Loading...
HomeMy WebLinkAboutEnergy CodeFORM R405-2017 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: WIENCKE RESIDENCE Builder Name: Street: LOT A3 VENTURE HARBOR Permit Office: ST LUCIE COUNTY City, Slate, Zip: JENSEN BEACH, FL, Permit Number: Owner: Jurisdiction: ST LUCIE COUNTY Design Location: FL, Fort Pierce County: St. Lucie (Florida Climate Zone 2 ) 1. New construction or existing New (From Plans) 9. Wall Types (1835.7 sqft.) Insulation Area 2. Single family or multiple family Single-family a. Concrete Block- Inl Insul, Exterior R=5.0 1510.00 ft= b. Frame- Wood, Adjacent R=11.0 325.67 ft' 3. Number of units, if multiple family 1 c. NIA R= fN 4. Number of Bedrooms 2 d. N/A R= fF 5. Is this a worst case? No 10. Ceiling Types (1699.0 sqft.) Insulation Area a. Roof Deck (Unvented) R=19.0 1699.00 ft' 6. Conditioned Floor area above grade (ft� 1699 b. N/A R= ft' Conditioned floor area below grade (ft� 0 c. NIA R= ft' 11. Ducts R ft' 7. Windows(305.0 sqft.) Description Area a. Sup: Attic, Rat: Attic, AH: Attic 6 140 a. U-Factor: SgI, U=0.40 305.00 ft' SHGC: SHGC=0.20 b. U-Factor: N/A ft2 12. Cooling systems kBtuRv Efficiency .. SHGC: a. Central Unit 30.0 SEER:16.00 c. U-Factor: N/A ft' SHGC: 13. Heating systems kBtu/hr Efficiency d. U-Factor: N/A ft' a. Electric Strip Heat 27.0 COP:1.00 SHGC: Area Weighted Average Overhang Depth: 5.226 ft. Area Weighted Average SHGC: 0.200 14. Hot water systems a. Electric Tankiess Cap: 1 gallons 8. Floor Types (1699.0 sgft.) Insulation Area EF: 0.990 a. Slab -On -Grade Edge Insulation R=n.O 1699.00 ft' b. Conservation features b. N/A R= ft' None c. NIA R= ft' 15. Credits None Glass/Floor Area: 0.180 Total Proposed Modified Loads: 59.52 PASS Total Baseline Loads: 60.53 I hereby certify that the plans and specifications covered by Review of the plans and ST- this calculation are in compliance with the Florida Energy specifications covered by this 0�'SiJE y g O� Code. calculation indicates compliance „ z with the Florida Energy Code. N nm'•-: -;=:i . ,., „ O PREPARED BY: Qka&ABefore construction is completed " o DATE: 5-15-2020 this building will be inspected for compliance with Section 553.908 I hereby certify that this b#ing, as de 'gned, is in compliance Florida Statutes. ASS with the Florida Energy Ade. C ODyyg SR OWNER/AGENT- BUILDING OFFICIAL: DATE: -/ DATE: - Compliance requires certification by the air handler unit manufacturer that the air f lile�l r®�ualjfies as certified factory -sealed in accordance with R403.3.2.1. 6 -Compliance requires an Air Barrier and Insulation Inspection Checklist In accorda a with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2). 