HomeMy WebLinkAboutEnvelope Compliance Certificate�( COMcheck Software Version 4.1.1.0
Envelope Compliance Certificate
Project Information
GCMC
Energy Code:
2017 Florida Building Code, Energy Conservation
Project Title:
FSS-7246 FL BUSINESS
Location:
Miami, Florida
Feb 05, 2019
Climate Zone:
1 a
Project Type:
New Construction
APPROVED
Vertical Glazing / Wall Area:
8%
7�.1cka.mGA. 11e
9
Construction Site:
Owner/Agent:
Designer/Contractor.
FIRST STRING SPACE INC
JAMES BRADLEY P.E.
892 EAST RAILROAD AVE.
799 HALLECK CANYON RD.
PEARSON, GA 31642
WHEAT D
Additional Efficiency Package(s)
On -site Renewable Energy
N VV 2 2 2019
Building Area
Floor Area
ST. Lucie County, Perr
1-Office: Nonresidential
654
Envelope Assemblies
Assembly Gross Area Cavity Cont. Proposed Budget U-
or R-Value R-Value U-Factor Facton.r
Perimeter
Roof 1: Attic Roof with Wood Joists, [Bldg. Use 1 - Office] 654 30.0 0.0 0.034 0.027
Floor 1: Woad -Framed, [Bldg. Use 1 - Office] 654 19.0 0.0 0.051 0.066
SOUTH
Exterior Wall 1: Wood -Framed, 16" o.c., [Bldg. Use 1 - Office] 1083 13.0 0.0 0.089 0.064
Window 1: Metal Frame with Thermal Break:Operable, Pert. Specs.: 81 — — 0.450 0.650
Product ID WA, SHGC 0.25, [Bldg. Use 1 - Office] (b)
Door 1: Insulated Metal, Swinging, [Bldg. Use 1 - Office] 40 — — 0.292 0.610
(a) Budget U-factors are used for software baseline calculations ONLY, and are not code requirements.
(b) Fenestration product performance must be certified in accordance with NFRC and requires supporting documentation.
!Envelope PASSES: Design 6% beffer than code
Envelope Compliance Statement "`����tau9lttmnnryp////
Compliance Statement: The proposed envelope design represented in this document is consistent will il3n
specifications, and other calculations submitted with this permit application. The proposed enveloptj�g�
designed to meet the 2017 Florida Building Code, Energy Conservation requirements in COMcheck� n•4Y.`r�Alltd•c�(fi
with any applicable mandatory requirements listed in the Inspection Checklist. � :'
D«usisnm r NO. 16685
James E. Bradley, P.E.
e
NateonTMng Engineer - Sole Proprietorship Signature
799 Halleck Canyon Road 45eeDE13831A8460... .
STATE OF c
Wheatland, WY 82201
2/5/2019
Project Title: FSS-7246 FL BUSINESS Report date: 02/05/19
Data filename: Untitled.cck Page 1 of 20
C✓
COMcheck Software Version 4.1.1.0
Mechanical Compliance Certificate
Project Information
Energy Code:
Project Title:
Location:
Climate Zone:
Project Type:
Construction Site:
Additional Efficiency Package(s)
On -site Renewable Energy
Mechanical Systems List
Quantity System Type & Description
2017 Florida Building Code, Energy Conservation
FSS-7246 FL BUSINESS
Miami, Florida
la
New Construction
Owner/Agent:
FIRST STRING SPACE INC
892 EAST RAILROAD AVE.
PEARSON, GA 31642
GCMG
0 2
Feb 05, 2019
APPROVED
Designer/Contractor.
JAMES BRADLEY P.E.
799 HALLECK CANYON RD.
WHEATLAND, WY 82201
1 HVAC System 1 (Single Zone):
Heating: 1 each - Other, Electric, Capacity = 36000 kBtulh
No minimum efficiency requirement applies
Cooling: 1 each - Other, Capacity = 36000 kBtulh, Air -Cooled Condenser, No Economizer, Economizer exception: Low Operating
Hours
D« Slgnm by minimum efficiency requirement applies
E
�i 74 ystem: None
459aDEa633A9480...
