Loading...
HomeMy WebLinkAboutEnergy CodeEnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 54/10/2020 8:54 AM Project Name: Owner: Builder Name: Permit Office: Jurisdiction: ST. LUCIE COUNTY ST. LUCIE COUNTY RICHARD & VICKEY WALKER RICHARD AND VICKEY WALKER Street: City, State, Zip: FT. PIERCE , FL , 2214 N. 45tH STREET Permit Number: Design Location: FL, Fort Pierce County: St. Lucie (Florida Climate Zone 2 ) 1. New construction or existing 2. Single family or multiple family 3. Number of units, if multiple family 4. Number of Bedrooms 5. Is this a worst case? 6. Conditioned floor area above grade (ft²) Addition Single-family 1 No 684 7. Windows a. U-Factor: S H G C : b. U-Factor: S H G C : c. U-Factor: S H G C : d. U-Factor: S H G C : Sgl, U=0.65 57.00 ft² SHGC=0.25 N/A f t ² N/A f t ² N/A f t ² 8. Floor Types a. Slab-On-Grade Edge Insulation b. N/A c. N/A R=0.0 684.00 ft² R=f t ² R=f t ² 9. Wall Types a. Concrete Block - Ext Insul, Exterior R=4.1 912.00 ft² b. N/A R=f t ² c. N/A R=f t ² 10. Ceiling Types a. Under Attic (Vented)R=30.0 684.00 ft² f t ² R=b. N/A c. N/A R = f t ² 11. Ducts a. Sup: Attic, Ret: Attic, AH: GREAT ROOM 12. Cooling systems 13. Heating systems 14. Hot water systems a. Electric Cap: 50 gallons b. Conservation features None d. N/A R=f t ² Area Weighted Average Overhang Depth:2.000 ft. Area Weighted Average SHGC:0.250 Description Area Insulation Area Insulation Area Insulation Area 15. Credits None - (Bedrms In Addition) 2(0) (57.0 sqft.) (912.0 sqft.) (684.0 sqft.) (684.0 sqft.) Conditioned floor area below grade (ft²) 0 a. Central Unit a. Electric Strip Heat k B t u / h r 22.0 SEER:13.00 Efficiency k B t u / h r Efficiency 17.0 COP:1.00 f t ² R 6 105 EF: 0.950 Glass/Floor Area: 0.083 Total Proposed Modified Loads: Total Baseline Loads: 25.93 26.31 PASS I hereby certify that the plans and specifications covered by this calculation are in compliance with the Florida Energy Code. PREPARED BY: DATE: I hereby certify that this building, as designed, is in compliance with the Florida Energy Code. OWNER/AGENT: DATE: BUILDING OFFICIAL: DATE: Review of the plans and specifications covered by this calculation indicates compliance with the Florida Energy Code. Before construction is completed this building will be inspected for compliance with Section 553.908 Florida Statutes. - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory-sealed in accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 5.00 ACH50 (R402.4.1.2). FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method FORM R405-2017 4-10-2020 PROJECT Title: Owner Name: # of Units: Builder Name: Permit Office: Jurisdiction: ST. LUCIE COUNTY ST. LUCIE COUNTY 1 RICHARD & VICKEY WALKE RICHARD AND VICKEY WAL Family Type: New/Existing: Bedrooms: Conditioned Area: Total Stories: Worst Case: Rotate Angle: 0 No 1 684 2 Addition Single-family Address Type: Lot # Block/Subdivision: PlatBook: Street: County: City, State, Zip: FL , FT. PIERCE , St. Lucie 2214 N. 45tH STREET Street Address Comment: Building Type: User Cross Ventilation: No Whole House Fan: No TMY Site Design Temp Int Design Temp Heating Design Daily Temp Design Location 2.5 %97.5 % Degree Days Moisture RangeWinter Summer CLIMATE 90 70 75 299 62 Low39FL_VERO_BEACH_MUNIFL, Fort Pierce______ Number Name Area Volume BLOCKS 1 Entire House 684 5472 Number Name Area Volume SPACES Kitchen Occupants Bedrooms Cooled HeatedInfil ID Finished 1 LAUNDRY 84 672 No 0 Yes Yes1 Yes 2 KITCHEN 120 960 Yes 0 Yes Yes1 Yes 3 BATH 40 320 No 0 Yes Yes1 Yes 4 BEDROOM 2 123 984 No 1 1 Yes Yes1 Yes 5 BEDROOM 1 129 1032 No 1 1 Yes Yes1 Yes 6 GREAT ROOM 188 1504 No 2 Yes Yes1 Yes # Floor Type Area Tile Wood Carpet FLOORS Perimeter R-Value Joist R-ValueSpace Perimeter 1 84 ft² 0 1 0______ Slab-On-Grade Edge Insulation - - - -026 ft LAUNDRY 2 120 ft² 0 1 0______ Slab-On-Grade Edge Insulation - - - -012 ft KITCHEN 3 40 ft² 0 1 0______ Slab-On-Grade Edge Insulation - - - -05 ft BATH 4 123 ft² 0 1 0______ Slab-On-Grade Edge Insulation - - - -022 ft BEDROOM 2 5 129 ft² 0 1 0______ Slab-On-Grade Edge Insulation - - - -024 ft BEDROOM 1 6 188 ft² 0 1 0______ Slab-On-Grade Edge Insulation - - - -025 ft GREAT ROOM 4/10/2020 8:54 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 2 of 5 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT # Type Materials Color Absor. Roof Solar Deck Insul. Pitch ROOF Tested Roof Area Gable Area Emitt Tested EmittSA (deg) Rad Barr 1 Hip Composition shingles 721 ft² Medium 0.5 0 18.4______ No0 ft² 0.9 NoN ATTIC # Type Ventilation Area RBS IRCCVent Ratio (1 in) ______ 1 Full attic Vented 684 ft² N N150 # Ceiling Type R-Value Area Framing Frac Truss Type CEILING Space Ins Type 1 Under Attic (Vented) 30 84 ft² 0.1 Wood______ LAUNDRY Blown 2 Under Attic (Vented) 30 120 ft² 0.1 Wood______ KITCHEN Blown 3 Under Attic (Vented) 30 40 ft² 0.1 Wood______ BATH Blown 4 Under Attic (Vented) 30 123 ft² 0.1 Wood______ BEDROOM 2 Blown 5 Under Attic (Vented) 30 129 ft² 0.1 Wood______ BEDROOM 1 Blown 6 Under Attic (Vented) 30 188 ft² 0.1 Wood______ GREAT ROOM Blown WALLS # Wall Type R-Value Area Adjacent Framing Solar Ornt Fraction Absor. HeightWidth Ft In Ft InTo Cavity Sheathing R-ValueSpace Grade% Below 1 4.1 0LAUNDRY 00012 8N Concrete Block - Ext Insul 0.60Exterior 96.0 ft² ____ 2 4.1 0LAUNDRY 0007 8E Concrete Block - Ext Insul 0.60Exterior 56.0 ft² ____ 3 4.1 0LAUNDRY 0007 8W Concrete Block - Ext Insul 0.60Exterior 56.0 ft² ____ 4 4.1 0KITCHEN 00010 8E Concrete Block - Ext Insul 0.60Exterior 80.0 ft² ____ 5 4.1 0KITCHEN 0002 8W Concrete Block - Ext Insul 0.60Exterior 16.0 ft² ____ 6 4.1 0BATH 0005 8E Concrete Block - Ext Insul 0.60Exterior 40.0 ft² ____ 7 4.1 0BEDROOM 2 00011 8E Concrete Block - Ext Insul 0.60Exterior 88.0 ft² ____ 8 4.1 0BEDROOM 2 00011 8S Concrete Block - Ext Insul 0.60Exterior 88.0 ft² ____ 9 4.1 0BEDROOM 1 00013 8S Concrete Block - Ext Insul 0.60Exterior 104.0 ft² ____ 10 4.1 0BEDROOM 1 00011 8W Concrete Block - Ext Insul 0.60Exterior 88.0 ft² ____ 11 4.1 0GREAT ROO 00012 8N Concrete Block - Ext Insul 0.60Exterior 96.0 ft² ____ 12 4.1 0GREAT ROO 00013 8W Concrete Block - Ext Insul 0.60Exterior 104.0 ft² ____ # Door Type U-Value AreaStorms DOORS Ornt Space Width Ft In Ft In Height 1 Insulated .39 20 ft² None______ N LAUNDRY 863 2 Insulated .39 20 ft² None______ W GREAT ROO 863 4/10/2020 8:54 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 3 of 5 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT # Ornt Panes NFRC U-Factor SHGC Area Depth Separation Int ShadeFrame Screening WINDOWS Overhang Orientation shown is the entered, Proposed orientation. Wall ID Imp 1 E Low-E Single 0.65 0.25 12.0 ft² 2 ft 0 in 1 ft 4 in NoneMetal None______ Yes4 N 2 E Low-E Single 0.65 0.25 15.0 ft² 2 ft 0 in 1 ft 4 in NoneMetal None______ Yes7 N 3 W Low-E Single 0.65 0.25 15.0 ft² 2 ft 0 in 1 ft 4 in NoneMetal None______ Yes10 N 4 W Low-E Single 0.65 0.25 15.0 ft² 2 ft 0 in 1 ft 4 in NoneMetal None______ Yes12 N Method CFM 50 ACH 50ELASLAScope INFILTRATION ACHEqLA# 456 525.03.000254Wholehouse .088147.08Proposed ACH(50)1 HEATING SYSTEM # System Type Efficiency Capacity DuctsSubtype BlockSpeed 1 Electric Strip Heat/None (Basel COP:1 17 kBtu/hr ______ sys#1None 1 # System Type Efficiency Capacity Air Flow SHR COOLING SYSTEM DuctsSubtype BlockSubtype 1 Central Unit/None (Baseline as SEER: 13 22 kBtu/hr c f m 0.7______ sys#1Split 1 Single # System Type EF Cap Use SetPnt Conservation HOT WATER SYSTEM SubType Location 1 Electric 0.95 50 gal 60.9 gal 120 deg None______ None LAUNDRY FSEC Company Name System Model # Collector Model # Collector SOLAR HOT WATER SYSTEM Storage FEFCert # Area Volume None None f t ² ______ # Location R-Value Area Location Area ---- Supply ---- ---- Return ---- Leakage Type Handler CFM 25Air QN RLF DUCTS Heat Cool HVAC # TOT OUT CFM25 1 Attic 6 105 ft² Attic 65 ft² Default Leakage GREAT RO (Default) c______ 1 1 (Default) c 4/10/2020 8:54 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 4 of 5 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT TEMPERATURES Programable Thermostat: N Ceiling Fans: Cooling [ ] Jan [ ] Feb [ ] Mar [ ] Apr [ ] May [X] Jul [X] Aug [X] Sep [ ] Oct [ ] Nov [ ] Dec [ ] Dec[X] Dec[X] Nov[X] Nov[ ] Oct[X] Oct[ ] Sep[ ] Sep[ ] Aug[ ] Aug[ ] Jul[ ] Jul[ ] Jun[ ] Jun[X] Jun[ ] May[ ] May[ ] Apr[X] Apr[X] Mar[X] Mar[X] Feb[ ] Feb[X] Jan[ ] JanHeatingVenting Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AMPM 7880 7880 7880 7880 7878 7878 7878 7878 8078 8078 8078 8078 Cooling (WEH) AMPM 7880 7880 7880 7880 7878 7878 7878 7878 8078 8078 8078 8078 Heating (WD) AMPM 6568 6568 6568 6568 6568 6568 6568 6868 6868 6868 6868 6868 Heating (WEH) AMPM 6568 6568 6568 6568 6568 6568 6568 6868 6868 6868 6868 6868 MASS Mass Type Area Thickness Furniture Fraction Space Default(8 lbs/sq.ft. 0 ft² 0 ft 0.3 LAUNDRY Default(8 lbs/sq.ft. f t ² f t 0.3 KITCHEN Default(8 lbs/sq.ft. f t ² f t 0.3 BATH Default(8 lbs/sq.ft. f t ² f t 0.3 BEDROOM 2 Default(8 lbs/sq.ft. f t ² f t 0.3 BEDROOM 1 Default(8 lbs/sq.ft. f t ² f t 0.3 GREAT ROOM 4/10/2020 8:54 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 5 of 5 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT