HomeMy WebLinkAboutblower doorEnvelope Leakage Test Report (Blower Door Test)
Residential Prescriptive, Performance or ERI Method Compliance
2017 Florida Building Code, Energy Conservation, 6th Edition
Jurisdiction: Permit #:
,job Information, : <�
Builder: ����omm�unity-.�j�. 1,�,�, Lot:
1 X 60 = 1_ 33 Method for calculating building volume:
CFM(50) Building Vo ume ACH(50) O Retrieved from architectural plans
PASS ❑FAIL Code software calculated
When ACH(50) is less than 3, Mechanical Ventilation O Field measured and calculated
installation must be verified by building department.
sting.'Testingshall be conducted in accordance viit}i AtV511RESNETIICC 380 an reported at a pressure or O.Z inche w.g. (54 Pascals: Testing
Te
'shall be conducted by either individuals:as,deflned in sectibn' 553,993(5),or(7), Florida Statues, or individuals licensed as set forth in'sec
489,105(3)(f), (g); br (i)or an approved third party'A written report of the results of the test shall be signed by the party conducting the test and
provided to the code official. Testing shall be performed at any time'after creation of all penetrations of the 'Wilding 'therrnal envelope. , .
During testing:
1'.Exterior windows and doors, fireplace and stove doors shall be `dosed, but not sealed, beyond the intended weatherstripping orolther infiltratioi
control rneasures
2,Dampers including exhaust, intake, makeup air, back draft and flue dampers shall be closed, but not sealed beyond intended infiltration control
tneaspres.�r,,
3 Interior doors; if installed at the time of the test; shall be,open...�
4.Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed. (
5.Heating and cooling systems,if installed atthe time,of the test, shall be turned off.
6.5upply and"return registers, if installed at the time of the test, shall be fully open.
Testing Company
Company Name: Phone: 5-6( 5b —)--I li
hereby verify that the above Air Leakage sults arp in accordance with the 2017 6th Edition Florida Building Code Energy
Conservation requirements accordinj e co4iance method selected above.
Signature of Tester:
Date of Test: fi�qo
Printed Name of Tester: 1"'7% '
License/Certification #: 9� 4fi Issuing Authority:
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
FORM R405 DUCT LEAKAGE TEST REPORT
PERFORMANCE METHOD
Project Name: r ,'�
if -�,
j
Builder Name: K Hovnanian Homes
Lot or Unit:
Permit Number:
14 if rirf
Street: � � �
City, St te,_Zip:
344
Conditioned Floor Area:
1 �I
Syste., ra:',
1`i ..►,.' ' ,,
Leakage out; ciFnii (outj
Ring Used.
2
3
4
5
Sum of lines 1-6
Conditioned floor area
Total house duct leakage to outdoors expressed as
(Qn,out). divide sum of lines 1-6 by conditioned
floor area to arrive at (Qn,out)
Qn (Out) =
fD
Name Printed:
Frank Costagliola
Company:
Sustainabase
Certification Number:
FSEC - 1514
Test Date: W
a
Place Signaturoelow:
Page 1 of 1