HomeMy WebLinkAboutEnergy CodeFORM R405-2017
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance McTREWED
Project Name: Lot 29 Block 1 Waterstone 2000 CRGL
Builder Name: ADAMS HOMES
APR
Street: 5343 Lugo Street
Permit Office:
permitting Depart
City, State, Zip: Fort Pierce, FL, 34951
Permit Number.
St. Lucie Count
Owner:
Jurisdiction: 661000
Design Location: FL, ST_LUCIE_CO_INTL
County: St. Lucie (Florida Climate
Zone 2 )
1. New construction or existing New (From Plans)
9. Wall Types(1940.4 sgft.)
Insulation Area
2. Single family or multiple family Single-family
a. Concrete Block - Inl Insul, Exterior
R=4.1 1428.20 ft2
b. Frame - Wood, Adjacent
R=13.0 288.56 ft'
3. Number of units, if multiple family 1
c. Frame - Wood, Exterior
R=13.0 223.66 ft'
4. Number of Bedrooms 4
d. N/A
R= ft2
5. Is this a worst case? No
10. Ceiling Types (2004.0 sqft.)
Insulation Area
a. Under Attic (Vented)
R=30.0 2004.00 ft2
6. Conditioned Floor area above grade (W) 2004
b. N/A
R= ft2
Conditioned Boor area below grade (ft2) 0
c. A
R= ft2
11. Ducts
R ft2
7. Windows(208.7 sgft.) Description Area
a. Sup: Attic, Ret: Main, AH: Main
6 400.8
a. U-Factor: Dbl, U=0.33 136.36 ft2
SHGC: SHGC=0.23
b. U-Factor: Dbl, U=0.33 38.54 ft2
12. Cooling systems
kBtu/hr Efficiency
SHGC: SHGC=0.21
a. Central Unit
35.0 SEER:15.50
c. U-Factor: Dbl, U=0.55 17.78 ft2
SHGC: SHGC=0.70
13. Heating systems
kBtu/hr Efficiency
d. U-Factor: other (see details) 16.00 ft2
a. Electric Heat Pump
34.6 HSPF:8.50
SHGC: other (see details)
Area Weighted Average Overhang Depth: 1.153 ft.
Area Weighted Average SHGC: 0.272
14. Hot water systems
B. Floor Types (2004.0 sqR.) Insulation Area
a. Electric
Cap: 40 gallons
a. Slab -On -Grade Edge Insulation R=0.0 2004.00 ft2
b. Conservation features
EF: 0.940
b. N/A R= ft2
None
c. N/A R= ft2
15. Credits
Pstat
Glass/Floor Area: 0.104 Total Proposed Modified Loads: 64.18
PASS
Total Baseline Loads: 65.80
I hereby certify that the plans and specifications covered by
Review of the plans and
S741A
this calculation are in complian i he Florida En rgy�'1�
specifications covered by this
OF'y14E
v Off,
Code.
calculation indicates compliance,.'sue
with the Florida Energy Code.
✓;. u„ ?: rt„ �0
PREPARED BY:
Before construction is completed
C4 to
DATE: 2-94-9mn Winn Kenman
this building will be inspected for
compliance with Section 553.908
R'
I hereby certify that this building, as designed, is in compliance
Florida Statutes.
with the Florida Ener Code.
.�0
COD WE
OWNERIAGENT:
BUILDING OFFICIAL: �j
DATE:
DATE:
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory -sealed in accordance with R403.3.2.1.
- Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an
envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2).
:nt
2/24/2020 4:19 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 4
FORM R405-2017 INPIIT RIIMMAPV rWPrIII ICT riPnnOT
,f
PROJECT
Title:
Building Type:
Owner Name:
# of Units:
Builder Name:
Permit Office:
Jurisdiction:
Family Type:
New/Existing:
Comment:
Lot 29 Block 1 Waterston 20 Bedrooms: 4
User Conditioned Area: 2004
Total Stories: 1
1 Worst Case: No
ADAMS HOMES Rotate Angle: 0
Cross Ventilation: No
661000 Whole House Fan: No
Single-family
New (From Plans)
Address Type: Street Address
Lot # 29
Block/Subdivision: Waterstone
PlatBook:
Street: 5343 Lugo Street
County: St. Lucie
City, State, Zip: Fort Pierce,
FL , 34961
CLIMATE
/
V Design Location
Design Temp
TMY Site 97.5 % 2.5 %
Int Design Temp Heating Design Daily Temp
Winter Summer Degree Days Moisture Range
FL, ST_LUCIE_CO_INTL FL_VERO_BEACH_MUNI 39 90
70 75 299 58 Medium
BLOCKS
Number
Name
Area Volume
1
Blockl
2004 18837.6
SPACES
Number
Name
Area Volume Kitchen Occupants
Bedrooms InfI ID Finished Cooled Heated
1
Main
2004 18837.6 Yes 5
4 1 Yes Yes Yes
FLOORS
#
Floor Type
Space Perimeter R-Value
Area Tile Wood Carpet
1 Slab -On -Grade Edge Insulatio Main 181.9 ft 0
2004 ft2 ---- 0.35 0 0.65
ROOF
/
V #
Type
Roof Gable Roof
Materials Area Area Color
Red Solar SA Emitt Emitt Deck Pitch
Bar Absor. Tested Tested Insul. (deg)
1
Gable or Shed Composition shingles 2241 ft2 502 ft2 Medium
N 0.85 N 0.85 No 0 26.6
ATTIC
/
v #
Type
Ventilation Vent Ratio (1 in)
Area RBS IRCC
1
Full attic
Vented 300 2004 ft2 N N
CEILING
#
Ceiling Type
Space R-Value Ins Type Area Framing Free Truss Type
1
Under Attic (Vented)
Main 30 Blown
2004 ft2 0.11 Wood
2/24/2020 4:19 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 2 of 4
r
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
WALLS
Adjacent Space
p.
