Loading...
HomeMy WebLinkAboutConstruction PlansDESIGN CRITERIA: APPLICABLE CODES. REGULATIONS & STANDARDS 1. THE 2p14 FLORIDA BUILDING CODE, SPECIFICALLY CHAPTER 16 IS I TURAL DESIGN, CHAPTER 20 ALUMINUM & CH. 23 WOOD. 2. AA ASM 35 & SPECIFICATIONS FOR ALUMINUM STRUCTURES, PART 1-A OF THE ALUMINUM DESIGN MANUEL PREPARED BY THE ALUMINUM ASSOCIATION, INC. WASHINGTON D.C. 2005 ED. 3. ASCE 7-10 & SE17 4. NDS NATIONAL DESIGN SPECIFICATION FOR WOOD. 5. AC1318 CONCRETE REFRENCE MANUAL. WIND LOADS 1. BUILDING OCCUPANCY CATEGORY, PARAGRAPH 1604.5 & TABLE 1604.5: RISK CATEGORY 1. 2. BASIC WIND SPEED, TABLE 1609C, STATE OF FLORIDA DEBRIS REGION & BASIC WIND SPEED, PARAGRAPH 1609.3.1 & TABLE ' 1609.3.1 EQUIVALENT BASIC WIND SPEED: I50 MPH EXPOSURE CATEGORY, PARAGRAPH 1609.4.3: B 3. WIND LOADS PER FBC TABLE 2002.4 (MWFRS) VULT = 150 MPH & EXPOSURE = B FOR 20 X 20 X 0.013" MESH SCREEN HORIZONTAL PRESSURES ON WINDWARD SURFACES = 31 PSF HORIZONTAL PRESSURES ON LEEWARD SURFACES = 32 PSF VERTICAL PRESSURES ON SCREEN SURFACES = 9 PSF VERTICAL PRESSURES ON SOLID SURFACES = 25 PSF FOR 18 X 14 X 0.013" MESH SCREEN, APPLIED FACTOR = .88 FOR ALLOWABLE STRESS DESIGN, APPLIED FACTOR = .6 FOUNDATION DESIGN FOOTING SIZE EXISTING CONCRETE SLAB. NO ADDITIONAL FOOTING OR FOUNDATION SYSTEM IS REQUIRED BY THE PROPOSED CONSTRUCTION IF A MINIMUM 4" CONCRETE SLAB IS PROVIDED IN SOUND CONDITION, FREE FROM STRUCTURAL CRACKING, SPALLING & OTHER DETERIORATION. EXISTING FOUNDATION/FOOTING UNDER CONCRETE SLAB MINIMUM 8"x8" W/ (1) #5 BAR TO BE VERIFIED BY CONTRACTOR. SEE TYPICAL FOOTING DETAILS FOR NEW FOOTING DESIGN MINIMUM REQUIREMENTS. SPECIFICATIONS THE FOLLOWING SPECIFICATIONS ARE APPLICABLE TO THIS PROJECT: 1. WHERE CONCRETE SPECIFICATIONS ARE REQUIRED, WHETHER IN THE SCREEN ENCLOSURE SCOPE OF NOT, BY ONE OR MORE REGULATORY AGENCY, THE FOLLOWING SPECIFICATIONS ARE APPLICABLE: a. CONCRETE SHALL CONFORM TO ASTM C94 FOR THE FOLLOWING COMPONENTS: I. PORTLAND CEMENT TYPE I - ASTM C 150 ii AGGREGATES - LARGE AGGREGATE 3/4 MAX. - ASTM C 33 iii. AIR ENTRAINING+/- 1 %-ASTM C 260 iv. WATER REDUCING AGENT -ASTM C 494 v. CLEAN PORTABLE WATER vi. OTHER ADMIXTURES NOT PERMITTED b. METAL ACCESSORIES SHALL CONFORM TO: I. REINFORCING BARS - ASTM A615, GRADE 60 ii. WELDED WIRE FABRIC - ASTM Al85 c. CONCRETE SLUMP AT DISCHARGE CHUTE NOT LESS THAN 3" OR MORE THAN 5". WATER ADDED AFTER BATCHING IS NOT PERMITTED. d. PREPARE & PLACE CONCRETE PER AMERICAN CONCRETE INSTITUTE MANUAL OF STANDARD PRACTICE, PART 1, 2, & 3 INCLUDING HOT WHEATHER RECOMMENDATIONS. e. MOIST CURE OR POLYETHYLENE CURING PERMITTED. T. PRIOR TO PLACING CONCRETE, TREAT THE ENTIRE SUBSURFACE ARE FOR TERMITES IN COMPLIANCE WITH THE FBC. g. CONCRETE SHALL BE PLACED OVER A POLYETHYLENE VAPOR BARRIER. 2. WHEN PAVERS ARE UNDER ALUMINUM MEMBERS, CONTRACTOR SHALL EPDXY TO DECK OR GROUT TO DECK w/3000 PSI GROUT WITH BONDING AGENT 3. WHEN APPLICABLE FOR NEW SLAB ADDITION TO ADJACENT DRILL & EPDXY #5 X 8" REBAR INTO EX. FOUNDATION WITH I" MIN. HOLE, EMBED 4" MIN W/ NON -SHRINKING SIMPSON EPDXY -TIE (OR EQUAL) 48" O.C. TYP. ALL LOCATIONS 4. WHEN APPLICABLE FOR NEW FOOTER TO EXISTING, DRILL & EPDXY NEW STEEL INTO EX. FOUNDATION WITH 1"MIN. HOLE, EMBED 6" MIN W/ NON -SHRINKING SIMPSON EPDXY -TIE (OR EQUAL) TYP. ALL LOCATIONS 5. MINIMUM CONCRETE STRENGTH 3000 PSI UNLESS OTHERWISE NOTED. ALUMINUM SPECIFICATIONS 1. ALUMINUM EXTRUSIONS SHALL BE 6005 T5 ALLOY UNLESS OTHERWISE NOTED. 2. ALL SELF MATING BEAM SECTIONS ARE TO BE STITCHED WITH # 12 SCREWS 6" FROM ENDS & 24" CENTER TO CENTER. 3. ROOF BRACING SHALL BE A MINIMUM 2"X2X.050". 4. THE MINIMUM NORMAL THICKNESS OF PROTECTOR PANELS (KICKPLATES) SHALL BE AN INDUSTRY STANDARD OF 0.024 INCHES. 5. VINYL AND ACRYLIC PANELS SHALL BE REMOVED WHEN WIND SPEEDS EXCEED 75 MPH PER FBC. 6. SCREEN MATERIAL SHALL BE 18/14 SCREEN UNLESS APPROVED BY FLORIDA ENGINEERING LLC. 5. 1"X2" & 173" NON STRUCTURAL MEMBERS MAY BE USED INTERCHANGEABLY. FASTENER SPECIFICATIONS 1. FASTENERS ARE REQUIRED TO BE SAE GRADE 2 OR BETTER ZINC PLATED. (CONCRETE ANCHORS ARE TO BE TAPCONS OR BETTER, INSTALLED TO MFG. SPECIFICATIONS) 2. IT IS THE OWNERS RESPONSIBILITY TO MAINTAIN THE SCREENS, FASTENERS AND SCREENS TO MANUFACTURING SPECIFICATIONS. 3. WHERE WOOD DECK IS PRESENT USE 1 /4" X 3-1/2" GALV. LAG SCREWS IN LIEU OF MASONRY ANCHORS. UNLESS OTHERWISE SPECIFIED. 4. 1"X2" NON STRUCTURAL MEMBERS ATTACHED TO HOST A. FOR MASONRY/CONCRETE APPLICATION USE GALVANIZED 1 /4" X 2-3/4" TAPCONS OR EQUAL AT 24" O.C. AND 6" FROM ENDS B. FOR WOOD APPLICATION USE #14 X 2-3/4" WOOD SCREW AT 24" O.C. AND 6" FROM ENDS. C. FOR ALUMINUM APPLICATION USE #10 X 1-1 /2" SMS OR TEK SCREW AT 24" O.C. AND 6" FROM ENDS D. WHERE 1 "X2" INSTALLED THROUGHOUT AN "OPEN VIEW' SPACING SHALL BE REDUCED TO 18" O.C. AND 6" FROM ENDS MASONRY SPECIFICATIONS 1. CONCRETE MASONRY UNITS (CMU) SHALL BE STANDARD HOLLOW UNITS AND SHALL BE 1900 PSI MINIMUM BASED ON TYPE M OR S MORTAR. 2, ALL MORTAR SHALL BE TYPE M OR S. 3. ALL GROUT SHALL BE 2000 PSI MINIMUM AND HAVE MAXIMUM COARSE AGGREGATE SIZE OF 3/8". 4. PROVIDE CLEAN -OUTS FOR REINFORCED CELLS CONTAINING REINFORCEMENT WHEN GROUT POUR EXCEEDS 5-0" IN HEIGHT. MISCELLANEOUS 1. SCREENED ENCLOSURES CONTAINING SWIMMING POOLS SHALL COMPLY WITH THE APPLICABLE REQUIREMENTS OF FBC R4501.17 RESIDENTIAL SWIMMING BARRIER REQUIREMENTS. 2. ALUMINUM ADDITIONS ARE NOT TO BE INSTALLED ON A MANUFACTURED HOME, TRAILER HOME, OR PRE-FAB HOME. IF THE EXISTING STRUCTURE IS ONE OF THESE, A SEPERATE 4TH WALL SUPPORT SYSTEM IS SO TO BE ENGINEERED SO THAT NO ADDITIONAL LOADING IS PLACED ON THE MANUFACTURED HOME. 3. DOOR LOCATION MAY BE RELOCATED BY CONTRACTOR IN THE FIELD. 4. WHERE PAVERS ARE UNDER ALUMINUM MEMBERS, CONTRACTOR SHALL EPDXY TO DECK OR GROUT TO DECK w/3000 PSI GROUT WITH BONDING AGENT. 5. INTEGRITY OF EXISTING/ HOST STRUCTURE SHALL NOT BE COMPROMISED WITH THE ATTACHMENT OF THE PROPOSED STRUCTURE. 6. ALL 2X4 & GREATER ARE TO BE 2 x 4 SMB: 2"m"x0.044"xO.100" UNLESS OTHERWISE INDICATED. RESPONSIBILITIES I. ALL SITE WORK SHALL BE PERFORMED BY A LISCENED CONTRACTOR IN ACCORDANCE WITH APPLICABLE BUILDING CODES, LOCAL ORDANANCES, AND THE ENGINEER SHALL BE NOTIFIED OF ANY DISCREPANCIES. 2. FOR FASTENERS WHICH ARE NOT VISIBLE AFTER INSTALLATION, THE CONTRACTOR SHALL VERIFY AND ENSURE INSTALLATION HAS BEEN ACCOMPLISHED IN ACCORDANCE WITH MANUFACTURERS SPECIFICATIONS AND IN ACCORDANCE WITH THE ATTACHED DETAILS. 