Loading...
HomeMy WebLinkAboutDiagram, picture, specsC__:&CL'S!S 1 5618W Biltmore St fort 5t. Lucie, FL 34983 Tel (772) 607-9494 Fax (772) 785-7058 E -Mail: AApexelectric@yahoo.com www.aapexelectric.com License: ER13014699 Proud members of.• ¢ulld.nq n Bct r Tom ro:•:. —.00-0 - . . . . . . . . . . . . M. .. Afhjjrj _ -HOME 6/19/2020 1-h8XX9wyBfFumYdwjZ-1-1 MoNjHAEpedfW9TaNtJWJwxKhcVGrZ3P_OR6GH6Z2bZfMEOHbUijjMN26eDKxFdwDllbtgS3E1 vCDlxgwvU-1 https://gml.ggpht.com/1-h8XX9wyBfFumYdwjZ-I-1 MoNjHAEpedfW9TaNtJWJwxKhcVGrZ3P_OR6GH6Z2bZfMEOHbUiIIMN26eDKxFdwDllbtgS3E1vC... 1/1 Product Data Sheet Q0112M100RB Load Center, 100A, Main Type: Convertible - Factory installed main breaker 8OUARE D by Schneider Electric Technical Characteristics Spaces 12 Wire Size #6 to 2/0 AWG(AI/Cu) Wiring Configuration 3 -Wire Voltage Rating 1201240VAC Width 14.75 Inches Depth 4.52 Inches Height 18.92 Inches Approvals UL Listed Cover Type Surface Designed to meet residential, commercial and industrial requirements to protect electrical Application systems, equipment and people. Ampere Rating 100A Bus Material Tin Plated Copper Catalog Reference Number 110OCT9901 Enclosure Type Outdoor/Rainproof Box Number 3R Phase 1 -Phase Enclosure Rating NEMA 3R Grounding Bar Order separately Short Circuit Current Rating 22kA Main Type Convertible - Factory installed main breaker Maximum Single Pole Circuits 12 Maximum Tandem Circuit Breakers 0 Spaces 12 Wire Size #6 to 2/0 AWG(AI/Cu) Wiring Configuration 3 -Wire Voltage Rating 120/240VAC Width 14.75 Inches Depth 4.52 Inches Height 18.92 Inches Approvals UL Listed Cover Type Surface Designed to meet residential, commercial and industrial requirements to protect electrical Application systems, equipment and people. Ampere Rating 100A Bus Material Tin Plated Capper Catalog Reference Number 1100CT9901 Enclosure Type Outdoor/Rainproof C Schneider O 2009 Schneider Electric. All rights reserved. 'Electric Box Number Phase Enclosure Rating Grounding Bar Short Circuit Current Rating Main Type Maximum Single Pale Circuits Maximum Tandem Circuit Breakers 313 1 -Phase NEMA 3R Order separately 22kA Convertible - Factory installed main breaker 12 0 Notes: 22kA main circuit breaker UL Listed for use ahead of QO, QOT, QO-GFI, 00 -AFI, QO-EPD and QO-PL 10kA branch circuit breakers to permit their application on systems up to 22kA available fault current. Shipping and Ordering Category 00002 - Load Centers, Outdoor, 1 phase 12-42 CKT,NEMA3R Discount Schedule DESA Article Number 785901867876 Package Quantity 1 Weight 21.88 lbs. Availability Code Stock Item: This item is normally stocked in our distribution facility. Returnability Y As standards, specifications, and designs change from time to time, please ask for confirmation of the information given in this document. Generated: 06/19/2009 01:25 4i; © 2009 Schneider Electric. All rights reserved. Schneider OElectric