HomeMy WebLinkAboutEnergy CodeEnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 54/10/2020 8:54 AM
Project Name:
Owner:
Builder Name:
Permit Office:
Jurisdiction: ST. LUCIE COUNTY
ST. LUCIE COUNTY
RICHARD & VICKEY WALKER
RICHARD AND VICKEY WALKER
Street:
City, State, Zip: FT. PIERCE , FL ,
2214 N. 45tH STREET
Permit Number:
Design Location: FL, Fort Pierce County: St. Lucie (Florida Climate Zone 2 )
1. New construction or existing
2. Single family or multiple family
3. Number of units, if multiple family
4. Number of Bedrooms
5. Is this a worst case?
6. Conditioned floor area above grade (ft²)
Addition
Single-family
1
No
684
7. Windows
a. U-Factor:
S H G C :
b. U-Factor:
S H G C :
c. U-Factor:
S H G C :
d. U-Factor:
S H G C :
Sgl, U=0.65 57.00 ft²
SHGC=0.25
N/A f t ²
N/A f t ²
N/A f t ²
8. Floor Types
a. Slab-On-Grade Edge Insulation
b. N/A
c. N/A
R=0.0 684.00 ft²
R=f t ²
R=f t ²
9. Wall Types
a. Concrete Block - Ext Insul, Exterior R=4.1 912.00 ft²
b. N/A R=f t ²
c. N/A R=f t ²
10. Ceiling Types
a. Under Attic (Vented)R=30.0 684.00 ft²
f t ² R=b. N/A
c. N/A R = f t ²
11. Ducts
a. Sup: Attic, Ret: Attic, AH: GREAT ROOM
12. Cooling systems
13. Heating systems
14. Hot water systems
a. Electric Cap: 50 gallons
b. Conservation features
None
d. N/A R=f t ²
Area Weighted Average Overhang Depth:2.000 ft.
Area Weighted Average SHGC:0.250
Description Area
Insulation Area
Insulation Area
Insulation Area
15. Credits None
-
(Bedrms In Addition) 2(0)
(57.0 sqft.)
(912.0 sqft.)
(684.0 sqft.)
(684.0 sqft.)
Conditioned floor area below grade (ft²) 0
a. Central Unit
a. Electric Strip Heat
k B t u / h r
22.0 SEER:13.00
Efficiency
k B t u / h r Efficiency
17.0 COP:1.00
f t ² R
6 105
EF: 0.950
Glass/Floor Area: 0.083
Total Proposed Modified Loads:
Total Baseline Loads:
25.93
26.31 PASS
I hereby certify that the plans and specifications covered by
this calculation are in compliance with the Florida Energy
Code.
PREPARED BY:
DATE:
I hereby certify that this building, as designed, is in compliance
with the Florida Energy Code.
OWNER/AGENT:
DATE:
BUILDING OFFICIAL:
DATE:
Review of the plans and
specifications covered by this
calculation indicates compliance
with the Florida Energy Code.
Before construction is completed
this building will be inspected for
compliance with Section 553.908
Florida Statutes.
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory-sealed in accordance with R403.3.2.1.
- Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires
an envelope leakage test report with envelope leakage no greater than 5.00 ACH50 (R402.4.1.2).