Mechanical Compliance Statement
Compliance Statement., The proposed mechanical design represented in this document Is consistent
specifications, and other calculations submitted with this permit application. The proposed mechanic
designed to meet the 2017 Florida Building Code, Energy Conservation requirements in COMcheck V1
with any applicable mandatory requirements listed in the Inspection Checklist. _D s
James E. Bradley, P.E.
Name( 07MOlting Engineer -Sole Proprietorship
799 Halleck Canyon Road
Wheatland, WY 82201
2/5/2019
Project Title: FSS-7246 FL BUSINESS
Data filename: Untitled.cck
E•
4:'1.1.0 and to compI n
No. 16695
480 STATE OF Q
c�ORtO!•'��4�
ONALE �o
Report date: 02/05/19
Page 4 of 20
COMcheck Software Version 4.1.1.0
Exterior Lighting Compliance Certificate
Project Information
Energy Code:
Project Title:
Project Type:
Exterior Lighting Zone
Construction Site:
Allowed Exterior Lighting Power
A
Area/Surface Category
'GCMC 0
2017 Florida Building Code, Energy Conservation A"A
FSS-7240 FL BUSINESS Feb 05, 2019
New Construction
2 (Neighborhood business district) APPROVED
Owner/Agent:
FIRST STRING SPACE INC
892 EAST RAILROAD AVE.
PEARSON, GA 31642
B
Quantity
W-aa¢-1�.4. 10 .
Designer/Contractor:
JAMES BRADLEY P.E.
799 HALLECK CANYON RD.
WHEATLAND, WY 82201
C I D E
Allowed Tradable Allowed Watts
Watts / Unit Wattage (B X C)
Main entry 3 ft of door 20 Yes 60
Other door (not main entry) 3 it of door 20 Yes 60
Total Tradable Watts (a) = 120
Total Allowed Watts = 120
Total Allowed Supplemental Watts (b) = 600
(a) Wattage tradeoffs are only allowed between tradable areas/surfaces.
(b) A supplemental allowance equal to 600 watts may be applied toward compliance of both non -tradable and tradable areas/surfaces.
Proposed Exterior Lighting Power
A B C D E
Fixture ID : Description / Lamp / Wattage Per Lamp / Ballast Lamps/ # of Fixture (C X D)
Fixture Fixtures Watt.
Main entry (3 ft of door widtth): Tradable Wattage
Incandescent 1: Incandescent 60W:
60 60
Other door (not main entry) (3 ft of door width)? Tradable Wattage
Incandescent 2: Incandescent 60W: 1 1 60 60
Total Tradable Proposed Watts = 120
Exterior Lighting PASSES: Design 83% better than code
Exterior Lighting Compliance Statement ,,,,,,,,,,,,,,,,•_
Compliance Statement The proposed exterior lighting design represented in this document is con
specifications, and other calculations submitted with this permit application. The proposed exterior
designed to meet the 2017 Florida Building Code, Energy Conservation requirements in COMcheck
with any applicable mandatory requirements listed in the Inspection Checklist.
James E. Bradley, P.E.
NameccT t tilting Engineer - Sole Proprietorship
799 Halleck Canyon Road
Wheatland, WY 82201
Project Title: FSS-7246 FL BUSINESS
Data fllename: Untltled,cck
No.16695 i
rc to
aeo._ STATE OF :•@
v
90 c4OR1OP•
NAL
2/5/2019
Report date: 02/05/19
Page 3 of 20
COMcheck Software Version 4.1.1.0
Interior Lighting Compliance Certificate
Project Information GCMC
Energy Code: 2017 Florida Building Code, Energy Conservation
Project Title: FSS-7246 FL BUSINESS Feb 05, 2019
Project Type: New Construction
Construction Site:
Additional Efficiency Package(s)
On -site Renewable Energy
Allowed Interior Lighting Power
Owner/Agent:
FIRST STRING SPACE INC
892 EAST RAILROAD AVE.
PEARSON, GA 31642
A
Area Category
APPROVED
.� �.
