Loading...
HomeMy WebLinkAboutBuilding Planst I P OA \p. g L 38" RAIL 7 ft. 8 BY SEPARATE PERMIT \ \\y in. 33 ft. 8 In. POOL GATES '.. SELF=CLOSING AND +23.5 NAVD SELF.LATCHING. LATCHING DEVICE 54" ABOVE BOTTOM OF THE GATE ft In �POOL EQUIPMENT 7 ft. B In. LOCATION +24 NAVD Z z LOT 7 I W a O a POOLGLIARD ALARMS IN POOL & SPA r UNE pROP�aN REVIEWED FOR BAR COMPLIANCE CODE ST. LUCIE COUNTY BOCC POOLDESIGN.NET File Copy POOLDESIGN.NET 30 S.W. 5th COURT POMPANO BEACH FLA 33060 (954)941-1124 info@swimmingpoolplan.com CERTIFICATE OF AUTHORIZATION N. 9871 DESIGN PER FLORIDA BUILDING CODE 454.2 INCLUDING BUT NOT LIMITED TO 454.2.6.6/R4101.8.1 ENTRAPMENT PROTECTION FOR SUCTION INLETS 454.2.17 RESIDENTIAL SWIMMING BARRIER REQUIREMENTS REVISIONS GENERAL NOTES', 1) PLANS DESIGNED PER 20178th EDITION RBA.RESIDENTIAL CHAPTERS 42 & 46 and ANSI/NSPI 3, ANSI/NSPI 5, ANSI/APSP 7,ANSI/APSP/ICC'15 2)DESIGN IS BASED ON RECOMMENDATIONS FROM SOILPROBE ENGINEERING&TESONG INC. REPORT DATED AUGUST 29M, 2019 IS ATTACHED, ALL RECOMMENDATIONS FOR SITE PREPARATION SHALL BE FOLLOWED PER SOIL REPORT, IF CONDITIONS DIFFER FROM CONDITIONS SPECIFIED ABOVE, THIS ENGINEER SHALL BE NOTIFIED PRIOR TO FURTHER CONSTRUCTION OF THIS PROJECT. 3) ALL CONCRETE SHALL CONFORM TO AQ 1318-11. CONCRETE SHALL HAVE A MINIMUM COMPRESSIVE STRENGTH OF 3,G00 PSI FOR PNEUMATICALLY PLACED CONCRETE (GUNITE! SHOTCRETE) 4) ALL REINFORCING STEEL SHALL BE INTERMEDIATE GRADE DEFORMED BARS OR NEW BILLET STEEL CONFORMING TO A.T.S.M.45. STEEL SHALL BE BENT, LAPPED, AND PLACED IN ACCORDANCE WITH A.C.I. STANDARDS AND SPECIFICATIONS, 5) PIPING. ALL POOL PIPING. SHALL BEAR THE N.S.F,-PW SEAL OF APPROVAL AND SHALL BE SCHEDULE 40 P.V.C. MIN. POOL PIPING TO COMPLY WITH F.SA C. POOL EQUIPMENT TO APPLY TO F.B.C. 6) WATER SUPPLY AND DISPOSAL SHALL BE SO ARRANGED THAT THERE IS NO CROSS CONNECTION WITH A DOMESTIC WATER SUPPLY OR WATER DISPOSAL SYSTEM AND SHALL MEET ALL REQUIREMENTS IN F.B.C. 7) EQUIPOTENTIAL BONDING GRID SHALL BE INSTALLED PER 2014 NEC SECTION 680.28(C) 11111/1°° M ANo I�F 68449 .,®BS10NA 11eN�%% S. M. AKERS F.E. 68449 SITE PLAN TITLE LOT 7 VENETIAN ADMINISTRATION LLC DESCRIPTION 4446 N. HWYAIA FT. P RCE. FL.34949 Scale 1 in = 201t. OIn. DATE 1 /21 /2020 PAGE 1 OF 5 NOTES: IF WATER SOURCE IS A PRIVATE WELL- PRE -FILTER WATER TO FILL SPA ALL METALLIC ITEMS WITHIN 5-0" OF WATER'S EDGE OF SPA TO BE BONDED WITH #8 SOLID INSULATED WIRE (W. listed) FROM POOL STEEL. ALL GROUND WIRES CONNECTED To STEEL WITH BRASS GROUND LUGS...... G.F.I. OUTLET 10' MIN. AND 20' MAX. FROM SPA IF ENCLOSURE IS REQUIRED ADD SCREEN OR FENCE AROUND POOL OR PROPERTY GATES 1'D BE SELF CLOSING AND SELF LATCHING PROVIDE DOOR AND WINDOW ALARMS AS REQUIRED STEEL OVERLAP C 48 TIMES DIAMETER I ESTABLISH THE LOCATION OF ALL UTILITIES AT SPA CONSTRU¢TION SITE AND HOLD MINIMUM CLEARANCE DIMENSIONS ESTABLISHED BY THE LOCAL REGULATORY AGENOYY. ALLOW MIN. 10 HORIZONTAL CLEARANCE FROM OVERHEAD ELECTRIC LINES TO SPA WATER. DECK SHALL HAVE A SLIP RESISTANT FINISH WITH NO SHARP EDGES AND BE POSITIVELY SLOPED FOR DRAINAGE BACKFILLING OF THE POOL SHALL BE DONE CAREFULLY TOASSU E THAT NO DAMAGE TO THE PIPING OCCURS AND BACKFILLING SHALL BE DONE WITH CLEAN SOIL FREE FROM ORGANICS AND DEBRIS AND SHALL BE COMPACTED SO THAT NO VOIDS EXIST PROVIDING A FIRM BEARIN FOR THE DECK ALL PIPING TO BE PVC SCHEDULE 40 MINIMUM AND ALL PRESS RE PIPING AND MAIN DRAINPIPING MUST BE PRESSURE TESTED PRIOR TO GUNITE (CONCRETE) THIS IS NOT A DIVING POOL. SWIMMING POOL FILL HOSE TO BE EQUIPPED WITH VACUUM BRED KER PROVIDE MIN. 42" BARRIER BY OTHERS PER PERMIT #1901-0540 LOT 7 POOLDESIGNNET 4� 3"Q• pjc rw 1 ft. 6 Sit. C POOL DIMENSIONS TAKEN AT WATERLINE POOLDESIGN.NET 30 S.W. 5th COURT POMPANO BEACH FLA 33060 (954)941-1124 info@swimmingpoolplan.com CERTIFICATE OF AUTHORIZATION N. 9871 DESIGN PER FLORIDA BUILDING CODE 454.2 INCLUDING BUT NOT LIMITED TO 4542se /R4101,8.1 ENTRAPMENT PROTECTION FOR SUCTION INLETS 454.2.17 RESIDENTIAL SWIMMING BARRIER REQUIREMENTS REVISIONS GENERAL NOTES, 1) PLANS DESIGNED PER 2017 eth EDITION F.B.C. RESIDENTIAL CHAPTERS 42 & 45 and ANSI/NSPI 3, ANSI/NSPI 5, ANSVAPSP 7,ANSIIAPSP/ICC 15 2)DESIGN IS BASED ON RECOMMENDATIONS FROM SOILPROBE ENGINEERING & TESTING INC. REPORT DATED AUGUST 20th, 2019. IS ATTACHED. ALL RECOMMENDATIONS FOR SITE PREPARATION SHALL BE FOLLOWED PER SOIL REPORT. IF CONDITIONS DIFFER FROM CONDITIONS SPECIFIED ABOVE, THIS ENGINEER SHALL BE NOTIFIED PRIOR TO FURTHER CONSTRUCTION OF THIS PROJECT. 3) ALL CONCRETE SHALL CONFORM TO AO1318-11. CONCRETE SHALL HAVE A MINIMUM COMPRESSIVE STRENGTH OF 3,000 PSI FOR PNEUMATICALLY PLACED CONCRETE (GUNITE/ SHOTCRETE) 4) ALL REINFORCING STEEL SHALL BE INTERMEDIATE GRADE DEFORMED BARS OR NEW BILLET STEEL CONFORMING TO A.T.S.M.15. STEEL SHALL BE BENT, LAPPED, AND PLACED IN ACCORDANCE WITH A.C.I. STANDARDS AND SPECIFICATIONS. 