Loading...
HomeMy WebLinkAboutEnergy CodeFORM R405-2017 FLORIDA ENERGYEFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method _ Project Name: WYNULTHE GRAND CAR Builder Name: WYNNE BUILDING CORR. � Street: \r \�, ��e\�A_Q G PermitOffice: ST. LUCIE COUNTY City, State, Zip: FT. PIERCE, FL, ..J Permit Number: Owner. WYNNE BUILDING CROP Judsdiction: ST. LUCIE COUNTY Design Location: FL, Fort Pierce County: St. Lucie (Florida Climate Zone 2 ) 1. New construction or existing New (From Plans) 9. Wall Types (1442.0 sqft.) Insulation Area 2. Single family or multiple family Single-family a. Concrete Block - Int Insul, Exterior R=4.1' 1250.00 ft- 3. Number of units, if multiple family 1 b. Frame - Wood, Adjacent c N/A R=11.0 192.00 ft= R= ft= 4. Number of Bedrooms 2 d. N/A R= ft= 5. Is this a worst case? YB5 10. Ceiling Types (1476.0 sqft.) Insulation Area a. Under Attic (Vented) R=30.0' 1446.00 ft= 6. Conditioned floor area above grade (W) 1446 b. Knee Wall (Vented) R=19.Q 30.00 ft= Conditioned floor area below grade (ft=) 0 0• WA R= ft 7. Windows(141.3 sqft.) Description Area 11. Ducts a. Sup: Attic, Ret: Attic, AH: Attic R ft= 6 250 a. U-Factor: Sgl, U=0.54 101.25 ft= SHGC: SHGC=0.25 b. U-Factor: Sgl, U=0.55 40.00 ft= 12. Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.25 a. Central Unit 34.8 SEER:15.00 c. U-Factor. N/A ft= SHGC: d. U-Factor. N/A 13. Heating systems kBtulhr Efficiency ft2 a. Electric Heat Pump 34.8 HSPF:8.50 SHGC: Area Weighted Average Overhang Depth: 3.832 ft. Area Weighted Average SHGC: 0.250 14. Hot water systems 8. Floor Types (1445.5 sqft.) Insulation Area a. Electric Cap:.50 gallons a. Slab -On -Grade Edge Insulation R=0.0 1445.50 ft' b. Conservation features EF: 0.970- b. N/A R= ft= None d. N/A R= ft. 15. Credits Patel Glass/Floor Area: 0.098 Total Proposed Modified Loads: 46.69 PASS Total Baseline Loads: 48.09 I hereby certify that the plans and specifications covered by Review of.the plans and FOESTa this calculation are in compliance with the Florida Energy Code. specifications covered by this indicates 0 9,n calculation compliance<_ with the Florida Energy Code. 1. ;ur,,.. !@ �O PREPARED BY., Before construction is completed c+ DATE: - 4-21-20 this building will be inspectedfor compliance with Section 553.908 ♦ o I hereby certify that this building, as designed, is in compliance Florida Statutes. ' with the Florida Energy Code. y'Opyy OWNER/ N^ - ' BUILDING OFFICIAL: DATE: DATE: Compliance requires certification by th an lamznit+�yftupsttiynccordance a air handler enclosure qualifies as certified cereqctorysealeicesa A accorBar den i1. 401. Compliance requires an Air Barrier d In, u pe t o he with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 CHH50, f(�QQ2,4,1 21 FOR ED CODE COMPLIANCE FT. LUCIE COUNTY 4/21/2020 10:24 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (20 ;)) m plant Software Page 1 of 5 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT PROJECT .Title: WYNNE THE GRAND CARL .Bedrooms: 2 Address Type: Street Address Building Type: User Conditioned Area: 1446 Lot # Owner Name: WYNNE BUILDING CROP Total Stories: 1 Block/Subdivision: # of Units: 1 Worst Case: Yes PlatBook: Builder Name: WYNNE BUILDING COPR. Rotate Angle: 180 Street:, Permit Office: ST. LUCIE COUNTY Cross Ventilation: No County: St. Lucie Jurisdiction: ST. LUCIE COUNTY Whole House Fan: No City, State; Zip: 'FT.PIERCE, Family Type: Single-family, FL, New/Existing: New (From Plans) Comment: CLIMATE Design Temp Int Design Temp Heating Design Daily Temp V Design Location TMY Site 97.5�% 2.5 % Winter Summer Degree. Days Moisture Range FL, Fort Pierce FL VERO_BEACH_MUNI 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume 1 Entire House 1446 11568 SPACES Number Name Area Volume Kitchen Occupants Bedrooms Infil ID Finished Cooled. Heated 1 BEDROOM 301 2408 No 0 1 1 Yes Yes Yes 2 WIC 63 504 No 0 1 No Yes Yes 3. M.BATH 56 448 No 0 1 Yes Yes Yes 4 KITCHEN 192 1536 Yes 0 1 No Yes Yes 5 BATH 45 360 No 0 1 Yes Yes Yes 6 BEDROOM 2 204 1632 No 0 1 1 Yes Yes Yes 7 ENTRY 55 440 No 0 1 Yes Yes Yes 8 LAUNDRY 42 336 , No 0 1 Yes Yes Yes 9 GREAT/DINING. 488 3904 No 0 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile . Wood Carpet 1 Slab -On -Grade Edge Insulatio BEDROOM 52 ft 0 301 ft' ____ 0 1 0 2 Slab -On -Grade Edge Insulatio WIC 1 ft 0 63 ft' ____ 0 1 0 3 Slab -On -Grade Edge Insulatio M. BATH 811 0 56 ft- —_ 0 1 0 4 Slab -On -Grade Edge Insulatio KITCHEN 1 ft 0 192 ft' ____ 0 1 0 5 Slab -On -Grade Edge Insulatio BATH 5 ft 0 45 ft' __ 0 1 0 6 Slab -On -Grade Edge Insulatio BEDROOM 2 32.2 ft 0 203.5 IF ___ 0 1 0 7Slab-On-Grade Edge Insulatio ENTRY 7 ft 0 55 ft' ___ 0 1 0 4/21/2020 10:24 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6lh Edition (2017) Compliant Software Page 2 of 5 FORM R405-2017 INPUT SUMMARY. CHECKLIST REPORT FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 8 Slab -On -Grade Edge Insulatio LAUNDRY Eft 0 42 ft2 0 1 0 9 Slab -On -Grade Edge Insulatio GREAT/DINING 46 tt 0 488 ft2 ___ 0 1 0 ROOF / - Roof Gable Roof Red Solar SA Emitt Emitt Deck Pitch V # Type Materials Area Area Color Barr Absor. Tested Tested Insul. (deg) 1 Gable or Shed Metal. 1524 ft2 240 ft2 Light N 0.6 No 0.9 No 0 18.4 ATTIC / V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Vented 150 1446 fP N N CEILING. # Ceiling Type Space - R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic (Vented) BEDROOM. 30 Blown 301 ft2 0.1 Wood 2 Under Attic (Vented) WIC 30- Blown 63ft2 0.1 Wood 3 Under Attic (Vented) M.BATH. 30 Blown 56ft2 0.1 Wood 4 Under Attic (Vented) KITCHEN 30 Blown 192 ft2 0.1 Wood 5 Under Attic (Vented) BATH 30 Blown 45 ft2 0.1 Wood 6 Under Attic (Vented) BEDROOM 30 Blown 204 ft2 0.1 Wood 7 Under Attic (Vented) ENTRY 30 Blown 55 ft2 0.1 Wood 8 Under Attic (Vented) LAUNDRY 30 Blown 42 ft2 0.1 Wood _ 9 Under Attic (Vented) GREAT/DINING 30 Blown 486 ft2 0.1 Wood 10 Knee Wall (Vented) GREAT/DINING 19 Blown 30 ft2 0.11 Wood WALLS Adjacent Space Cavity Width,. Height Sheathing Framing Solar Below a _ 1 NE=>SW Exterior Concrete Block - Int InsuBEDRO0M 4.1 10 0 8 0 80.0 ft2 0 0 0.4 0 2 SW=>NE Exterior Concrete Block - Int InsLBEDR00M 4.1 28 0 8 0 224.0 ft2 0 0 0.4 0 _ 3 _NW=>SE Exterior Concrete Block- Int InsdBEDR00M 4.1 14 0 8 0 112.0 ft2 0 0 0.4 0 _ 4 SW=>NE Exterior Concrete Block - Int Insul M. BATH 4.1 8 0 8 0 64.0 ft2 0 0 0.4 0 5. NE=>SW Exterior Concrete Block - Int Insul BATH 4.1 5 0 8 0 40.0 ft2 0 0 0.4 0 _ 6 NE=>SW Exterior Concrete Block - Int InsBIEOROOM2 4.1 16 0 8 0' 128.0 ft2 0 0 0.4• 0 _ 7 SE=>NW Exterior Concrete Block - Int InsEEDROOM 2 4.1 10. 