5/14/2020 11:03 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 6 FORM R405-2017 INPUT 5UMMAKY UHLUKLIb I KtPUKI PROJECT Title: WIENCKE RESIDENCE Bedrooms: 2 Address Type: Street Address Building Type: User Conditioned Area: 1699 Lot# Owner Name: Total Stories: 1 BlocklSubdivision: # of Units: 1 Worst Case: No PlatBook: Builder Name: Rotate Angle: 0 Street: LOT A3 VENTURE HA Permit Office: ST LUCIE COUNTY Cross Ventilation: No County: St. Lucie Jurisdiction: ST LUCIE COUNTY Whole House Fan: No City, State, Zip: JENSEN BEACH, Family Type: Single-family FL, New/Existing: New (From Plans) - Comment: CLIMATE Design Temp Int Design Temp Heating Design DailyTemp Design Location TMY Site 97.5 % 2.5 % Winter Summer Degree Days Moisture Range FL, Fort Pierce FL VERO_BEACH MUNI 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume 1 Entire House 1699 16560.7 SPACES Number Name Area Volume Kitchen Occupants Bedrooms Infil ID Finished Cooled Heated 1 MASTER BEDR60 264 2455.2 No 0 1 1 Yes Yes Yes 2 M WIC 54 502.2 No 0 1 Yes Yes Yes 3 M TOILET 30 279 No 0 1 Yes Yes Yes 4 M BATH 124 1153.2 No 0 1 Yes Yes Yes 5 LAUNDRY 58 539.4 No 0 1 No Yes Yes 6 FOYER 152 2173.6 No 0 1 Yes Yes Yes 7 KITCHEN 176 1636.8 Yes 0 1 No Yes Yes 8 DINING ROOM 225 2092.5 No 0 1 Yes Yes Yes 9 LIVING ROOM 211 1962.3 No 0 1 Yes Yes Yes 10 BEDROOM 2 165 1534.5 No 0 1 1 Yes Yes Yes 11 CLST 2 22 204.6 No 0 1 Yes Yes Yes 12 BATH 2 66 613.8 No 0 1 Yes Yes Yes 13 DEN 120 1116 No 0 1 Yes Yes Yes 14 HALL 32 J 297.6 No 0 1 No Yes Yes FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Slab -On -Grade Edge Insulation MASTER BEDRO 31 It 0 264 ft2 1 0 0 2 Slab -On -Grade Edge Insulation M WIC Eft 0 54 112 -- 1 0 0 3Slab-On-Grade Edge Insulation M TOILET 3 ft 0 30 ft2 -- 1 0 0 4 Slab -On -Grade Edge Insulation M BATH loft 0 124 ft2 -- 1 0 0 5/14/2020 11:03 AM EnergyGaugeO USA 6.0.D2 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 2 of 6 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 5 Slab -On -Grade Edge Insulation LAUNDRY t ft 0 58 ft2 — 1 0 0 6 Slab -On -Grade Edge Insulation FOYER 8 ft 0 152 ft' ___ 1 0 0 7 Slab -On -Grade Edge Insulation KITCHEN 1ft 0 176 ft2 -- 1 0 0 8 Slab -On -Grade Edge Insulation DINING ROOM 23 It 0 225 ft2 __ 1 0 0 9 Slab -On -Grade Edge Insulation LIVING ROOM 28 ft 0 211 ft2 -- 1 0 0 1091ab-On-Grade Edge Insulation BEDROOM 2 11 ft 0 165 ft2 --_ 1 0 0 11SIab-On-Grade Edge Insulation CLST 2 2 ft 0 22 f' __ 1 0 0 12SIab-On-Grade Edge Insulation BATH 2 6 ft 0 66 112 — 1 0 0 13Slab-On-Grade Edge Insulation DEN 29A It 0 120 IF — 1 0 0 14SIab-On-Grade Edge Insulation HALL 1 ft 0 32 ft2 ___ 1 0 0 ROOF Roof Gable Roof Red Solar SA Emitt Emitt Deck Pilch V # Type Materials Area Area Color Ban Absor. Tested Tested Insul. (deg) 1 Hip Metal 1840 ft2 0 ft2 Light N 0.4 No 0.9 No 19 22.6 ATTIC / V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Unvented 0 1699 ft2 N N CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type _ 1 Under Attic(Unvented) MASTER BEDRO 0 Blown 264 it' 0.1 Wood _ 2 Under Attic(Unvented) MWIC 0 Blown 54 ft2 0.1 Wood 3 Under Attic(Unvented) MTOILET 0 Blown 30 ft2 0.1 Wood 4 Under Attic(Unvented) MBATH 0 Blown 124 ft2 0.1 Wood 5 Under Attic(Unvented) LAUNDRY 0 Blown 58 ft2 0.1 Wood 6 Under Attic(Unvented) FOYER 0 Blown 152 ft2 0.1 Wood 7 Under Attic(Unvented) KITCHEN 0 