Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Design Pressure Report (Carlin) - Master Craft Aluminum Products
Property Information Owner:Carlin Address:68 Calle de Lagos Ft Pierce, Fl 34951 Building Information Wind Zone:160 MPH. Exposure Category:B Minimum Building Dimension:24 ft. Mean Roof Height:15 ft. Risk Category:II Design Pressure Calculations Opening Number Location Zone Device Width (in) Device Height (in) Device Elevation (ft) Max Positive Pressure (psf) Max Negative Pressure (psf) 1 End 53 62 7 30.7 -40.0 2 Int 53 56 7 31.0 -33.7 3 Int 53 56 7 31.0 -33.7 4 Int 72 80 7 29.6 -32.3 5 Int 74 55 7 30.3 -33.0 Prepared in accordance with: ASCE 7-10, Chapter 30. Wind Loads - Components and Cladding. 6th Edition (2017) Florida Building Code. Page 1 of 1