Loading...
HomeMy WebLinkAboutDesign Pressure Report (Digiuseppi) - Master Craft Aluminum ProductsProperty Information Owner:Digiuseppi Address:2510 S Brocksmith Rd Ft Pierce, Fl 34945 Building Information Wind Zone:160 MPH. Exposure Category:B Minimum Building Dimension:30 ft. Mean Roof Height:15 ft. Risk Category:II Design Pressure Calculations Opening Number Location Zone Device Width (in) Device Height (in) Device Elevation (ft) Max Positive Pressure (psf) Max Negative Pressure (psf) 1 Int 74 85 7 29.4 -32.1 2 Int 75 129 7 28.5 -31.2 3 Int 74 85 7 29.4 -32.1 4 Int 53 62 7 30.7 -33.5 5 Int 53 62 7 30.7 -33.5 6 Int 53 62 7 30.7 -33.5 7 Int 26 62 7 32.2 -35.0 8 Int 26 62 7 32.2 -35.0 9 Int 72 60 7 30.2 -32.9 10 Int 295 98 7 26.1 -28.9 11 Int 108 60 7 29.3 -32.1 12 Int 37 50 7 32.0 -34.7 13 Int 48 62 7 30.9 -33.7 14 Int 48 62 7 30.9 -33.7 15 Int 36 62 7 31.6 -34.3 16 Int 36 62 7 31.6 -34.3 17 Int 53 50 7 31.2 -33.9 18 Int 36 38 7 32.5 -35.2 Prepared in accordance with: ASCE 7-10, Chapter 30. Wind Loads - Components and Cladding. 6th Edition (2017) Florida Building Code. Page 1 of 1