Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Klepp permit info
All APPLICABLE INFO MUST BE COMPLETED FOR APPLICATION TO BE ACCEPTED Date: 6/23/20 Permit Number: �+C3t1 �T � � c� rz � '`cs Planning and Development Services Building and Code Regulation Division 2300 Virginia Avenue, Fort Pierce FL 34982 Phone: (772) 462-1553 Fax: (772) 462-1578 PERMITTYPE: ELECTRIC PROPOSE© }MPRUVEMENT LUCATiON: Address: 8734 TOMPSON POINT ROAD Property Tax ID #: 3327-704-0004-000-2 Site Plan Name: KLEPP Project Name: KLEPP Building Permit Application Commercial Residential X Lot No. 3 Block No. DETAILED DESCRIPTION. OF WORK: SUPPLY AND INSTALL A PIPED IN AFCI CIRCUIT FROM THE METER MAIN COMBO FOR A NEW MICROWAVE DRAWER. ALSO CONSTRUCTION INFORMATION: Additional work to be performed under this permit —check all that apply: Mechanical _Gas Tank _Gas Piping _Shutters _Windows/Doors Electric _Plumbing Total Sq. Ft of Construction: Cost of Construction: $ 1328.07 Sprinklers _Generator _Roof Pitch Sq. Ft. of First Floor: Utilities: _Sewer _Septic Building Height: OWNER/LESSEE: CONTRACTOR: Name KELLY KLEPP Name: ,JOHN PANKRAZ Address: 8734 TOMPSON POINT ROAD Company: ELITE ELECTRIC AND AIR City: PORT ST LUCIE State: I'-� Zip Code: 34986 Fax: Phone No. 772-302-3772 Address: 1691 SW SOUTH MACEDO BLVD City: PORT ST LUGIE State: FL Zip Code: 34984 Fax: 772-340-3702 Phone No 772-340-3797 E-Mail: KKLEPP10504@HOTMAIL.COM Fill in fee simple Title Holder on next page (if different from the Owner listed above, E-Mail PERMIT@ELITEELECTRICANDAIR.COM State or County License EC13006036 If value of construction is $2500 or more, a RECORDED Notice of Commencement is required. If value of HVAC is $7,500 or more, a RECORDED Notice of Commencement is required. SUPPLEMENTAL CONSTRIJCTI�N �.11=N LAIN INFCIRMAT1tJN DESIGNER/ENGINEER: x Not Applicable Name: MORTGAGE COMPANY: -,�--Not Applicable Name: Address: City: _ State: Zip: Phone Address: City: State: Zip: Phone: FEE SIMPLE TITLE HOLDER: 1C .Not Applicable Name: BONDING COMPANY: _Nat Applicable Name: Address: Address: city: city: Zip: Phone: Zip: Phone: OWNER) CONTRACTOR AFFiDV1T: ,4pplication is hereby made to obtain a permit to do the work and installation as indicated. I certify that no work or installation has cclmmenced prior to the issuance of a permit. St. Lucie County makes no representation ?that is granting a permit will authorize the permit holder to build the subject structure which is in conflict with any applicable Horne Owners Association rules, bylaws or and covenants that may restrict or prohibit such structure. Please consult with your Home Owners Association and review your deed for any restrictions which may apply. In consideration of the granting of this requested permit, I do hereby agree that I will, in all respects, perform the work in accordance with the approved plans, thE> Florida Building Codes and St. Lucie County Amendments. The following building permit applications are exempt from undergoing a full concurrency review: room additions, accessory structures, swimming pools, fences, walls, signs, screen rooms and accessary uses to another non-residential use "WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT." n �i Signature of Own r/ Lessee/Contractor as Agent for Owner Signature of Cont or/License Holder STATE OF FLORIDA STATE OF FLORIDA COUNTY OF sTLucIE COUNTY OF STLUCIE The forgoing instrument was acknowledged before me The forgoing instrument was acknowledged before me this 23 day of JUNE ZQ_ by this 23 day Of DUNE , ZQ b Y JOHN PANKRAZ JOHN PANKR,4Z Name of person making statement. Name of person making statement. Personally Known x OR Produced Identification Personally Known x OR Produced Identification Type of Identification Type of Identification Produced Produced ,,,,,,, , , ,; •tP��� �.� H •. KONNI LENAE DEWITT \,SP��:;'�,� �( ,,- KOIJfJI LENAE DEWITT -; Notary Public —State of Florda � , <.� . ; ; • Commission # GG 166915 * �'�+�� y Public — State of Florida ,�i� c 10 2021 , • . „ + • a Commission # GG 166915 (Signature of otary Pu li�l '°b ),�ji�aa�hNallonalNotaryAssn. (Signature of Notar P", � �;'�fa Ih��i�l� �i ,,,, n alNolaryAssn. Commission No. GG166915 (Seal) Commission No. G�1sssls (Seal) REVIEWS FRONT ZONING SUPERVISOR PLANS VEGETATION SEA TURTLE MANGROVE COUNTER REVIEViJ REVIEW REVIEW REVIEW REVIEW REVIEW DATE RECEIVED DATE COMPLETED Rev. 7 1 6l23/2020 Job (1530X2040) El��ta-i��I mad �al�aa��>�o;r�� Project: Location: Existing Service s eeder Size::-.C?t-` Existing Panel Site: � ��� ,e _$Xlstln ���dS jSq. Ft. X 3 watts per sq. ft............................ � watts .-� _=��Applianee cis. @1500 watts each .................... � watts ��Laundry cis. @ I500 watts each ......... .............`.� watts '� ._Range @ 8 kw.................................................���',r�res,� —watts Dishwasher and disposal @ I500 watts each......_�,:� ��,,1.,�_watts 1 _Microwave @ 2000 watts .............................`' � ,_watts _—t__Water heater @ 4.5 kw................................_watts Tankless water heater .................................. watts _Dryer �a 5 kw .............. � watts �C _Refrigerator @ I500 watts........................�_��_watts Bathroom 2 @ 1500 waits .......................... �,�� watts ____Sprinkler ump ......................................,�. c� watts ___� Other _ watts r i � ............. �t�—Other - L.-. ................. watts Other waits Sub toial LWatts �,ew Lo ds Poolpump ............................................... watts Pooilight ............................................... watts Heatpump ............................................... watts Chlocine generator ...................................... watts Airbiowes................................................ watts Boattift............... ................ watts Other ................ watts Other ................ watts ............... watts Tota! s� Watts t � First 10 kw Q 100%............................ .......... watts ..... .. �-- __{�'' Remainder @ 40°f°................................................ r watts ... L� s?AlC heat @ 100°to...................... ..,,....,.. �;;2�„��„-s watts j �� Total watts ��� Divided by 240 votts�-- - � � ' �- - - Ames Prepared by. `--x'����(`'��-z��' Date,r;�::..� Other, https://go.servicetitan.com/Attach/Job?name=Attaches%2F40a2a7a3-72d3-41 cc-91 bb-a94b7bd2c51 a_cdv_photo_001-ir6fg61mgj.jpg 1 /1 c7 d I� a O O 1 O O 3 Q N c N W N O N O O i � '- N O A 0 x <! cn W O Michelle Franklin, CFA -- Saint Lucie County Property Appraiser --All rights reserved. Property Identification Site Address: 8734 Tompson Parcel ID: 3327-704-0004- Account #: 154124 Sec/Town/Range: 34/36S/39E Point RD 000-2 Map ID: 33/34N Zoning: Planned Un Use Type: 0100 Jurisdiction: Saint Lucie County Ownership Legal Description Kjellaug M Klepp (LF EST) TOMPSON POINT PUD AT PGA VILLAGE (PB 43-10) LOT 3 8734 Tompson Point RD (OR 4040-861; 4072-2563) Port Saint Lucie, FL 34986 Current Values Historical Values 3-year Just/Market: $437,300 Assessed: $436,233 Year Just/Market Assessed Exemptions Taxable Exemptions: $50,500 Taxable: $385,733 2019 $437,300 $436,233 $50,500 $385,733 2018 $428,100 $428,100 $50,500 $377,600 2017 $392,100 $392,100 $0 $392,100 Sale History Date Book/Page Sale Code Deed Grantor Price 11-30-2017 4072 / 2563 0114 WD Klepp Kjellaug $100 08-30-2017 4040 / 0861 0001 WD H2OWN Investments LP $540,000 11-26-2013 3587 / 2471 0001 WD Halbert Raymond $550,000 Primary Building Information Finished Area of this building: 3,010 SF Gross Sketched Area: 5,419 SF View: Year Built: 2005 Primary Wall: CB Stucco Bedrooms: 4 Full Baths: 4 Half Baths: 1 Roof Cover: Conc Tile Frame: Story Height: 1 Story A/c °i°: loo°i° Heated %: 100% Sprinkled %: 0% Exterior Data Roof Structure: Hip Grade: A No. Units: 1 Interior Data Electric: MAXIMUM Heat Type: FrcdHotAir Heat Fuel: ELEC Building Type: HA Effective Year: 2005 Secondary Wall: Primary Int Wall: Avg Hgt/Floor: 0 Primary Floors: Tile -Ceramic ��E, xi Total Areas _�, FinishedlUnder Air 3,010 (SF): "'°' Gross Sketched Area 5,419 ;, (SF): n � '° Land Size (acres): 0.24 ��, Land Size (SF}: 10,454 Total Building Count: 1 Special Features and Yard Items Type Qty Units Year Blt RES POOL AVG 1 450 2005 POOL ENC-AVG 1 1523 2005 Drive-BrkPav 1 765 2005 POOL DK-AVG 1 1048 2005 SPA -HOT TUB 1 25 2005 POOL HEATER 1 1 2005 All information is believed to be correct at this time, but is subject to change and is provided without any warranty. © Copyright 2020 Saint Lucie County Property Appraiser. All rights reserved.