Loading...
HomeMy WebLinkAboutPlan Review Revised Plans1/4" D THRU BOLT W/ 1-1/4" 0 WASHER @ 10" O.C. 6- TH,IIC - OF 0 BOLTS ilke�REQ'D FOR 6" TH C ROOF PANELS o(� 1� (�Myao' roeoYe-ENe FnCry wa5HE-� o 0 O o 0 �.0 O Od) O _ CONTINUOUSANGLE 5"COMPOSSEIT ROOF PANEL 2"X2"X1/8"FOR EDGE BEAMS us /tCEFS 0 Oka 632 SKta FOR INTERMEDIATE BEAMS r 2' X 2" X 3/16" THICK W/ #14 SMS @ 6" O.C. (TYPICAL) NOTE: THE 2"X2"Xl/8" CONTINUOUS ANGLE MAY BEAM SELECTED FROM TABLE � BE ELIMINATED BY BOLTING THE COMPOSITE 402 (MAY BE HOLLOW OR PANELS THRU THE SUPPORTING BEAM SELF-MATING/LAP EXTRUSION -- SECTION ROOF PANEL FASTENING DETAIL #2. (COMPOSITE PANELS) q✓tYCOMPOSITE ROOF PANEL L+jt Cali * • o$y. ht-t,V RECEIVING CHANNEL WITH TOP AND4807TOM@ 10" O.C7 1 0 O 0 0 CD o0 CO 0 0 00 EXISTING MASONRY FASTEN TO FASCIA WITH OR WOOD FRAMED Ya"0 X 2Vz" LAGS 1P' ON CENTER a' HOST STRUCTURE ALONG HEADER PERIMETER WALL NOTE: FASCIA MUST BE 2" NOMINAL, A 1" NOMINAL FASCIA MAY BE 't• AUGMENTED TO 2". COMPOSITE ROOF PANEL CONNECTION TO HOST FASCIA ROOF PANELS (SELECT ROOF PANELS (SELECT /— PER TABLE 401) / -- PER TABLE 401) 7" 7 =.3; -7 �/"-7-T T 7-`' T ? ? 7 I BOLof T THROUG BOTH FLANGES OF ( I POST. AND BOTH WEBS OF EDGE BEAM i I POST FLANGE - REMAINS INTACT ( I EDGE BEAM I I 2x'SY.,a4s old z?clplc.a5om tZo I ( I EDGE BEAM ( I ha=� Pt-•t•>a � s�.a-7rioyt,a I I — I I I I I I SEL+ 'P�nL � 5 Ecst oLJ . SECTION (WALL FACE) ELEVATION EDGE BEAM FASTENING DETAIL - DIRECT CONNECTION / HOLLOW POST i X 2 OB @ PERIMETER NOTE #1: USE 1/4" 0 X 3" LONG LAGS INTO WOOD HOST AND \ 1/4"0 X 21/4" LONG CONCRETE SCREWS INTO CONCRETE OR \ MASONRY CONSTRUCTION (1" EMBEDMENT TYPICAL)/ SPACING 24" O.C. AND WITHIN 4" OF EACH PERPENDICULAR MEMBER \� 1" X i" X 1/8" ANGLES 2" LONG WITH 248 X i/2" LONG S.M.S. AT EACH LEG TYPICAL EACH SIDE TOP & BOTTOM) Z"rg;' uiP,% CHAJK30&- W 0' •tr IA•art'`' 'ii CZ) 3/ a 14 7(}eu gct-T5 Ji05 F 5TRUCTi1RE ELEMENTS a ' d COLUMN 3fPt/`aJ ht;CYtoN THICKNESS AND LENGTH OF ANGLES CONCRETE ANCHORS, Z i& 'ri' EnP t3ot.T5 @ 2><� QasTZ �$YT�' PoST'CI EncH41D6� v� PLACEMENT OF 1X2 SOLE PLATE INCIDENTAL TO DESIGN O _ ti L-------- ---- = v ' ¢ J i w H FACE OF WALL w PRODUCT REVIEW PRODUCT OPENING DESIGN PRODUCT MANUFACTURER MODEL# APPROVAL# GLASS ATTACHMENT METHOD PRESSURES (WORST CASE) DESIGN PRESSURES TYPE WINDOW AND DOOR ZONE 4-24.2 ZONES •30.2 -14.4 WINDOW -VINYL WIND N1005904A-R4 VINYL SCREWS 6" FROM END AND 17" O.C. CRAFTSMAN BREAKER WI DO WINDOW (VINYL) PANELS TO BE REMOVED IN WINDS AS PER LATEST REVISION OF RULE 90.72, WIND BREAKERS ARE NO LONGER REQUIR EXCEEDING 75 MPH REFERENCE 98-72.010 (31) (b) WIND BREAKERS ARE NO LONGER A SUB CATEGORY TOP VIEW EDGE OF CONCRETE ----- __ COLUMN TO CONCRETE FASTENING (DETAIL DEPICTS BEARING WALL ONLY) _ COLUMN WCz) 3/$ 0 fCIC11 I CONCRETE ANCHORS, BOLTS THROUGH COLUMN PLACEMENT OF 1X2 SOLE ( T-1" X 2" OB SOLE PLATE PLATE INCIDENTAL TO DESIGN —�• 1 w� • 2,500 PS11 1/4" 0 X ZWNG APPROVED i" (OR LESS) CONCRETE CONCRETE ANCHORS @ 24" (TYPICAL) O.C. (TYPICAL) WALL FACE ELEVATION COLUMN TO CONCRETE FASTENING \� - Certification for Des Load Compliance C�T!