Loading...
HomeMy WebLinkAboutProduct Evaluation ReportIkBUILDING DROPS A Perfect Solution in Every Drop! Certificate of Authorization: 29578 398 East Dania Beach Blvd. Suite 338 Dania Beach, FL 33004 954.399.8478 PH 954.744.4738 FX contact@buildingdrops.com Product Evaluation Report M Silver Line Building Products Corp. V1 Series / 70 Series Single -Hung Window (2127) (Non -Impact) (HVHZ) for RFC Florida Product Approval ✓11N0 F`f'FO eS ,�,n9 4zo?o FL# FL14911 Report No. 5485 Current Florida Building Code Method: 1— D (Engineering Evaluation) Category: Windows Sub — Category: Single Hung Product: VI Series /70 Series Single Hung Window (2127) Material: PVC Product Dimensions: See Installation Instructions, SWD049 Prepared for: Silver Line Building Products Corp. One Silverline Dr. North Brunswick, N1 08902 Prepared by: Hermes F. Norero, P.E. Florida Professional Engineer # 73778 Date:01/23/2018 Contents: Evaluation Report Pages 1-3 Digitally signed by Hennes F. Norero, P.E. Reason: I am approving this document Date: 2018.02.14 14:46:24 -05'00' ES F i r,0rrr�ii 7 - a T T r 1 Gam: Al-��� Hermesf0 P.E. Florida No. 73778 1(k BUILDING DROPS A Perfect Solution in Every Dropl Certificate of Authorization: 29578 Manufacturer: Silver Line Building Products Corp. Product Category: Windows Product Sub -Category: Single Hung Compliance Method: State Product Approval Method (1)(d) FL#: FL14911 Date: 01/23/2018 Report No: 5485 Product Name: V1 Series / 70 Series Single Hung Window (2127) Scope: This is a Product Evaluation Report issued by Hermes F. Norero, P.E. (FL # 73778) for Silver Line Building Products Corp. based on Method 1d of the State of Florida Product Approval, Florida Department of Business and Professional Regulation - Florida Building Commission. Limits of Use: Hermes F. Norero, P.E. does not have nor will acquire financial interest in the company manufacturing or distributing the product or in any other entity involved in the approval process of the product named herein. This product has been evaluated for use in locations adhering to the Current Florida Building Code. See Installation Instructions SWD049, signed and sealed by Hermes F. Norero, P.E. (FL # 73778) for specific use parameters. 1. This product has been evaluated and is in compliance with the Current Florida Building Code, including the "High Velocity Hurricane Zone" (HVHZ). 2. Product anchors shall be as listed and spaced as shown on details. Anchor embedment into substrate material shall be beyond wall dressing or stucco. 3. When used in areas requiring wind borne debris protection this product complies with Chapter 16 of the Current Florida Building Code and does require an impact resistant covering. 