3. FOR "PICTURE WINDOW" MODIFICATION TO EXISTING SCREEN ENCLOSURES, ALL OTHER "EXISTING SCREEN ENCLOSURE' FEATURES ARE TO MEET THE TYPICAL DETAILS AS PROVIDED IN THESE DETAILS. CONTRACTOR IS TO VERIFY & ASSURE EXISTING SCREEN ENCLOSURE IS STRUCTUALLY SOUND. ALUMINUM MEMBERS DIMENSIONS HOLLOW SECTIONS 2 x 2: 2'X2'k0.044" 2 x 3: 2'k3"4.050" 2 x 4: 7k4"x0.050" 2 x 5: 2" 64.050" OPEN BACK SECTIONS 1 x2: F'<Z 0.04X 1 x 3: 1'k3`4.045" SNAP SECTIONS 2 x 2 SNAP: 2'k24.045" 2 x 3 SNAP: Z50' 0.050" 2 x 4 SNAP: Z'x4'k0.045" SELF MATING (SMB) 2 x 4 SMB: 7k4'k0.044'kXOA 00" 2 x 5 SMB: 2'k5'k0.050'4. 100" 2 x 6 SMB: 2'k6k0.059W. 120" 2 x 7 SMB: 2"x7'k0.057'k0.120" 2 x 8 SMB: 2'k8"x0.072'k0. 124" 2 x 9 SMB: 2"x9'k0.087-x0. 124" 2 x 10 SMB: 2'k10"x0.092"x0.398" DETAIL A FILE COPY YY�, OW I E 1 ED FOR CODE COMPLIANCE ST. LpCIE 0 801 COUNTY C wqlw VN�/ 0L w V z Lu LL 0 IL Q Z= N Lo m cM CO 0 O U p U Om - _I 0) IL Lo 'C �- M C F- C W a) Q U O a- w o, w m U ❑ W N N O N J F- LL W WU co Lij v Z IY w - OWD- I- a :E Lo W O � O 0 a DESIGN DATE: 05127/2020 REVISION 1: DATE REVISION 2: DATE PAGE: DRAWN BY: ST SCALE: NTS al 1X2 n7 2X2 DJ z o _ 2X2 DJ p _vt z O b 2X6 SMB v N l7 z Ln m >d> F F}-- w X x ci N 2X3 PB 1X2 N X N 0 N N HOST 12" 0/H (FASCIA MOUNT) -------------------------- I I I I I 3" X .024" X 1LB I a COMPOSITE PANELS o 3003-H154 0 1/4"-1' SLOPE (MIN.) (FL.# 21443.1) VIEW A -A 3" X .024" X 1LB COMPOSITE PANELS _ 3003-H154 0 1/4"-1' SLOPE (MIN.) (FL.# 21443.1) 0 ■ N 2X3X.050 EDGE BEAM m m X N X X _ N N /n d m X N •2L 4.• �y N =Z:c') 0 w 0 p. =C7:ILLI m W I¢- 4 :Z V = 0 F �: _ b`��... ......PROF , \ 1X2 M mZ Z Q E p w J O 0 W Q ILA 2X2 DJ a Z 0 LLj Z H- M C z 2X2 DJ Zn Q c o z of, vlBC.B_1_ N 2X6SMB N - -7- X N Q Q Q V • 3X3X. 225 F z N x � I w O O J N lv� DD 1 IL 6'-0"61-0" 6'-0"--ice 6'-0" 24'-0' EXISTING FOUNDATION 24"X.024" KICK PLATE TYP. j REVIEWED FOR m BODE COMPLIANCE ST. LUCIE COUNTY 1X2� f.�. VIEW A -A EXISTING FOUNDATION N N 0 N 0 z I- C) W O K d w_ LL ~ W D z Of w /n Z W_ Z 5 co a o H ° U 06 O F w UrLL z 0 00 0 l DESIGN DATE: 05/27/2020 REVISION 1: DATE REVISION 2: DATE PAGE: DRAWN BY: ST 2 SCAT E NTS .024 FLASHING SI' 'D WALL (TYP.) IF HE OOO FA O FA (3) WASHER AND & BOTTOM. FOR PANS BRAKE -FORMED ROOF HEADER CHANNEL (0_044" MIN. THICKNESS) HOST STRUCTURE \ 1/4"0 x2-1/2'LONG WOOD LAG SCREW OR MASONRY OR WOOD 1/4"0x2-1/4"LONG MASONRY ANCHORS @ 24" O.C. MAX. ROOF PANEL ATTACHMENT - MASONRY SCALE: N.T.S. (4) #10XI-1/7SMS