0 8 0 80.0 ft2 0 0 0.4 0 _ 8 S=>N Exterior Concrete Block - Int InsBEDROOM 2 4.1 4 9 8 0 34.0 ft2 0 0 0.4 0 9 SW=>NE Exterior Concrete Block- Int InsElEDROOM 2 4.1 2 0 8 0 16:0 ft2 0 0 0.4 0 _ 10 SE=>NW Exterior Concrete Block - Int Insul ENTRY 4.1 6 10 8 0 48.0 ft2 0 0 0.4 0 _ 11 SW=>NE Exterior Concrete Block - Int Insul ENTRY 4.1 1 0 8 0 8.0 ft2 0 0 0.4 0 12 SW=>NE Exterior Concrete Block - Int InsuLAUNDRY 4.1 6 0 8 0 48.0 ft2 0 0 0.4 0 _ 13 NE=>SW Exterior Concrete Block -'Int Inst3REAT/DINI 4.1 26 0 8 0 208.0 ft2 0 0 0.4 0 14 NW=>SE Exterior Concrete Block - Int InstOREAT/DINI 4.1 20 0 8 0 160.0 ft2 0 0 0.4 0 4/21/2020 1024 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 3 of 5 FORM R405-2017 IAIPIIT SI IMMAPV r_u=rtrn reT oconor WALLS Adjacent space Cavity Width Height .Sheathing Framing Solar Below 0 15 N=>S Garage Frame- Wood KITCHEN 11 24 8 192.0 ft- - 0.23 0.4 0 DOORS # Omt Door Type Space Storms U-Value Ft Width Height In Ft In Area 1 SE=>NW Insulated ENTRY None .39 3 1 6 8 20.6ft- -WINDOWS Orientation shown is the entered orientation. => changed to Worst Case. Wall V # Ornt ID Frame 1 NW=>SE 3 Metal 2 SW=>NE 4 Metal 3 SE=>NW 7 Metal 4 NE=>SW 13 Metal 5 NW=>SE14 Metal Overhang Panes -NFRC U-Factor SHGC Imp Area Depth Separation Int Shade. Low-E Single Yes 0.54 0.25 N 32.9 ft' 1 ft 0 in 1 ft 5 in Drapes/blinds Low-E Single Yes 0.54 0.25 N 6.9 ' 1 ft 0 in 1 ft 51n None ft Low-E Single Yes 0.54 0.25 N 24.0 ft' 6 ft 0 in 1 8 5 in None. Low-E Single Yes 0.54 0.25 N 37:5 ft' 1 ft 0 in 1 ft 5 in None Low-E Single Yes 0.55 0.25 N 40.0 ft' 8 ft 0 In 1 ft 5 in Drapes/blinds Screening Exterior 5 None None None Exterior 5 GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 315 ft2 315 ft- 24ft 8ft 11 INFILTRATION # Scope Method SLA ,CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000356 1349.6 74.09 139.34 .1233 7 HEATING SYSTEM # System Type Subtype Speed Efficiency Capacity Block Ducts 1 Electric Heat Pump/ Split Singl HSPF:8.5 34.8 kBtu/hr 1 sys#1 COOLING SYSTEM. # System Type Subtype Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unitl Split Singi SEER:15 34.8 kBtu/hr cfm 0.8 1 sys#1 HOT WATER SYSTEM # System Type Subtype Location EF Cap Use SetPnt Conservation 1 Electric None Garage , 0.97 50 gal 60.9 gal 120 deg None 4121/2020 10:24 AM £nergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 4 of 5 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT SOLAR HOT WATER SYSTEM FSEC Collector Storage Cart # Company Name System Model # Collector Model # Area Volume FEF None None ft2 DUCTS / — Supply-- — Return -- Air CFM 25 CFM25 HVAC # V # Location R-Value Area Location Area Leakage Type Handler TOT OUT ON RLF Heat Cool 1 Attic 6 250ft2. Attic 65 ft2 Default Leakage Attic (Default) (Default) 1 1 `TEMPERATURES Programable Thermostat: Y Ceiling Fans: Cooling Jan Feb Venting Jan Feb Mar Mar Apr May Jun (X� [ ] Jul [X� [ ] Aug Sep fr)(') Dec ' l l lxl ANov pr May Jun [) Jul [)Aug Sep Oct [ jX Nov Dec Thermostat Schedule: HERS 2006 Reference Hours, Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 78 78- 78 78 78 78 78 80 80 80 SO PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78 78 . 78 78 78 78 ' PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating (WD) AM 66 66 '66 66 66 68 68 .68 68 68 68 68 PM 68 68 68 68. 68 68 68 68 68 68 66 66 Heating (WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68. 68 68 66 66 MASS Mass Type Area ' Thickness Furniture Fraction Space - Default(8 lbs/sq.ft, oft' O ft 0.3 MASTERBEDROO Default(8 lbs/sq.ft. ft2 ft 0.3 WIC Default(81bs/sq.ft. ft2 ft 0.3 MASTER BATH Oefault(8lbs/sq.ft. ft2 ft 0.3 M. BATH Default(8 lbs/sq.ft. ft2 ft 0.3 LAUDRY Defau(t(8lbs/sq.ft. ft2 ft 0.3 BEDROOM Defaull(8 Ibs/sq.ft. ft ft 0.3 DINING/GREAT R Default(8 lbs/sq.ft. ft2 ft 0.3 KITCHEN Default(8 lbs/sq.ft. ft2 ft 0.3 BATH - Default(8lbs/sq.ft. 