Loading...
HomeMy WebLinkAboutEnergy CodeFORM R405-2017 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance McTREWED Project Name: Lot 29 Block 1 Waterstone 2000 CRGL Builder Name: ADAMS HOMES APR Street: 5343 Lugo Street Permit Office: permitting Depart City, State, Zip: Fort Pierce, FL, 34951 Permit Number. St. Lucie Count Owner: Jurisdiction: 661000 Design Location: FL, ST_LUCIE_CO_INTL County: St. Lucie (Florida Climate Zone 2 ) 1. New construction or existing New (From Plans) 9. Wall Types(1940.4 sgft.) Insulation Area 2. Single family or multiple family Single-family a. Concrete Block - Inl Insul, Exterior R=4.1 1428.20 ft2 b. Frame - Wood, Adjacent R=13.0 288.56 ft' 3. Number of units, if multiple family 1 c. Frame - Wood, Exterior R=13.0 223.66 ft' 4. Number of Bedrooms 4 d. N/A R= ft2 5. Is this a worst case? No 10. Ceiling Types (2004.0 sqft.) Insulation Area a. Under Attic (Vented) R=30.0 2004.00 ft2 6. Conditioned Floor area above grade (W) 2004 b. N/A R= ft2 Conditioned Boor area below grade (ft2) 0 c. A R= ft2 11. Ducts R ft2 7. Windows(208.7 sgft.) Description Area a. Sup: Attic, Ret: Main, AH: Main 6 400.8 a. U-Factor: Dbl, U=0.33 136.36 ft2 SHGC: SHGC=0.23 b. U-Factor: Dbl, U=0.33 38.54 ft2 12. Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.21 a. Central Unit 35.0 SEER:15.50 c. U-Factor: Dbl, U=0.55 17.78 ft2 SHGC: SHGC=0.70 13. Heating systems kBtu/hr Efficiency d. U-Factor: other (see details) 16.00 ft2 a. Electric Heat Pump 34.6 HSPF:8.50 SHGC: other (see details) Area Weighted Average Overhang Depth: 1.153 ft. Area Weighted Average SHGC: 0.272 14. Hot water systems B. Floor Types (2004.0 sqR.) Insulation Area a. Electric Cap: 40 gallons a. Slab -On -Grade Edge Insulation R=0.0 2004.00 ft2 b. Conservation features EF: 0.940 b. N/A R= ft2 None c. N/A R= ft2 15. Credits Pstat Glass/Floor Area: 0.104 Total Proposed Modified Loads: 64.18 PASS Total Baseline Loads: 65.80 I hereby certify that the plans and specifications covered by Review of the plans and S741A this calculation are in complian i he Florida En rgy�'1� specifications covered by this OF'y14E v Off, Code. calculation indicates compliance,.'sue with the Florida Energy Code. ✓;. u„ ?: rt„ �0 PREPARED BY: Before construction is completed C4 to DATE: 2-94-9mn Winn Kenman this building will be inspected for compliance with Section 553.908 R' I hereby certify that this building, as designed, is in compliance Florida Statutes. with the Florida Ener Code. .�0 COD WE OWNERIAGENT: BUILDING OFFICIAL: �j DATE: DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2). :nt 2/24/2020 4:19 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 4 FORM R405-2017 INPIIT RIIMMAPV rWPrIII ICT riPnnOT ,f PROJECT Title: Building Type: Owner Name: # of Units: Builder Name: Permit Office: Jurisdiction: Family Type: New/Existing: Comment: Lot 29 Block 1 Waterston 20 Bedrooms: 4 User Conditioned Area: 2004 Total Stories: 1 1 Worst Case: No ADAMS HOMES Rotate Angle: 0 Cross Ventilation: No 661000 Whole House Fan: No Single-family New (From Plans) Address Type: Street Address Lot # 29 Block/Subdivision: Waterstone PlatBook: Street: 5343 Lugo Street County: St. Lucie City, State, Zip: Fort Pierce, FL , 34961 CLIMATE / V Design