Loading...
HomeMy WebLinkAboutDesign PressuresProperty Information Owner:Miller Address:54 Ipanema Way Ft Pierce, Fl 34951 Building Information Wind Zone:160 MPH. Exposure Category:B Minimum Building Dimension:24 ft. Mean Roof Height:15 ft. Risk Category:II Design Pressure Calculations Opening Number Location Zone Device Width (in) Device Height (in) Device Elevation (ft) Max Positive Pressure (psf) Max Negative Pressure (psf) 1 End 126 82 7 28.3 -35.2 2 Int 67 82 7 29.7 -32.4 3 Int 26 38 7 32.5 -35.2 4 Int 26 38 7 32.5 -35.2 5 Int 74 63 7 30.0 -32.8 6 Int 113 84 7 28.5 -31.3 7 End 102 84 7 28.7 -36.0 8 End 108 82 7 28.6 -35.8 9 Int 53 55 7 31.0 -33.7 10 Int 53 55 7 31.0 -33.7 11 End 60 82 7 29.9 -38.3 Prepared in accordance with: ASCE 7-10, Chapter 30. Wind Loads - Components and Cladding. 6th Edition (2017) Florida Building Code. Page 1 of 1