HomeMy WebLinkAboutNOA; ICP Adhesives Polyset AH-160File Copy
MIAMIM CONTROL
MICOUNTY
�� PRODUCT CONTROLL SECTION
11805 SW 26 Street, Room 208
DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) Miami, Florida 33175-2474
BOARD AND CODE ADMINISTRATION DIVISION T (786)315-2590 F (786) 315-2599
NOTICE OF ACCEPTANCE (NOA) m .miamldade.eov/economy
ICP Adhesives and Sealants, Inc.
12505 NW 44" Street
Coral Springs, FL. 33065
SCOPE:
This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The
documentation submitted has been reviewed and accepted by Miami -Dade County RER -Product Control Section to be
used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ).
This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section
(In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product
or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the
manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use
of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is
determined by Miami -Dade County Product Control Section that this product or material fails to meet the requirements
of the applicable building code.
This product is approved as described herein, and has been designed to comply with the Florida Building Code
including the High Velocity Hurricane Zone of the Florida Building Code.
DESCRIPTION: ICP Adhesives Polysee AH-160
LABELING: Each unit shall bear a permanent label with the manufacturers name or logo, city, state and following
statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change
in the applicable building code negatively affecting the performance of this product.
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the
materials, use, and/or manufaclure of the product or process. Misuse of this NOA as an endorsement of any product, for
sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of
this NOA shall be cause for termination and removal of NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the
expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done
in its entirety.
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and
shall be available for inspection at the job site at the request of the Building Official.
This NOA renews NOA 16-0315.01 and consists of pages 1 through 11.
The submitted documentation was reviewed by Alex Tigem.
NOA No.: 17-0322.03
Expiration Date: 05/10/22
Approval Date: 04/27/17
Page 1 of 11
RECEIVED
SUN 01 2020
Permitting Department
St. Lucie County
ROOFING COMPONENT APPROVAL:
Category: Roofing
Sub Category: Roof file adhesive
Materials: Polyurethane
SCOPE:
This approves ICP Adhesives Polyset® AH-160 as manufactured by ICP Adhesives and Sealants, Inc. as described
in this Notice of Acceptance. For the locations where the design pressure requirements, as determined by applicable
building code, do not exceed the design pressure values obtained by calculations in compliance with Roofing
Application Standard RAS 127. For use with approved flat, low, and high profile roof tile systems using ICP
Adhesives Polyset® AH-160.
PRODUCTS MANUFACTURED BY APPLICANT:
Product Dimensions Test
Specifications
ICP Adhesives N/A TAS 101
Polyset®AH-160
ICP Adhesives Foam N/A
Dispenser RTF1000
ICP Adhesives ProPacO N/A
30 & 100
Product Description
Two component polyurethane foam adhesive
Dispensing Equipment
Dispensing Equipment
PRODUCTS MANUFACTURED BY OTHERS:
Any Miami -Dade County Product Control Accepted Roof Tile Assembly having a current NOA which list attachment
resistance values with the use of ICP Adhesives Polyset® AH-160 roof file adhesive.
MANUFACTURING LOCATION:
Tomball, TX.
PHYSICAL PROPERTIES:
Prove
Test
Density
ASTM D 1622
Compressive Strength
ASTM D 1621
Tensile Strength
ASTM D 1623
Water Absorption
ASTM D 2127
Moisture Vapor Transmission
ASTM E 96
Dimensional Stability
ASTM D 2126
Closed Cell Content ASTM D 2856
Results
1.6 lbs./ft'
18 PSI Parallel to rise
12 PSI Perpendicular to rise
28 PSI Parallel to rise
0.08 Lbs./Ftz
3.1 Perm / Inch
+0.07% Volume Change @ 400 F., 2 weeks
+6.0% Volume Change @1580F., 100% Humidity, 2
weeks
86%
Note: The physical properties listed above are presented as typical average values as determined by
accepted ASTM test methods and are subject to normal manufacturing variation.
NOA No.: 17-0322.03
Expiration Date: 05/10/22
Approval Date: 04/27/17
Page 2 of 11
.. �
..! '_
i! .(
EVIDENCE SUBMITTED:
Test Aeencv
Test Identifier
Test Name/Report
Date
Center for Applied Engineering
994-060
TAS 101
04/08/94
257818-IPA
TAS 101
12/16/96
25-7438-3
SSTD 11-93
10/25/95
25-7438-4
25-7438-7
SSTD 11-93
11/02/95
25-7492
SSTD 11-93
12/12/95
Miles Laboratories
NB-589-631
ASTM D 1623
02/01/94
Polymers Division
Ramtech Laboratories, Inc.
9637-92
ASTM E 108
04/30/93
Southwest Research Institute
01-6743-011
ASTM E 108
11/16/94
O1-6739-062b[I]
ASTM E84
01/16/95
Trinity Engineering
7050.02.96-1
TAS 114
03/14/96
P36700.04.12
ASTM D 1623
04/18/12
P39740.02.12
TAS 101
02/21/12
TAS 123
Celotex Corp. Testing Services 528454-2-1 TAS 101 10/23/98
528454-9-1
528454-10-1
520109-1 TAS 101 12/28/98
520109-2
520109-3
520109-6
520109-7
520191-1 TAS 101 03/02/99
520109-2-1
LIMITATIONS:
1. Fire classification is not part of this acceptance. Refer to the Prepared Roof Tile Assembly for fire rating.
2. ICP Adhesives Polyset® AH-160 shall solely be used with flat, low, & high tile profiles.
3. Minimum underlayment shall be in compliance with the Roofing Application Standard RAS 120.
4. Roof Tile manufactures acquiring acceptance for the use of ICP Adhesives Polyse& AH-160 roof tile adhesive
with their tile assemblies shall test in accordance with TAS 101.
5. All products fisted herein shall have a quality assurance audit in accordance with the Florida Building Code and
Rule 61 G20-3 of the Florida Administrative Code.
NOA No.: 17-0322.03
Expiration Date: 05/10/22
Approval Date: 04/27/17
Page 3 of 11
INSTALLATION:
1. ICP Adhesives Polyset® AH-160 maybe used with any roof tile assembly having a current NOA that lists
attachment resistance values with the use of ICP Adhesives Polyset® AH-160.
2. ICP Adhesives Polyset® AH-160 shall be applied in compliance with the Component Application section and the
corresponding Placement Details noted herein. The roof tile assembly's adhesive attachment with the use of ICP
Adhesives Polyset® AH-160 shall provide sufficient attachment resistance to meet or exceed the resistance value
determined in compliance with Miami -Dade County Roofing Application Standards RAS 127. The adhesive
attachment data is noted in the roof tile assembly NOA.
3. ICP Adhesives Polyset® AH-160 and its components shall be installed in accordance with Roofing Application
Standard RAS 120, and ICP Adhesives and Sealants, Inc.'s Operating Instruction and Maintenance Booklet.
4. Installation must be by a Factory Trained'Qualified Applicator approved and licensed by ICP Adhesives and
Sealants, Inc. ICP Adhesives and Sealants, Inc. shall supply a list of approved applicators to the authority having
jurisdiction.
S. Calibration of the ICP Adhesives Foam Dispenser RTF 1000 dispensing equipment is required before application
of any adhesive. The mix ratio between the "A" component and the "B" component shall be maintained between
1.0-1.15 (A): 1.0 (B).
6. ICP Adhesives Polyset® AH-160 shall be applied with ICP Adhesives Foam Dispenser RTF1000 or ICP
Adhesives ProPack® 30 & 100 dispensing equipment only.