Location Design Temp TMY Site 97.5 % 2.5 % Int Design Temp Heating Design Daily Temp Winter Summer Degree Days Moisture Range FL, ST_LUCIE_CO_INTL FL_VERO_BEACH_MUNI 39 90 70 75 299 58 Medium BLOCKS Number Name Area Volume 1 Blockl 2004 18837.6 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfI ID Finished Cooled Heated 1 Main 2004 18837.6 Yes 5 4 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter R-Value Area Tile Wood Carpet 1 Slab -On -Grade Edge Insulatio Main 181.9 ft 0 2004 ft2 ---- 0.35 0 0.65 ROOF / V # Type Roof Gable Roof Materials Area Area Color Red Solar SA Emitt Emitt Deck Pitch Bar Absor. Tested Tested Insul. (deg) 1 Gable or Shed Composition shingles 2241 ft2 502 ft2 Medium N 0.85 N 0.85 No 0 26.6 ATTIC / v # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Vented 300 2004 ft2 N N CEILING # Ceiling Type Space R-Value Ins Type Area Framing Free Truss Type 1 Under Attic (Vented) Main 30 Blown 2004 ft2 0.11 Wood 2/24/2020 4:19 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 2 of 4 r FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT WALLS Adjacent Space p. Cavity Width Height Sheathing Framing Solar Below 0 1 S Exterior Concrete Block - Int Insul Main 4.1 53 7 9 7 613.5 ft2 0 0 0.6 0 2 W Exterior Concrete Block - Int Insul Main 4.1 20 0 9 4 186.7 ft2 0 0 0.6 0 3 N Exterior Frame - Wood Main 13 25 1 8 11 223.7 ft2 0 0.23 0.6 0 4 N Exterior Concrete Block - Int Insul Main 4.1 39 0 9 4 364.0 ft2 0 0 0.6 0 5 E Exterior Concrete Block - Int Insul Main 4.1 37 4 9 9 364.0 ft2 0 0.6 0 6 - Garage Frame - Wood Main 13 30 11 9 4 288.6 ft2 0 0.23 0.01 0 DOORS # Ornt Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 - Wood Main None .26 2 8 6 8 17.8 ft- 2 W Insulated Main None .25 3 6 8 20 ft2 WINDOWS Orientation shown is the entered, Proposed orientation. _ / Wall Overhang V # Ornt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 S 1 Vinyl Low-E Double Yes 0.33 0.23 N 6.9 ft2 1 ft O in 0 ft 10 in None None 2 S 1 Vinyl Low-E Double Yes 0.33 0.23 N 16.2 ft2 1 ft 0 in 0 ft 10 in None None 3 W 2 Vinyl Low-E Double Yes 0.33 0.31 N 16.0 ft2 3 ft 0 in 1 ft 0 in None None 4 W 2 Vinyl Low-E Double Yes 0.33 0.21 N 38.5 ft2 1 ft 0 in 0 ft 10 in None None 5 N 3 Vinyl Low-E Double Yes 0.33 0.23 N 32.4 ft2 1 ft 0 in 0 ft 10 in None None 6 E 5 Vinyl Low-E Double Yes 0.55 0.7 N 17.8 ft2 1 ft 0 in 1 ft 0 in None None 7 E 5 Vinyl Low-E Double Yes 0.33 0.23 N 80.9 ft2 1 ft 0 in 0 R 10 in None None GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 483 ft2 483 ft2 64 ft 8 ft 1 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000418 2197.7 120.65 226.9 .1545 7 HEATING SYSTEM # System Type Subtype Efficiency Capacity Block Ducts 1 Electric Heat Pump/ Split HSPF:8.5 34.6 kBtu/hr 1 sys#1 2/24/2020 4:19 PM EnergyGauge@ USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 3 of 4 FORM R405-2017 INPUT SUMMARY CHFCKI IST RFPnRT COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/ Split SEER: 15.5 35 kBtu/hr 1167 cfm 0.75 1 sys#1 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.94 40 gal 62.3 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Collector Storage Cart # Company Name System Model # Collector Model # Area Volume FEF None None g2 DUCTS _ / —Supply— —Return