HomeMy WebLinkAboutblower doorPlanning & Development Seri/iCeS
Building r Code RegulaVon Division
2300 Virginia Ave, Rm 201
Fort Pierce, FL 34982
Phone: 772-462-2-165 Fam 772-462-6443
BLOWER 00c)R TES c C-ORM
Hicuse Infiltration Test Cergificc@e,lop,
Prescrip&e and Perorlmance Meihod
Date. I� I t/ za z.o ) 9 � 6— 0/ 6 b'
} i'errfait:
Contractor:y�
De ✓e
Job address:
Co astrueti®n: d/� New COnstruec[®ra —Complete EXIsting—After Addi ioil
FBouse Infiltration Test Results
CFM (50) _ too s SLC Climate Zone 2
Volume = - ` -- Test Date.- _ i [I
ACH (50) = CFM (50) 3160 / Volume
Mechanical Ven<-'ila=ion required )Fall
less than 3 ^CH
Passing results must be « ACH (50) or less
((/Pass ( )Fail
F6C, Energy
The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 7 air changes per
hour in Climate Zone 1, 2 and 3 air changes per hour in Climate Zones 3 through 8. Testing shall be conducted with a
blower door at a pressure of 0.2 inches w. g. (50 Pascals). Testing shall be conducted by either individuals as defined in
Section 553.993(5) or (7), Florida Statutes or individuals licensed as set forth in Section 489.105 (3)(f), (g) or (i) or an
approved third party. A written report of the results of the test shall be signed by the party conducting the test and
provided to the code official. Testing shall be performed at any time a er creation of all penetrations of the building
thermal envelope. -
EC, Residential
Where the air infiltration rate of a dwelling unit is less than 3 air changes per hour when tested with a blower door at a
Pressure of 0.2 inch w. c. (so Pa) in accordance with Section R402.4.1.2 of the Florida Building Code, Energy Conservation
the dwelling unit shall be provided with whole -house mechanical ventilation in accordance with Section M1507.3.
Testing Comnanv
Company Name: Pro -Duct Services
Address: 1915 Rio Vista Drive, Ft. Pierce, FL 34949
1 hereby ce dy that the above House Infiltration results demonstrate compliance vvith FBC Energy Conservation
requirements in accordance with Sfction R402.4.1.2 Climate Zone).
Signature: "/1 kA A
Printed Name: Martin Klein
License/Certification #i: 5061633