7. ICP Adhesives Polyset® AH-160 shall not be exposed permanently to sunlight.
S. Tiles must be adhered in freshly applied adhesive, Tile must be set within 1 to 2 minutes after ICP Adhesives
Polyset® AH-160 has been dispensed.
9. ICP Adhesives Polyset® AH-160 placement and minimum patty weight shall be in accordance with the
'Placement Details' herein. Each generic tile profile requires the specific placement noted herein.
MUIMIDADE COUNTY NOA No.: 17-0322.03
Expiration Date: 05/10/22
Approval Date: 04/27/17
Page 4 of 11
Table 1: Adhesive Placement For Each Generic Tile Profile
Tile Profile
Placement Detail
Mrmmum Paddy Contact
Minimum Paddy Gram
Area
Weight
Eave Course - Flat, Low, High
All Eave Course
17-23 sq. inches
45-65
Profiles
Flat, Low, High Profiles
#1
17-23 sq. inches
45-65
Flat Profile
#2
10-12 sq. inches
30
Low Profile
#2
12-14 sq. inches
30
High Profile
#2
17-19 sq. inches
30
Flat, Low, High Profiles
#3
Two Paddys: 8-9 sq. inches at
12 grams per paddy
head of tile 9-11 sq. inches at
overlap
Two -Piece Barrel (Cap Tile)
Two Piece
2 Beads (1 each longitudinal
17 grams per bead
edge) 20-25 sq. inches each
bead
Two Piece Barrel (Pan Tile)
Two Piece
65-70 sq. inches
34 grams under pan
LABELING:
All approved products listed herein shall be labeled and shall bear the imprint or identifiable marldng of the
manufacturer's name or logo and following statement: "Miami -Dade County Product Control Approved" or the Miami -
Dade County Product Control Seal as shown below.
BUILDING PERMIT' REQUIREMENTS:
As required by the Building Official or applicable building code in order to properly evaluate the installation of this
system.
NOA No.: 17-0322.03
Expiration Date: 05/10/22
Approval Date: 04/27/17
Page 5 of 11
ADHESIVE PLACEMENT DETAIL # 1
optional
F.sd.
p•ddyl6.n.nh7ad
aa[.na
opl6on.l
1p La'
Flat/Low Profile Tile
1. Starting at the eave course, apply a minimum 2"
(50.8 mm) x 10" (254 am) x 1" (25.4 mm) foam
paddy onto the underlayment positioned as shown,
under the strengthening rib closest to the overlock
of the tile being set.
2. Continue in same manner. Insure approximately 17
(109.7 cmZ) — 23 (148.4 cmZ) square inch adhesive
contact with the underside of the tile.
Medium Profile / Double Pan Tile
1. Starting at the eave course, apply a minimum 2"
(50.8 mm) x 10" (254 nun) x 1" (25.4 nun) foam
paddy onto the underlayment positioned as shown
under the pan portion of the tile closest to the
overlock of the tile being set.
2. Continue in same manner. Insure approximately 17
(109.7 cmZ) — 23 (148.4 cmZ) square inch adhesive
contact with the underside of the tile.
High Profile / Single Pan Tile
1. Starting at the eave course, apply a minimum 2"
(50.8 nun) x 10" (254 mm) x 1" (25.4 nun) foam
paddy onto the underlayment positioned as shown
under the pan portion of the tile closest to the
overlock of the tile being set.
2. Continue in same manner. Insure approximately 17
(109.7 cmZ) — 23 (148.4 cmZ) square inch adhesive
contact with the underside of the tile.
NOA No.: 17-0322.03
Expiration Date: 05/10/22
Approval Date: 04/27/17
Page 6 of 11
ADHESIVE PLACEMENT DETAIL ## 2
r In.
Nod.
MIAMFDAOECOUNTY
Flat/Low Profile Tile
Starting at the eave course, apply a minimum 2" (50.8
mm) x 10" (254 nun) x 1" (25.4 mm) foam paddy
onto the underlayment positioned as shown under the
strengthening rib of the tile closest to the overlock of
the tile being set. Insure approximately 17 (109.7 cm2)
— 23 (148.4 cm2) square inch adhesive contact with the
underside of the tile.
2. At the second course, apply a minimum 2" (50.8mm)
x 7" (177.8 mm) x 1" (25.4 mm) foam paddy onto the
underlayment positioned as shown under the
strengthening rib closest to the overlock of the tile
being set.
3. Continue in same manner. Insure approximately 10"
(64.5 cm2) - 12 (77.4 cm2) square inch adhesive
contact with the underside of the tile.
Medium Profile / Double Pan Tile
Starting at the cave course, apply a minimum 2" (50.8
mm) x 10" (254 mm) x 1" (25.4 ram) foam paddy
onto the underlayment positioned as shown under the
pan portion of the tile closest to the overlock of the
tile being set. Insure approximately 17 (109.7 cm2) —
23 (148.4 cm2) square inch adhesive contact with the
underside of the tile.
2. At the second course, apply a minimum 2" (50.8mm)
x 7" (177.8 mm) x l" (25.4 mm) foam paddy onto the
underlayment positioned as shown under the pan
portion of the tile closest to the overlock of the tile
being set.
3. Continue in same manner. Insure approximately 12"
(77.4 cm2) -14 (90.3 cm2) square inch adhesive
contact with the underside of the tile.
(Instructions continued on next page)
NOA No.: 17-0322.03
Expiration Date: 05/10/22
Approval Date: 04/27/17
Page 7 of 11
ADHESIVE PLACEMENT DETAIL # 3
RaVWwProfileTlle
Fascia
Medium ProflleTile
On the cave course only, apply a minimum 2" (50.8
min) x 10" (254 min) x 1" (25.4 nun) foam paddy
onto the underlayment positioned as shown, under
the strengthening rib for flat tile or under the pan
portion of the tile for low or high profile tile closest
to the overlock of the tile being set. Leave
approximately 4" (101.6 min) up from the cave
edge free of foam to prevent the expanded adhesive
from blocking the weep holes. Insure
approximately 17-23 in' (109.7-148.4 cm') of
adhesive contact with the underside of the tile
2. Apply a 4" (101.6 min) x 4" (101.6 min) x 1" (25.4
min) foam paddy onto the underlayment just below
the second course line positioned foam paddy
under the strengthening rib for flat file, or under the
pan portion of the tile, closest to the underlock for
the second course file to be installed. Insure
approximately 8-9 W (51.6-58.1 crn) of adhesive
contact with the underside of the tile.
(Instructions continued on next page)
NOA No.: 17-0322.03
Expiration Date: 05/10/22
Approval Date: 04/27/17
Page 9 of 11
ADHESIVE PLACEMENT DETAIL # 2 (CONTINUED)
odya
High Profile / Single Pan Tile
Starting at the eave course, apply a minimum 2" (50.8
mm) x 10" (254 mm) x 1" (25.4 nun) foam paddy
onto the underlayment positioned as shown under the
pan portion of the file closest to the overlock of the
tile being set. Insure approximately 17 (109.7 cm� —
23 (148.4 cm2) square inch adhesive contact with the
underside of the tile.
2. At the second course, apply a minimum 2" (50.8mm)
x 7" (177.8 mm) x 1" (25.4 mm) foam paddy onto the
underlayment positioned as shown under the pan
portion of the tile closest to the overlock of the tile
being set.
3. Continue in same manner. Insure approximately 17"
(109.7 cm') -19 (122.6 cm) square inch adhesive
contact with the underside of the tile.
NOA No.: 17-0322.03
Expiration Date: 05/10/22
Approval Date: 04/27/17
Page of 11
In.
ADHESIVE PLACEl1TENT DETAIL # 3
` <2x4m6
a toin '.