Cavity Width
Height
Sheathing Framing
Solar Below
0
1 S Exterior Concrete Block - Int Insul Main
4.1 53 7 9
7
613.5 ft2
0
0
0.6
0
2 W Exterior Concrete Block - Int Insul Main
4.1 20 0 9
4
186.7 ft2
0
0
0.6
0
3 N Exterior Frame - Wood Main
13 25 1 8
11
223.7 ft2
0
0.23
0.6
0
4 N Exterior Concrete Block - Int Insul Main
4.1 39 0 9
4
364.0 ft2
0
0
0.6
0
5 E Exterior Concrete Block - Int Insul Main
4.1 37 4 9
9
364.0 ft2
0
0.6
0
6 - Garage Frame - Wood Main
13 30 11 9
4
288.6 ft2
0
0.23
0.01
0
DOORS
# Ornt Door Type Space
Storms
U-Value
Width
Height
Area
Ft
In
Ft In
1 - Wood Main
None
.26
2
8
6 8
17.8 ft-
2 W Insulated Main
None
.25
3
6 8
20 ft2
WINDOWS
Orientation shown is the entered, Proposed orientation.
_ / Wall
Overhang
V # Ornt ID Frame Panes NFRC
U-Factor SHGC Imp
Area
Depth
Separation
Int Shade
Screening
1 S 1 Vinyl Low-E Double Yes
0.33 0.23 N
6.9 ft2
1 ft O in
0 ft 10 in
None
None
2 S 1 Vinyl Low-E Double Yes
0.33 0.23 N
16.2 ft2
1 ft 0 in
0 ft 10 in
None
None
3 W 2 Vinyl Low-E Double Yes
0.33 0.31 N
16.0 ft2
3 ft 0 in
1 ft 0 in
None
None
4 W 2 Vinyl Low-E Double Yes
0.33 0.21 N
38.5 ft2
1 ft 0 in
0 ft 10 in
None
None
5 N 3 Vinyl Low-E Double Yes
0.33 0.23 N
32.4 ft2
1 ft 0 in
0 ft 10 in
None
None
6 E 5 Vinyl Low-E Double Yes
0.55 0.7 N
17.8 ft2
1 ft 0 in
1 ft 0 in
None
None
7 E 5 Vinyl Low-E Double Yes
0.33 0.23 N
80.9 ft2
1 ft 0 in
0 R 10 in
None
None
GARAGE
# Floor Area Ceiling Area
Exposed Wall Perimeter
Avg. Wall Height
Exposed Wall Insulation
1 483 ft2 483 ft2
64 ft
8 ft
1
INFILTRATION
# Scope Method SLA CFM 50 ELA EgLA
ACH
ACH 50
1 Wholehouse Proposed ACH(50) .000418 2197.7 120.65 226.9
.1545
7
HEATING SYSTEM
# System Type Subtype
Efficiency
Capacity
Block
Ducts
1 Electric Heat Pump/ Split
HSPF:8.5
34.6 kBtu/hr
1
sys#1
2/24/2020 4:19 PM EnergyGauge@ USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 3 of 4
FORM R405-2017 INPUT SUMMARY CHFCKI IST RFPnRT
COOLING SYSTEM
# System Type
Subtype
Efficiency Capacity
Air Flow
SHR
Block
Ducts
1 Central Unit/
Split
SEER: 15.5 35 kBtu/hr
1167 cfm
0.75
1
sys#1
HOT WATER SYSTEM
# System Type
SubType
Location
EF Cap Use
SetPnt
Conservation
1 Electric
None
Garage
0.94 40 gal 62.3 gal
120 deg
None
SOLAR HOT WATER SYSTEM
FSEC
Collector
Storage
Cart # Company Name
System Model # Collector Model
# Area
Volume
FEF
None None
g2
DUCTS
_ / —Supply—
—Return Air
CFM 25 CFM25
HVAC#
V # Location R-Value Area
Location
Area Leakage Type Handler
TOT OUT
ON
RLF
Heat Cool
1 Attic
6 400.8 ft Main
100.2 ft Default Leakage Main
(Default) (Default)
1 1
TEMPERATURES
Programablee
CFans:
CoolJan Feb
Heating [X] Jan Feb
[[ ]]
[X] Mar
Aprr rreiling
�X] [X]
Jun [ ] Jul [ ] Aug
[�X(]]
I) Sep l J
Oct
Nov
Dec
Venting [O] Jan I 1 Feb
l J
t(�XJI Mar
Apr [
May Jun I 1 Jul I 1 Aug
II 11 Sep lxl
Oc
Nov
Dec
Thermostat Schedule: HERS 2006 Reference
Hours
Schedule Type
1
2 3
4 5 6 7
8 9
10
11
12
Cooling (WD) AM
78
78 78
78 78 78 78
78 80
80
80
80
PM
80
80 78
78 78 78 78