INTO SCREW BOSSES CLIPS MAYBE USED UPRIGHT. BEAM -SNAP, SELF MATING, OR HOLLOW DETAIL "C" - GIRT OR PURLIN TO BEAM OR POST DETAIL SCALE: NTS EXISTING RAFTER ORTRUSS O v WASHER AND NEOPRENE GASKET O @ 12' O.C., TOP & BOTTOM (3) PER PAN FOR PANS EXTRUDED OR BRAKE -FORMED ROOF HEADER OR RECEIVING CHANNEL (0.044" MIN. THICKNESS) SECURE FASCIA TO EACH WITH MIN. 1-1/2'BEARING LEG. RAFTER TAIL W/ ( I) 1/4" 0 x 4" LONG PAN HEAD TAG SCREWS (1)1/4"0 x 2'LAG SCREW 24"O.C. BEFORE ATTACHING REC. CHANNEL ENTIRE LENGTH OF RECEIVING CHANNEL ROOF PANEL ATTACHMENT - WOOD FRAME SCALE: N.T.S. 1/8 'k2XYk ANGLE SELF -MATING OR 5032 H-32 ANGLE SNAP SECTION TYP. (2) - #O RY ANTO CHOR EACH Q VX2'O.B BASE PLATE-TYP. 1 /4( MASONRY ANCHOR EACH ANGLE - EACH SIDE COL. 1-114" MIN. CONC. ANCHOR EMBEDMENT 2-1/4" MIN. CONC. °• ° e 2'MIN. INCREASE DISTANCE ANCHOR EMBEDMENT WHEN GREATER THAN 2X4 SECONDARY ANGLE e e UPRIGHT IS USED 3000 PSI CONC. ° ° SLAB/ FTG. 6X6-IOXIOWWM SIDE VIEW OR FIBERMESH 1 /4" MASONRY ANCHOR AT EACH ANGLE (2) - # 12 SMS �1/4"TAPCON XL (RED HEAD MFG. OR EQUAL) 2-1/4" MIN. CONC. ! 2@Ix2 BASE ANCHOR EMBEDMENT 2 @ SLAB (BEYOND) SECONDARY ANGLE ° F2' BASE PLATE ANCHORED ° TO CONC W/ 114" MASONRY ANCHOR 6" MAX EACH SIDE OF POST AND 2f' O.C. MAX • ° °•�•• 1-1/4"CONC. EMBEDMENT TYP. 3000 PSI CONC. ° 6 NOTE SSI CONG. WHERE PAVERS ARE PRESENT USE 5116' bzORFIB0WWM FROM VIEW ANCHORS TO PENHEADMFGETRATE UNDERLYING OR FIBERMESH CONCRETE FOOTING 2-1/4" (MIN.) DETAIL "B" - ZX4" OR LARGER SELF MATING UPRIGHT TO DECK DETAILS SCALE: NTS ANCHORING UPRIGHT TO FOUNDATION NOTES: 1: IF PAVERS ARE PRESENT, CONCRETE ANCHORS SHALL PENETRATE INTO FOOTING 2-1 /4" MIN. (TYP.) 2.- WHEN FASTENING TO WOOD USE 1/4" GALV. LAG SCREW IN LIEU OF CONC. ANCHORS AND ENSURE 2-1/4" MIN. PENETRATION INTO STRUCTURAL FRAMING BENEATH (TYP.) 3.- NO SECONDARY ANGLE REQUIRED FOR 2X3 UPRIGHTS OR DOOR JAMBS. ROOF PER PLAN # I4x4" S.M.S. W/ 1-IM-0 FENDER WASHER AND NEO-PRENE GASKET @ 17 O.C. If 12 X 9/16" W/ 5/3" NEO-WASHER (3) PER PAN FOR PANS COVER END OF PANEL ` 3' X 2' X.OW'MIN. (SEE PLAN) ROOF PANEL TO CARRIER BEAM CONNECTION SCALE: N.T.S. FASTEN TOP OF HEADER TO INTERSECTING MEMBER W/ (4) #10 SMS (INTERNAL) 2' MIN. INTO SCREW BOSS OF