OWNER/ N^ - '
BUILDING OFFICIAL:
DATE:
DATE:
Compliance requires certification by th an lamznit+�yftupsttiynccordance
a air handler enclosure qualifies as
certified cereqctorysealeicesa A accorBar den i1. 401.
Compliance requires an Air Barrier d In, u pe t o he with R402.4.1.1 and this project requires an
envelope leakage test report with envelope leakage no greater than 7.00 CHH50, f(�QQ2,4,1 21 FOR
ED
CODE COMPLIANCE
FT. LUCIE COUNTY
4/21/2020 10:24 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (20 ;)) m plant Software Page 1 of 5
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
PROJECT
.Title: WYNNE THE GRAND CARL .Bedrooms: 2
Address Type:
Street Address
Building Type: User Conditioned Area: 1446
Lot #
Owner Name: WYNNE BUILDING CROP Total Stories: 1
Block/Subdivision:
# of Units: 1 Worst Case: Yes
PlatBook:
Builder Name: WYNNE BUILDING COPR. Rotate Angle: 180
Street:,
Permit Office: ST. LUCIE COUNTY Cross Ventilation: No
County:
St. Lucie
Jurisdiction: ST. LUCIE COUNTY Whole House Fan: No
City, State; Zip: 'FT.PIERCE,
Family Type: Single-family,
FL,
New/Existing: New (From Plans)
Comment:
CLIMATE
Design Temp
Int Design Temp Heating
Design Daily Temp
V Design Location TMY Site 97.5�% 2.5 %
Winter
Summer Degree. Days Moisture
Range
FL, Fort Pierce FL VERO_BEACH_MUNI 39 90
70
75 299
62
Low
BLOCKS
Number Name Area Volume
1 Entire House 1446 11568
SPACES
Number Name Area Volume Kitchen Occupants
Bedrooms
Infil ID Finished Cooled.
Heated
1 BEDROOM 301 2408 No 0
1
1 Yes
Yes
Yes
2 WIC 63 504 No 0
1 No
Yes
Yes
3. M.BATH 56 448 No 0
1 Yes
Yes
Yes
4 KITCHEN 192 1536 Yes 0
1 No
Yes
Yes
5 BATH 45 360 No 0
1 Yes
Yes
Yes
6 BEDROOM 2 204 1632 No 0
1
1 Yes
Yes
Yes
7 ENTRY 55 440 No 0
1 Yes
Yes
Yes
8 LAUNDRY 42 336 , No 0
1 Yes
Yes
Yes
9 GREAT/DINING. 488 3904 No 0
1 Yes
Yes
Yes
FLOORS
# Floor Type Space Perimeter Perimeter R-Value
Area
Joist R-Value
Tile . Wood
Carpet
1 Slab -On -Grade Edge Insulatio BEDROOM 52 ft 0
301 ft'
____
0 1
0
2 Slab -On -Grade Edge Insulatio WIC 1 ft 0
63 ft'
____
0 1
0
3 Slab -On -Grade Edge Insulatio M. BATH 811 0
56 ft-
—_
0 1
0
4 Slab -On -Grade Edge Insulatio KITCHEN 1 ft 0
192 ft'
____
0 1
0
5 Slab -On -Grade Edge Insulatio BATH 5 ft 0
45 ft'
__
0 1
0
6 Slab -On -Grade Edge Insulatio BEDROOM 2 32.2 ft 0
203.5 IF
___
0 1
0
7Slab-On-Grade Edge Insulatio ENTRY 7 ft 0
55 ft'
___
0 1
0
4/21/2020 10:24 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6lh Edition (2017) Compliant Software Page 2 of 5
FORM R405-2017 INPUT SUMMARY. CHECKLIST REPORT
FLOORS
# Floor Type Space Perimeter Perimeter R-Value
Area
Joist R-Value
Tile
Wood Carpet
8 Slab -On -Grade Edge Insulatio LAUNDRY Eft 0
42 ft2
0
1
0
9 Slab -On -Grade Edge Insulatio GREAT/DINING 46 tt 0
488 ft2
___
0
1
0
ROOF
/ - Roof
Gable
Roof
Red
Solar
SA Emitt
Emitt Deck
Pitch
V # Type Materials Area
Area
Color
Barr
Absor.
