Loading...
HomeMy WebLinkAboutSuction Outlet Safety Compliance Data SheetAPSP/ANSI-7 Suction Outlet Safety Compliance Data Sheet (One sheet for each drain or set of drains in the systeml Job Name: Address: 2365. I I�IhS!'r' �idlati�A°J111itll�i"ii�nh F THIS DATA IS FOR THE: POOL ! AUXILIARY (Spa, Feature(s), etc,) SUCTION OUTLET(S) Are there drains: yes no 1,ms (if no, go to truck & return pipe sl Single unblockable ___)`__ Two or. more Drain make & model: I�" �1' Listed cover flow rate: ZF)U gpm SYSTEM FLOW RATE System flow rate: T IN—gpm Method of determining system flow: Maximum flow from the pump curve ---�—Total dynamic head calculation (attach calculation sheet) Simplified total dynamic head (attach pipe length +filter PUMP SELECTION Pump make& model: 1 �^�U�`^� / (attach pump performance curve, indicating flow as calculated above) SUCTION PIPE SIZE Branch piping size _� @ fps Inch @ 6 fps or lower Z Inch 8 Truck line size . MAY 2020 RETURN PIPE e 0 Pipe size Z L inch @ 10 fps i i of ReM and Seal BEY _ KOVNcc7Z�/i ���ErdSF•�P ��/ i No.16668 STATE OF ��\ cCOR10P GN S/ONAC Wrall1\ 0 EIYSID ENGINEERING, INC. PROFESSIONAL CIVIL ENGINEERS ENGINEERING & CONSTRUCTION MGT. SIDNEY ICOVNER, E.E. j "No Job Too Small" (561)386-4385 (56I) 352-508..6 ' (561) 622-6820 Fax. ' 139 Isle Verde Way elsidmgQa emncasLnet 1 Palm Beach Gardens, FL 33418 'TD y = 7 S-T P 3-1p v5f e.. 311so p_paa 6.0 1p IL Z bo qo. - ��� Ly 8. FA&' . 2L fdv� 6, S lI'ML cc a O m a E W L) �i m COm zW cc W J 0 W : E I o T � N 7 N a c�1 J Ica O 4 N C 2 8 � , Ima\\\\\\\\\1�11a��ti / m o le 6 :c ;-� as % ems'••: - a ccl tll c � O ti d CX to 71 o� i a no•ou IV r. it AOR- t ,a �SUPERFLO® M j j' Hi6H PERFORMANCE PUMPS (CONT'D) iz AW. 30 10 90 25 80 70 o « 20 L Lau 3�", 60 zo _j 15. 0 50 f- d m 10 u.40 30 20 5 10 0 Dimensions and Performance 0- 10 20 30 40 5-0 60770 80 90 100 110 120 130 U.S. Gallons per Minute 0. 5 10 15 .20 25 30 r' Cubic Meters per Hour A -varying length: 1/2 & 3/4 & iHP = 24.64- 1.5HP=24.96' 2HP=25.B9• 25NP. 25.89" ,.A IF See page 513 for replacement parts. un. 1. zviq-I I:I 0 PENTAIR r � I Y 1. r :I 11 i erIzon lllreIess, macon SUPERFLO° HiGH PERFORMANCE PUMPS IIII�- arl Niahlic S!?^ a SuperFlo pump by Pentair Aquatic Systems is a direct replacement for the Hayward' Super Pumps' • Extremely quiet operation Appliance W-doc, • Unionized fittings included 11-1/2 in. internal slip and Efficiency 2 in. external slip) Database • Gam and Ramp Lid a Heavy-duty, high service factor 56 square flange motor a Integralvolute and pot reduce hydraulic noise SuperFlo Pump to bathe best choice for a variety of ingroind po6ls. The SuperFlo pump The SuperFlo° pumps are specifically designed thick wailed body parts, a heavy-duty 56 square flange motor, and highly engineered hydraulics. The SuperFlo features silent running capability and small footprint allow it to easily drop into a compact equipment pad. pumps' Ordering Information Full Load HP SF PrimaryLstings and PartSize Carton Curve SFHP INPTI w1.11-hs.l Key Product Modal Voltage Amps Cerliflcabio094 348021 SF1,11.1/2FE 1151208-230 ILZA.S-6.4 t/2 ISO 0.95 UL',NSF',APSP' 15 in. x l.Sln. 38 E 34B022 SF•111-2/4FE 115/208.230 B.B/4.5-4.4 3/4 125 .93 UL'.NSF' 131NXt5in. 38 F 0 348023 SF-NI-1AE 115@08-230 iL2/6A-5.6 1 1.25 1.25 UL',NSF'. UIN a1.5 in. 38 34Bp24 SF-N7.1-1/2AE 1151208-230 14.0f19-24 1-1/2 1-10 t 1.5 ix151n. 40 H 1.65 VL1; NSFa 348025 Sr-2AE 208-230 9.6-8.8 2 1.10 2.20 UL.NSF 15 ia.N x 1.5 to. 46 I 340076 SFN1-2-112AE 206•290 11.0-10.2 2-1/2 1.04 210 ULI,NSF' 15in. x 1.5iry 54 J L 0.95. UL',NSF'.APSP' 151ax1.5in. 38 E 340036 SF-N1412F 115/27e 10.815.4 111 1.95 340037 6F117-314A 1151230 10.8/5.4 3/4 1.25 0.72 UL%NSF1 1.51a x1.51n. 38 F 34003H SF-N14A 115/230 14.217.1 1 125 1.25 OL',NSF' 1.5 in. x is in. 38 6 340039SF-MI.1-112A 115/23a 16.0/8.0 1.6 LID 1.65 UL',NSF' iSin.xl.5in. 40 N d 340040 SF•NI-2A 115/230 22.4ry1.2 2 1.t0 220 UL'.NSF' Lsin.xt.sln. 48 I 340041 SF+41-2-1/7A 230 11.5 2-1R 1.94 2-60 UL-.NSF- 1.5 in-x1.5jq 54 J -- • r 341111 5F-02-314A 115 14.6/4.7 314 1.67 1.25 UL I.NSF', APSP' 1.5 IN x 1.5 m. 39 A, F 230 6.0/2-3 1 1.25 1.25 UL',NSF',ApsP' 1.5 in. x 1.5 In. 39 B,e 340042 SFN2-IA 7.813.0 14/2 LID H 1.65 UL', NSF, APSP' 1.5in.xl.Sin. me C.- 140013 SFN2-1-1/2A 230 011 220 UL!,NSF'.APSP' 1.S In. x 1.5 IN 49 D,1 340044 SF-N2.2A 230 lotu:t5 2 1 ' 340096 SF-NI.1/2 2401126 25/15.0 112 1.1 0.55 UL' 1.51n.11.5in. 38 340094 5FN1-1-3/4 2401120 2S/15.0 3A 1.1 1.5in.x1.5in. 40 0.82 UL - 340095 SF-N1.1 2601120 - 6.9/13•8 1 1,1 1.10 UL I.5 in. x 1.5in. 38 340096 SF-N1•ii/2 240 72 1412 .1.1 1.69 UL 1.5 in.x1,5in. 40 9A 2 1.1 2.20 UL' 1.5in.x1.5in. 48'. 349097 SF-NI-2 240 rfflKqztlr 350157 Union Kit-1.1/2in.Inlereai SUpx2in. ExlernalSiip rincludes2 unions as plcluredatiml .. 'UL'indiCales that bears UL mark signifying evaluation to V,S. ' 'APSP' Pump has been evaluated to ANSI/APSPACC-15 and California Residential PoolFnUation pump Standards UL10B1 for Parmenenlly Connected Swimming Pool and5pa Title 20 and is certified to use an Pumps and to Canadian Standards CAN/CSA C22.2 No. 108.01 Liquid Systems. Pumps For Swimming Pants Only (Enclosure 31- ' Product may have been evaluated to other slate and local regulatory standards. Listing slalus may Change. Always connrm status with I 'NSF indicates that pump bears a NSF mark signifying evaluation to Centrifugal Pumps For Swimming appropriate agency if in douhL NSF Standard 50 For 5elf•Priming - - Pump° are registered indemarks of Hayward PoOtsOnly. - Hayward and Super Industries, Inc. Select g j Naprey^ %I 17 % • _ Pump Performance Curves Total Head Vs. Flow @ Factory Set Speeds 60 HZ Single Phase Test Voltage 35 I 30 3 3s ` x 6 a ° 30 `o s r•� 15 10 5 0 20 40 60 80 100 120 140 160 U.S. Gallons per minute s 10 15 20 z 30 35 Cubic Meters per hour The Media Agrees: IntelliFlo is Big News From LA. to NewYork, Phoenix to Fort Lauderdale, reporters studies where the savings estimates have become savings are giving IntelliFlo pumps high visibility and high marks. To date, reality. That's not only big news, but good news for any pool hundreds of stories have appeared in newspapers and newscasts owner who wants big savings and is currently overpaying due around the country. Many reports include pool owner case to the fundamental inefficiency of a traditional pool pump. oa�yaawe/s�asv�ve cregister KOLE Start Sa.VI ng Today! p . Call 1.800.374.4700 for more NEWYORKOBSERVER A