Loading...
HomeMy WebLinkAboutcompaction testHeadquarters 11345 U.S. Highway 1 Sebastian, FL. 32958 Orlando 723 Progress Way Sanford, FL. 32771 IV CP IL 2 ENGINEERING £.I1VL AND TESTING SOIL COMPACTION REPORT ASTM D 1557 and ASTM D 6938 Mailing P0 Box 78-1377 Sebastian, FL. 32978 Phone: 772-589-0712 C.A.# 5693 KSMengineering.net DATE TESTED: CONTRACTOR: May 22, 2020 Horizon Pools KSM JOB # 202355-1pd/SH/jo PERMIT #: 1912-0019 JOB LOCATION: 9207 Champions Way NUC# 528 PGA Village Nuc Model: MC- 10 R- P Port St Lucie, Florida Nuc Serial #: M D049528 ITEM TESTED Pool Backfill Compaction TEST LOCATION PEN DRY MAX. DRY PERCENT DEPTH OF SAMPLE READ DENSITY PROCTOR VALUE COMPACTION 1 West 0,-il 37 105.6 109.1 96.8% 2 11 21 38 95.0%+ 3 21 31 39 95.0%+ 4 3141 39 95.0%+ 5 South 0,-il 36 105.1 109.1 96.3% 6 1-2' 37 95.0%+ 7 2-3 38 95.0%+ 8 3,4, 39 95.0%+ 9 East 0,-il 38 106.1 109.1 97.3% 10 11 21 38 95.0%+ 11 2'-3' 39 95.0%+ 12 3,4, 40 95.0%+ Soil Description: Brown Sand W 111.0 E In Place Moisture: G 110.0 10.9% H Proctor Optimum Moisture: TD R109.0 PY j C 108.0 F I I 11.0% Proctor Max. Dry Density: P.C.F. 109.1 @ Test Locations the Density & Penetrometer reading indicate the Degree of Compaction Meets Minimum 1ljeauirem iI7j j'lJn 106.0 8 9 10 11 12 13 14 Moisture - % of Dry Weight Disclaimer: Contractor is responsible to maintain the pool backfill in the condition that KSM completed the indicated passed compaction test. KSM is not responsible if the poolbackfill has been hcg altered from the approved inspected condition. PE # 81439 5/26/2020 Email to: St Lucie Building Department; horizonpools.sandy@gmail.com Proudly Serving Florida since 1990 NO. 8143