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
FORM R405-2017
4-10-2020
PROJECT
Title:
Owner Name:
# of Units:
Builder Name:
Permit Office:
Jurisdiction: ST. LUCIE COUNTY
ST. LUCIE COUNTY
1
RICHARD & VICKEY WALKE
RICHARD AND VICKEY WAL
Family Type:
New/Existing:
Bedrooms:
Conditioned Area:
Total Stories:
Worst Case:
Rotate Angle: 0
No
1
684
2
Addition
Single-family
Address Type:
Lot #
Block/Subdivision:
PlatBook:
Street:
County:
City, State, Zip:
FL ,
FT. PIERCE ,
St. Lucie
2214 N. 45tH STREET
Street Address
Comment:
Building Type: User
Cross Ventilation: No
Whole House Fan: No
TMY Site
Design Temp Int Design Temp Heating Design Daily Temp
Design Location 2.5 %97.5 % Degree Days Moisture RangeWinter Summer
CLIMATE
90 70 75 299 62 Low39FL_VERO_BEACH_MUNIFL, Fort Pierce______
Number Name Area Volume
BLOCKS
1 Entire House 684 5472
Number Name Area Volume
SPACES
Kitchen Occupants Bedrooms Cooled HeatedInfil ID Finished
1 LAUNDRY 84 672 No 0 Yes Yes1 Yes
2 KITCHEN 120 960 Yes 0 Yes Yes1 Yes
3 BATH 40 320 No 0 Yes Yes1 Yes
4 BEDROOM 2 123 984 No 1 1 Yes Yes1 Yes
5 BEDROOM 1 129 1032 No 1 1 Yes Yes1 Yes
6 GREAT ROOM 188 1504 No 2 Yes Yes1 Yes
# Floor Type Area Tile Wood Carpet
FLOORS
Perimeter R-Value Joist R-ValueSpace Perimeter
1 84 ft² 0 1 0______ Slab-On-Grade Edge Insulation - - - -026 ft LAUNDRY
2 120 ft² 0 1 0______ Slab-On-Grade Edge Insulation - - - -012 ft KITCHEN
3 40 ft² 0 1 0______ Slab-On-Grade Edge Insulation - - - -05 ft BATH
4 123 ft² 0 1 0______ Slab-On-Grade Edge Insulation - - - -022 ft BEDROOM 2
5 129 ft² 0 1 0______ Slab-On-Grade Edge Insulation - - - -024 ft BEDROOM 1
6 188 ft² 0 1 0______ Slab-On-Grade Edge Insulation - - - -025 ft GREAT ROOM
4/10/2020 8:54 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 2 of 5
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
# Type Materials Color Absor.
Roof Solar Deck
Insul.
Pitch
ROOF
Tested
Roof
Area
Gable
Area
Emitt
Tested
EmittSA
(deg)
Rad
Barr
1 Hip Composition shingles 721 ft² Medium 0.5 0 18.4______ No0 ft² 0.9 NoN
ATTIC
# Type Ventilation Area RBS IRCCVent Ratio (1 in)
______ 1 Full attic Vented 684 ft² N N150
# Ceiling Type R-Value Area Framing Frac Truss Type
CEILING
Space Ins Type
1 Under Attic (Vented) 30 84 ft² 0.1 Wood______ LAUNDRY Blown
2 Under Attic (Vented) 30 120 ft² 0.1 Wood______ KITCHEN Blown
3 Under Attic (Vented) 30 40 ft² 0.1 Wood______ BATH Blown
4 Under Attic (Vented) 30 123 ft² 0.1 Wood______ BEDROOM 2 Blown
5 Under Attic (Vented) 30 129 ft² 0.1 Wood______ BEDROOM 1 Blown
6 Under Attic (Vented) 30 188 ft² 0.1 Wood______ GREAT ROOM Blown
WALLS
# Wall Type R-Value Area
Adjacent Framing Solar
Ornt Fraction Absor.
HeightWidth
Ft In Ft InTo
Cavity Sheathing
R-ValueSpace Grade%
Below
1 4.1 0LAUNDRY 00012 8N Concrete Block - Ext Insul 0.60Exterior 96.0 ft² ____
2 4.1 0LAUNDRY 0007 8E Concrete Block - Ext Insul 0.60Exterior 56.0 ft² ____
3 4.1 0LAUNDRY 0007 8W Concrete Block - Ext Insul 0.60Exterior 56.0 ft² ____
4 4.1 0KITCHEN 00010 8E Concrete Block - Ext Insul 0.60Exterior 80.0 ft² ____
5 4.1 0KITCHEN 0002 8W Concrete Block - Ext Insul 0.60Exterior 16.0 ft² ____
6 4.1 0BATH 0005 8E Concrete Block - Ext Insul 0.60Exterior 40.0 ft² ____
7 4.1 0BEDROOM 2 00011 8E Concrete Block - Ext Insul 0.60Exterior 88.0 ft² ____
8 4.1 0BEDROOM 2 00011 8S Concrete Block - Ext Insul 0.60Exterior 88.0 ft² ____
9 4.1 0BEDROOM 1 00013 8S Concrete Block - Ext Insul 0.60Exterior 104.0 ft² ____
10 4.1 0BEDROOM 1 00011 8W Concrete Block - Ext Insul 0.60Exterior 88.0 ft² ____
11 4.1 0GREAT ROO 00012 8N Concrete Block - Ext Insul 0.60Exterior 96.0 ft² ____
12 4.1 0GREAT ROO 00013 8W Concrete Block - Ext Insul 0.60Exterior 104.0 ft² ____
# Door Type U-Value AreaStorms
DOORS
Ornt Space
Width
Ft In Ft In
Height
1 Insulated .39 20 ft² None______ N LAUNDRY 863
2 Insulated .39 20 ft² None______ W GREAT ROO 863
4/10/2020 8:54 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 3 of 5
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
# Ornt Panes NFRC U-Factor SHGC Area Depth Separation Int ShadeFrame Screening
WINDOWS
Overhang
Orientation shown is the entered, Proposed orientation.
Wall
ID Imp
1 E Low-E Single 0.65 0.25 12.0 ft² 2 ft 0 in 1 ft 4 in NoneMetal None______ Yes4 N
2 E Low-E Single 0.65 0.25 15.0 ft² 2 ft 0 in 1 ft 4 in NoneMetal None______ Yes7 N
3 W Low-E Single 0.65 0.25 15.0 ft² 2 ft 0 in 1 ft 4 in NoneMetal None______ Yes10 N
4 W Low-E Single 0.65 0.25 15.0 ft² 2 ft 0 in 1 ft 4 in NoneMetal None______ Yes12 N
Method CFM 50 ACH 50ELASLAScope
INFILTRATION
ACHEqLA#
456 525.03.000254Wholehouse .088147.08Proposed ACH(50)1
HEATING SYSTEM
# System Type Efficiency Capacity DuctsSubtype BlockSpeed
1 Electric Strip Heat/None (Basel COP:1 17 kBtu/hr ______ sys#1None 1
# System Type Efficiency Capacity Air Flow SHR
COOLING SYSTEM
DuctsSubtype BlockSubtype
1 Central Unit/None (Baseline as SEER: 13 22 kBtu/hr c f m 0.7______ sys#1Split 1 Single
# System Type EF Cap Use SetPnt Conservation
HOT WATER SYSTEM
SubType Location
1 Electric 0.95 50 gal 60.9 gal 120 deg None______ None LAUNDRY
FSEC
Company Name System Model # Collector Model #
Collector
SOLAR HOT WATER SYSTEM
Storage
FEFCert # Area Volume
None None f t ² ______
# Location R-Value Area Location Area
---- Supply ---- ---- Return ----
Leakage Type Handler
CFM 25Air
QN RLF
DUCTS
Heat Cool
HVAC #
TOT OUT
CFM25
1 Attic 6 105 ft² Attic 65 ft² Default Leakage GREAT RO (Default) c______ 1 1 (Default) c
4/10/2020 8:54 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 4 of 5
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
TEMPERATURES
Programable Thermostat: N Ceiling Fans:
Cooling [ ] Jan [ ] Feb [ ] Mar [ ] Apr [ ] May [X] Jul [X] Aug [X] Sep [ ] Oct [ ] Nov [ ] Dec
[ ] Dec[X] Dec[X] Nov[X] Nov[ ] Oct[X] Oct[ ] Sep[ ] Sep[ ] Aug[ ] Aug[ ] Jul[ ] Jul[ ] Jun[ ] Jun[X] Jun[ ] May[ ] May[ ] Apr[X] Apr[X] Mar[X] Mar[X] Feb[ ] Feb[X] Jan[ ] JanHeatingVenting
Thermostat Schedule: HERS 2006 Reference Hours
Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12
Cooling (WD) AMPM 7880 7880 7880 7880 7878 7878 7878 7878 8078 8078 8078 8078
Cooling (WEH) AMPM 7880 7880 7880 7880 7878 7878 7878 7878 8078 8078 8078 8078
Heating (WD) AMPM 6568 6568 6568 6568 6568 6568 6568 6868 6868 6868 6868 6868
Heating (WEH) AMPM 6568 6568 6568 6568 6568 6568 6568 6868 6868 6868 6868 6868
MASS
Mass Type Area Thickness Furniture Fraction Space
Default(8 lbs/sq.ft. 0 ft² 0 ft 0.3 LAUNDRY
Default(8 lbs/sq.ft. f t ² f t 0.3 KITCHEN
Default(8 lbs/sq.ft. f t ² f t 0.3 BATH
Default(8 lbs/sq.ft. f t ² f t 0.3 BEDROOM 2
Default(8 lbs/sq.ft. f t ² f t 0.3 BEDROOM 1
Default(8 lbs/sq.ft. f t ² f t 0.3 GREAT ROOM
4/10/2020 8:54 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 5 of 5
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT