Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Construction Plans
ADDITION WkIl SECTION SCALE''/4" FGR. HOME WALL SECTION SCALE''/4" `1�Y%12GAi1�`_ MIN. FRONT SIDES_ CNR S: REAR_ TECH. A7unoo a o 7uauiUetla0 5u a Woad 0U1 g 0 Nnr Oan>Ijja REQ. ULTIMATE PROTECTION FOR MASONRY. Loxon XP" provides exceptional protection The jobs go fast and the great look lasts a long against wind -driven rain, alkali and efflorescence. time. Protect concrete from damp conditionsµ This direct -to -concrete and masonry high -build ° and weathering, plus meet the most sMngent — — coating offers maximum performance in one less M9 VOC regulations. coat compared to conventional coatings. Can be applied over high pH (up to 13) substrates. / r , �' / F 9 • Exceptional flexibility, durability and fade resistance. • Delivers excellent directional rolling and sheen for a uniform finish. L. • Protects against wind -driven rain, alkali, cracking and efflorescence. • Meets the most stringent VOC regulations. ) to +v q • High build for one less coat compared to conventional • Low temperature application down to 35'F. masonry coatings. • Save time and turn jobs fast— applies directly to bare concrete with • Suitable for all types of vertical concrete and masonry surfaces �c' is , a pH as high as 13, Can be applied to fresh concrete and masonry less including tilt -up, precast, poured -in -place, CM11, cement block than 28 days old. No primer needed. and stucco. Available in a wide range of colors. • For best results, this product should be applied at a minimum of 14-18 mils WFT (wet film thickness) and 6.5-8.4 DFT (dry film thickness). - 3 0 ' SCALE Iva JW 1�� Ji ADDITION : MANUFACTURED HOME <It W/ 2X4 STUDS @ 16" O.C. W/ 2X4 STUDS @ 16"O.C. i Q A 1 ti6 LATH & STUCCO DETAILS: Q�fi`4 ALL LATH AND LATH ATTACHMENTS TO BE CORROSION -RESISTANT 3/8" RIB WIRE LATH ATTACHED WITH ROOFING NAILS WITH MIN. 1%" PENETRATION IN HORIZ. FRAMING & %" IN VERT. FRAMING MEMBERS. NAILS @ 6 o.c. OR 16 GAGE STAPLES ON FRAMING MEMBERS. STUCCO TO BE (2) COATS 7/8" THICK �G©p`II �� FBC 2017 (6t" ECITIOF«? � ,SCE 7-10• DESIGN CRITERIA: RISK CATAGORY 11 ULTIMATE WIND SPEED 165 MPH NOMINAL WIND SPEED 128 MPH IMPORTANCE FACTOR 1.0 BUILDING DESIGN ENCLOSED WIND EXPOSURE D INTERNAL PRESSURE COEF. +/_ 0.18 DESIGN PRESSURES: ROOF UPLIFT -38.55 PSF WINDOW/DOOR (INT. ZONE) +43.41-47.2 PSF GENERAL NOTES: 1. THE OWNER STARTED TO STUCCO THE EXTERIOR OF HIS MANUFACTURED HOME AND ADDITION WITHOUT A BUILDING PERMIT. 2. AT THE CURRENT TIME HE HAS WRAPPED THE EXISTING PLYWOOD SHEATHING WITH "TYVEK" AND APPLIED WIRE LATH WITH STUCCO BROWN COAT. 3. IN ORDER TO ACHIEVE (2) MOISTURE LAYERS PER THE CODE, THE BROWN COAT MUST BECOME WATERPROOF, TO PROVIDE THE SECOND LAYER. 4. A PENETRATING WATERPROOFING "LOXON XP" BY SHERWIN WILLIAMS TO BE APPLIED PRIOR TO THE FINAL COAT -OF STUCCO. 5. CAULK WHERE NECESSARY. 6. ALL WORK DONE IN ACCORDANCE WITH 2O17 FBC (6th EDITION). eSlll by: Vturcy�//i�� RICHARD A. JEMISON Nsay,� P.O. Box 5616 _ a ' o oaaa Ft. Pierce, FE. 34954 LU (772) 215-5623 �'•, TQT 2 BENCHMARK ENGINEE OF THE TREASURE COAST //If, �ONA\����� 806 DELAWARE AVE. FT. PIERCE, FL. 34950 (772) 772-267.1399 06/01120 SEAL STUCCO OVER SHEET EXISTING SIDING MIKE FRANCIONE BOWDOIN 10851 S. OCEAN DR. (LOT #159) P.E. #70878 JENSEN BEACH, FLORIDA OF 1