Tested
Tested Insul.
(deg)
1 Gable or Shed Metal. 1524 ft2
240 ft2
Light
N
0.6
No 0.9
No 0
18.4
ATTIC
/
V # Type Ventilation
Vent Ratio (1 in)
Area
RBS
IRCC
1 Full attic Vented
150
1446 fP
N
N
CEILING.
# Ceiling Type Space -
R-Value
Ins Type
Area
Framing Frac Truss Type
1 Under Attic (Vented) BEDROOM.
30
Blown
301 ft2
0.1
Wood
2 Under Attic (Vented) WIC
30-
Blown
63ft2
0.1
Wood
3 Under Attic (Vented) M.BATH.
30
Blown
56ft2
0.1
Wood
4 Under Attic (Vented) KITCHEN
30
Blown
192 ft2
0.1
Wood
5 Under Attic (Vented) BATH
30
Blown
45 ft2
0.1
Wood
6 Under Attic (Vented) BEDROOM
30
Blown
204 ft2
0.1
Wood
7 Under Attic (Vented) ENTRY
30
Blown
55 ft2
0.1
Wood
8 Under Attic (Vented) LAUNDRY
30
Blown
42 ft2
0.1
Wood
_ 9 Under Attic (Vented) GREAT/DINING
30
Blown
486 ft2
0.1
Wood
10 Knee Wall (Vented) GREAT/DINING
19
Blown
30 ft2
0.11
Wood
WALLS
Adjacent Space Cavity Width,.
Height
Sheathing Framing
Solar Below
a
_ 1 NE=>SW Exterior Concrete Block - Int InsuBEDRO0M
4.1 10
0 8
0
80.0 ft2
0
0
0.4
0
2 SW=>NE Exterior Concrete Block - Int InsLBEDR00M
4.1 28
0 8
0
224.0 ft2
0
0
0.4
0
_ 3 _NW=>SE Exterior Concrete Block- Int InsdBEDR00M
4.1 14
0 8
0
112.0 ft2
0
0
0.4
0
_ 4 SW=>NE Exterior Concrete Block - Int Insul M. BATH
4.1 8
0 8
0
64.0 ft2
0
0
0.4
0
5. NE=>SW Exterior Concrete Block - Int Insul BATH
4.1 5
0 8
0
40.0 ft2
0
0
0.4
0
_ 6 NE=>SW Exterior Concrete Block - Int InsBIEOROOM2
4.1 16
0 8
0'
128.0 ft2
0
0
0.4•
0
_ 7 SE=>NW Exterior Concrete Block - Int InsEEDROOM 2
4.1 10.
0 8
0
80.0 ft2
0
0
0.4
0
_ 8 S=>N Exterior Concrete Block - Int InsBEDROOM 2
4.1 4
9 8
0
34.0 ft2
0
0
0.4
0
9 SW=>NE Exterior Concrete Block- Int InsElEDROOM 2
4.1 2
0 8
0
16:0 ft2
0
0
0.4
0
_
10 SE=>NW Exterior Concrete Block - Int Insul ENTRY
4.1 6
10 8
0
48.0 ft2
0
0
0.4
0
_ 11 SW=>NE Exterior Concrete Block - Int Insul ENTRY
4.1 1
0 8
0
8.0 ft2
0
0
0.4
0
12 SW=>NE Exterior Concrete Block - Int InsuLAUNDRY
4.1 6
0 8
0
48.0 ft2
0
0
0.4
0
_ 13 NE=>SW Exterior Concrete Block -'Int Inst3REAT/DINI
4.1 26
0 8
0
208.0 ft2
0
0
0.4
0
14 NW=>SE Exterior Concrete Block - Int InstOREAT/DINI
4.1 20
0 8
0
160.0 ft2
0
0
0.4
0
4/21/2020 1024 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 3 of 5
FORM R405-2017 IAIPIIT SI IMMAPV r_u=rtrn reT oconor
WALLS
Adjacent
space Cavity Width Height
.Sheathing Framing Solar Below
0
15 N=>S Garage Frame- Wood KITCHEN 11 24 8 192.0 ft-
- 0.23 0.4
0
DOORS
# Omt
Door Type Space Storms U-Value
Ft
Width Height
In Ft In
Area
1 SE=>NW
Insulated ENTRY None .39 3
1 6 8
20.6ft-
-WINDOWS
Orientation shown is the entered orientation. => changed to Worst Case.
Wall
V # Ornt ID Frame
1 NW=>SE 3 Metal
2 SW=>NE 4 Metal
3 SE=>NW 7 Metal
4 NE=>SW 13 Metal
5 NW=>SE14 Metal
Overhang
Panes -NFRC U-Factor SHGC Imp Area Depth Separation Int Shade.
Low-E Single Yes 0.54 0.25 N 32.9 ft' 1 ft 0 in 1 ft 5 in Drapes/blinds
Low-E Single Yes 0.54 0.25 N 6.9 ' 1 ft 0 in 1 ft 51n None
ft
Low-E Single Yes 0.54 0.25 N 24.0 ft' 6 ft 0 in 1 8 5 in None.
Low-E Single Yes 0.54 0.25 N 37:5 ft' 1 ft 0 in 1 ft 5 in None
Low-E Single Yes 0.55 0.25 N 40.0 ft' 8 ft 0 In 1 ft 5 in Drapes/blinds
Screening
Exterior 5
None
None
None
Exterior 5
GARAGE
# Floor Area
Ceiling Area Exposed Wall Perimeter Avg. Wall Height
Exposed Wall Insulation
1 315 ft2
315 ft- 24ft 8ft
11
INFILTRATION
# Scope Method
SLA ,CFM 50 ELA EgLA ACH
ACH 50
1 Wholehouse Proposed ACH(50) .000356 1349.6 74.09 139.34 .1233
7
HEATING SYSTEM
# System Type
Subtype Speed Efficiency Capacity
Block
Ducts
1 Electric Heat Pump/ Split Singl HSPF:8.5 34.8 kBtu/hr
1
sys#1
COOLING SYSTEM.
# System Type
Subtype Subtype Efficiency Capacity Air Flow SHR Block
Ducts
1 Central Unitl
Split Singi SEER:15 34.8 kBtu/hr cfm 0.8 1
sys#1
HOT WATER SYSTEM
# System Type
Subtype Location EF Cap Use SetPnt
Conservation
1 Electric
None Garage , 0.97 50 gal 60.9 gal 120 deg
None
4121/2020 10:24 AM £nergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 4 of 5
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
SOLAR HOT WATER SYSTEM
FSEC
Collector Storage
Cart # Company Name
System
Model #
Collector Model
# Area Volume
FEF
None None
ft2
DUCTS
/ — Supply--
—
Return --
Air
CFM 25
CFM25
HVAC #
V # Location R-Value Area
Location
Area
Leakage Type
Handler
TOT
OUT ON
RLF
Heat Cool
1 Attic
6 250ft2.
Attic
65 ft2
Default Leakage
Attic
(Default)
(Default)
1 1
`TEMPERATURES
Programable Thermostat: Y
Ceiling Fans:
Cooling Jan Feb
Venting Jan Feb
Mar
Mar
Apr
May
Jun
(X�
[ ] Jul
[X�
[ ] Aug
Sep
fr)(')
Dec
' l l
lxl
ANov
pr
May
Jun
[) Jul
[)Aug
Sep
Oct [ jX
Nov
Dec
Thermostat Schedule: HERS 2006 Reference
Hours,
Schedule Type
1
2
3
4
5
6
7
8
9 10
11
12
Cooling (WD) AM
78
78
78-
78
78
78
78
78
80 80
80
SO
PM
80
80
78
78
78
78
78
78
78 78
78
78
Cooling (WEH) AM
78
78
78
78
78
78
78
78 .
78 78
78
78
' PM
78
78
78
78
78
78
78
78
78 78
78
78
Heating (WD) AM
66
66
'66
66
66
68
68 .68
68 68
68
68
PM
68
68
68
68.
