Loading...
HomeMy WebLinkAboutElectrical Building Quote,/ ZW5*rA7 EfA' 5T PREERST CONCRETE BUILDING SYSTEMS 3851 17" St. Northport, AL 35476 Toll Free: (800) 342-3274 Phone: (205) 333-8000 Fax (205) 333-0181 Website: www.aesprecast.com email: sales@aesprecast.com Quote Ref No.120320-14-01-R5 RE: Electrical Buildinq Quote To: Charles Wainer Phone: 954-667-9119 Date: 02-13-2013 With: CNGas Fax: From: Marty B. Wilson Location: Miami Gardens, FL '' Email: Charles(afcngasusa.com Pages: 2 Scope of Work (SOW): AES Precast Company, Inc. will manufacture and guarantee the following specified building, install all of the following features, and deliver to the specified site. Building will be delivered complete and ready to set. Model AES-915-OC Precast Concrete Building to Include: Per AES Specs: 1. Lavout: 1.1. Exterior Dimensions: 9'-0"W x 15'-01 x 9'-2"H 1.2. Interior Dimensions: 8'4"W x 14'-4"L x 8'-2"H (8'-0"W x 14'-0"L x 8'-0"H after interior finish by others) 2. Interior: FT Walls & Ceiling: Smooth Concrete Finish 2.2. Floor: Smooth Concrete Finish, Painted with Epoxy, Gray 3. Exterior. 3.1. Walls: Concrete with Simulated Split Faced Block, Sealed and Stained, Choice of Color 3.2. Roof: Smooth Trowel Finish with HydroStop Roofing Material, White 4. Doors (Per Sheet At00): 4.1. (1) SINGLE 3'0" x TO" 16 Gauge Steel Insulated wl 14 Gauge Cast -in -Place Frames, Galvanized, Primed & Painted 4.2. NRP Stainless Steel Hinges 4.3. Hydraulic Door Closer 4.4. Mortise Lockset with Lever 4.5. Door Bottom Sweep 4.6. Weatherstripping 4.7. Threshold 4.8. Lock Guard 4.9. Kick Plate 4.10. Drip Cap 5. Electrical: 5.1. NIA 6. HVAC: 6.1 (1)1-ton AIC Unit, BARD, with Thermostat, MOUNTED 7. Miscellaneous: 7.1. Any required openings must be approved before manufacturing begins. AES-17MEATr PRECRST CONCRETE BUILDING SYSTEMS Quality Assurance: 3851 171 St. Northport, AL 35476 TO Free: (800) 342-3274 Phone: (205) 333-8000 Fax (205) 333-0181 Website: www.aesyrecast.com email: sales@aesprecast.corn • International Building Code —2009 • National Electrical Code —2011 • Florida Building Code —2007 • ACI-318-2008, "Building Code Requirements for Reinforced Concrete". • ASCE-7-2008 "Minimum Design Loads for Buildings and Other Structures" • UL-752 Test Method Level Four (4) for Bullet Resistance certified by an Independent Structural Engineer • Concrete Reinforcing Institute, "Manual of Standard Practice" • PCI Design Handbook— 69, Edition • Steel Construction Manual —AISC 360-05 • ADA Standards —28 CFR Part 36 -1994 Structural Specifications: • Concrete: Steel -reinforced, polypropylene fiber reinforced, 5000 PSI minimum 28-day compressive strength, air -entrained AST( 0) Walls & Roof. 2'HoorF' ire Ra a f� • Walls 4" (pus 2" Ins_u19tionrFloor 6", Roof 4" at edge and 6" at center (plus 2" Insulation), giving a 2" slope from center to edge. • Loadings: Wind 150 MPH Exposure "C", Roof 60 PSF, Floor 250 PSF, Seismic Av=0.4 • Reinforcing Steel: ASTM A615, grade 60 unless otherwise indicated • Reinforcing Fiber: Polypropylene fiber, Fiber mesh @ 1.5 pounds per cubic yard Caulking: All joints between panels shall be caulked on the exterior and interior surface of the joints. Caulking shall be SIKAFLEX- 1A elastic sealant or equal • Panel Connections: All panels shall be securely weldedtogether with 1/4" thick steel brackets. Steel is to be of structural quality, hot -rolled carbon complying with ASTM A283, Grade C. Cast -in anchors used for panel connections to be Dayton -Superior #F-63, or equal F O , destination (Mlami Gardensjt): $26,50000 Crane Rental for Offloading IS Included. Lifting Bolts for Initial Offloading Included. Weight.=40,000 Lbs. Note: Production schedule is based upon date of Purchase Orders. PLEASE NOTE THAT DRAWINGS ANDIOR QUOTE MAY REQUIRE APPROVAL WITH SIGNATURE BEFORE PRODUCTION. Thank you, Marty B. Wilson. AES Precast Co, Inc. mbwilsontaaesprecast.com 800.342.3274 PaymenttemsNet30. Final electrical and plumbing connections to be made by others as well as site work unless otherwise noted. Contractor must provide level unobstructed area large enough for crane and tractor trailer to park adjacent to pad. Crane must be able to place outriggers within 3'-0' of edge of pad and truck and crane must be able to get sideby-side under their own power. If AES Precast is supplying the crane, no overhead lines or piping maybe within 75' radius of center of pad and no building shall be placed closer than 2-0'to an ezis8ng structure. Firm roadbed with bums that allow 80' lowbed tractor and trailer must be provided directly to site. AES Precast is a GSA Contract Vendor. Price good for 90 days from above date. Standard exterior finish of exposed aggregate will be chosen if no choice is made.