HomeMy WebLinkAboutBLOWER DOORDate:
Contractor:
dld
Planning & Development Seruices
Euilding & Code Regulation Division
2300 Virginia Ave, Rm 201
Fort Pierce, Ft 34982
Phone: 772-462-2165 Fax: 772-162-6442
BLOWER DOOR TEST FORM
House lnfiltration Test Certification
Prescriptive and Performance Method
ig
Permit #:CL c- tqog-o-7 (7
'7 /h.l*Job Address:
Construction:( t') New Construction - Complete ( ) Existing - After Addition
House lnfiltration Test Results SLC Climate Zone2
Test Date:CFM {50} =
Volume =
7-ss
ACH (5O) = €FM (5Olx6O I Volume =4.2 Mechonicql Ventilation required less than 3 ACH
jle"rr { )FailPassing results must be & ACH (5O) or less
FBC, Energy
The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceedin g7 air changes per
hour in Climate Zone 1,2 and 3 air changes per hour in Climate Zones 3 through 8. Testing shall be conducted with a
blower door at a pressure of 0-2 inches w. g. (50 Pascals|. Testing shall be conducted by either individuals as defined in
Section 553.993{5) or {7), Florida Statutes or individuals licensed as set forth in Section 489.105 (3Xf}, (e) or (i) or an
approved third party. A written report of the results of the test shall be signed by the party conducting the test and
provided ta the code officiol. Testing shall be performed at any time after creation of all penetrations of the buitding
thermal envelope.
FBC, Residential
Where the air infiltration rate of a dwelling unit is less than 3 air changes per hour when tested with a blower rloor at a
pressure of 0'2 inch w. c. {50 Pa} in accordance with Section R4O2.4.7.2 of lhe Florida Buitding Code, Energy Conservstion
the dwelling unit shall be provided with whole-house mechanical ventilation in accordance with Section M1507.3.
Testlnp Companv
Company Name: Florida Energy Testin& Address:
I hereby certify that the above House lnfiltration results demonstrate compliance with FBC Energy Conservation
requirements in accordance with Climate Zane 2
Signature:
Printed Name:stel{ ?* I
LicenselCertification #:
p t-a,
taa65;."' P,J*5.tfu€ FV