Blown 176ft2 0.1 Wood _ 8 Under Attic(Unvented) DINING ROOM 0 Blown 225 ft2 0.1 Wood 9 Under Attic (Unvented) LIVING ROOM 0 Blown 211112 0.1 Wood _ 10 Under Attic(Unvented) BEDROOM 0 Blown 165 ft2 0.1 Wood 11 Under Attic(Unvenled) CLST2 0 Blown 22 ft2 0.1 Wood 12 Under Attic (Unvented) BATH 2 0 Blown 66 ft2 0.1 Wood 13 Under Attic(Unvented) DEN 0 Blown 120 fR 0.1 Wood 14 Under Attic(Unvenled) HALL 0 Blown 32 ft2 0.1 Wood 5/14/2020 11:03 AM EnergyGaugeO USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 3 of 6 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT WALLS it nmf Adjacent Space Tn WAR Type Cavity Width Height Sheathing Framing Solar Below _ 1 N Exterior Concrete Block- Int InsuMASTER BE 5 15 0 9 4 140.0 f' 0 0 0.4 0 -2 E Exterior Concrete Block- Int InsuMASTER BE 5 16 0 9 4 149.3 ft- 0 0 0.4 0 3 N Exterior Concrete Block- Int Insul M WIC 5 6 0 9 4 56.0 ft2 0 0 0.4 0 4 N Exterior Concrete Block- Int Insul M TOILET 5 3 0 9 4 28.0 ft2 0 0 0.4 0 5 N Exterior Concrete Block- Int Insul M BATH 5 10 0 9 4 93.3 ft2 0 0 0.4 0 _ 6 W Garage Frame - Wood M BATH 11 10 0 9 4 93.3 ft2 0 0.1 0.4 0 _ 7 W Garage Frame -Wood LAUNDRY 11 8 0 9 4 74.7 ft2 0 0.1 0.4 0 _ 8 W Exterior Concrete Block - Int Insul FOYER 5 8 0 14 4 114.7 fN 0 0 0.4 0 _ 9 W Garage Frame -Wood FOYER 11 3 0 14 4 43.0 ft2 0 0.1 0.4 0 10 N Garage Frame -Wood FOYER 11 8 0 14 4 114.7 ft2 0 0.1 0.4 0 _ 11 E Exterior Concrete Block- Int InsIDINING ROO 5 15 0 9 4 140.0 ft' 0 0 0.4 0 _ 12 S Exterior Concrete Block- Int InsIDINING ROO 5 8 0 9 4 74.7 ft2 0 0 0.4 0 _ 13 E Exterior Concrete Block- Int InsuLIVING ROO 5 13 0 9 4 121.3 ft2 0 0 0.4 0 14 S Exterior Concrete Block- Int InsuLIVING ROO 5 15 0 9 4 140.0 ft' 0 0 0.4 0 _ 15 S Exterior Concrete Block- Int InsuBEDROOM 2 5 11 0 9 4 102.7 ft' 0 0 0.4 0 _ 16 S Exterior Concrete Block- Int Insul CLST 2 5 2 0 9 4 18.7 ft2 0 0 0.4 0 _ 17 S Exterior Concrete Block- Int Insul BATH 2 5 6 0 9 4 56.0 ft2 0 0 0.4 0 _ 18 N Exterior Concrete Block- Int Insul DEN 5 6 0 9 4 56.0 ft2 0 0 0.4 0 _ 19 S Exterior Concrete Block- Int Insul DEN 5 6 0 9 4 56.0 ft' 0 0 0.4 0 _ 20 SW Exterior Concrete Block- Int Insul DEN 5 4 3 9 4 39.7 ft2 0 0 0.4 0 _ 21 W Exterior Concrete Block - Int Insul DEN 5 9 0 9 4 84.0 ft2 0 0 0.4 0 22 NW Exterior Concrete Block- Int Insul DEN 5 4 3 9 4 39.7 ft2 0 0 0.4 0 WINDOWS Orientation shown is the entered, Proposed orientation. Wall Overhang V # Omt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 E 2 Vinyl Low-E Single Yes 0.4 0.2 Y 30.0 ft' 2 ft 0 in 1 It 4 in None None 2 N 4 Vinyl Low-E Single Yes 0.4 0.2 Y 6.0 112 2 ft 0 in 1 It 4 in None None 3 N 5 Vinyl Low-E Single Yes 0.4 0.2 Y 6.0 ft' 2 ft 0 in 1 It 4 in None None 4 W 8 Vinyl Low-E Single Yes 0.4 0.2 Y 10.7 ft' 8 ft 0 in 1 ft 4 in None None 5 W 8 Vinyl Low-E Single Yes 0.4 0.2 Y 20.0 ft' 8 ft 0 in 1 It 4 in None None 6 E 11 Vinyl Low-E Single Yes 0.4 0.2 Y 36.0 ft' 2 ft 0 in 1 ft 4 In None None 7 S 12 Vinyl Low-E Single Yes 0.4 0.2 Y 24.0 ft2 6 it 0 in 1 ft 4 in None None 8 E 13 Vinyl Low-E Single Yes 0.4 0.2 Y 64.0 ft2 10 ft 0 in 1 ft 4 in Drapes/blinds None 9 S 14 Vinyl Low-E Single Yes 0.4 0.2 Y 24.0 ft' 10 ft 0 in 1 ft 4 in Drapes/blinds None 10 S 15 Vinyl Low-E Single Yes 0.4 0.2 Y 30.0 ft2 2 it 0 in 1 ft 4 in None None 11 S 17 Vinyl Low-E Single Yes 0.4 0.2 Y 6.0 ft2 2 ft 0 in 1 ft 4 in None None _ 12 SW 20 Vinyl Low-E Single Yes 0.4 0.2 Y 14.2 ft2 2 ft 0 in 1 ft 4 in None None 13 W 21 Vinyl Low-E Single Yes 0.4 0.2 Y 20.0 ft' 2 ft 0 in 1 ft 4 in None None 14 NW 22 Vinyl Low-E Single Yes 0.4 0.2 Y 14.2 ft' 2 ft 0 in 1 ft 4 in None None 5/14/2020 11:03 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6lh Edition (2017) Compliant Software Page 4 of 6 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 504 ft' 504 ft' 29 ft 9 ft 11 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000434 1932.1 106.07 199A8 .1626 7 HEATING SYSTEM # System Type Subtype Speed Efficiency Capacity Block Ducts 1 Electric Strip Heat/ None COPA 27 kBtuthr 1 sys#1 COOLING SYSTEM # System Type Subtype Subtype Efficiency Capacity Air Flow SHR Block Duds 1 Central Unit/ Split Single SEER: 16 30 kBtu/hr 900 cfm 0.8 1 sys#1 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric Tankless Garage 0.99 1 gal 55.1 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Cart # Company Name Collector Storage System Model # Collector Model # Area Volume FEF None None ft' DUCTS # -- Supply-- Location R-Value Area — Return — Air CFM 25 CFM25 Location Area Leakage Type Handler TOT OUT ON RLF HVAC # Heat Cool 1 Attic 6 140 ft' Attic 14 ft' Default Leakage Attic (Default) c(Default) c 1 1 5/ 1412020 11:03 AM EnergyGaugeO USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 5 of 6 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT TEMPERATURES Programablet N Creiling Fans: xThermostat:x� Heating Jan Feb f[�X]'J Mar ( May l% I Jun [X] [ ] Jul [X] [ ] Aug (�j l 1 SeP IrX't Nov [rX'] Dec Venting (I Jan ( l l l l Feb (XJ Mar lxl Apr l I I Jun O Jul [ 1 Aug l 1 Sep Oct [XJ Nov [ ] Dec Thermostat Schedule: HERS 2006 Reference Hours — Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling(WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 80 80 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 80 80 78 78 78 78 78 78 78 78 Heating (WD) AM 65 65 65 65 65 65 65 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 68 68 Heating(WEH) AM 65 65 65 65 65 65 65 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 68 68 MASS Mass Type Area Thickness Furniture Fraction Space Default(8 lbs/sq.ft. 0 ft' Oft 0.3 MASTER BEDROO Default(81bs/sq.ft. ft' ft 0.3 M WIC Default(8 lbs/sq.ft. fF ft 0.3 M TOILET Defaull(81bs/sq.ft. ft' ft 0.3 M BATH Default(81bs/sq.ft. ft' ft 0.3 LAUNDRY Default(8 lbs/sq.ft. ft' It 0.3 FOYER Default(8 lbs/sq.ft. fN ft 0.3 KITCHEN Default(8 lbs/sq.ft. ft2 It 0.3 DINING ROOM Defaull(81bs/sq.ft. ft ft 0.3 LIVING ROOM Default(8 lbs/sq.ft. ft' It 0.3 BEDROOM 2 Default(8 lbs/sq.ft. ft' ft 0.3 CLST 2 Defaull(81bs/sq.ft. ft' ft 0.3 BATH 2 Default(81bs/sq.ft. ft, ft 0.3 DEN Default(8 lbs/s.ft. _ fF ft 0.3 HALL 5/141202011:03 AM EnergyGauger8 USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 6 of 6 FORM R405-2017 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: WIENCKE RESIDENCE Builder Name: Street: LOT A3 VENTURE HARBOR Permit Office: ST LUCIE COUNTY City, State, Zip: JENSEN BEACH, FL, Permit Number: Owner: Jurisdiction: ST LUCIE COUNTY Design Location: FL, Fort Pierce County. St. Lucie (Florida Climate Zone 2 ) 1. New construction or ebsting New (From Plans) 9. Wall Types (1835.7 sqft.) Insulation Area 2. Single family or multiple family Single-family a Concrete Block- Int Insul, Exterior R=5.0 1510.00 fF b. Frame - Wood, Adjacent R=11.0 325.67 fP 3. Number of units, if multiple family 1 c. N/A R= ft2 4. Number of Bedrooms 2 d. N/A R= ft' 10. Ceiling Types (1699.0 sqft.) Insulation Area 5. Is this a worst case? No a. Roof Deck (Un ented) R=19.0 1699.00 ft' 6. Conditioned floor area above grade 1699 b. N/A R= ft' Conditioned floor area below grade (ft� 0 c. N/A R= ft z 11. Ducts R ft 7. Windows (305.0 sqft.) Description Area a. Sup: Attic, Ret: Attic, AH: Attic 6 140 a. U-Factor. SgI, U=0.40 305.00 ft' SHGC: SHGC=0.20 b. U-Factor: N/A ft, 12. Cooling systems kBtu/hr Efficiency SHGC: a Central Unit 30.0 SEER:16.00 c. U-Factor. WA ft' SHGC: 13. Heating systems kBtulhr Efficiency d. U-Factor: N/A fN a. Electric Strip Heat 27.0 COP:1.00 SHGC: Area Weighted Average Overhang Depth: 5.226 ft. Area Weighted Average SHGC: 0.200 14. Hot water systems a. Electric Tankless Cap: 1 gallons 8. Floor Types (1699.0 sgft.) Insulation Area EF: 0.990 a. Slab -On -Grade Edge Insulation R=0.0 1699.00 ft, b. Conservation features b. N/A R= fF None c. N/A R= ft' 15. Credits None Glass/Floor Area: 0.180 Total Proposed Modified Loads: 59.52 PASS Total Baseline Loads: 60.53 I hereby certify that the plans and specifications covered by Review of the plans and STgl� this calculation are in compliance with the Florida Energy specifications covered by this OQ�g y ,l =_ g 0� Code. calculation indicates compliance y iiii zss,° with the Florida Energy Code. rrm . '%. '%,'' _;;•• „ O PREPARED BY: Before construction is completed DATE: 5-15-202 this building will be inspected for. compliance with Section 553.908 • ° n I hereby certify that this building, as designed, is in compliance Florida Statutes. with the Florida Energy Cade. COD Wyt ' OWNER/AGENT: BUILDING OFFICIAL: DATE: DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factorysealed In accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2). 5/14/2020 11:03 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 6 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT PROJECT Title: WIENCKE RESIDENCE Bedrooms: 2 Address Type: Street Address Building Type: User Conditioned Area: 1699 Lot # Owner Name: Total Stories: 1 Block/Subdivision: # of Units: 1 Worst Case: No PlalBook: Builder Name: Rotate Angle: 0 Street: LOT A3 VENTURE HA Permit Office: ST LUCIE COUNTY Cross Ventilation: No County: St. Lucie Jurisdiction: ST LUCIE COUNTY Whole House Fan: No City, State, Zip: JENSEN BEACH, Family Type: Single-family FL, New/F.Asting: New (From Plans) Comment: CLIMATE / Design Temp Int Design Temp Heating Design DailyTemp V Design Location TMY Site 97.5 % 2.5 % Winter Summer Degree Days Moisture Range FL, Fort Pierce FL_VERO_BEACH_MUNI 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume 1 Entire House 1699 16560.7 SPACES Number Name Area Volume Kitchen Occupants Bedrooms Infil ID Finished Cooled Heated 1 MASTER BEDROO 264 2455.2 No 0 1 1 Yes Yes Yes 2 MWIC 54 502.2 No 0 1 Yes Yes Yes 3 M TOILET 30 279 No 0 1 Yes Yes Yes 4 M BATH 124 1153.2 No 0 1 Yes Yes Yes 5 LAUNDRY 68 539.4 No 0 1 No Yes Yes 6 FOYER 152 2173.6 No 0 1 Yes Yes Yes 7 KITCHEN 176 1636.8 Yes 0 1 No Yes Yes 8 DINING ROOM 225 2092.5 No 0 1 Yes Yes Yes 9 LIVING ROOM 211 1962.3 No 0 1 Yes Yes Yes 10 BEDROOM 2 165 1534.5 No 0 1 1 Yes Yes Yes 11 CLST 2 22 204.6 No 0 1 Yes Yes Yes 12 BATH 2 66 613.8 No 0 1 Yes Yes Yes 13 DEN 120 1116 No 0 1 Yes Yes Yes 14 HALL 32 297.6 No 0 1 No Yes Yes FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Slab -On -Grade Edge Insulation MASTER BEDRO 31 It 0 264 ft2 -__ 1 0 0 2 Slab -On -Grade Edge Insulation M WIC E ft 0 54 ft2 1 0 0 3 Slab -On -Grade Edge Insulation M TOILET 3 ft 0 30 ft2 __ 1 0 0 4SIab-On-Grade Edge Insulation M BATH loft 0 124 ft2 1 0 0 5/14/202011:03 AM EnergyGaugerb USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 2 of 6 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 5 Slab -On -Grade Edge Insulation LAUNDRY 1 ft 0 58 ft2 -- 1 0 0 6 Slab -On -Grade Edge Insulation FOYER 8 ft 0 152 ft2 1 0 0 7 Slab -On -Grade Edge Insulation KITCHEN 1 ft 0 176 ft2 1 0 0 8 Slab -On -Grade Edge Insulation DINING ROOM 23 ft 0 225 ft2 1 0 0 9SIab-On-Grade Edge Insulation LIVING ROOM 28 it 0 211 ft2 -_ 1 0 0 10SIab-On-Grade Edge Insulation BEDROOM 2 11 ft 0 165 ft' 1 0 0 11SIab-On-Grade Edge Insulation CLST 2 2 ft 0 22 ft2 __ 1 0 0 12SIab-On-Grade Edge Insulation BATH 2 6 ft 0 66 ft' __ 1 0 0 13SIab-On-Grade Edge Insulation DEN 29.4 ft 0 120 ft2 ___ 1 0 0 14SIab-On-Grade Edge Insulation HALL 1 ft 0 32 ft' __ 1 0 0 ROOF Roof Gable Roof Red Solar SA EmItt Emltt Deck Pitch V # Type Materials Area Area Color Barr Absor. Tested Tested Insul. (deg) 1 Hip Metal 1840 ft' Oft' Light N 0.4 No 0.9 No 19 22.6 ATTIC # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Unvented 0 1699 ft2 N N CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type _ 1 Under Attic (Unvented) MASTER BEDRO 0 Blown 264 ft' 0.1 Wood _ 2 Under Attic (Unvented) MWIC 0 Blown 54 ft2 0.1 Wood 3 Under Attic (Unvented) M TOILET 0 Blown 30 ft' 0.1 Wood 4 Under Attic (Unvented) M BATH 0 Blom 124 ft' 0.1 Wood 5 Under Attic (Unvented) LAUNDRY 0 Blown 58ft' 0.1 Wood 6 Under Attic (Unvented) FOYER 0 Blom 152 ft' 0.1 Wood 7 Under Attic (Unvented) KITCHEN 0 Blom 176 ft' 0.1 Wood 8 Under Attic (Unvented) DINING ROOM 0 Blom 225 ft2 0.1 Wood _ 9 Under Attic (Unvented) LIVING ROOM 0 Blown 211 ft' 0.1 Wood 10 Under Attic (Unvented) BEDROOM 2 0 Blown 165 fN 0.1 Wood _ 11 Under Attic (Unvented) CLST 2 0 Blom 22 ft' 0.1 Wood 12 Under Attic (Unvented) BATH 0 Blown 68 ft2 0.1 Wood _ 13 Under Attic Unvented) DEN 0 Blown 120 ft' 0.1 Wood 14 Under Attic (Unvented) HALL 0 Blown 32 f12 0.1 Wood 5/14/2020 11:03 AM EnergyGaugeO USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 3 of 6 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT WALLS Adjacent Space Cavity Width Height Sheathing Framing Solar Below _ 1 N Exterior Concrete Block- Int InsuMASTER BE 5 15 0 9 4 140.0 ft' 0 0 0.4 0 _ 2 E Exterior Concrete Block- Int InsuMASTER BE 5 16 0 9 4 149.3 ft' 0 0 0.4 0 3 N Exterior Concrete Block- Int Insul M WIC 5 6 0 9 4 56.0 ft' 0 0 0.4 0 4 N Exterior Concrete Block- Int Insul M TOILET 5 3 0 9 4 28.0 ft2 0 0 0.4 0 _ 5 N Exterior Concrete Block- Int Insul M BATH 5 10 0 9 4 93.3 ft' 0 0 0.4 0 _ 6 W Garage Frame - Wood M BATH 11 10 0 9 4 93.3 ft' 0 0.1 0.4 0 7 W Garage Frame -Wood LAUNDRY 11 8 0 9 4 74.7 ft2 0 0.1 0.4 0 _ 8 W Exterior Concrete Block-Int Insul FOYER 5 8 0 14 4 114.7f' 0 0 0.4 0 _ 9 W Garage Frame -Wood FOYER 11 3 0 14 4 43.0 ft' 0 0.1 0.4 0 10 N Garage Frame -Wood FOYER 11 8 0 14 4 114.7 ft' 0 0.1 0.4 0 _ 11 E Exterior Concrete Black - Int InsLOINING ROO 5 15 0 9 4 140.0 ft' 0 0 0.4 0 _ 12 S Exterior Concrete Block - Int InsLOINING ROO 5 8 0 9 4 74.7 ft' 0 0 0.4 0 _ 13 E Exterior Concrete Block- Int InsuLIVING ROO 5 13 0 9 4 121.3 ft' 0 0 0.4 0 _ 14 S Exterior Concrete Block- Int InsuLIVING ROO 5 15 0 9 4 140.0 ft' 0 0 0.4 0 _ 15 S Exterior Concrete Block- Int InsLMEDROOM 2 5 11 0 9 4 102.7 ft2 0 0 0.4 0 _ 16 S Exterior Concrete Block - Int Insul CLST 2 5 2 0 9 4 18.7 ft' 0 0 0.4 0 _ 17 S Exterior Concrete Block- Int Insul BATH 2 5 6 0 9 4 56.0 ft2 0 0 0.4 0 _ 18 N Exterior Concrete Black- Int Insul DEN 5 6 0 9 4 56.0 ft2 0 0 0.4 0 _ 19 S Exterior Concrete Block- Int Insul DEN 5 6 0 9 4 56.0 ft2 0 0 0.4 0 _ 20 SW Exterior Concrete Block - Int Insul DEN 5 4 3 9 4 39.7 ft' 0 0 0.4 0 _ 21 W Exterior Concrete Block - Int Insul DEN 5 9 0 9 4 84.0 ft2 0 0 0.4 0 22 NW Exterior Concrete Block- Int Insul DEN 5 4 3 9 4 39.7 ft2 0 0 0.4 0 WINDOWS Orientation shown is the entered, Proposed orientation. Wall Overhang V # Oml ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 E 2 Vinyl Low-E Single Yes 0.4 0.2 Y 30.0 ft2 2ft01n 1ft4in None None 2 N 4 Vinyl Low-E Single Yes 0.4 0.2 Y 6.0 ft2 2 ft 0 in 1 ft 4 in None None _ 3 N 5 Vinyl Low-E Single Yes 0.4 0.2 Y 6.0 ft' 2 ft 0 in 1 ft 4 in None None 4 W 8 Vinyl Low-E Single Yes 0.4 0.2 Y 10.7 ft2 8 ft 0 in 1 ft 4 in None None 5 W 8 Vinyl Low-E Single Yes 0.4 0.2 Y 20.0 ft2 8 ft 0 in 1 ft 4 m None None 6 E 11 Vinyl Low-E Single Yes 0.4 0.2 Y 36.0 ft2 2 ft 0 in 1 ft 4 In None None 7 S 12 Vinyl Low-E Single Yes 0.4 0.2 Y 24.0 ft' 6 ft 0 in 1 ft 4 in None None 8 E 13 Vinyl Low-E Single Yes 0.4 0.2 Y 64.0 ft2 10 ft 0 in 1 ft 4 in