Air CFM 25 CFM25 HVAC# V # Location R-Value Area Location Area Leakage Type Handler TOT OUT ON RLF Heat Cool 1 Attic 6 400.8 ft Main 100.2 ft Default Leakage Main (Default) (Default) 1 1 TEMPERATURES Programablee CFans: CoolJan Feb Heating [X] Jan Feb [[ ]] [X] Mar Aprr rreiling �X] [X] Jun [ ] Jul [ ] Aug [�X(]] I) Sep l J Oct Nov Dec Venting [O] Jan I 1 Feb l J t(�XJI Mar Apr [ May Jun I 1 Jul I 1 Aug II 11 Sep lxl Oc Nov Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating (WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating (WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 MASS Mass Type Area Thickness Furniture Fraction Space Default 8 lbs/sci.ft. 0 ft2 0 ft 0.3 Main 2/24/2020 4:19 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 4 of 4 2017 EPL DISPLAY CARD ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX' = 98 The lower the Energy Performance Index, the more efficient the home. 1. New home or, addition 1. New (From Plans) 12. Ducts, location & insulation level a) Supply ducts R 6.0 2. Single-family or multiple -family 2. Single-family b) Return ducts R 6.0 3. No. of units (if multiple -family) 3. 1 c) AHU location Main 4. Number of bedrooms 4. 4 5. Is this a worst case? (yes/no) 5. No 6. Conditioned floor area (sq. ft.) 6. 2004 7. Windows, type and area a) U-factor:(weighted average) 7a. 0.349 b) Solar Heat Gain Coefficient (SHGC) 7b. 0.272 c) Area 7c. 208.7 8. Skylights a) U-factor:(weighted average) 8a. NA b) Solar Heat Gain Coefficient (SHGC) 8b. NA 9. Floor type, insulation level: a) Slab -on -grade (R-value) 9a. 0.0 b) Wood, raised (R-value) 9b. c) Concrete, raised (R-value) 9c. 10. Wall type and insulation: A. Exterior: 1. Wood frame (Insulation R-value) 2. Masonry (Insulation R-value) B. Adjacent: 1. Wood frame (Insulation R-value) 2. Masonry (Insulation R-value) 11. Ceiling type and insulation level a) Under attic b) Single assembly c) Knee walls/skylight walls d) Radiant barrier installed 10A1. 13.0 10A2. 4.1 10B1. 13.0 10B2. 13. Cooling system: Capacity 35.0 a) Split system SEER 15.5 b) Single package SEER c) Ground/water source SEER/COP d) Room unit/PTAC EER e) Other 14. Heating system: Capacity34.6 a) Split system heat pump HSPF 8.5 b) Single package heat pump HSPF c) Electric resistance COP d) Gas furnace, natural gas AFUE e) Gas furnace, LPG AFUE f) Other 15. Water heating system a) Electric resistance EF 0.94 b) Gas fired, natural gas EF c) Gas fired, LPG EF d) Solar system with tank EF e) Dedicated heat pump with tank EF_ f) Heat recovery unit HeatRec% g) Other 16. HVAC credits claimed (Performance Method) a) Ceiling fans 1la. 30.0 b) Cross ventilation No 11b. c) Whole house fan No 11c. d) Multizone cooling credit 11d. No e) Multizone heating credit f) Programmable thermostat Yes 'Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. I certify that this home has complied with the Florida Building Code, Energy Conservation, through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL display card will be completed based on installed code compliant features. Builder Signature: Date: Address of New Home: 5343 Lugo Street I City/FL Zip: Fort Pierce, FL 34951 2/24/2020 4:19:14 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1