5) PIPING: ALL POOL PIPING SHALL BEAR THE N.S.F: PW SEAL OF APPROVAL AND SHALL BE SCHEDULE 40 P.V.C. MIN, POOL PIPING TOCOMPLYWITH F.B.C. POOL EQUIPMENT TO APPLY TO FS C. 8) WATER SUPPLY AND DISPOSAL SHALL BE SO ARRANGED THAT THERE IS NO CROSS CONNECTION WITH A DOMESTIC WATER SUPPLY OR WATER DISPOSAL SYSTEM AND SHALL MEET ALL REQUIREMENTS iNF.BO. 7) EQUIPOTENTIAL BONDING GRID SHALL BE INSTALLED PER 2014 NEC SECTION 880.28(C) M. A/{ Fq e . o ., .•;��CEtys; No 68449 �* �-0: * ��'♦ T a R i ID P e\�o,�� ON'A 11SNG�va B. M. AKERS P.IE. 68449 LAYOUT PLAN TITLE LOT 7 VENETIAN ADMINISTRATION LLC DESCRIPTION 4446 N. HWY A1A FT. PIERCE FL34949 Scale: 1/4" = V-0" DATE 1/21/2020 PAGE 2 OF 5 Y SUN SHELF W/ SKIMMER I I I I 'BUBBLER FOUNTAIN LINE I =OUNTAINLIGHTCONDUIT— 0 •—•—•+•-----------•-----•—•---' 2" SKIMMER LINEG— POOL LIGHT CONDUIT '--- �•_h_.—._._._._,._._._._._._._._._._._._._._._._._._. 2"VACUUM LINE POOL LIGHT CONDUIT --•—• ------------------------------------------------ 3" POOL MAIN DRAIN LINE 3" SPA MAIN DRAIN LINE 3 SPA LIGHT CONDUIT 0—•_._.----------- _._................ ................ 2-1/2" RETURN LINE—��-------- ----- -------- -------------------------------------------------- �F POOL EQUIPMENT LOCATION TOP OF POOL EQUIPMENT SLAB TO BE INSTALLED AT BASEFLOOD ELEVATION+1' (1 B.4 NA VD) ALL PIPING TO BE PVC SCHEDULE 40 MINIMUM AND ALL PRESSURE PIPING AND MAIN DRAIN PIPINGe MUST BE PRESSURE TESTED PRIOR TO GUNITE (CONCRETE) PROVIDE 5 PIPE DIAMETERS CLEAR LENGTH BEFORE PUMPS ON SUCTION SIDE LABEL ALL VALVES AND PIPES PIPING TO BE INSTALLED 18" MIN BELOW GRADE AND TRENCHES TO BE BACKFILLED W/ CLEAN SAND WELL WATER: IF POOL IS TO BE FILLED WITH WELL WATER PROVIDE PREFILTER WHEN FILLING POOL POOLDESIGN NET PIPING IS SHOWN SPACED FOR CLARITY CONNECT SPA AIR LINE TO EACH THERAPY JET --'F STEP NOTE: LIGHTS MUST BE 3A, pEEP AMBER COLOR AQUASTAR 32CDFUoo( VGB APPROVED MAIN DRAINS I MAXIMUM FLOOR SLOPE ' i R.IN3tt (4) 1-1/2" DIRECTIONAL INLETS HAYWARD W 4001-1/2" CLEANING FITTING WICOVER INSTALLED 6" TO 12" BELOW WATER LINE 12V LED LIGHT A Iw R R - --A --- r------------------------------------ ------ I I I I � ----------------------------------- I I I I -._._._--._.—.—._.—.—._._._._._._._._._._._._._._.� POOL ALARMS ON DOORS AND WINDOWS LEADING TO POOL AREA POOLDESIGNAET 30 S.W. 5th COURT POMPANO BEACH FLA 33060 (954) 941-1124 info@swimmingpoolplan.com CERTIFICATE OF AUTHORIZATION N. 9871 DESIGN PER FLORIDA BUILDING CODE 454.2 INCLUDING BUT NOT LIMITED TO 454.2.6.8 IR4101.6.1 ENTRAPMENT PROTECTION FOR SUCTION INLETS 454.2.17 RESIDENTIAL SWIMMING BARRIER REQUIREMENTS REVISIONS GENERAL NOTES: 1) PLANS DESIGNED PER 20176th EDITION F.B.C. RESIDENTIAL CHAPTERS 42 & 45 and ANSWER 3, ANSUNSPI 5, ANSUAPSP 7,ANSI/APSPACC 15 2)DESIGN IS BASED ON RECOMMENDATIONS FROM SOILPROBE ENGINEERING& TESTING INC. REPORT DATED AUGUST 29th, 2019. IS ATTACHED. ALL RECOMMENDATIONS FOR SITE PREPARATION SHALL BE FOLLOWED PER SOIL REPORT. IF CONDITIONS DIFFER FROM CONDITIONS SPECIFIED ABOVE, THIS ENGINEER SHALL BE NOTIFIED PRIOR TO FURTHER CONSTRUCTION OF THIS PROJECT, 3) ALL CONCRETE SHALL CONFORM TO A,0.1318.11. CONCRETE SHALL HAVE A MINIMUM COMPRESSIVE STRENGTH OF 3,000 PSI FOR PNEUMATICALLY PLACED CONCRETE (GUNITE/ SHOTCRETE) 4) ALL REINFORCING STEEL SHALL BE INTERMEDIATE GRADE DEFORMED BARS OR NEW BILLET STEEL CONFORMING TO A.T.S.M.-15. STEEL SHALL BE BENT, LAPPED, AND PLACED IN ACCORDANCE WITH A.C.I. STANDARDS AND SPECIFICATIONS. 5) PIPING: ALL POOL PIPING SHALL BEAR THE N.S.F.-PW SEAL OF APPROVAL AND SHALL BE SCHEDULE 40 P V.C. MIN. POOL PIPING TO COMPLY WITH F.B.C. POOL EQUIPMENT TO APPLY TO F.B.0 6) WATER SUPPLY AND DISPOSAL SHALL BE SO ARRANGED THAT THERE IS NO CROSS CONNECTION WITH A DOMESTIC WATER SUPPLY OR WATER DISPOSAL SYSTEM AND SHALL MEET ALL REQUIREMENTS IN F.B.C. EQUIPOTENTIAL BONDING GRID SHALL BE INSTALLED PER 2014 NEC SECTION 680.28(C) , 1 Afill. t 0 I *.• No 68449 00. ®✓� 0RtQ. B. M. AKERS P.E. 68449 PIPING PLAN TITLE LOT 7 VENETIAN ADMINISTRATION LLC DESCRIPTION 4446 N. HWYAIA FT. PIERCE FL.34949 Scale: 1/4" = V-0" DATE 1/21/2020 PAGE 3 OF 5 PANEL G.F.1. 3 #121N CONTROLLER CHLORINATOR -L GFI PUMP BREAKERS 3 #121N 112" CONDUIT C22TO 1.5HP AIR BLOWER j 4.5A "Jl BOX 4'MIN. Ell DECK BY OTHERS 1 #8 AWG INSULATED COPPER _ WIRE EPDXY COATED I LIGHT CORD _f (IN CONDUIT) i_.._.._.._.. _.. I F #8 AWG INSULATED COPPER WIRE EPDXY 220V COATED PUMP POOL PUMP ROTOR COMPLIES WITH PILING POOL SEE PILING PLAN BOND CONNECTION PROVED POTTING COMPOUND 12V UNDERWATER ILL APPROVED LIGHT 12"O/C - & VERTICAL _ PLASTER FINISH 12" FLOOR 3HP VS 403.9 FBC iz" o/c BorH WAYS ALL ELECTRICAL PER PENTAIR r DOUBL T 2014 N.E.C. 16A ALL EQUIPMENT TO BE INSTALLED