Drapes/blinds None 9 S 14 Vinyl Low-E Single Yes 0.4 0.2 Y 24.0 ft' 10 ft 0 in 1 ft 4 in Drapes@Iinds None 10 S 15 Vinyl Low-E Single Yes 0.4 0.2 Y 30.0 ft2 2 ft 0 in 1 ft 4 in None None 11 S 17 Vinyl Low-E Single Yes 0.4 0.2 Y 6.0 ft' 2 ft 0 in 1 ft 4 in None None 12 SW 20 Vinyl Low-E Single Yes 0.4 0.2 Y 14.2 ft' 2 ft 0 in 1 ft 4 in None None 13 W 21 Vinyl Low-E Single Yes 0.4 0.2 Y 20.0 ft' 2 ft 0 in 1 ft 4 in None None 14 NW 22 Vinyl Low-ESingle Yes 0.4 0.2 Y 14.2 ft2 2ft0in 1ft4in None None 5/14/2020 11:03 AM EnergyGaugeS USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 4 of 6 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 504 ft' 504 ft' 29 ft 9 ft 11 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000434 1932.1 106.07 199.48 .1626 7 HEATING SYSTEM # System Type Subtype Speed Efficiency Capacity Block Ducts 1 Electric Strip Heat/ None COPA 27 kBtu/hr 1 sys#1 COOLING SYSTEM # System Type Subtype Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unitt Split Single SEER: 16 30 kBlu/hr 900 cfm 0.8 1 sys#1 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric Tankless Garage 0.99 1 gal 55.1 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Cent # Company Name Collector Storage System Model # Collector Model # Area Volume FEF None None fl' DUCTS / V # ----Supply--- Location R-Value Area --Return--- Air CFM 25 CFM25 Location Area Leakage Type Handler TOT OUT ON RLF HVAC# Heat Cool 1 Attic 6 140 ft' Attic 14 ft' Default Leakage Attic (Default) c(Defaull) c 1 1 5/14/2020 11:03 AM EnergyGaugeO USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 5 of 6 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT TEMPERATURES Programable(rXThermostat: N Ceiling Fans:Cooling Jan:X Venting Jan Febrl�, Feb Mar r May lrX Jun IrX Jul rt Aug Aug ri Sepr Sep rp�, Oct Dec rpC'� Dees [ [ [XJ pr [ [ [ [x� [X]No [ ] Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (VVD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 80 80 78 78 78 78 78 78 78 78 Cooling(WEH) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 80 80 78 78 78 78 78 78 78 78 Heating(WD) AM 65 65 65 65 65 65 65 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 68 68 Heating (WEH) AM 65 65 65 65 65 65 65 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 68 68 MASS Mass Type Area Thickness Furniture Fraction Space Default(8 Ibs/sq.ft. Oft- Oft 0.3 MASTER BEDROO Default(8 lbs/sq.ft. ft2 It 0.3 M WIC Default(8 lbs/sq.ft. ft2 It 0.3 M TOILET Default(8 lbs/sq.ft. ft2 It 0.3 M BATH Default(8 lbslsq.ft. ft2 i ft 0.3 LAUNDRY Default(8 lbs/sq.fl. ft2 It 0.3 FOYER Default(8 lbs/sq.ft. ft2 ft 0.3 KITCHEN Default(8 lbslsq.ft. ft2 ft 0.3 DINING ROOM Default(8 lbs/sq.ft. ft2 It 0.3 LIVING ROOM Default(8 lbslsq.ft. ft2 It 0.3 BEDROOM 2 Default(8 lbs/sq.ft. ft2 ft 0.3 CLST 2 Default(8 lbs/sq.ft. ft2 ft 0.3 BATH 2 Default(8 lbs/sq.ft. ft2 It 0.3 DEN Defaull8lbs/s .ft. ft, ft 0.3 HALL 5/14/2020 11:03 AM EnergyGaugeCU USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 6 of 6