HomeMy WebLinkAboutProject Information+ wrightsofto Project Summary Entire House QUICK CALCS, INC. 317 Sr LUCIE LANE, FORT PIERCE, FL 34948 Phone: 772-46M799 Fax 77248"796 Email: OUICKCALCS@AOL.COM Job: Date: May 14, 2020 By: Weather. Fort Pierce, FL, US Winter Design Conditions Summer Design Conditions Outside db 42 OF Outside db 90 OF Inside db 70 OF Inside db 75 OF Design TD 28 OF Design TD 15 OF Daily range M Relative humidity 50 % Moisture difference 61 gr/lb Heating Summary Sensible Cooling Equipment Load Sizing Structure 36233 Btuh Structure 27343 Btuh Ducts 11641 Btuh Ducts 16695 Btuh Central vent (0 cfm) 0 Btuh Central vent (0 cfm) 0 Btuh (none) (none) Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 47874 Btuh Use manufacturers data n Rate/swing multiplier 0.95 Infiltration Equipment sensible load 41836 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 0 Structure 4512 Btuh Ducts 4671 Btuh Central vent (0 cfm) 0 Btuh Heatingg Cool ingg (none) Area (ft� 3187 3187 Equipment latent load 9183 Btuh Volume (W) 33630 33630 Air changes/hour 0.28 0.15 Equipment Total Load (Sen+Lat) 51019 Btuh Equiv. AVF (cfm) 157 84 Req. total capacity at 0.70 SHR 6.0 ton Heating Equipment Summary Cooling Equipment Summary Make Make Trane Trade Trade TRANE Model Cond 4TTR6061C1 AHRI ref Coil TEM6AOC6OH51++TDR+UF/HRZ AHRI ref 8858422 Efficiency 100 EFF Efficiency 13.0 EER, 16 SEER Heating input 12.8 kW Sensible cooling 40600 Btuh Heating output 43689 Btuh Latent cooling 17400 Btuh Temperature rise 21 OF Total cooling 58000 Btuh Actual airflow 1933 cfm Actual airflow 1933 cfm Air flow factor 0.040 cfm/Btuh Air flow factor 0.044 cfm/Btuh Static pressure 1.00 in H2O Static pressure 1.00 in H2O Space thermostat Load sensible heat ratio 0.83 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. ,� wrighlso_f_t' 2020-May-1408:11:02 Right-Sulte® Universal 2019 19.0.08 RSW8101 Page 1 '4E&EADooumnetslWdghtsog WAC\CICIO RESIDENCE.tup Calc-MJ8 Front Door faces: N WA W N W +• W WAfJN+ j yEyE CC (A P"d v mo py yp� pg mff �_ �_mmm mmmmmm m_m_m_m_ mmmm �n �33� 3 9 $ 3m'd3 Sd3$ ---- �2 S -- - _ inn QMQP-P-PL+ ap PIP P-ap-p- 9. +o o o o o o.. o o o o,0000000000 {({���llpp+mWm(m(m��fmmT+ OmmSfmmT(q(q��(H(m�N(m(m��fHmqmmqqm ,89qpJPE'8WN— mm000(N11000000(TO000��0 �0� 1C- YP Z? �'� •,,FFF£wwwwwmwmm�omm�o 000 � NmN mm ymm gN.mm NWN'm (uq�i f'W�.N'W 1WV f'Wl oq� N�AA O �A A� AAO AAr,A �O AA AAO Oyp�o-mq�,ma.'a(Jm�m c�2 ,+w.mV+.. F.P SV WOIV �WWfViI fO Oi LVIm OO�V®lvil fJ'(J [J m+ .. G Q o� O �VW [TOO�WLWWA �iNWWWOAW NO� w 3'� O W Am Cmp $ v W v J N(J IJ VW(T>WWAiS+N++�OO OOm A O 3O �W(O L�l� (mii 4)000 W OO 001 V ?S O�OI+VW +WW�J�Wtn fO b(ml�iS�mNV O O O 00 O 00 O 00'O 00 O m 00 S O O O 00 w �'^ O O o�W00000W0000O+oOm000 oo � O o� x o qq VIT pp Np + VOO O � O � C N $$gy�m y .SH 000 000 O O O 00'OW OOm 00 000 C �,�( S S Y s q 1N� AN (J W O O O O O (AO m OA00 o O o o Oo O 00 O W 00 A 00 G 00 C w O � K a S c wrightsoft° Right-M Worksheet Job: , Entire House Date: May 142828 By: QUICK CALCS, INC. 317 ST LUME LANE, FORTMERCE, FL 34946 Phone: 772-468-6799 Fax 772466-8706 Emil; QUICKCALCS@AOL.COM 1 Room name HALLWAY POWDER RM walt 0 ft 20 ft 3 Roomoaheight 10.0 ft heat/cool 10.0 ft heeVcad 4 Room dimensions 1.0 x 102.0 It 6.0 x 7.0 ft 5 Room area 102.0 ft' 420 ft' Ty nons�cilm U-value Or HIM Am Load or (BtutVWF) (Btuh/ftj or perimeter (ft) (BtUh) perimeter (ft) (Btuh) Heat I Cod Gross WP/S Heat God Gross WP/S Heat cool 8 W 13A5oes 0.125 n 3.50 1.91 0 0 0 0 0 0 0 0 wa 2 glazing, clr Io 0.580 n 16,24 13.73 0 - 0 0 0 0 0 0 0 2 glazing, clr Iowa 0.680 n 16.24 13.73 0 0' 0 -0 0 0 0 0 2 glazing, clrlowa 0.580 n 16.24 13.73 0 0 0 0 0 0 0 0 11 2 glazing,. cir bw a 0.580 n 16.24 , 13.73 0 0 0 0 0 0 0 0 13A5oes 0. a 3.24 1.91 0 0 0 0 0 0 0 0 2 glazing, clr low-e 0.580580 a 16.24 26.77 0 0 0 0 0 0 0 0 2 glazing, clr law-e 0.580 a 18.24 28.77 0 0 0 0 0 0 0 0 2 glazing, clr Iowa 0.580 a 16,24 29.60 0 0 0 0 0 0 0 0 2 glazing, clr Iowa. 0.580 a 16.24 29.60 0 0 0 0 0 0 0 0 134-5ocs 0.125 a 3.50 1.91 0 0 0 0 0 0 0 0 2 glazing, clr Iowa . 0.580 9 16.24 13.73 0 0. 0 0 0 0 0 0 2 glazing, cir Iowa 0.580 s 16.24 13.73 0 0 0 0 0 0' 0 0 2 glazing, clrbwa 0.580 a 16.24 13.73 0 0 0' 0 0 0' 0 0 2 glazing, clr lcw-e 0.580 s 16.24 ' 13.73 0 0 0. 0 0 0 0 0 :2 glazing, clrbw-e 0.580 s 16.24 .13:73 0 0' 0 0 0 0 0 0 2 glazing, clr Iowa ,. 0.580 s 16.24 13.73 . 