4. Site conditions that deviate from the details of drawing SWD049 require further engineering analysis by a licensed engineer or registered architect. S. See Installation Instructions SWD049 for size and design pressure limitations. Hermes F. Norero, P.E. Florida No. 73778 Page 2 of 3 BUILDING DROPS FL#: FL14911 k Date: 01/23/2018 A Perfect Solution in Every Drop Report No: 5485 1(Certificate of Authorization: 29578 Quality Assurance: The manufacturer has demonstrated compliance of window products in Accordance with the Current Florida Building Code and State Rules for manufacturing under a quality assurance program audited by an approved quality assurance entity through Window and Door Manufacturers Association (FBC Organization #: QUA2515). Performance Standards: The product described herein has been tested per: Referenced Data: Installation: • TAS 202-94 • ASTM E330-02 • AAMA/WDMA/CSA 101/I.S.2/A440-08/11 1. Product Testing performed by Testing Evaluation Laboratories, Inc. (FBC Organization # TST4317) Report: Dated: TEL01410311 12/15/2010 Signed and Sealed by: Lyndon F. Schmidt, FL P.E. No 43409, 2. Quality Assurance Window and Door Manufacturers Association (FBC Organization #: QUA2515) 3. PVC profiles meet requirements of WDMA/HallMark WD-61 in accordance with AAMA 303 Refer to Installation Instructions (SWD049) for anchor spacing and more details of the installation requirements. Design Pressure: Refer to Installation Instructions (SWD049) for anchor spacing and more details of the installation requirements. Hermes F. Norero, P.E. Florida No. 73778 Page 3 of 3 SILVER LINE BUILDING PRODUCTS CORP. V1 SERIES170 SERIES SINGLE HUNG WINDOW (2127) (NON -IMPACT) (HVHZ) GENERAL NOTES: 1. THE PRODUCT SHOWN HEREIN IS DESIGNED AND MANUFACTURED TO COMPLY WITH THE CURRENT EDITION FLORIDA BUILDING CODE (FBC(, INCLUDING HVHZ AND HAS BEEN EVALUATED ACCORDING TO THE FOLLOWING: • TM202-94 • ASTM E33D02 • AAMA/WDMA/CSA101A.S.2/A440O8/11 2. ADEQUACY OF THE EXISTING STRUCTURAL CONCRETE/MASONRY, 2X FRAMING, AND METAL FRAMING AS A MAIN WIND FORCE RESISTING SYSTEM CAPABLE OF WITHSTANDING AND TRANSFERRING APPLIED PRODUCT LOADS TO THE FOUNDATION IS THE RESPONSIBILITY OF THE ENGINEER OR ARCHITECT OF RECORD FOR WE PROJECT OF INSTALLATION. 3. 1X AND 2X BUCKS (WHEN USED) SHALL BE DESIGNED AND ANCHORED TO PROPERLY TRANSFER ALL LOAM TO THE STRUCTURE. BUCK DESIGN AND INSTALLATION IS WE RESPONSIBILITY OFTH E ENGINEER OR ARCHITECT OF RECORD FOR THE PROJECT OF INSTALLATION. 4. THE INSTALLATION DETAILS DESCRIBED HEREIN ARE GENERIC AND MAY NOT REFLECT ACTUAL CONDITIONS FOR ASPEQFICSITE. IF SITE CONDITIONS CAUSE INSTALLATION TO DEVIATE FROM WE REQUIREMENTS DETAILED HEREIN, A LICENSED ENGINEER OR ARCHITECT SHALL PREPARE SITE SPECIFICDOMMEN FORUSEWITIUTHISDOCUMENTIN NON-HVHZAREAS.IN HVHZAXEAS, ONE TIME PRODUCT APPROVAL TO BE OBTAINED FROM MIAMI-DADE PER OR AM. S. APPROVED IMPACT PROTECTIVE SYSTEM 6 REQUIRED ON THIS PRODUCT IN AREAS REQUIRING IMPACT RESISTANCE. 