INTERSECTING MEMBER 3X2 EDGE BEAM 21 #10x314*S GLE O (2) # 10 x 3/4" SMS INTO EDGE BEAM (# 10 x SMS POST (NN O ANGLELE RE UNLESS EDGE OR RED CO BEAM SPLICED OR CORNER ATTACHMENT( CORNER COLUMN SIZE PER PLAN \S,-,I:, 11111`11'1/ • \�xYxO\a� //11V �Q�`:•!V N LL O —_ LU ED 4 H P "ll1111 I IMF REVIEWED FOR CODE COMPLIANCE ST. LUCIECgOIJRIT R9 (�x1.F 2X3/ 2X4 COL. TO 2X3/ 2X4 EDGE BEAM CONNECTION SCALE: N.T.S. N340-S.M.S.w/1-1/4' Q FENDERWASHER ANDNEO-PRENE GASKET IN II-O.C. 2-X2-Xl/8- ANGLE CUT TO FIT NDER WASHER W/(3)G12a]5-EACH LEG 1'x2'XlIW ANGLE NT TO FIT 4.O.C. AND NDPRIENE GASKET 24-OC. AND NN6CAD EACH SIOF OF U PRIGHT TYP, w/p1L]5-@1-SPACING MAX. BEARING W FO0. NON{OAD BEARING WANS (4) PER LEG (MIN.) EACH SIDE TYP. ALTERNATELY CLIPS MAYBE USED 1/4'D1A TAPCON 6-FROM ENDS —� PRIMARY UPRIGHT PER PL / SIDE WALL UPRIGHT 24.O.C. MAX 1-1/4-EMBEDMENT Q PEfl PL1N INTO UNDERLYING CONC. 3 O S ALUMINUM INTERNAL OR EXTERNAL RECEIVING CHANNEL W/NI NOX>5' SSESINTO INTO GIRT OR PURUN&(2) 1141,JS ARGUE INTO BEAM OR UPWLIPSMA62ANGLE� /—I4I EWB SCREW BOSSES CLIPS M062 YBEUSED CHAIR PAIL PER PLAN 'ANGLE REQUIRED ONE SIDE DRILY WHERE KICK PLATE IS INDICATED AT CORNER AND DOOR OPENINGS FMTENW/F10X9/16'SM5 6-FROM ECRU ERS I8-INFIELD I2I RlOX1'SMSINTO SEE UPRIGHT TO DECK 1/4- DIA. TAPCON 6' FROM ENDS ORFMTENW/F8X9/1W5MS SCREW BOSSESOR CONNECTION DETAIL 14'O.C. NUX I-1/4-EMBEDMENT 2- FROM CORNERS r IN FIELD CUPS MAY BE USED INTOUNOERLYINGCONC. FOUNDATION PER PLAN SCREEN ROOM END WALL DETAIL SCALE: N.T.S. a o 0 C u�i N 2 � N TABLE 'D" BEAM QTY/ SIZE EACH SIDE 2x3 (4)/#12 2x4 (5)/#12 2x5 (5)/#12 2x6 (6)/#12 2x7 (7)/#12 2x8 1 (8)/#14 2x9 (9)/#1 4 2x 10 (9)/#14 BEAM PER PLAN (SLOPED OR FIAT) COLUMN WITHIN SMS, (EACH SIDE) QTY/ SIZE PER TABLED" POST (SEE PAGE FOR SIZE) 40TCH PROFILE MAY VARY O PERMIT CORRECT # SMS MAINTAIN MIN, OF 5/8"SEPERATION FROM EDGE OF BEAM SMS O.C. DETAIL E - UPRIGHT TO BEAM CONNECTION SCALE: NTS BEAM TO POST CONNECTION OPTION # 1 SCALE: N.T.S. PLAN POST -MAY USE: (2) 3/8'DIA. #14x3/4"SMS MACHINE BOLTS THRU QUANTITY =SEE TABLE REC. CHANNEL &POST IN LIEU OF # 14 SMS ° ° CARRIER BEAM ° 1 PER PLAN #14x3/4"SMS QUANTITY = SEE TABLE (TYP. EACH SIDE) "MAY USE: (2) 3/8' DIA. MACHINE BOLTS THRU