68
68
68
68
68 68
66
66
Heating (WEH) AM
66
66
66
66
66
68
68
68
68 68
68
68
PM
68
68
68
68
68
68
68
68.
68 68
66
66
MASS
Mass Type
Area '
Thickness
Furniture Fraction
Space
- Default(8 lbs/sq.ft,
oft'
O ft
0.3
MASTERBEDROO
Default(8 lbs/sq.ft.
ft2
ft
0.3
WIC
Default(81bs/sq.ft.
ft2
ft
0.3
MASTER BATH
Oefault(8lbs/sq.ft.
ft2
ft
0.3
M. BATH
Default(8 lbs/sq.ft.
ft2
ft
0.3
LAUDRY
Defau(t(8lbs/sq.ft.
ft2
ft
0.3
BEDROOM
Defaull(8 Ibs/sq.ft.
ft
ft
0.3
DINING/GREAT R
Default(8 lbs/sq.ft.
ft2
ft
0.3
KITCHEN
Default(8 lbs/sq.ft.
ft2
ft
0.3
BATH
- Default(8lbs/sq.ft.
'ft2
ft
'0.3
HALL
Default(8 lbs/sq.ft.
ft2
ft
0.3
FOYER
- Default(8 lbstsft
ft'
ft
0.3
BEDROOM
4/21/202010:24 AM EnergyGauge® USA 6.0.02 (Rev.1)- FI6Res2017 FBC 6th Edition (2017) Compliant Software Page 5 of 5
2017 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
TABLE 402.4.1.1
AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
Project Name: WYNNE THE GRAND CARLTON Builder Name: WYNNE BUILDING COPR.
Street Permit Office: ST. LUCIE COUNTY
City, State, Zip: FT. PIERCE, FL, Permit Number.
z
Owner: WYNNE BUILDING CROP Jurisdiction: ST. LUCIE COUNTY
tu
Design Location: FL, Fort Pierce
o
COMPONENT
AIR BARRIER CRITERIA
INSULATION INSTALLATION CRITERIA
General
A continuous air barrier shall be installed In the building envelope.
Air -permeable insulation shall
requirements
The exterior thermal envelope contains a continuous air barrier.
not be used as a sealingmaterial.
Breaks or joints in the air barrier shall be sealed.
Ceiling/attic
The air barrier in any dropped ceiling/soffit shall be aligned with
The insulation in an droppedg /soffit
ceiling/soffit
the insulation and any gaps in the air barrier shall be sealed.
shall be aligned with the air barrier.
•
Access openings, drop down stairs or knee wall doors to
unconditioned attic spaces shall be sealed.
Walls
The junction of the foundation and sill plate shall be sealed.
Cavities within corners and headers of frame walls
The junction of the top plate and the top of exterior walls shall be
shall be insulated by completely filling the cavity
sealed.
with a material having a thermal resistance of R-3
Knee walls shall be sealed.
per inch minimum.
Exterior thermal envelope insulation for framed
walls shall be installed in substantial contact and
continuous alignment with the air barrier.
Windows, skylights
The space between window/doorjambs and framing, and
and doors
skylights and framing shall be sealed.
Rim joists
Rim joists shall include the air barrier.
Rim joists shall be insulated.
Floors
The air barrier shall be installed at any exposed edge of
Floor framing cavity insulation shall be installed to
(including
Insulation.
maintain permanent contact with the underside of
above -garage
subfloor decking, or floor framing cavity insulation
and cantilevered
..
shall be permitted to be in contact with the top side
floors)
of sheathing, or continuous insulation installed on
the underside of floor framing and extends from the
bottom to the top of all perimeter floor framing
members.
Crawl space walls
Exposed earth In unvented crawl spaces shall be covered with
Where provided Instead of floor insulation, insulation
a Class I vapor retarder with overlapping joints taped.
shall be permanently attached to the crawlspace
Shafts, penetrations
;Duct shafts, utility penetrations, and flue shafts opening to
exterior or unconditioned space shall be sealed.
Batts in narrow cavities shall be cut to fit,�or narrow
Narrow cavities
cavities shall be filled by insulation that on
installation readily conforms to the available cavity
spaces.
Garage separation
Air sealing shall be provided between the garage and conditioned spa
s.
Recessed lighting
Recessed light fixtures installed in the building thermal envelope
Recessed light fixtures installed in the building
shall be sealed to the drywall.
thermal envelope shall:be air tight and IC rated.
Plumbing and wiring
Batt insulation shall be cut neatly to fit around wiring
and plumbing in exterior walls, or insulation that on
installation readily conforms to available space shall
extend behind piping and wijdno
Shower/tub
The air barrier installed at exterior walls adjacent to showers and
'Exterior walls adjacent to showers and tubs shall
on exterior wall
tubs shall separate them from the showers and tubs.
be Insulated.
Electrical/phone box or
The air barrier shall be installed behind electrical or communication
exterior walls
boxes or air -sealed boxes shall be installed.
HVAC register boots
HVAC register boots that penetrate building thermal envelope shall
be sealed to the sub -floor or drywall.
Concealed
When required to be sealed, concealed fire sprinklersshall only be
sprinklers
sealed In a manner that is recommended by the manufacturer.
Caulking or other adhesive sealants shall not be used to fill voids
a. In addition, Inspection of log walls shall be in accordance with the provisions of ICC-000.
4/21/2020 10:25 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1
20i7 EPL DISPLAY CARD
ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 97
The lower the Energy Performance Index, the more efficient the home
1. New home or, addition
1. New (From Plans)
12. Ducts, location & insulation level
a) Supply ducts R
6.0
2. Single-family or multiple -family
2. Single-family
b) Return ducts R
6.0
c) AHU location
Attic
3. No. of units (if multiple -family)
3.
1
4. Number of bedrooms
4.
2
13. Cooling system: Capacity
34.8
a) Split system SEER
15.0
5. Is this a worst case? (yes/no)
5.
Yes
b) Single package SEER
c) Ground/water source SEER/COP
6. Conditioned floor area (sq. ft.)
6.
1446
d) Room unit(PTAC EER
e) Other
7. Windows, type and area
a) U-factor:(weighted average)
7a.
0.543
b) Solar Heat Gain Coefficient (SHGC)
7b.
0.250
14. Heating system: Capacity
34.8
c) Area
7c.
141.3
a) Split system heat pump HSPF
8.5
b) Single package heat pump HSPF
8. Skylights
c) Electric resistance COP
a) U-factor:(weighted average)
8a.
NA
d) Gas furnace, natural gas AFUE
b) Solar Heat Gain Coefficient (SHGC)
8b.
NA
e) Gas furnace, LPG AFUE
f) Other
9. Floor type, insulation level:
a) Slab -on -grade (R-value)
9a.
0.0
b) Wood, raised (R-value)
9b.
15. Water heating system
c) Concrete, raised (R-value)
9c.
a) Electric resistance EF
0.97
b) Gas fired, natural gas EF
10. Wall type and insulation:
c) Gas fired, LPG EF
A. Exterior:
d) Solar system with tank EF
1. Wood frame (Insulation R-value)
10A1.
e) Dedicated heat pump with tank EF_
2. Masonry (Insulaton R-value)
10A2.
4.1
f) Heat recovery unit HeatRec%
B. Adjacent:
g) Other
1. Wood frame (Insulation R-value)
10131.
11.0
2. Masonry (Insulation R-value)
10132.
16. HVAC credits claimed (Performance Method)
11. Ceiling type and insulation level
a) Ceiling fans
a) Under attic
11a.
30.0
b) Cross ventilation
No
' b) Single assembly
11b.
c) Whole house fan
No
c) Knee walls/skylight walls
11c.
19.0
d) Multizone cooling credit
d) Radiant barrier installed
11d.
No
e) Multizone heating credit
f) Programmable thermostat
Yes
*Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT
I certify that this home has complied with the Florida Building Code, Energy Conservation, through the above energy
saving features which will be installed (or exceeded); in this home before final inspection. Otherwise, a new EPL
display card will be completed based on installed code compliant features.
Builder Signature: Date:
Address of New Home\n \�O�Q\4 S City/FL Zip: FT. PIERCE.
4/21/2020 10:24:57 AM EnergyGauge® USA 6.0.04 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1