Designer/Contractor:
JAMES BRADLEY P.E.
799 HALLECK CANYON RD.
WHEATLAND, WY 82201
B C D
Floor Area Allowed Allowed Watts
(ft2) Watts / ft2 (B X C)
1Office 654 0.82 536
Total Allowed Watts = 536
Proposed Interior Lighting Power
A B C D E
Fixture ID: Description / Lamp / Wattage Per Lamp / Ballast Lamps/ # of Fixture (C X D)
Fixture Fixtures Watt.
]-Ciffire
Linear Fluorescent 1: 48" T8 25W (Super T8): Electronic: 2 9 44 396
Incandescent 1: Incandescent 60W: 1 1 60 60
Total Proposed Watts = 456
Interior Lighting Compliance Statement
Compliance Statement: The proposed Interior lighting design represented in this document is cons
specifications, and other calculations submitted with this permit application. The proposed interior
designed to meet the 2017 Florida Building Code, Energy Conservation requirements in COMcheck
with any applicable mandatory requirements listed In the Inspection Checklist.
James E. Bradley. P.E.
Namt-o} tWIting Engineer - Sole Proprietorship
799 Halleck Canyon Road
Wheatland, WY 82201
NO. 18995
7[. rte 1
480... 7t�
9'• STATE OF ' T
A YJ
ORI
NALLEN�'\���
2/5/2019
Project Title: FSS-7246 FL BUSINESS Report date: 02/05/19
Data filename: Untitled.cck Page 2 of 20
Job t
Truss
I Truss Type
Gly
Ply
First String Space 316 GA
91:
P1184505
KINGPOST
1
1
Ref. #3164614
Universal Forest Products Inc., Grand Rapids, MI 49525, Weston Gorby 8.130 a Dec 12 2017 MiTek Industries, Inc. Mon Mar 1210:43:59 2018 Page 1 of 1
Copyright Q201 8 Universal Forest Products, Inc. All Rights Reserved
' 2-10-0 ' 3-M 3-0-8 2-1 0-0
0.88 12
S1 10 3.4 =
2z3 II 2 3x4 II 3 3x4 II ad1 II
T1 Tl 6
q
W1
W2
vW
.. 10X20Duct-. - --10x20 Duct ___ .. 10x20 DUG
W2
N—
qq
Ra
W1
e
5x5 = to 1X.1 II -High Wind Speed Truss" 1z3 II 12 5z5 =
g Exercise caution to ensure allfield connections and supports
are properly specified by a design professional to transmit the required forces 6
2-10-0 1 6-1-0 2-10-0
' 11-9-0 (11-0-0 to 11-9-0)
Plate Offsets
— 2:0-1-12 0-1-0
4:0-1-12 0-1-0 6:0-2-8 0-2-12
9:0-2-8 0-2-12
SPACING-:2-0-0
SPACING-: 14-0
SPACING- 2-0-0
CSI.
DEFL. in (loc) Vdefl Lid
PLATES GRIP
LOADING (psf)
LOADING (psf)
Plate Grip DOL 1.25
TC 0.49
Vert(LL) 0.05 7-8 >999 240
MT20 2441190
TCLL 30.0
TCLL 45.0
Lumber DOL 1.25
BC 0.36
Vert(CT) -0.08 7-8 >999 180
TCDL 15.0
TCDL 22.5
Rep Stress Incr YES
WB 0.19
Horz(CT) 0.02 6 Na n/a
BCLL 0.0 '
BCLL 0.0 '
Code FBC2017rrPi2014
Matrix-R
Weight: 50 lb
BCDL 10.0
BCDL 15.0
FT=0%
LUMBER- BRACING -
TOP CHORD 2x4 SP No.2 TOP CHORD Structural wood sheathing directly applied or 5-8-14 oc
BOT CHORD 2x4 SP No.2 puffins, except end verticals.