78 78
78
78
78
Cooling (WEH) AM
78
78 78
78 78 78 78
78 78
78
78
78
PM
78
78 78
78 78 78 78
78 78
78
78
78
Heating (WD) AM
66
66 66
66 66 68 68
68 68
68
68
68
PM
68
68 68
68 68 68 68
68 68
68
66
66
Heating (WEH) AM
66
66 66
66 66 68 68
68 68
68
68
68
PM
68
68 68
68 68 68 68
68 68
68
66
66
MASS
Mass Type
Area
Thickness Furniture Fraction Space
Default 8 lbs/sci.ft.
0 ft2
0 ft 0.3
Main
2/24/2020 4:19 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 4 of 4
2017 EPL DISPLAY CARD
ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX' = 98
The lower the Energy Performance Index, the more efficient the home.
1. New home or, addition 1. New (From Plans) 12. Ducts, location & insulation level
a) Supply ducts R 6.0
2. Single-family or multiple -family 2. Single-family b) Return ducts R 6.0
3. No. of units (if multiple -family) 3. 1 c) AHU location Main
4. Number of bedrooms
4.
4
5. Is this a worst case? (yes/no)
5.
No
6. Conditioned floor area (sq. ft.)
6.
2004
7. Windows, type and area
a) U-factor:(weighted average)
7a.
0.349
b) Solar Heat Gain Coefficient (SHGC)
7b.
0.272
c) Area
7c.
208.7
8. Skylights
a) U-factor:(weighted average)
8a.
NA
b) Solar Heat Gain Coefficient (SHGC)
8b.
NA
9. Floor type, insulation level:
a) Slab -on -grade (R-value)
9a.
0.0
b) Wood, raised (R-value)
9b.
c) Concrete, raised (R-value)
9c.
10. Wall type and insulation:
A. Exterior:
1. Wood frame (Insulation R-value)
2. Masonry (Insulation R-value)
B. Adjacent:
1. Wood frame (Insulation R-value)
2. Masonry (Insulation R-value)
11. Ceiling type and insulation level
a) Under attic
b) Single assembly
c) Knee walls/skylight walls
d) Radiant barrier installed
10A1. 13.0
10A2. 4.1
10B1. 13.0
10B2.
13. Cooling system:
Capacity 35.0
a) Split
system
SEER 15.5
b) Single
package
SEER
c) Ground/water source SEER/COP
d) Room unit/PTAC
EER
e) Other
14. Heating system: Capacity34.6
a) Split system heat pump HSPF 8.5
b) Single package heat pump HSPF
c) Electric resistance COP
d) Gas furnace, natural gas AFUE
e) Gas furnace, LPG AFUE
f) Other
15. Water heating system
a) Electric resistance EF 0.94
b) Gas fired, natural gas EF
c) Gas fired, LPG EF
d) Solar system with tank EF
e) Dedicated heat pump with tank EF_
f) Heat recovery unit HeatRec%
g) Other
16. HVAC credits claimed (Performance Method)
a) Ceiling fans
1la. 30.0 b) Cross ventilation No
11b. c) Whole house fan No
11c. d) Multizone cooling credit
11d. No e) Multizone heating credit
f) Programmable thermostat Yes
'Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
I certify that this home has complied with the Florida Building Code, Energy Conservation, through the above energy
saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL
display card will be completed based on installed code compliant features.
Builder Signature: Date:
Address of New Home: 5343 Lugo Street I City/FL Zip: Fort Pierce, FL 34951
2/24/2020 4:19:14 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1