Loading...
HomeMy WebLinkAboutCertificate for Design Load CompliancePlanning & Development Services Department Building & Code Regulations Division 2300 Virginia Avenue, Fort Pierce, FL 34982 — (772) 462-1553 Certification for Design Load Compliance Project Name: Renovation Project Address: 2214 N 45th Street, Fort Pierce FL Permit #: 2003-0391 Occupancy Type: SFR Construction Type: 213 INSTRUCTIONS FOR USE: • This certification must be completed, signed, and sealed by the design professional of record. • Submit (2) copies for residential, (3) copies for commercial with all permit applications involving the following: o New Residences (single or multi -family) o Residential Addition o Any accessory structure requiring a building permit o Any non-residential structure. * Note: Form not required for interior renovations provided that no exterior structural elements are affected and certain minor building permits at the discretion of the local building official. Contact the # above for questions. DESIGN PARAMETERS AND ASSUMPTIONS USED: (complete all that apply) 1. DESIGN CODE: Florida FBC Code Fifth Edition with 20 17 Supplements using ASCE 7-10 2. Structure Designed as (check one): X Enclosed Partially Enclosed Open 3. Risk Category: _I X II III _ IV Exposure Category: B X C D 4. Design Wind Velocity 139 mph X ASD LRFD End Zone Width: 28 ft 5. Mean Roof Height 15 ft Roof Pitch: 3 :12 Parapet: 0 ft 6. Components & Cladding Design Pressures Used: (PSF, based on 10sgft @ 15'MRH, clearly label on all plan openings): Zone 1: Zone 2: Zone 3: X Zone 4: Zone 5: Garage: 7. Design Loads: Floor: 30 PSF Roof/Dead: 30 PSF Roof/Live: 30 Balcony: NA PSF Dock: NA PSF Deck: NA PSF Stairs: NA PSF Fence: NA PSF Railings: NA PSF 8. Were Shear Walls Considered For Structure? Yes x Not Applicable Explain Why Not: EXISTING STRUCTURE 9. Is A Continuous Load Path Provided? X Yes Not Applicable Explain Why Not: 10. Design Soil Bearing Pressure: EXIST. PSF Soil Test Reports Submitted? NO Yes DESIGN PROFESSIONAL CERTIFICATION STATEMENT: I certify that, to the best of my knowledge and belief, the attached plans & specifications have been designed to comply with the applicable structural portions of the building codes currently adopted and enforced by St. Lucie County. I also certify that structural elements depicted on these plans provide adequate resistance to the design forces specified: \\\\�0IIIIIIEIIIr!/// Wayne Gandy ���� Q� N •qN0 i Print Name Cert # & Co. Cert Auth. 0 �1510 E Colonial Drive Ste 230 N Signature, 1iatgr id al * 5I S TE i5ompany Name & Address Revised 07/25j