0 0 a 'o 0 0 0 0 1N 13450cs 0.125 w 3,60 1.91 0 0 0 0 20 20 70 38 IIL-_--GGG 2 glazing, clr Iowa 0.680 w 16.24 26.77 0 0 0 0 0 0 0 0 2 glazing, cir low-e 0.580 w 16.24 30.46 0 0 0 0 0 0 0 0 2 glazing, clr Iowa 0.580 w 16.24 30.95 0 0 0 0 0 0 0 0 c 16X19-0ad 0.408 - 1.59 1.37 102 102' .162 140 - 42 42 87 67 F 22A-tph 1.358 - 38.02 0.00 102 0 0 0 42 2 76 0 6 c)AED excursion 5 -12 Envelope loss/gain 162 134 213 84 12 a) Infiltration 0 0 34 10 b) Roan lentilation 0 0 0 0 13 internal gains: Occupants @ 230 0 0 0 0 Appliarlceslother 0 200 Subtotal (lire 6 to 13) 162 134 247 294 Less eldemai load 0 0 0 0 Less transfer 0 0 0 0 Redistribution -162 -134 22 18 14 Subtotal 0 0 269 312 15 Dud loads 320/6 61% 0 0 32°/a 81% 88 191 Total roan load 0 0 355 603 Air required (efm) 0 0 14 22 Calculations approved bvACCA to meet all requirements of Manual J 8th Ed. -P}a- wrigt+tsofC� 2020May-1408:11:02 A�k- '^ Right -Suite® Uniwmal20i919.0.08 RSL108101 Page 2 E:1DocumtelakMghlsoftWAC1CICIORESIDENCE.mp Calc=MJB Front Doorfaces: N wrightsoft° Right-J® Worksheet Job: Entire House Date: May 14, 2020 By: QUICK CALLS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772466A799 Fax 772-460-6798 Email: QUICKCALCSCAOL.COM 1 Room name PANTRY M BATH 2 3 Fposed wall Room height 0 It 10.0 It heal/cool 16.0 ft 10.0 ft heat/cool 4 5 Room dimensions Room ales 4.0 x. 7.0 ft 28.0 ft' 1.0 x 190.0 ft 190.0 ft' Ty Construction number U-value (Btuhlft; F) Or HTM (Btuh/ft� Area (ftI or perimeter (ft) Load (Btuh) Area (ft� or perimeter (ft) Load (Btuh) Heat Cool Goss NIP/S Heat Cad Gross N/P/S Heat Cod 6 13A-Sots 2 glazing, clr low-e 2 glazing, cir low-e 0.125 0.580 0.680 n n n 3.50 16.24 16.24 1.91 13.73 13.73 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 -0 0 0 0 0 0 0 0 11 2 glazing, cir low-e 2 glazing. clr low- 0.580 0.580 n n 16.24 16.24 13.73 13.73 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 lIIllSSSS�VVVVV I--G 13A-5ots 2 glazing, cir low-e 2 glazing, clr low-e 2 glazing, cir low-e 2 glazing, cir lows 13ASocs 2 glazing, cir low-e 2 glazing, cir low-e 0.125 0.580 0.580 0.580 0.580 0.125 0.580 0.580 a a a a a a a a 3.50 16.24 16.24 16,24 16.24 3.50 16.24 16.24 1.91 77 26.77 M 20.60 29.60 1.91 13.73 13.73 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 160 0 5 0 12 0 0 0 143 0 1 0 1 0 0 0 500 0 64 0 195 0 0 0 273 0 13 0 365 0 0 0 ll�------GGG 2 glazing, cir low-e 2 glazing, cir low-e 0.580 0.580 s a 16.24 16.24 13.73 13.73 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 N13A15ocs 2 glazing, cir Iowa 2 glazing, cir lowe 2 glazing, cir Io+ 2 glazing, cir lows 2 glazing, cir lows 0.580 0.580 0.125 0.580 0.580 0.560 a s w w w w 16.24 16.24 3.50 10.24 16.24 16.24 13.73 13.73 1.91 26.77 30.46 30.95 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 C F 16X19Uad 22A-tph 0.408 1.358 - 1.59 38.02 1.37 0.00 28 28 28 0 44 0 38 0 190 19D 190 16 301 608 260 0 6 c)AED excursion -7 42 FmHope loss/gain 44 31 1689 985 12 a) InriMmtim b) Room ventilation 0 0 0 0 274 0 79 0 13 Internal gains: Occupants 0 230 0 0 0 0 Appliances/other 150 0 Subtotal Ones 6 to 13) 1 44 181 1963 10M Lass external load 0 0 0 0 14 15 Less transfer Redistribution Subtotal Dud beds 321% 61% 0 40 85 27 0 34 215 131 32% 1 61% 0 12 1974 834 D 10 1074 656 Total room load Air nequired (dm) 112 5 348 15 2609 105 1729 76 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. n -P�1- wrighes_of_!^ 2020May-1408:11:02 Right -Suite® Universal 2019 19.0.08 RSU08101 Page 3 �E:\Docurmets\WdghteoBWAC\CICIORESIDENCE,mp Calc-MJ8 Front Doorfaces: N wrlghtsofr Right-J® Worksheet Job: Entire House Date: May 14, 2020 QUICK CALCS, INC. By. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-46"799 Fac 7724666796 Emil: OUICKCALCSCAOL.COM 1 Room name M WIC M HALL 2 Exyosed wall O ft O ft 3 Room height 10.0 ft heallcool 10.0 1t hes1/cool 4 Rconn dimensions 17.0 x 7.0 ft 5.0 x 7.0 ft 5 Room area 119.0 ft' 35.0 ft' Ty Construction U-valos Or HTM , Area (ft� Load Ares (ftj Load number (BIUIyft;°F) (Btuh/ftjj or perimeter (ft) (Btuh) a perimeter (ft) (Stuh) Heat Cool Gross WP/S Heat Cod Gross WPIS Heat Cad 6 W 934,Uc9 0.125 n 3.50 0 0 0 0 0 0 0 0 2 glazing, clr loweto" 0.580 n ISIA 3.73 13.73 0 0 0 0 0 0 0 2 glazing, clr bw-e 0.580 n 18.24 13.73 0 0 0 0 a 0 0 0 0 2 glazing, cir low-e 0.5W ! n 16.24 13.73 0 0 0 0 0 0 0 0 11 (II(_----.GG 2 glazing, dr lowe 0.5W n 16.24 13.73 0 0 0 0 0 0 0 0 l{J 13A5ocs 0.125 a 3.50 1.91 0 0 0 0 0 0 0 0 f--f_' 2 glazing, clr low-e 0.580 a 16.24 26.77 0 0 0 0 0 0 0 0 2 glazing, cir love 0.580 a 16.24 20.77 0 0 0 0 0 0 0 0 2 glazing, clr laze 0.580 a 16.24 29.60 0 0 0 0 0 0 0 0 I��-GGC 2 glazing, cir low-e 0.580 a 16.24 29.60 0 0 0 0 0 0 0 0 '13k6ocs 0.125 a 3.60 1.91 0 0 0 0' 0 0 0 0 2 glazing; clr lave 0.580 a 16.24 13.73 0 0 0 0 0 0 0 0 2 glazing, Blr lowe 0,580 a 16.24 13.73 0 0 0 0 0 0 0 0 2 glazing; dr lov-e 0.580 a 16.24 13.73 0 0'' 0 0: 0 0 0 0 2 glazing, clr lave 0.580 s 16.24 13.73 0 0 0 0 0 0 0 0 2 glazing, cir lowe 0.580 s 16.24 13.73 0 0 0 0 0 0 0 0 2 glazing, cir lave 0.580 s 16.24 13.73 0 0 0 0 a 0 0 0 134-Sots 0.125 w 3.50 1.91 0 0 0 0 0 0 0 0 2 glazing, dr lave 0.560 w 16.24 M77 0 0 0 0 0 0 0 0 2 glazing, dr lave 0.560 w 16.24 30.46 0 0 0 0 0 0 0 0 2 glazing, cir lave 0.580 w 16.24 30.95 0 0 0 0 0 0 0 0 C 16X19-0ad 0.408 - 1.59 1.37. 119 119 169 163 35 .35 55 48 F 22A-tph 1.358 - 38.02 0.00 119 0 0 0 35 0 0 0 6 c)AED exxursion -25 -2 Envelope loss/gain 189 138 55 48 12 a) Infiltration 0 0 0 0 b) Roan ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliames/dher 600 0 Subtotal eines 6 to 13) 189 638 65 46 Less external load 0 0 0 0 Less transfer 0 0 0 0 Renfistrlbuticn 35 29 55 46 14 Subtotal 223 668 0 0 15 Duct loads 32°/u 1 61% 72 407 M. 61% 0 0 Total mom load 295 1073 0 0 Air required (rim) 12 47 0 0 Calculations approved bvACCA to meet all requirements of Manual J 8th Ed. c -P�F =ggft aoTe- 2020-May-1408:11:02 . CAN '" -" ^ "" Right-SuiteO Unlwmal 2019 19.0.08 RSU06101 Page 4 E:1DocunmetsLWdghtsoft WAC\CICIO RESIDENCE.mp Calc -MJ8 Front Door faces: N wrightsofr Right-M Worksheet Job: Entire House Date: May 14, 2020 QUICK CALCS, INC. By. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: T72466-6799 Fax 77246"796 Emil: QUICKCALCS@AOL.COM 1 Room name M TOILET MASTER BEDROOM 2 Eq)nsed wall 6.0 ft 39.0 It 3 Room height 10.0 It heat/oeol 10.0 ft heaV0001 4 5 Room dimensions Room area 6.0 x 5.0 ft 30.0 fN 16.0 x 17.0 ft 272.0 ft- Ty Constmction number U-value (Btuh/ftVF) Or HTM (Btuh/ft� Anna (i a perimeter (1t) Load (Btuh) Ares (ftTj a pen meter (1t) Load (Btuh) Heat Cool Gross WP/S Heat Cod Gross WP/S Heat Cod 8 13A-5= 0.125 n 3.50 1.91 0 0 0 0 0 0 0 0 2 glazing, clr lave 0.580 n 16.24 13.73 0 0 0 0 0 0 0 0 2 glazing, cir laue- 0.580 n 16.24 13.73 0 0 0 0 0 0 0 0 2 glazing, cir lave 0.580 a 16.24 13.73 0 0 0 0 0 0 0 0 11 2 glazing, cir lowe 0.580 in 16.24 13.73 0 0 0 0 0 0 0 0 13ASacs 0.125 a 3.50 1.77 80 51 170 BB 165 151 564 239 G _ 2 glazing, cir low-e 0.580 a 16.24 26.77 0 0 0 0 5 1 84 130 2 glazing, cir lows 0.580 a 16.24 26.77 0 0 0 0 0 0 0 0 2 glazing, cir lowe 0.580 a 16.24 29.60 9 1 146 266 0 0 0 0 2 glazing, cir lave 0.5W a 16.24 29.60 0 0 0 0 0 0 0 0 13ASocs 0.125 s 3.60 1.91 0 0 0 0 170 125 438 239 2 glazing, Ur bwe 0.580 s 16.24 13.73 0 0 0 0 0 0 0 0 2 glazing, cir bw-e 0.580 s 16,24 13.73 0 0 0 0 0 0 0 0 2 glazing, cir kw-e 0.580 s 16.24 13.73 0 0 0 01 0 0 0 0 2 glazing, err lore 0.680 a 16.24 13.73 0 0 0 0. 0 0 0 0 2 glazing, cir lowe 0.580 6 16.24 13.73 0 0 0 0 45 45 731 618 2 glazing, cir lave 0.580 s 16.24 13.73 0 0 0 0 0 0 0 0 13450m 0.125 w 3.60 1.91 0 0 0 0 60 60 210 115 2 glazing, cir lave 0.580 w 16.24 26.77 0 0 0 0 0 0 0 0 2 glazing, cir lave 0.680 w 16,24 30.46 0 0 0 0 0 0 0 0 2 glazing, cir lowe 0.5m w 16.24 30.95 0 0 0 0 0 0 0 0 C 1SX199ad 0.408 - 1.59 1.37 30 30 48 41 Z72 272 431 372 F 22A-tph 1.358 - 38.02 0.00 30 6 228 0 272 39 1483 0 6 c)AEDemumlon -17 -113 Envelope loss/gain S00 380 3919 1666 12 a) Mitiatlon 103 29 668 192 b) Roan ventilation 0 0 0 0 13 Ntemal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 1000 Subtotal pines 6 to 13) 703 418 4587 2558 Less external Intl 0 0 0 0 Less transfer 0 0 0 0 RedisMWltim 0 0 16 13 14 Subtotal 703 418 4W3 M71 15 Dud loads 32°� 81°/ 226 255k 61% 1479 1753 ro Total room load 929 673 6082 4624 -Tow(dm) 38 30 248 2m Calculations approved byACCA to meet all requirements of Manual J 8th Ed. ,� Ad- wrr9oft•' 2020-May-1408:11:02 RlghtSuiteO Unhersal 201919.0.08 RSU08101 Page 5 E:vDocurmets%Wdghtsoft HVAC%CICIORESIDENCE.mp Calc-M.18 Front Doorfaces: N L rn���� � pAAA RA 3 � C''aa 0f00_(O_!O_T f0_!O_IO fG_ t00f�m mR7p Cn B -aa nnaonn aaa 2 M HIM 11 �A Al uo w Ila y+O0000000OOOo00oo00000o oaoin000000uooQi'o in 8928bgg Yr� 0 �� � FFFFwmwwwmwtpmipmm»»> m+,'m,'m�'m]gw,'a'm,m',�'wf ,'m appu mwmmu+,m'NmN ,'m t'mtJJu Nro AA a O.NP A AA Ad O A� A� O A a A a 0 x � c�' 2 Q� a o ���oog000'm oo�'o00000000o w �'� + � o � v o tn0 N O O N O O O m O OL O O OO O OO O O O � m Y GG y 0 Q fJ (p mAAm mm ��11 (Oi��00 ?.SO OfJ 0 0 0�000ro000�00tX ....... 000 Q� O %�oOOOOOOOOOOOOOOOOO OlO b" �'� + o 0 � _mu000Qa'0000000000000000� N 3 o mA x om 2 sm A �� a�. aoo �m yy± oU' � 44 55�� Ai�ooa'0000000000000007iio� � �� o' -cs n sOzc o N o m ES N� O O N O O O W OT 00 Ot'!�O O O o O o O O O 00 O O O a O o 01 La 3 C + wrightsofC Right-M Worksheet Job: Entire House Date: May 74, 2020 QUICK CALCS, INC. By. 317 ST LUCIE LANE, FORT PIERCE, FL 34940 Phone: 77246"799 Fax 772466-6796 Email: QUICKCALCS@AOL.COM 1 Room name GREAT ROOM FOYER 2 EVosed wail 20.0 ft 10.0 ft 3 Room height 14.0 ft heat/cool 10.0 It healfcool 4 Roan dimmsims 22.0 x 20.0 It 6.0 x 10.0 ft 5 Roan area 440.0 fN 60.0 ft2 Ty Construction U-value Or HTM Area (ft2) Load Area (115 Load number (BtulvWF) (Btuh/ft5 a perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Tcoot Gross N/P/S Heat Cod Gross N/P/S Heat Cool 6 LN 13ASocs 0,680 n 0 0 0 0 100 80 210 110 2 glazing, or Ipwe 0.580 n 6.24 16.24 13.73 3.73 0 0 0 0 0 0 0 0 2 glazing, or love 0.580 n 16.24 13.73 0 0 0 0 0 0 0 0 2 glazing, clr Iowa 0.580 n 16.24 13.73 0 0 0 0 16 0 260 220 11 I(IL��-GG 2 glazing, clr Iowa 0,580 In 16.24 13.73 0 0 0 0 24 0 390 330 Vpl 0.580 a 3.24 1.77 0 0 0 0 0 0 0 0 2 glazing, low-e 2 glazing, 0.580 a 16.24 26.77 0 0 0 0 0 0 0 0 or 29lazing, clt Iowa 0.580 a 18.24 28.77 0 0 0 0 0 0 0 0 2 glazing, or Iowa 0.560 a 16.24 29.60 0 0 0 0 0 0 0 0 2 glazing, cl_r Iowa 0.580 a 16.24 29.60 0 0 0 0 0 0 0 0 134-5ocs 0.125 s 3.60 1.91 280 165 578 316 0 0 0 0 2 glazing, clr low-e 0.580 s 16.24 13.73 4 4 65 55 0 0 0 0 2 gluing, clr Iowa 0.680 s 16.24 13.73 15 15 244 208 0 0 0 0 2 glazing, clr Iowa 0.580 s 16.24 13.73 0 0 0 0 0 0 0 0 2 glazing, clr Iowa 0,680 s 16.24 13.73 0 0 0 0 0 0 0 0 2 glazing, clr lave 0.580 s 16.24 13.73 0 0 0 0 0 0 0 0 2 glazing, dlr low-e 0.580 s- 16.24 13.73 96 96 1559 1318 0 0 0 0 IN 1345ocs 0.580 w 3.24 0 0 0 0 0 0 0 0 2 glazing, cir Iowa 0.580 w 16.24 8.91 30.46 0 0 0 0 0 0 0 0 2 glazing, clr lows 0.580 w 16.24 30.95 0 0 0 0 0 0 0 0 2 glazing, cif Iowa 0,560 w 16.24 30.95 0 0 0 0 0 0 0 0 C 16X19-tw Q408 - 1.59 1.37 • 440 440 698 602 60 60 95 82 F 22A-tph 1.358 - 38.02 0.00 440 20 760 0 60 10 380 0 6 c)AED exursion -161 -34 Envelope loss/gain 3903 2335 1335 712 12 a) Infiltration 480 138 171 49 b) Room ventilation 0 0 1 0 0 13 hlennai gains: Occupants @ 230 0 0 0 0 Appliances/other 16M 100 Subtotal Qhes; 6 to 13) 4383 4073 1508 861 Less a Bernal load 0 0 0 0 Leas transfer 0 0 0 0 Redistributim 137 63 4 3 14 Subtotal 4519 4137 1510 865 15 Dud loads 3216 61% 1452 2526 32% 61% 485 528 Trial rmm load 5972 6662 1 1998 1392 Air required (dm) 241 292 81 61 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. c-Fw wrlghisoT!` 2020-May-1408:11:02 �A "" ""l "' RlgCIO RESDEfteG NCs.rupal ale-I8 RSWont Page E:1DocurmetslWrightsoft FNAC\CICIO RESIDENCE.rup Celc=MJB Front Door faces: N wrightsoft° Right-M Worksheet Job: Entire House Date: May 14, 2020 By; QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-486-8799 Fax 77246"796 Email: QUICKCALCS@AOL.COM 1 Roan name WIC 2 BEDROOM 2 2 3 Elrposed wall Room height 0 It 10.0 It heat/cool 25.0 It 10.0 It heat/owl 4 6 Room dimensions Room area &0 x 6.0 ft 30.0 It. 14.0 x 120 ft 168.0 ft' Ty Construction number U-valus (Btuhlft;°F) Or HTM (Btuh/ft� Area (ft� a perimeter (ft) load (Btuh) Area (fly a perimeter (ft) Load (Btuh) Heat Cod Gross WP/S Heat Cod Gross WP/S Heat Cad 8 13ASocs 2 glazing, cir love @ glazing, cir lows 0. 0.580580 0.680 n n n 16.246,24 16.24 .91 133.73 13.73 0 0 0 0 0 0 0 0 0 0 0 0 120 36 84 0 0 294 0 585 161 0 494 11 2 glazing, cir low-e 2 glazing, cir lows 0.580 0.580 n n 16.24 16.24 13.73 13.73 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 134-5acs 2 glazing, cir lave 2 glazing, cir low-e 0.126 0.580 0.580 a a a 3.50 16.24 16.24 1.91 28.77 26.77 0 0 0 0 0 0 0 0 0 0 0 0 130 0 0 130 0 0 455 0 0 249 0 0 2 glazing, cir lave 2 glazing, cir lows 0.580 0.580 a a 16.24 16.24 29.60 29.60 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 13ASoos 2 glazing, cir lave 2 glazing, cir lows 0.125 0.680 0.580 a s a 3.50 16.24 16.24 1.91 13.73 13.73 0 0 0 0 0 0 0 0 0 -0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 2 glazing, cir lave 2 glazing, cir low-e 0.580 0.580 s s 16.24 16.24 13.73 13.73 0 0 0 0 0 0 0. 0 0 0 0 0 0 0 0 0 2 glazing, cir ow-e 2 glazing, cir low-e 0.580 0.580 0.125 a a w 16.24 16,24 3,50 13.73 13.73 1.91 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 -0 0 0 0 0 0 0 0 N13A-5ocs 2 glazing, cir low-e 2 glazing, cir low-e 2 glazing, cir lone 0.580 0.580 0.580 w w w 16.24 16.24 16.24 28.77 30.46 30.95 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 C 16X19-0ad 0.408 - 1.59 1.37 30 30 48 41 168 leg 266 230 F 2244ph 1.358 - 38.02 0.00 30 0 0 0 168 25 D51 0 6 c) AED excursion -13 -55 Envelope loss/gain 48 28 2651 1078 12 a) InliiR2tion 0 0 428 123 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 300 200 Subtotal (lines 6 to 13) 48 328 2979 1401 Less eldenaI load 0 0 0 0 Less transfer 0 0 0 0 14 15 Redistribution Subtotal Dud loads 32% 61% 21 68 22 17 30 211 32°/ 61% 21 2999 964 17 late 888 Total room load 90 556 3963 2284 Air required (den) 4 2a 160 100 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. _ -FW wrrghes_of_t- 2020-May-1408:11:02 RlghtSulteO Universal 201919.0.08 RSU08101 Page 8 �AE:\DocunmetslWdghtsofl WAC%CICIORESIDENCE.mp Calo-M.18 Front Doorlaces: N wrightsoft' Right-J® Worksheet Job: Entire House Date: May 14, 2020 QUICK CALCS, INC. By- 317 ST LUCIE LANE, FORT PIERCE, FL 34M Phone: 77240M799 Fax 772d885796 Email: QUICKCALCS@A.OL.COM 1 Room name BEDROOM 3 HALL 2 2 3 EKposed wall Room height 27.0 It 10.0 It heathod 0 It 10.0 ft heat/oo i 4 5 Room dimensions Room area 15.0 x 11.0 ft 165.0 It. 1.0 x 69.0 It 69.0 It. Ty Construction U-value Or HTM Area (ftj Load Area (ftl Load number (BtufJf MF) (Btuh/ftn or perimeter (It) (Btuh) a perimeter (ft) (Btuh) Heat Ccd Gross N/P/S Heat Cod Gross WP/S Heat Cool 6 13AS0os 2 glazing, cir love 2 glazing, cir lawe 0.125 0.580 0.580 n n n 3.50 16,24 16.24 1.91 13.73 13.73 - 110 20 0 90 0 0 315 325 0 172 276 0 0 0 0 0 0 0 0 0 0 0 0 0 11 2 glazing, cir h" 2 glazing, clr bw-e 0.580 0.580 n n %24 16.24 13.73 13.73 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 t(V 2 glazing, cir lave 2 glazing, 2 glazing, clr bwe 0.680 0.560 0.580 B a a 3.24 16.24 18.24 26.77 8.7 26.77 10 0 0 10 0 0 35 0 0 10 0 0 0 0 0 0 0 0 0 0 0 0 0 0 2 glazing, clr Il 2 glazing. clr Il 0.680 0.580 a a 16.24 16.24 29.60 29.60 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 13A5ocs 2 glazing, dr lowe 2 glazing, clr lowe 0.125 0.580 0.580 s s s 3.50 16.24 16.24 1.91 13.73 13.73 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 2 glazing, clr lave 2 glazing, clr lawe 0.580 0.580 s s 16.24 16.24 13.73 13.73 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 W 2 glazing, clr lave 2 glazing, clr lave 13A-500s 0.580: 0.580 0.125 s s w 16.24 16.24 3.50 13.73 13.73 1.91 0 0 150 0 0 145 0 0 607 0 0 2(7 0 0 0 0 0 0 0 0 0 0 0 0 I--G 2 glazing, cir low-e 2 glazing, cir lave 2 glazing, dr la" 0.5m 0.580 0.580 w w w 16.24 16.24 16.24 26.77 30.48 30.95 5 0 0 1 0 0 84 0 0 139 0 0 0 0 0 0 0 0 0 0 0 0 0 0 IL----GG C 16X19-0ad 0.408 - 1.69 1.37 165 _ 165 262 228 69 69 109 04 F 224-lph 1.358 - 38,02 0.00 165 27 1027 0 69 0 0 0 6 c)AED excursion -38 4 Envelope loss/gain 2554 1070 109 91 12 a) Infiltration 462 133 0 0 b) Roo n ventilation 0 0 0 0 13 Internal gains: Occupar is @ 230 0 0 0 0 Appliances/other 9W 0 Subtotal Qines 6 to 13) 3017 2102 109 91 Less e�demal load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 10 9 .109 -91 14 Subtotal 3027 2111 0 0 15 Duct loads 32°k 61% 973 1289 32% 61% 0 0 Trial roan load 4000 3400 0 0 Airrequired(cfm) 181 149 0 0 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. -Fk- wrighboT!- 2020-May-1408:11:02 A95-A ^ "'" Right -Suite® Universal 2019 19.0.08 RSU08101 Page 9 E:1Documnets\WdghtsaltWAC1CIC1ORESIDENCE.mp Calc=MJ8 Front Doorfaces: N ►# wrightsoft• Right-J® Worksheet Job: Entire House Date: May 14, 2020 QUICK CALCS, INC. By: 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772466-6799 Fats 772466-6796 Emil: OUICKCALCS@AOL.COM 1 ROom name WIC 3 LINEN 2 Fposed wall 5.0 ft 0 ft 3 ROOM height 10.0 ft healfcod 10.0 ft heatt000l 4 Roan dimensions 5.0 x BA ft 2.0 x 6.0 ft 5 Room area 40.0 fto 120 ft' Ty Core�dion U-value Or HTM Arm Load (Btuldf MF) (Btuh/M a perimeter((ft) (Btuh) or perimeter (ft) (Ruh) Heat CGd Gross WP/S Heat Cod Gross WPIS Heat Cool 8 13A Sacs 0.125 n 3.50 1.91 0 0 0 0 0 0 0 0 2 glazing; cir love 0.580 n 16.24 13.73 0 0 0 0 0 0 0 0 2 glazing; cir iow-e 0.580 n - 16.24 13.73 0 0 ,0 0 0 0 0 0 2 glazing, cir Iowa 0.660 n 16.24 13.73 0 0 0 0 0 0 0 0 11 2 glazing, cir lave , 0:580 n. 16.24 13.73 0 0 0 0 0 0 0 0 ll4q!! 134.50cs 0.125 a 3.50 1.91 0 0 0 0 0 0 0 0 F--G 2 glazing, cir Iowa 0.680 a 16,24 25.77 0 0 0 0 0 0 0 0 2 glazing, cir to a 0.580 a 16.24 28.77 0 0 0 0 0 0 0 0 IIL---GGG 2 glazing, cir Iowa 0.580 a 16,24 29.60 0 0 0 0 0 0 0 0 2 glazing, cir kwa 0.580 a 16.24 29.60 0 0 0 0 0 0 0 0 134Socs 0.125 s 3.50 1.91 0 0 0 0 0 0 0 0 2 glazing, cir Iowa 0.580 a 16.24 '13.73 0 0 0 0 0 0 0 0 2 glazing, cir Iowa 0.580 s 16.24 13.73 0 0 0 0 0 0 0 0 2 glazing, or Iowa 0.580 a 16.24 13.73 0 0 0 0 0 0 0 0 2 glazing, clr Iowa. 0,580 a 16.24 13.73 0 0 0 0 0 0 0 0 2 glazing, cir bwe 0.580 a 16.24 13.73 0 0 '0 0 0 0 0 0 2 glazing, clrlowa 0.580 s. _ 16.24 13.73 0 0 0 _ 0 0 0 0 0 l{J 13ASocs 0.125 w 3.50 1.91 50 50 175 90 0 0 0 0 2 glazing, cir Iowa 0.580 w 16.24 26.77 0 0 0 0 0 0 0 0 2 glazing, clr Iowa 0.580 w 16.24 30.48 0 0 0 0 0 0 0 0 III-_--1GG' 2 glazing, cir lave 0.580 w 18.24 30.95 0 0 0 0 0 0 0 0 C 16X19-0ad 0.4D8 - 1.59 1.37 40 40 63 55 12 12 19 18 F 22Adph,. 1.358 38.02 0.00 40 5 190 0 12 0 0 0 6 c)AED excursion -14 -1 Envelope loss/gain 429 136 19 16 12 a) Infiltration 86 25 0 0 b) Room ven ilaOGn 0 0 0 0 13 Internal gains: Occupants Q 230 0 0 0 0 Appliances/other 2DO 0 Subtotal (Ilnes 6 to 13) 614 361 191 16 Less e#emal load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 17 14 -19 -16 14 Subtotal 631 375 0 0 15 Ductloads 32% 61% 171 229 3294 61% 0 0 Trial room load 1 702 604 0 0 Air required (don) 28 26 0 0 Calculations aooroved byACCA to meet all requirements of Manual J 8th Ed. c wrl^9hesofe 2026May-1408:11:02 . t\ RlghtSuiteO Lhilwmal 201919.0.08 RSU08101 Page 10 ESDocuwets%Wdghtsoft WAG\CICIORESIDENCE.mp Calc-MJS Front DoorNces: N wrightsoft Right-J® Worksheet Job: Entire House Date: May 14, 2020 QUICK CALCS, INC. By- 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 7724e6-6799 Fax 772466-6796 Email: OUICKCALCS@AOL.COM 1 Room name SINKS TOILET 2 Eryosed wall 0 It 6.0 It 3 Roan height 10.0 It healf000l 10.0 ft heatfood 4 5 Room dimensions Room area 6.0 x 6.0 ft 36.0 ft° 6.0 x 6.0 ft 36.0 ft' Ty Construction number U-value (Btutyfti°F) Or HTM (Bt&ftl Area . (fly or perimeter (ft) Load (Btuh) Arm (ft5 a perimeter (ft) Load (Btuh) Heat Cool Gross WP/S Heat cool Gross WP/S Heat Cod 6 13445ocs 2 glazing, cir low-e 2 glazing, or Iowa 0.125 0.580 0.580 n n n 3.60 16.24 16.24 1.91 13.73 13.73 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 11 2 glazing, or lowe 2 glazing, cir lowe 0.580 0.580 n n 16.24 16.24 13.73 13.73 0 0 0 0 0 0 0 0 0 0 '0 0 0 0 0 0 G- 2 glazing, cir lowe 2 glazing, 2 glazing, cir love 0.680 0.580 0.580 a a a 6.24 16.24 18.74 1.91 28.77 28.77 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 2 glazing, cir Iowa 2 glazing, cir Iowa 0.580 0.680 a a 16.24 16.24 29.60 29.60 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 13A-5xs 2 glazing, clr Iowa 2 glazing, dr lowe 0.125 0.580 0.580 s s s 3.50 16.24 18.24 1.91 13.73 13.73 0 0 0 0 0 0 0 0 0- 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 2 glazing, clr Iowa 2 glazing, cir Iowa 0.560 0.580 s s 16.24 18.24 13.73 13.73 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 2 glazing, clr Iowa. 0.680 s 16.24 13.73 0 0 0- 0 0 0 0 0 W 2 glazing, clr Iowa 13A-50cs 0.580 0.125 a w 16.24 3.50 13.73 1.91 0 0 0 0 0 0 0 0 0 60 0 55 0 192 0 105 I--G IL----GG 2 glazing, or Iwra 2 glazing, cir Iowa 2 glazing, cir love 0.580 0.580 0.580 w w w 18.24 16.24 16.24 26.77 30.46 30.95 0 0 0 0 0 0 0 0 0 0 0 0 5 0 0 1 0 0 84 0 0 139 0 0 C 16X19-0ad 0.408 - 1.59 1.37 36 36 57 49 36 38 57 49 F 22A-tph 1.358 - 38.02 0.00 36 0 0 0 36 8 22B 0 6 c)AED exaursiol -13 73 Envelope Iwstgain 57 36 Est 366 12 a) Infiltration 0 0 103 29 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants 0 230 0 0 0 0 Appdiances(dler 300 0 Subtotal Qines 6 to 13) 57 336 664 395 Less ademal load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 31 26 0 0 14 Subtotal 88 362 664 395 15 Duct loads 32°k 61°/ 28 221 32°/ 61% 213 2A1 Toted roan load 117 583 878 637 Ain required (cfm) 5 26 35 28 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. -ow wrl9tiboH^ 2020-May-1408:11:02 A&kRight-Suite® Universal 201919.0.08 RSLI08101 Page 11 ESDocametslWdgh!soft WAC1CICIORESIDENCE.mp Celc=MJ8 Front Doorfaces: N wrightsoft Right-J® Worksheet Entire House QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-486-6799 Fax 772466E796 Emil: OUICKCALCS@AOL.COM Job: Date: May 14, 2020 By: 1 Room name BATH 3 WIC 4 2 EVosed wall 0 It 6.0 It 3 Roan height 10.0 It heallcod 10.0 ft heal/cool 4 Room dimensions 6.0 x 13.0 fl 6.0 x 5.0 ft 5 Room area 78.0 ft- 30.0 ft2 Ty Con�dion U-value Or HTM Arm (ft2) Load Arm (ft2) Load I (Bluh/WF) (Btuh/ft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Hml Cod Gross N!P/S Heat Cool Gross WP/S Heat Cod 8-G 13ASocs 0.580 n 3.50 1.73 0 0 0 0 0 0 0 0 2 glazing, cir low-e 0.580 n 16.24 13.73 0 0 0 0 0 0 0 0 2 glazing, cir lows 0.580 n 16.24 13.73 0 0 0 0 0 0 0 0 2 glazing, cir low-e 0.580 n 16.24 13.73 0 0 0 0 0 0 0 0 11 2 glazing, dr lowe 0.580 n 16.24 13.73 0 0 0 0 0 0 0 0 134-Sots 0.125 a 3.50 1.91 0 0 0 0 0 0 0 0 2 glazing, dr lowe 0.580 w 16.24 25.77 0 0 0 0 0 0 0 0 2 glazing, dr lowe 0.580 a 16.24 23.77 0 0 0 0 0 0 0 0 2 glazing, dr luxe 0.580 a 16.24 29.60 0 0 0 0 0 0 0 0 2 glazing, cir lame 0.580 a 16.24 29.60 0 0 0 0 0 0 0 0 134-5ocs Q125 s 3.60 1.91 0 0 0 0 0 0 0 0 2 glazing, dr lame 0.580 s 18.24 13,73 0 0 0 0 0 0 0 0 2 glazing, cir lave 0.580 s 16.24 13.73 0 0 0 0 0 0 0 0 2 glazing, cir love 0.580 s 16.24 13.73 0 0 0 0 0 0 0 0 2 glazing, cIr lave 0.580 s 16.24 13.73 0 0 0 0 0 0 0 0 '2 glazing, dr lame 0.580 s 16.24 13.73 0 0 0 0 0 0 0 0 2 glazing, cir lowe 0.580 s 16,24 13.73 0 0 0 0 0 0 0 0 13ASoos 0.125 w 3.50 1.91 0 0 0 0 60 60 210 115 2 glazing, cir lows 0.580 w 16.24 25.77 0 0 0 0 0 0 0 0 2 glazing, cir lows 0.580 w 16.24 30.46 0 0 0 0 0 0 0 0 2 glazing, cir Iwre 0,580 w 16.24 30.95 0 0 0 0 0 0 0 0 C 1aX19m - 0.408 - 1.59 1.37 78 78 124 107 30 30 48 41 F 22A-tph 1.358 - 38.02 0.00 78 0 0 0 30 8 228 0 6 c)AED emmion -25 -13 Envelope loss/gain 124 92 486 143 12 a) Infiltration 0 0 103 29 b) Room \entllation 0 0 1 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliancmrdher 650 150 Subtotal (limes 6 to 13) 124 632 588 323 Less w demal load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 57 27 0 0 14 Subtotal 181 659 588 323 15 Duct loads 32% 61% 58 402 32% 61% 189 197 Tdal room load I 1 239 1061 778 519 Airrequired(dm) 10 47 31 23 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. -owwrighisof!-' 2020-May-1408:11:02 I&K "d is Right-Suite®DENC alp alc -M RS1108101 Page 12 E:\Docwmets\Wd9hisoft HVAC\CICIO RESIDENCE.mp Celc=MJw Front Door faces: N wrightsoft' Right-JO Worksheet Job: Entire House Date: May 14, 2020 QUICK CALCS, INC. By. 317 STLUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-486-6799 Fax 772-069-6798 Email: QUICKCALCWOLCOM 1 Room name HALL BEDROOM 4 2 E)yosed wall 3.0 ft 13.0 ft 3 ROom height 10.0 ft heaUocol 10.0 ft heat/cool 4 5 Room dimensions Roan area 13.0 x 4.0 ft 520 ft' 13.0 x 14.0 ft 182.0 W Ty Construction U-Wlue Or HiM Area Load �et number (BtulUfti°F) (Btuh/ft� a perimeter r (ft) (Btuh) wperim(eter (ft) (Bluh) Heat Cod Gross WP/S Heat Cool Gross WP/S Heat Cod 6 134-5ocs 0.125 n 3.50 1.91 0 0 0 0 0 0 0 0 2 glazing, clr lowe 2 glazing, clr lowe 0.580 0.580 n n 16.24 16,24 13.73 13.73 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 11 2 glazing, clr lowe 2 glazing, clr Iowa U80 0.560 n n 16.24 16.24 13.73 13.73 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 2 glazing, clr lave 2 glazing, 0.580 0.580 a a 350 16.24 6.77 26.77 30 0 30 0 100 0 57 0 0 0 0 0 0 0 0 0 2 glazing, clr Iowa 0.580 a 16.24 28.77 0 0 0 0 0 0 0 0 2 glazing, clr lava 0.580 a 18.24 29.60 0 0 0 0 0 0 0 0 2 glazing, dr lava 0.580 a 16.24 29.60 0 0 0 0 0 0 0 0 13A-50ca 0.125 a 3.50 1.91 0 0 0 0 0 0 0 0 2 glazing, cir lawe 0.580 s 16.24 13.73 0 0 0 0 0 0 0 0 2 glazing, clr lave 0.580 a 16.24 13.73 .0 0 0 0 0 0 0 0 2 glazing. cir Iowa 0.580 s 16.24 13.73 0 0 0 0 0 0 0 0 2 glazing, clr Iowa 0.580 s 18.24 13.73 0 0 0 0 0 0 0 0 2 glazing, cir Iowa 0.580 s 16.24 13.73 0 0 0 0 0 0 0 0 2 glazing, dr Iowa 0.580 s 1&24 13.73 0 0 0 0 0 0 0 0 0.125 w 3,50 1.91 0 0 0 0 130 100 350 191 N13X50:s 2 glazing, dr low-e. 0.580 w 16.24 25.77 0 0 0 0 0 0 0 0 2 glazing, cir Iowa 0.580 w 16.24 30.46 0 0 0 0 30 2 487 914 2 glazing, clr Iowa 0.580 w 16.24 30.95 0 0 0 0 0 0 0 0 C 16X19eed 0.408 - 1.59 1.37 52 52 82 71 182 182 289 249 F 22A-tph 1.358 - 38.D2 0.00 52 3 114 0 182 13 494 0 6 c)AEQ excurelon 4 354 Envelope loss/on 302 123 1620 1709 12 a) Infiltration 51 15 223 64 b) Roan %entilation 0 0 0 0 13 Internal gains: Occupants (aj 230 0 0 0 0 Appliances/other 0 3D0 Subtotal (lines 6 to 13) 353 138 1843 2073 Less odemal load 0 0 0 0 Less transfer 0 0 0 0 Redstdbution -353 -138 148 58 14 Subtotal 0 0 1991 2130 15 Duct loads 3W% 61% 0 0 32% 81% 640 1301 Trial roan load 0 0 2630 3431 Air required (cfnl) 0 0 108 161 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. wr19hlsoTt- 2020-May-14 D8:11:02 A ck Right -Suite® universal 201919.0.08 RSU08101 Page 13 ESDocurmets%Wdghtso8WAC1CICIORESIDENCE.mp Cale-M.18 Front Deorfaces: N 2 000000000000000000000mo m o0 0o m oomoo 00 a �� �� 000000000000000000000mo w Oo w oowoo 00 e = U 0 X �O 000000000000000000000'o a o � y a m W � 'Qi Z � r 0 0 o N 000000000000000000000N� o A, m � w� x UIR 2 cN 00000�0000.(�OOOQN OOtnO�O N� O v 6 0 nj GC O O C ® O O O 00 �100 O O O O O ON 00 O O 'O mW O W6.j Ali �1((p�p1WW�mgmgq Wnr n6666w (g(p pg og( 6 '�����NNNN^����em-�'{V WCI^OO ia yyppOOVOppCpCCOpyGpSNNNN SNN N ARA N An ans Ana 99 O eirorommoi----of------vf -m�� ,� Q cccccmmmmmmmmwmwm;;;;� rL WOm p p W Op] GG pp pp pp pp OO O pp O0 O 00 0 mm '000�'WWWW�WmWW00N000 O1� 1(lWW mWWNW �� 1lffllW WW1 0� WW OO o0000000c000000000000'0� $m �ffi OX aUUU TJVVURIB yB �7 SZS Zi Ti UUTi m----�' c y 'g ;�+ c ywrnrnmmrnww wwwmrnawww ya 'N c IRO. NNNN NNNN NNNNNN�-NNN N w 220SS L� � �i e�(`� 5 � WWI F u IJ m a 3 O-; F a 7 T w 14 wrightsoft° Duct System Summary Entire House QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34948 Phone: 772-488A799 Fa¢ 77246"796 Email: OUICKCALCS@AOL.COM For. CHRISTOPHER AND SHANA CICIO, GEM BUILDERS 1807 HAZELWOOD DRIVE, FORT PIERCE, FL External static pressure Pressurelosses Available static pressure Supply / return available pressure Lowest friction rate Actual airflow Total effective length (TEL) Heating 1.00 in H2O 0 in H2O 1.00 in H2O 0.500 / 0.500 in H2O 1.000 in/100ft 1933 cfm 207 Job: Date: May 14, 2020 By: cooling 1.00 in H2O 0 in H2O 1.00 in H2O 0.500 / 0.500 in H2O 1.000 in/100ft 1933 cfm Supply Branch Detail Table Name Design (Btuh) Htg (cfm) Clg (cfm) Design FIR Diam (in) H x W (In) Duct Matl Actual Ln (ft) Ftg.Egv Ln (ft) Trunk BATH 3 c 1061 10 47 1.000 6.0 Ox 0 VIFx 45.6 155.0 st6 BEDROOM 2 h 3963 160 100 1.000 7.0 Ox0 VIFx 19.9 115.0 st3 BEDROOM 3 h 4000 161 149 1.000 8.0 Ox0 VIFx 33.4 135.0 s1:5 BEDROOM 4 C 3431 106 151 1.000 8.0 OxO VIFx 43.3 155.0 st6 FOYER h 1996 81 61 1.000 6.0 OxO VIFx 18.5 115.0 st3 GAME ROOM h 6172 249 150 1.000 8.0 OxO VIFx 52.1 155.0 st6 GREATROOM c 3331 121 146 1.000 8.0 OxO VIFx 25.6 115.0 st2 GREATROOM-A c 3331 121 146 1.000 8.0 OxO VIFx 23.7 115.0 st2 KITCHENDINING c 3503 103 154 1.000 8.0 OxO VIFx 22.9 115.0 st2 KITCHENDINING-A C 3503 103 154 1.000 8.0 Ox0 VIFx 24.6 115.0 st2 M BATH h 2609 105 76 1.000 6.0 OxO VIFx 43.8 135.0 st4 M TOILET h 929 38 30 1.000 5.0 Ox0 VIFx 41.9 135.0 st4 Mwlc c 1073 12 47 1.000 6.0 Ox0 VIFx 44.7 135.0 st4 MASTER BEDROOM h 3041 123 101 1.000 7.0 Ox0 VIFx 45.1 135.0 st4 MASTER BEDROOM -A h 3041 123 101 1.000 7.0 Ox0 VIFx 44.5 135.0 st4 OFFICE h 3201 129 102 1.000 7.0 Ox0 VIFx 21.7 115.0 st1 PANTRY a 346 5 15 1.000 4.0 OxO VIFx 18.6 115.0 st1 POWDER RM c 503 14 22 1.000 5.0 Ox0 VIFx 22.3 115.0 st1 SINKS c 583 5 26 1.000 5.0 Ox 0 VIFx 29.2 135.0 st5 TOILET' h 878 35 28 1.000 5.0 Ox 0 VIFx 30.3 135.0 st5 UTILITY RM h 1647 67 54 1.000 6.0 Ox0 VIFx 23.6 115.0 st1 WIC 2 c 556 4 24 1.000 5.0 Ox 0 VIFx 17.0 115.0 st3 WIC h 702 28 26 1.000 5.0 OxO VIFx 31.7 135.0 st5 WIC h 778 31 23 1.000 5.0 0x0 VIFx 48.3 155.0 st6 .� -Fp- wrightsoft' 202Way-1408:11A2 t Right -Suite® Unitersal201g 19.0.08 RSW8101 Page 1 ^"`^`E:\Docurnets\Wrighlsoft WAC\CICIO REStDENCE.mp Cale =MJ8 Front Door faces: N Name Trunk Type Htg (cfm) Clg (cfm) Design FIR Veloc (fpm) Diam (in) H x W ([n) Duct Material Trunk st6 Peak AVF 396 370 1.000 727 10.0 0 x 0 VinlFlx st5 sty Peak AVF 626 599 1.000 798 12.0 0 x 0 VinlFlx st3 st3 Peak AVF 871 785 1.000 814 14.0 0 x 0 VinlFlx st4 Peak AVF 400 356 1.000 734 10.0 0 x 0 VinlFlx st1 st1 Peak AVF 615 548 1.000 783 12.0 0 x 0 VinlFlx st2 Peak AVF 447 600 1 1.000 764 12.0 0 x 0 VinlFlx Name Grille Size (in) Htg (cfm) Cig (cfm) TEL (ft) Design FIR Veloc (fpm) Diam (in) H x W (in) Stud/Joist Opening (in) Duct Mat[ Trunk rb1 Ox0 1933 1933 0 0 0 0 Ox 0 VIFx -F�- wrightsof[" • • -�+•n Right-Sulte® Universal 2019 19.0.08 RSU08101 SAE:\Oocurmets\Wrlghtsoft WAC\CICIORESIDENCE.rup Celc-MJ8 Front Doorraces: 2020-May-14 08:11:12 Page 2