WEBS 2x4 SP No.2 BOT CHORD Rigid ceiling directly applied or 6A-0 oc bracing.
REACTIONS. (lb/size) 9=63010-3-8 (min. 0-1-8), 6=630/0-3-8 (min. 0-1.8)
Max Horz 9=121(LC 6)
Max Uplift 9=-428(LC 5), 6=-428(LC 6) 'GCMG 6
1
FORCES. (lb) - Maximum Compression/Maximum Tension
TOP CHORD 1-2=31/99, 2-3=985/1045, 3.4=985/1045, 4-5=-01/99, 1-9=72/96, 5-6=72/96 Feb 05, 2019
BOT CHORD 9-10=871/971, 8-10=871/971. 8-11=871/971, 7-11=871/971, 7-12=871/971, 6-12=871/971
WEBS 2-8=0/208, 4-7=0/208, 2-9=1087/1052, 4-6=108711052 APPROVED
NOTES-
1) This truss has been checked for uniform roof five load only, except as noted.
2) Wind: ASCE 7-10; Vult=181 mph (3-second gust) Vasd=140mph @241n o.c.; HVHZ; TCDL=6.Opsf; BCDL=4.Opsf;
E-signed by Kevin Freeman
(Alt. 180mph @16in o.c.; TCDL=9.Opsf; BCDL=6.Opsf); h=30ft; Cat. II; Exp C; Encl., GCpi=0.18; MWFRS
(envelope) gable end zone and C-C Exterior(2) zone; end vertical left and right exposed;C-C for members and `111111111111
& s or reactionsshown:0.0 Mete grip DOL=1.60 %��\N F R EFL ����
3) This trusforces
has been designed for a psf bottom chord load nonconcu ent with any other live loads.
4) • This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3$0 ��` XLl: '� G E N 8 -•. 92 �i�
tall by 2-0-0 wide will fit between the bottom chord and any other members.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 428 lb uplift at joint 9 N o 56254 •:
and 428 lb uplift at joint 6. * :�
6) When adjusting the variable span dimension, adjust the post placement dimensions proportional to the change in =
span. —
7) Based on: P1184504
8) Revision: Updated code l(/
A11
;,,\�,,`
The
professional engineering seal indicates that a licensed professional has reviewed the design under the standards referenced within this document]sgi0111
net necessarily the cement state building cads. The engineering seal is not an approval to use in a specific state. Thermal determination on whether 311212018
a buss design is acceptable under the locally adopted building code rest with the building official ordesignaled appointee.
®WARNING - Verify design parameters and READ NOTES Universal Forest Products, Inc. 2801 EAST BELTLINE RD, NE
PHONE (616)-364 6161 FAX (616)-365-0060 GRAND RAPIDS. MI 49525
Toss shall not be odor mroafiad without approval ofthetruss design engineer.
This component has only been designed forthe loads noted on Otis drawing, construction and lifting forces have nolbeen considered The builder is responsible
forrtltlngmethodsandsystemdesign. Sulderresponsaiitles are defined underTPll. This design is based only upon parameters slaws, and is for
an individual building componenito be Installed and loaded veNrally. Applicability otdesgn parameters and properinceryorabon of component is responsibility of balding
designer -not sees designer. Bracing shaven is forlatend support Mindividualweb members only. Adddonal temporary bracirg be Insure slabiliy during construction
Is the rasponsibilty ofthe erector. Additional permanent bracing of the overall structure is the responsibility of the building designer. Forgeneral guidonce regarding
%W661166, "WORM. w4fly, Bills nQFA tiffle Q,MU11=1I=dfi10m Ihg wood T1108 C0111101 GIAMR100 and Tense Plata Instllule Rewmerandatlon available
KB611A�A,§108€616f@fi§e6N,Madi§66,Vr1§lit® di1§u@ygIIMAiNk®up&II961�18teeWplpg