6, WINDOW FRAME MATERIAL: PVC 7. IN ACCORDANCE WITH THE CURRENT EDITION FBC, WOOD COMPONENTS SHALL HAVE BEEN PRESERVATIVE TREATED OR SHALL BE OF A DURABLE SPECIES AS DEFINED IN CHAPTER 23. 8. GLASS SHALL MEETTHE REQUIREMENTS OF ASTM E 13M GLASS CHARTS. SEESHEET 1 FOR GLAZING DETAILS. MAKOVERALLSIZE CONFIG. DESIGN PRESSURE MISSILE IMPACTRATING WIDTH HEIGHT 52' 62ST O/X N62.8/-65 PSF NON IMPACT 52' 73' SIX 355/-60 PSF NON IMPACT TABLE OF CONTENTS SHEET REVISION SHEETDESCRIMON 1 . GENERAL NOTES &GLAZING DETAIL 2 - ELEVATION & ANCHOR LAYOUTS 3 - VERTICALSECTIONS 4 - HORIZONTALSECTIONS S HORIZONTAL & VERTICAL SECTIONS, INSTALLATION NOTES& REINFORCEMENT DETAILS EXTERIOR STEELSPACER 1/8" OR 3/32" SETT NG BLOCK r1 A7IAIr nlTAII wRhcaF:�sT INTERIOR MIN. GLASS SITE 7/16' NOTE: ALL GLAZING CONFIGURATIONS SHALL COMPLY WITH SAFETY GLAZING REQUIREMENTS OUTU N ED IN CURRENT FBC AND ASTM E 1300 GLASS LOAD RESISTANCE. SilverLine MAndeTsFii OHEEIIVEWxEOM/E NOMNERYNSMP. W 0®]] 9 k SJI%L�OF V: It .W! L ONW H.1d R•1 R.1b 044 ./LE R 34Yi ETR EOR. z wmvm4nRE x. am FLR: FL14911 DATE: 01 9-R I SCALE: DWG. R: I MAX. HEIGHT73" D MAX. D.LO. A HEIGHT 33.50° MM O.A FRAME IWIDTH 52° 69 A B 3 3 .0. .X. ELEVATION SINGLE NUNG WINDOW 3" MAX. FROM - CORNERS 6" MAX.- O.C. 3" MAX. FROM CORNERS ANCHOR LAYOUT NAIL FIN -SINGLE HUNG WINDOW MAX. 6.25" MAX. O.C. FROM F� CORNERS NOTE: LITASTENERS ABOVE THE MEETING RAILIN THEINTERIORIAMB TRACK MUST BE FLATHEADS. L 12.50° mm, O.C. 6.25" MAX. FROM CORNERS L T— ANCHORLAYOUT THROUGH FRAME -SINGLE HUNG WINDOW SiNerUne MAnaaiE_5i DNESIMUMDRM NORMBWmWIw.m. PN:1=2u229 m� Eq 2 � om a3 a o W m m wt i \a lAjOF Vi Cr Du c Dunn almla� m DNu anon n ms aRr. w Hnxom.Nnw N. RFDm FL R: FL14911 DATE: 01-2RAR SCALE: DWG. R: E GLAZING TAIL, SHEET 1 INTERIOR SEE GLAZING DETAIL, SHEET 1 VERTICAL SECTION 3 NAILFIN E GLAZING :TAIL. SHEET 1 INTERIOR SEE GLAZING DETAIL, SHEET 1 [gam VERTICAL SECTION 3 THRU FRAME SilverLine hMdeTsEii ONESILWWNEORM NORM ONUNSW MNORN] _ * ='9 S A OF G: O v�R s w �mR c mIDs wR >m r. ouu Rnal avu w FIDE m14 Of NINOQ.R� A]]C FL R: FL14911 DATE: 01.23.18 DWG. BY: HR FCHNH. BY:N SCALE: NTS DwG. a: S W D049 SHEET: 3 SECTS BLOCK & RAU SEE GLAZING `DETAIL SHEET 1 INTERIOR HORIZONTAL SECTION 4 UPPER SASH INTERIOR EXTERIOR — D.LO. OAK. FRAME WIDTI (per HORIZONTAL SECTION 4 LOWER SASH SEE FA 7R FORCE Silver Line mAnddsffl OMSRVDWM DPNP namxexuxivn4MIDeSDE �3 E is$ s°eE �3 0 N= Mill � � a \ *€ I;V-y * � mr. or umuR�nix w mn FL#: FL14911 DATE: m-ii-1R SCALE: ►4i MIN. DunalHAU EDGE DISTANCE BYOTHERS MIN. EMBFOMENi PERIMETER SEALANT —� 1/4"MAK� BY OTHERS SHIM SPACE MERIOR U INTERIOR 6 VERTICAL SECTION THROUGH FRAME (HEAD) iSTPAT 1/4° MAX. OTHERS SHIMSPACE INTERIOR W 0 s 2E i EMERIOR 1/4° MAX .