Loading...
HomeMy WebLinkAboutCertificate for Design Load CompliancePlanning & Development Services Department ® Building & Code Regulations Division 2300 Virginia Avenue, Fort Pierce, FL 34982 — (772) 462-1553 Certification for Design Load Compliance Project Name: eC5.4(ncc Project Address: Lek A3 Vcn)krc )jnrL*r i c,-. L-a. GLo F(-- Permit#: Occupancy Type: Construction Type: INSTRUCTIONS FOR USE: • This certification must be completed, signed, and sealed by the design professional of record. • Submit (2) copies for residential, (3) copies far commercial with all permit applications involving the following: o New Residences (single or multi -family) o Residential Addition o Any accessory structure requiring a building permit o Any non-residential structure. * Note: Form not required for interior renovations provided that no exterior structural elements are affected and certain minor building permits at the discretion of the local building official. Contact the # above for questions. DESIGN PARAMETERS AND ASSUMPTIONS USED: (complete all that apply) 1. DESIGN CODE: Florida Zo 1'7 Code Fifth Edition with 20_2o Supplements using ASCE 7-10 2. Structure Designed as (check one): x Enclosed _Partially Enclosed _Open 3. Risk Category: _I X11 _III _ IV Exposure Category: _B _C A D 4. Design Wind Velocity j 7'e mph ASD _2�­LRFD End Zone Width: N• y ft 5. Mean Roof Height 17' Y" ft Roof Pitch: 5 :12 Parapet: —L!LA—ft 6. Components & Cladding Design Pressures Used: (PSF, based on 10sgft @ 1S'MRH, clearly label on all plan openings): Zone1: H3.a Zone 2: 7Y•9 Zone3: 7H•9 Zone4: 'f7.7 Zone5: 5G.3 Garage: 4f'7•N 7. Design Loads: Floor: N 1A PSF Roof/Dead: PSF Roof/Live: 3 o Balcony: N A PSF Dock: N A PSF Deck: _PSF Stairs: 'to PSF Fence: NIA PSF Railings: N A PSF 8. Were Shear Walls Considered For Structure? X Yes _Not Applicable Explain Why Not: 9. Is A Continuous Load Path Provided? X Yes _Not Applicable Explain Why Not: 10. Design Soil Bearing Pressure: z SDo PSF Soil Test Reports Submitted? Yes DESIGN PROFESSIONAL CERTIFICATION STATEMENT: I certify that, to the best of my knowledge and belief, the attached plans & specifications have been designed to comply with the applicable structural portions of the building codes currently adopted and enforced by St. Lucie County. I also certify that structural elements depicted on these plans provide adequate resistance to the design forces snecified: S;k- Si 9 l• cG ,VE * Qo56 -426Zlc, Print Name Cert # & Co. Cert Auth. �(NF�rYtiM ��Sinrr rl'n3 /?Siuc;e, f F, tiH.ist�kcL,rnr}(.,2d. Sk•IoS /me c � 33YL3 Company Name & Address :ILE cur Revised 07/25/2014 /