RatAow ProfileTlle
Medium ProflleTlle
Fascia
1. On the eave course only, apply a minimum 2" (50.8
mm) x 10" (254 mm) x 1" (25.4 mm) foam paddy
onto the underlayment positioned as shown, under
the strengthening rib for flat tile or under the pan
portion of the the for low or high profile tile closest
to the overlock of the tile being set. Leave
approximately 4" (101.6 mm) up from the eave
edge free of foam to prevent the expanded adhesive
from blocking the weep holes. Insure
approximately 17-23 in' (109.7-148.4 cm) of
adhesive contact with the underside of the tile
2. Apply a 4" (101.6 mm) x 4" (101.6 mm) x 1" (25.4
mm) foam paddy onto the underlayment just below
the second course line positioned foam paddy
under the strengthening rib for flat tile, or under the
pan portion of the tile, closest to the underlock for
the second course tile to be installed. Insure
approximately 8-9 in' (51.6-58.1 cmz) of adhesive
contact with the underside of the tile.
(instructions continued on next page)
NOA No.: 17-0322.03
Expiration Date: 05/10/22
Approval Date: 04/27/17
Page 9 of 11
ADHESIVE PLACEMENT DETAIL # 3 (CONTINUED)
High PmflleTlle
3. Also apply a 2" (50.8 mm) x 4" (101.6 mm) x'/"
(19 mm) paddy on top of the eave course tile
surface as shown, on top of the strengthening rib
for flat tile or on top of the pan portion of the tile,
closest to the underlock of the first course of tile.
Install second course of file. Insure approximately
9 (58.1 cm') -11 (71cm2) square inch adhesive
contact with the underside of the tile at the overlap
and 7 (45.2 cm2) - 9 (58.1 cm) square inch
adhesive contact with the underside of the tile at
the head of the tile. Continue in same manner.
NOA No.: 17-0322.03
Expiration Date: 05/10/22
Approval Date: 04/27/17
Page 10 of 11
1) Plate enough adhesive to adders 65
In santa"with the pan tile.
21 Tum coven upside down.Plate adhe
to 1 In. from outside edge of saver tile.
(motershown)
ADHESIVE PLACEMENT DETAIL,
TWO PIECE BARREL
steep
end of Pan and mver tiles are flush at eave line.
Two Piece Barrel - High Profile Tile
MIAM4DADE COUNTY
t i
Two Piece Barrel (Cap and Pan) Tile
Starting at the cave course, apply a minimum 2"
(50.8 mm) x 10" (254 mm) x 1" (25.4 mm) foam
paddy onto the underlayment positioned as
shown under two adjacent pan tiles. Support cave
tiles from rocking until adhesive has a chance to
cure.
2. Continue in same manner bringing two pan
courses up toward the ridge. Insure
approximately 65 (419.4 cm2) — 70 (451.6 cm2)
square inch adhesive contact with the underside
of the pan tile.
3. Tom covers upside down exposing the underside
of the tile. Apply a minimum 1" (25.4 mm) x 10"
(254 nun) bead of adhesive directly on the inner
edge of each side of the cover tile. Leave
approximately 3/4" (19 mm) to 1" (25.4 mm)
from the outside edge of the tile, inward, free of
foam to allow for expansion.
4. Turn cover tile over after foam is applied and
place onto pan tile course. Insure a minimum of
20 (129 cm2) - 25 (161.3 cm2) square inch
contact area on each side of the cover tile to the
pan tile. Continue in same manner. Trim away
any cured exposed foam adhesive. Pointing of
longitudinal edges of the cover tiles are
considered optional.
5. When additional nailing is required, 2" (50.8
mm) x 4" (101.6 mm) milers or the tie wire
system using galvanized, stainless steel, or
copper wire and compatible nails may be used.
END OF THIS ACCEPTANCE
NOA No.: 17-0322.03
Expiration Date: 05/10/22
Approval Date: 04/27/17
Page 11 of 11