REC. CHANNEL&BEAM IN LIEU OF #14 SMS BEAM TO COLUMN W/ RECEIVER TABLE BEAM SIZE QUANTITY/SIZE LEG TO BEAM EIS QUANTITY/SIZE TO COL. INTERNAL 2X4 (4)#12-12)#16 (8)012-(3)#I6 2X5 (5) # 12 - (3) #16 (10)#12-(3)#16 2X6 (5)912-(3)#16 (10)#12-(4)#16 2X7 (6) # 14 - (4) #16 (12)#14-(4)#16 2X8 (7) #14-(4) #16 (12) #14-(6) #16 2X9 (8)#14-IS)#16 (14)#14-(6)#16 2X10 I (9)#14-(6)#16 114J#14-(7)#16 BEAM TO COLUMN CONNECT10N DETAIL SCALE' N.T.S. #14x4"SM.S.w/1-1/4"0 FENDER WASHER AND NEOPRENE GASKET @ 12' O.C. L#12X9/16" 5/8"NEO-WASHER (3PER PAN FOR PANS ROOF PER PAN COVER END OF PANEL CARRIER BEAM CARRIER BEAM (SEE PAGE-2 (SEE PAGE-2 FOR SIZE) FOR SIZE) BEAM & BEAM TO POST CONNECTION OPTION #2 SCALE: N.T.S. •OPTIONALEXTRUDED GUTTER IS ATTACHED TO W INSULATED ROOF POST W/#12x1"6"FROM ENDS 24"O.C. POST TO CARRIER BEAM CONNECTION SCALE: N.T.S. THRU BOTTOM ' LE`'" F MAY USE: 2 3 THRU BOTTOM LEG OF () ' DIA. BOLTS APCON ANGLE INTO cork. IN LIEU OF 3/8" DIA. BOLTS (2) 3/8"DIA, EXPANSION BOLTS DIA. MACHINE (2) 3/8' DIA. MACHINE SEE NOTE # 1 THIS PAGE BOLTS w/ WASHERS BOLTS w/ WASHERS FOR BOLT PLACEMENT ® 2' FROM EDGE 2' FROM EDGE OF SLAB/ FIG. 3-3/4" FROM EGG OF SLAB/ FTG. OF SLAB/FIG. MAY USE (3) #14x1"TEK TOP VIEW TOP VIEW IN LIEU OF THRUBOLTS (2) 3/8" DIA. MACHINE PER POST BOLTS w/WASHERS (SEEPA POST PER PLAN (SEE PAGE-2 (2) 3/8" DIA. MACHINE (2) 3/8" DIA. EXPANSION BOLTS FOR SIZE) BOLTS w/ WASHERS SEE NOTE # 1 THIS PAGE 1/8Y2x3" FOR BOLT PLACEMENT �\—LfMAY USE (3) # 1 4xl " TEK (LENGTH) ANGLE IN LIEU OF THRUBOLTS (4) I/4'513-1/4"iAPCON (INTERNAL) THRU BOTTOM LEG OF 3'x3'x0.125 ANGLE ANGLE INTO CONC.� _ 3000 PSI CONIC. SLAB/FTG. 6x6-10x10 WWM x OR FIBERMESH FRONT VIEW 3"x3" POST CONNECTION DETAIL (INTERNAL BASE) SCALE: N.T.S. 3000 PSI CONIC. SLAB/ FTG. ' 6x6-1 Ox10 WWM I - - • 1 OR FIBERMESH FRONT VIEW 3"x3" POST CONNECTION DETAIL SCALE: NTS _ �C0 # / W =0:z b WIn N d�......pRo[LLJ F /////111111111\\\\\\\\ U 0 #14x4"S.M.S.w/ 1-1/4"0 EENDERWASHER AND NEO-PRENE GASKET @ 12'O.C. # 12 X 9116" W/ 5/8' NEOWASHER (3) PER PAN FOR PANS COVER END OF PANEL �-3" X 2' X .05V MIN. (SEE PLAN) ROOF PANEL TO CARRIER BEAM CONNECTION SCALE: N.T.S. REVIEWED FOH CODE COMPLIANCr- S'T. LUCIE COUN''` q n(`r MOD 91U FILE COPY