PER MANUFACTURER SPECIFICATIONS ALL METALLIC ITEMS WITHIN 54" OF WATERS EDGE OF POOL TO BE BONDED WITH POOL STEEL OVERLAP @ 46 TIMES DIAMETER #8 SOLID INSULATED WIRE (UL listed) FROM POOL STEEL, ALL GROUND WIRES STRUCTURAL DETAIL CONNECTED TO STEEL WITH BRASS GROUND LUGS ...... G.F.L OUTLET 10' MIN. AND 20' MAX. FROM POOL, 3HP PENTAIR 1-1/2 H.P. VS PUMP RI nWF MIN. CLEAR '� ( FORR FILTER SOLFUTURE ��\\\\\\\\l AR Provide min. IC40 CELL 4 times pipe diam. clear straight length NOTE: WATERBOND FITTING TO BE G BELOW WATERLINE AT ALL TIMES ATER BOND a FITTING P62008 CHECK z �. VALVE 4 Z 2.1/2" SPA 2-112" POOL RETURN JETS z �r U Willi•�� LJ LBENI) PILING STEEL INTO POOL FLOOR TYP, POOL SECTION Scale: nts POOLDESIGNNET 24-8" b 14,-UP =� VGB APPROVED MAIN DRAIN GRATE N SECURED IN PLACE SO TOOLS — ARE REQUIRED FOR REMOVAL MAXIMUM FLOOR SLOPE 1 ft. IN 7ft 1 12" FLOOR WITH R5 0 12" 0/6 BOTH WAYS I DOUBLE MAT 8 z 0 z 2 LEGEND: OR -RETURN LINE -ELEVATION 2-WAY VALVE 3-WAY VALVE - CHECK VALVE ® -BUTTERFLY VALVE p@�y✓q -SKIMMER 1� - VALVE ACTUATOR NTS - NOT TO SCALE AIR BLOWER TO BE INSTALLED ABOVE WATERLINE GRADE BEAMS WITH 8 #5 AND #3 HOOPS @ 12" O/C -ENTRAPMENT 1. TIME SWITCH MUST BE INSTALLED TO ALLOW POOL OWNERS TO RUN THE POOL FILTRATION PUMP ONLY DURING PEAK HOURS Z AQUASTAR 2. POOL FILTRATION PIPING MUST BE SIZED SO THAT MAIN DRAIN 32CDFL101 THE VELOCITY DOES NOT EXCEED SFPS IN THE 316GPM"39FPSRETURN LINE AND SFPS IN THE SUCTION LINE. jjF LOORINSTALLATION 3. FILTER AREA BASED ON S HOUR TURN OVER 4. FILTER PUMPS -A MIN. OF 4 PIPE DIAMETERS SHALL BE INSTALLED BEFORE PUMP. 5. INLET FITTINGS SHALL BE DIRECTIONAL. � 32 -♦' POOL/ SPA MAIN DRAIN DETAIL 8" WALL WITH #4s 12" 0/0 BOTH WAYS SPA SECTION Scale: nts S. PROVIDE A MIN. I In' OF HORIZONTAL OR VERTICAL PIPE BETWEEN FILTER AND HEATER OR DEDICATED SUCTION AND RETURN LINES SHALL BE INSTALLED TO ALLOW FOR FUTURE ADDITION OF SOLAR HEATING EQUIPMENT. 12" FLOOR / WITH #5 _ @ 12" O/C BOTH WAYS DOUBLE MAT GRADEBEAMS WITH 8 #5 AND #3 HOOPS 012" O/C PILINGS 114' TAP CON BOLTS 3" _ LONG (4) LOCATIONS 'AP CON BOLTS - 114" TAP CON BOLTS- 4" THICK CONCRETE SLAB ANCHORAGE DETAIL l � I i POOL i ; PER 20141NEC (880.260 "EQUIPOTENTIAL BONDING GRID"): 0 AWG WIREg 18" TO 24" HORIZONTALLY BEYOND THE #B AWO BARE SOL 0 COPPER BONDING JUMPER SHALL BE INSTALLED IN AT LEAST FOUR (4) LOCATIONS AROUND PERIMETER OF THE POOL OR SPA AND ATTACHED TO DECK STEEL W/ APPROVED GROUND LUGS. EQUIPOTENTIAL BONDING GRID PUMP # 400 3/4" CLEVIS HANGERROD #7 REBAR PIPE '4 SUPPORTS 4O/C 318" THREADED STEEL ROD #400 CLEVIS HANGERS SIZE VARIES W/PIPE SIZE RETURN LINE LOOP 1" PVC UPPORT PIPING 4'4" O/C MAX. WALL SECTION PIPING NTS I_1L11-•311I ONE TYPE ^IZE LOW (GPM) PS MAIN DRAIN LINE 1 3" 1_ 130 5.9 LINE.���130 ETURN LINE. 2.1/2ETURN 8.58.5 HERAPYJ 2-1/2. 130 S/APSP- NE TYPE ISI E PLOW (GPM) PS AIN DRAIN ENE O L 3 1.83 PET LINE 36 2,36 POOLDESIGN.NET 30 S.W. 5th COURT POMPANO BEACH FLA 33060 (954)941-1124 info@swimmingpoolplan.com CERTIFICATE OF AUTHORIZATION N. 9871 DESIGN PER FLORIDA BUILDING CODE 454,2 INCLUDING BUT NOT LIMITED TO 454,Z a /R4101,6.1 ENTRAPMENT PROTECTION FOR SUCTION INLETS 454.2.17 RESIDENTIAL SWIMMING BARRIER REQUIREMENTS REVISIONS GENERAL NOTES: 1) PLANS DESIGNED PER 2017 6th EDITION F.8,C. RESIDENTIAL CHAPTERS 42 & 45 And ANSI/NSPI 3, ANSI/NSPI 51 ANSI/APSP 7,ANSUAPSP/ICC 15 2)DESIGN IS BASED ON RECOMMENDATIONS FROM SOILPROBE j ENGINEERING & TESTING INC. REPORT DATED AUGUST 29th, 2019. IS ATTACHED, ALL RECOMMENDATIONS FOR SITE PREPARATION SHALL BE FOLLOWED PER SOIL REPORT. IF CONDITIONS DIFFER FROM CONDITIONS SPECIFIED ABOVE, THIS ENGINEER SHALL BE NOTIFIED PRIOR TO FURTHER CONSTRUCTION OF THIS PROJECT, 3) ALL CONCRETE SHALL CONFORM TO A.OI 31S41. CONCRETE SHALL HAVE A MINIMUM COMPRESSIVE STRENGTH OF 3,000 PSI FOR PNEUMATICALLY' PLACED CONCRETE (GUNREI SHOTCRETE) 4) ALL REINFORCING STEEL'. SHALL BE INTERMEDIATE GRADE DEFORMED BARS OR NEW BILLET STEEL CONFORMING TO A.T.S,M: 15. STEEL SHALL. BE BENT, LAPPED, AND PLACED IN ACCORDANCE WITH A.C.I. STANDARDS AND SPECIFICATIONS, 5) PIPING! ALL POOL PIPING SHALL BEAR THE N.&.F,-PW SEAL OF APPROVAL AND SHALL BE SCHEDULE 40 P.V.C. MIN. POOL PIPING TO COMPLY WITH IF.B.0 . POOL EQUIPMENT TO APPLY TO F.B.C. 6) WATER SUPPLYAND DISPOSAL SHALL BE SO ARRANGED THAT THERE IS NO CROSS CONNECTION WITH A DOMESTIC WATER SUPPLY OR WATER DISPOSAL SYSTEM AND SHALL MEET ALL REQUIREMENTS IN F.B.C. EQUIPOTENTIAL BONDING GRID SHALL BE INSTALLED PER 2014 NEC SECTION 680, 26(C) i I E N S� T opoi rGNO 68449 �\� 0'• S)F,TE OF tV¢: 'ONA11111111111111 8. M. AKERS P.E. 68449 DETAILS TITLE LOT 7 VENETIAN ADMINISTRATION LLC DESCRIPTION 4446 N. HWYAlA FT. PIERCE FL.34949 Scale: 1/4" = V-0" DATE 1/21/2020 PAGE 4 OF 5 POOLDESIGNNET PILE GROUT MIN. 5000 PSI 0 