'ft2 ft '0.3 HALL Default(8 lbs/sq.ft. ft2 ft 0.3 FOYER - Default(8 lbstsft ft' ft 0.3 BEDROOM 4/21/202010:24 AM EnergyGauge® USA 6.0.02 (Rev.1)- FI6Res2017 FBC 6th Edition (2017) Compliant Software Page 5 of 5 2017 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: WYNNE THE GRAND CARLTON Builder Name: WYNNE BUILDING COPR. Street Permit Office: ST. LUCIE COUNTY City, State, Zip: FT. PIERCE, FL, Permit Number. z Owner: WYNNE BUILDING CROP Jurisdiction: ST. LUCIE COUNTY tu Design Location: FL, Fort Pierce o COMPONENT AIR BARRIER CRITERIA INSULATION INSTALLATION CRITERIA General A continuous air barrier shall be installed In the building envelope. Air -permeable insulation shall requirements The exterior thermal envelope contains a continuous air barrier. not be used as a sealingmaterial. Breaks or joints in the air barrier shall be sealed. Ceiling/attic The air barrier in any dropped ceiling/soffit shall be aligned with The insulation in an droppedg /soffit ceiling/soffit the insulation and any gaps in the air barrier shall be sealed. shall be aligned with the air barrier. • Access openings, drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Walls The junction of the foundation and sill plate shall be sealed. Cavities within corners and headers of frame walls The junction of the top plate and the top of exterior walls shall be shall be insulated by completely filling the cavity sealed. with a material having a thermal resistance of R-3 Knee walls shall be sealed. per inch minimum. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Windows, skylights The space between window/doorjambs and framing, and and doors skylights and framing shall be sealed. Rim joists Rim joists shall include the air barrier. Rim joists shall be insulated. Floors The air barrier shall be installed at any exposed edge of Floor framing cavity insulation shall be installed to (including Insulation. maintain permanent contact with the underside of above -garage subfloor decking, or floor framing cavity insulation and cantilevered .. shall be permitted to be in contact with the top side floors) of sheathing, or continuous insulation installed on the underside of floor framing and extends from the bottom to the top of all perimeter floor framing members. Crawl space walls Exposed earth In unvented crawl spaces shall be covered with Where provided Instead of floor insulation, insulation a Class I vapor retarder with overlapping joints taped. shall be permanently attached to the crawlspace Shafts, penetrations ;Duct shafts, utility penetrations, and flue shafts opening to exterior or unconditioned space shall be sealed. Batts in narrow cavities shall be cut to fit,�or narrow Narrow cavities cavities shall be filled by insulation that on installation readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spa s. Recessed lighting Recessed light fixtures installed in the building thermal envelope Recessed light fixtures installed in the building shall be sealed to the drywall. thermal envelope shall:be air tight and IC rated. Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring and plumbing in exterior walls, or insulation that on installation readily conforms to available space shall extend behind piping and wijdno Shower/tub The air barrier installed at exterior walls adjacent to showers and 'Exterior walls adjacent to showers and tubs shall on exterior wall tubs shall separate them from the showers and tubs. be Insulated. Electrical/phone box or The air barrier shall be installed behind electrical or communication exterior walls boxes or air -sealed boxes shall be installed. HVAC register boots HVAC register boots that penetrate building thermal envelope shall be sealed to the sub -floor or drywall. Concealed When required to be sealed, concealed fire sprinklersshall only be sprinklers sealed In a manner that is recommended by the manufacturer. Caulking or other adhesive sealants shall not be used to fill voids a. In addition, Inspection of log walls shall be in accordance with the provisions of ICC-000. 4/21/2020 10:25 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1 20i7 EPL DISPLAY CARD ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 97 The lower the Energy Performance Index, the more efficient the home 1. New home or, addition 1. New (From Plans) 12. Ducts, location & insulation level a) Supply ducts R 6.0 2. Single-family or multiple -family 2. Single-family b) Return ducts R 6.0 c) AHU location Attic 3. No. of units (if multiple -family) 3. 1 4. Number of bedrooms 4. 2 13. Cooling system: Capacity 34.8 a) Split system SEER 15.0 5. Is this a worst case? (yes/no) 5. Yes b) Single package SEER c) Ground/water source SEER/COP 6. Conditioned floor area (sq. ft.) 6. 1446 d) Room unit(PTAC EER e) Other 7. Windows, type and area a) U-factor:(weighted average) 7a. 0.543 b) Solar Heat Gain Coefficient (SHGC) 7b. 0.250 14. Heating system: Capacity 34.8 c) Area 7c. 141.3 a) Split system heat pump HSPF 8.5 b) Single package heat pump HSPF 8. Skylights c) Electric resistance COP a) U-factor:(weighted average) 8a. NA d) Gas furnace, natural gas AFUE b) Solar Heat Gain Coefficient (SHGC) 8b. NA e) Gas furnace, LPG AFUE f) Other 9. Floor type, insulation level: a) Slab -on -grade (R-value) 9a. 0.0 b) Wood, raised (R-value) 9b. 15. Water heating system c) Concrete, raised (R-value) 9c. a) Electric resistance EF 0.97 b) Gas fired, natural gas EF 10. Wall type and insulation: c) Gas fired, LPG EF A. Exterior: d) Solar system with tank EF 1. Wood frame (Insulation R-value) 10A1. e) Dedicated heat pump with tank EF_ 2. Masonry (Insulaton R-value) 10A2. 4.1 f) Heat recovery unit HeatRec% B. Adjacent: g) Other 1. Wood frame (Insulation R-value) 10131. 11.0 2. Masonry (Insulation R-value) 10132. 16. HVAC credits claimed (Performance Method) 11. Ceiling type and insulation level a) Ceiling fans a) Under attic 11a. 30.0 b) Cross ventilation No ' b) Single assembly 11b. c) Whole house fan No c) Knee walls/skylight walls 11c. 19.0 d) Multizone cooling credit d) Radiant barrier installed 11d. No e) Multizone heating credit f) Programmable thermostat Yes *Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT I certify that this home has complied with the Florida Building Code, Energy Conservation, through the above energy saving features which will be installed (or exceeded); in this home before final inspection. Otherwise, a new EPL display card will be completed based on installed code compliant features. Builder Signature: Date: Address of New Home\n \�O�Q\4 S City/FL Zip: FT. PIERCE. 4/21/2020 10:24:57 AM EnergyGauge® USA 6.0.04 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1