�..II SHIMSPACE /�1 INTERIOR Y ' � BYOTHERS SCREW IN THE INTERIOR MIN. EDGE DISTANCE SCREW IN THE EXTERIOR CHANNEL PERIMETERSEALANT BY OTHERS EXTERIOR MIN. EMBEDMENT 6 HORIZONTAL SECTION THROUGH FRAME (JAMB) MIN.EMBEDT�M.ENT SUBSTRATE BY OTHERS iN 1/4" MAX. SHIMSPACE EXTERIOR a INTERIOR 6 HORIZONTAL SECTION NAZI FlN (HEAD) REINFORCEMENT DETAILS 0 83" --{ O 87" I 0.34" L—i L � 'J��I t'�j I-I�0.13" 0.77' i 0.9 I— 0.46" 0.06° 0.8]' ITERIOR OAS' OLOCK ALUMINUM OPO ALUMNUMLOCK MEETING RAIL O AAOMOMUMFi RAIL &SASH MIN. EDGE DISTANCE n HORIZONTAL SECTION VERTICAL SECTION 6 NAIL FIN(JAMB) 6 MEETINGSTIE INSTAUATIONNOTES: 1. ONE (1) INSTALLATION ANCHOR IS REQUIREDAT EACH ANCHOR LOCATION SHOWN. 2. THE NUMBER OF INSTAUATION ANCHORS DEPICTED IS THE MINIMUM NUMBER OF ANCHORS TO BE USED FOR PRODUCT INSTAUAMON OFTHE MAXIMUM SOE USTED. 3. INSTALL INDMOUAL INSTALLATION ANCHORS WITHIN A TOLERANCE OF 32/2INCH THE DEPICTED LOCATION & SPACING IN THE ANCHOR IAYOUT DETAILS II.E., WTHOUTCONSIDERATION OFTOLERANCESI. TOLERANCES ARE NOT CUMULATIVE FROM ONE INSTALLATION ANCHOR TO THE NEXT. 4. SHIM AS REQUIRED AT EACH INSTAUATION ANCHOR WITH LOAD BEARING SHIM(S).MAKIMUMALLOWABLE SHIM STACKTO BE3/8INCH. SHIM WHERE SPACE OF 1/16INCH OR GREATER OCCURS. SHIMIS) SHALL BE CONSTRUCTED OF HIGH DENSITY PLAsTICOR BmER. 5. FOR MASON BY OR CONCRETE OPENINGS,]% WOOD BUCK MAYBE USED IOPTONAL AS LONG AS THE MINIMUM EMBEDMENT AND EDGE DISTANCE REQUIREMENTS ARE STILL MET WITHIN THE CORRESPONDING HOSE SUBSTRATE. SEE GENERALNOTE N3 ON SHEET 1 FOR MORE INFORMATION. 6. MINIMUM EMBEUMENTAND EDGE OLS`FANCE EXCLUDE WALL FINISHES, INCUDING BUT NOT UNITED TO STUCCO, FOAM, BRIO( VENEER, AND SIDING. 7. INSTALLATION ANCHORS AND ASSOCIATED HARDWARE MUSTBE MADE OF CORROSION RESISTANT MATERIAL OR HAVE A CORROSION RESISTANT COATING. S. FOR HOLLOW BLOCKAND GROUT FILLED BLOCK, DO NOTINSTALL INSTALLATION ANCHORS INTO MORTAR JOINTS. EDGE DISTANCE IS MEASURED FROM FREE EDGE OF BLOCK OR EDGE OF MORTARJOINT INTO FACE SHELL OF BLOCK. 9. INSTALLATION ANCHORS SHALL BE INSTALLED IN ACCORDANCE WRN ANCHOR MANUFACTURER'S INSTALLATION INSTRUCTIONS, AND ANCHORS SHALL NOT BE USED IN SUBSTRATES WITH STRENGTHS LESS THAN THE MINIMUM STRENGTH SPECIFIED BY WE ANCHOR MANUFACTURER. 10. FOR INSTALLATION ANCHORS ABOVETHE MEETING RAIL IN TH E INTERIOR JAMB TRACK, USE FIAT HEAD ANCHORS. EXTERIOR EXFERMR�. Ix SilverLine tvAndWsEn axe mvexwePRAx NOPINB0.Ut6WIC(N10090i 4SA rKLNG` InbddlL£Fp4AJac �o PRaPs xc .9CLdVM NAW SW./].V OW1 WIOT R ]]Zl fB£ SFf. S IIIIIYRANPI xn Aafe FL p: FL14911 DATE: 01.23.18 DwGHR DHKHFN Sw : NTS DWG.#: SWD049 SHEET: 5