28 DK 12"FLOOR (13) 16"ROUND AUGER -CAST WITH DOUBLE MAT CONIC. PILINGS 35TON #5sQ12"O/C BOTH WAYS COMPRESSION CAPACITY INSTALLED TO 39 BGL OR REFUSAL 3ft, (BY OTHERS) 111 8 # SIB) — I 16" DIAM. AUGER 1 CAST PILE PROVIDE SONO TUBE TO EXTEND PILE ABOVE GRADE TO POOL SLAB ELEVATION ALL PILES TYP. 1113-8" X 8" HOOPS @ V O/C 0 TOP OF PILE AND 10" O/C @ BALANCE PILING&PADSECTION VIEW NTS LOT 7 1S" DIAM. AUGER CAST P #5 BARS Q 12" C/C BOTH WAYS IN POOL FLOOR POOLDESIGNAET 30 S.W. 5th COURT POMPANO BEACH FLA 33060 (954) 941-1124 info@swimmingpoolplan.com CERTIFICATE OF AUTHORIZATION N. 9871 DESIGN PER FLORIDA BUILDING CODE 454.2 INCLUDING BUT NOT LIMITED TO 45418.6 fR4101.8.1 ENTRAPMENT PROTECTION FOR SUCTION INLETS 454,2.17 RESIDENTIAL SWIMMING BARRIER REQUIREMENTS REVISIONS GENERAL NOTES 1) PLANS DESIGNED PER 20178th EDITION Fa C. RESIDENTIAL CHAPTERS 42& 45 and ANSI/NSPI 3, ANSI/NSPI 5, ANSI/APSP 7,ANSI/APSP/ICC IS 2) THE SITE MUST HAVE UNDISTURBED SAND, ROCK, SAND AND ROCK, WITH A MINIMUM BEARING VALUE OF 1500 PSF. 3) THE FOLLOWING IS DETERMINED BY RATIONAL ANALYSIS, SOIL CONDITIONS IN THIS AREA HAVE BEEN BY PAST EXPERIENCE CAPABLE OF SUPPORTING A POOL AND DECK OF SIMILAR SIZE AND DEPTH. IF CONDITIONS DIFFER FROM CONDITIONS SPECIFIED ABOVE, THIS ENGINEER SHALL BE NOTIFIED PRIOR TO FURTHER CONSTRUCTION OF THIS PROJECT. 4) ALL CONCRETE SHALL CONFORM TO A.CJ 31&11. CONCRETE SHALL HAVE A MINIMUM COMPRESSIVE STRENGTH OF 3,000 PSI FOR PNEUMATICALLY PLACED CONCRETE (GUNITE/SHOTCRETE) 5) ALL REINFORCING STEEL SHALL BE INTERMEDIATE GRADE DEFORMED BARS OR NEW BILLET STEEL CONFORMING TO A.T.S.M.15. STEEL SHALL BE BENT, LAPPED, AND PLACED IN ACCORDANCE WITH A.C.I. STANDARDS AND SPECIFICATIONS, 6) PIPING: ALL POOL PIPING SHALL BEAR THE N.SF-PW SEAL OF APPROVAL AND SHALL BE SCHEDULE 40 P.V.C. MIN. POOL PIPING TO COMPLY WITH F.B.0 POOL EQUIPMENT TO APPLY TO F.B.C, 7) WATER SUPPLY AND DISPOSAL SHALL BE SO ARRANGED THAT THERE IS NO CROSS CONNECTION WITH A DOMESTIC WATER SUPPLY OR WATER DISPOSAL SYSTEM AND SHALL MEET ALL REQUIREMENTS IN F.B.C. 8) EQUIPOTENTIAL BONDING GRID SHALL BE INSTALLED PER 2014 NEC SECTION 680.26(C) ` ee C'EN8F •, eee No 68449 \ o'• OF :� 9: s1rTE O .eeee�� A,C 0 R ""If S /O N A„� 8. M. AKERS P.E. 68449 PILING PAGE TITLE LOT 7 VENETIAN ADMINISTRATION LLC DESCRIPTION 4446 N. HWY A1A FT. PIERCE FL.34949 Scale: 3/8" = 1'-0" DATE 1/21/2020 PAGE 5 OF 5