`�Q ( T� Snr� P-00�°1 1. DESIGN CODE: Florida LVErN/4Ycode 2017 Edition w/20_ supplements using ASCE 7.10 • ° 2. Structure Design is: Enclosed_ partially Enclosed Open Building CONNECTION WITH EXPOSED FASTENERS 3. Risk Category: _�< 1 III III IV Exposure Cateo B 4C 9 ry — t �D Adjustment coefficient fit 4. Design Wind Velocity mph _ASO _LRFD End Zone Width �' ft. S. Mean Roof Height: I Z ft, Roof Pitch:2iL•h12 Parapet—ft. f 6. Components & Cladding Design Pressure used: (PSF, based on Actual sq. ft. @ 30 'MRH (worst case) 1 X 2 OB @ PERIMETER Zone 1:-�r2 Zone 2:,&'iZone 3: 50.( Zone 4:-M,ZZone 6: 341L Garage: OhA REFER TO NOTE #1-THIS SHEEP 7. Design Loads: Floor: 7✓5 PSF Roof/Dead: 3 PSF Roof/Live 1i PSF Balcony_PSF Dock: _PSF Deck: •_ PSF Stairs: _ PSF Fence: _ PSF Railing: /yfA7 2- # 10 S.M.S. FROM INSIDE FACE OF 8. Were Shear Walls Considered for Structure? Yes _ pgp —Not Applicable Explain Why Not: 1 X 2 OB INTO SCREW SPLINES OF 9. Is a Continuous Load Path provided? Yes _Not applicable Explain Why Not: / I X 2 OB (1" EMBEDMENT MINIMUM.) 10. Minimum soil bearing pressure 2000 P.S,F. 3teot-tqcY-rT'E eooF• w/ I 1 I #FPS CARE • r o32 1 trr .� 5ktta •HOST411UCT;UREJELEM�0TS °. ZK3X , o A 5 F t't i CONNECTION WITH CONCEALED FASTENERS , I F toQ• t Q� Co L.-a�s s I . PARTIAL ELEVATIONS / 1X2 TO IX2 CONNECTIONS A- 2F bxro4S ' rr , 3x3x.o5o I • CLo L i /9 AC`fgi-IC.- wtWDow 'ax3x aoGo° C�2t' 6Er-Y EN 51 Zx3x- o0•IrOa4At2 _. (' KlUICK PGP2fE- FZ ` -• ' w/ I�.f 11•.a Frc.r..a:-f� eo..°� II — � Da ill` (f1( @fit o�of c, I g�['oLNCP��E 4coc tc )%� FOUNDATION SCHEDULE I ��-o'te•c f Lti ftt,Lt� crtc_ S-1 4"'(3000 PSI ) POURED CONCRETE SLAB WITH FIBERMESH _ l ( 1' •l t 1 I t ( ( i I ILI _ REINFORCING ON .006" VAPOR BARRIER OVER CLEAN COMPACTED TREATED FILL F-1 12r' X 12" THICKENED EDGE WITH 1 # 5 BAR CONTINUOUS. F-2 12" DEEP X 16" WIDE SPREAD FOOTING WITH 2 # 5 BARS_ CONTINUOUS. F3 16'r DEEP X 18'r WIDE SPREAD FOOTING WITH 3 # 5 BARS CONTINUOUS. D-1 # 5 DOWEL DRILLED 4" MIN. INTO EXISTING BLOCK SET IN FO 13 fJ Q /�. l (�i �N EPDXY. D-2 3 # 5 DOWELS DRILLED 6" MIN. INTO EXISTING FOUNDATION SET IN EPDXY AND TIED TO NEW FOOTING STEEL. S t DE- C1 GcJ /a•T' f o t� °i-ttEe- htDE •?IMfr.•p.W L/err r4ee�t VA ACCYW d- w l NDdu�j . / I ~�� l44ur.r1, (G,t C k- �LA'iEt----••� yy.t bkY`'Trf:>Go � J j 6tt� C7 rtv- AegYL(a ' .. I 1 I BMXr'oS4Wilt i coMFEdvr° �T�over� I .. • P,ErLa�alaL� S eow Aq t-/ e-r- Aa-o-F- C-i e 3) EGAvt L '^C-EEC . I_ C 3) r-6wAcl_ G, PA c e. e, ;5 ARCHITECT Architectonic Inc 806 DELAWARE AVENUE FORT PIERCE, FLORIDA 34950 T: 772 460 7751 F: 772 460 4244 W W W.ARCHITECTONICINC.COM STATE REG # AA26003348 COPYRIGHT 2020 PROJECT GERMANO PORCH ST. LUCIE COUNTY, FLORIDA CLIENT CONSULTANTS REGISTRATION I MICHAEL J. SEAL, AIA AR96898 REVISIONS NO. DATE REVISION 1 ;%/ro Zcm ep z P-e I KEY PLAN SHEET TITLE / SHEET NUMBER PROJECT NUMBER Z p v t O DATE 2/2t 2oLo