HomeMy WebLinkAboutProduct approval, windows Florida Building Code Online Page 1 of 3
[1t
BCIS Home Log In 's User Registration I Hot Topic I Submit Surcharge I Stats&Facts ? Publications I Contact Us SCIS Site Map I Links I Search
Florida
1t QD
Product Approval
USER:Public User
r, rCi kr cs
E-M�u=Sr�l�lcm '
Product Aooroval Menu>Product or Application Search>Application List>Appiication Detail
FL# FL14911-R11
Application Type Revision
Code Version 2017
Application Status Approved
i
Comments
Archived ❑
Product Manufacturer Silver Line Building Products Corp.
Address/Phone/Email One Silverline Drive
North Brunswick,NJ 08902
(732)435-1000
jonberrian@slbp.com
Authorized Signature Jon Berrian
jonberrian@sibp.com
Technical Representative Jon Berrian
Address/Phone/Email One Silverline Drive
North Brunswick,NJ 08902
(732)435-1000
jonberrian@slbp.com
Quality Assurance Representative
Address/Phone/Email
Category Windows
Subcategory Single Hung
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed
Florida Professional Engineer
❑ Evaluation Report-Hardcopy Received
Florida Engineer or Architect Name who developed Hermes F.Norero,P.E.
the Evaluation Report
Florida License PE-73778
Quality Assurance Entity Window and Door Manufacturers Association-QA
Quality Assurance Contract Expiration Date 08/03/2021
Validated By Locke Bowden P.E.
Wd Validation Checklist-Hardcopy Received
Certificate of Independence FL14911 R11 COI COI Silverline SS 2017-06-14 odf
Referenced Standard and Year(of Standard) Standard Year
AAMA/W DMA/CSA/101/I.S.2/A440 2008
AAMA/W DMA/CSA/101/I.S.2/A440 2011
ASTM E1886 2005
ASTM E1996 2006
ASTM E1996 2009
ASTM E1996 2012
ASTM E330 2002
TAS 201 1994
TAS 202 1994
TAS 203 1994
https://www.floridabuilding-org/pr/pr_app_dtl.aspx?param=wGEVXQwtDquZRj 59%2fDr... 6/26/2020
Florida Building Code Online Page 2 of-3
Equivalence of.Product Standards
Certified By
Sections from the Code
I
Product Approval Method Method 1 Option D
Date Submitted 08/17/2018
Date Validated 10/14/2018
Date Pending FBC Approval 10/08/2018
Date Approved 10/18/2018
Summary of Products
FL# Model,Number or Name Description
14911.1 Vl Series/50 Series(2000) Single-Hung Window
Limits of Use Installation Instructions
Approved for use in HVHZ:No FL14911 Rll II SWD017 SS 2018-10-11.odf
Approved for use outside HVHZ:Yes Verified By: Hermes F. Norero, P.E.Florida P.E.73778
Impact Resistant:No Created by Independent Third Party:Yes
Design Pressure:N/A Evaluation Reports
Other:See Installation Instructions and Product Evaluation FL14911 R11 AE PER5140 SS 2017-10-20.odf
Report for allowable design pressures,sizes,installation Created by Independent Third Party:Yes
requirements and limits of use.
14911.2 Vl Series/50 Series(2111) Single-Hung Window
Limits of Use Installation Instructions
Approved for use in HVHZ:No FL14911 R11 II SWD018 SS 2018-10-11.ndf
Approved for use outside HVHZ:Yes Verified By: Hermes F. Norero,P.E. Florida P.E.73778
Impact Resistant:No Created by Independent Third Party:Yes
Design Pressure:N/A Evaluation Reports
Other:See Installation Instructions and Product Evaluation FL14911 R11 AE PER5141 SS 2017-10-20.odf
Report for allowable design pressures,sizes,installation Created by Independent Third Party:Yes
requirements and limits of use.
14911.3 Vl Series/50 Series(2200/2300) Single-Hung Window
Limits of Use Installation Instructions
Approved for use in HVHZ:No FL14911 R11 II SWD019 SS 2018-10-11.odf
Approved for use outside HVHZ:Yes Verified By: Hermes F. Norero,P.E. Florida P.E.73778
Impact Resistant:No Created by Independent Third Party:Yes
Design Pressure:N/A Evaluation Reports
Other:See Installation Instructions and Product Evaluation FL14911 R11 AE PERS142 SS 2017-10-20.odf
Report for allowable design pressures,sizes,installation Created by Independent Third Party:Yes
requirements and limits of use.
14911.4 Vl Series/70 Series(2127) Single-Hung Window
Limits of Use Installation Instructions
Approved for use in HVHZ:Yes FL14911 R11 II SWD049 SS 2018-10-1l.odf
Approved,for use outside HVHZ:Yes Verified By: Hermes F. Norero,P.E.Florida P.E.73778
Impact Resistant:No Created by Independent Third Party:Yes
Design Pressure:N/A Evaluation Reports
Other:See Installation Instructions and Product Evaluation FL14911 Ril AE PER5485 SS 2018-02-14.odf
Report for allowable design pressures,sizes,installation Created by Independent Third Party:Yes
requirements and limits of use.
14911.5 V1 Series/70 Series(2127) Single-Hung Window
Limits of Use Installation Instructions
Approved for use in HVHZ:Yes FL14911 Rll II SWD050 SS 2018-10-li.odf
Approved for use outside HVHZ:Yes Verified By: Hermes F.Norero,P.E.Florida P.E.73778
Impact Resistant:Yes Created by Independent Third Party:Yes
Design Pressure:N/A Evaluation Reports
Other:See Installation Instructions and Product Evaluation FL14911 R11 AE PER5486 SS 2018-04-19.odf
Report for allowable design pressures,sizes,installation Created by Independent Third Party:Yes
requirements and limits of use.
14911.6 V1 Series/70 Series(2907/4907) Single-Hung Window
Limits of Use Installation Instructions
Approved for use in HVHZ:No FL14911 R11 II SWD053 SS 2018-10-11.odf
Approved for use outside HVHZ:Yes Verified By: Hermes F. Norero,P.E.Florida P.E.73778
Impact Resistant:No Created by Independent Third Party:Yes
Design Pressure:N/A Evaluation Reports
Other:See Installation Instructions and Product Evaluation
https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDquZRi 59%2fDr... 6/26/2020
1
Florida Building Code Online Page 3 of 3
Report for allowable design pressures,sizes,installation I FL14911 R11 AE PER5884 SS 2018-08-17.0f
requirements and limits of use. Created by Independent Third Party:Yes
i
Back Nexi
Contact Us::2601 Blair Stone Road.Tallahassee FL 32399 Phone:850-487-1824
The State of Florida is an AA/EEO employer.Copyright 2007-2013 State of Florida ::Privacy Statement::Accessibility Statement::Refund Statement
Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do not send electronic
mail to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395.-Pursuant to Section 455.275
(1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if they have one.The
emalis provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address,
please provide the Department with an email address which can be made available to the public.To determine if you are a licensee under Chapter 455,F.S.,please
click here.
Product Approval Accepts:
Credit Card
Safe
i
https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDquZRj 59%2fDr... 6/26/2020
Silver
SILVER LINE WINDOWS AND DOORS
V1 SERIES/50 SERIES
SINGLE HUNG WINDOWS (2111) ONESBVERUN
NORTH BRUNSWICK,W 08903
PX:1800 236-0]18-4228
GENERAL NOTES:
O o e
1. THE PRODUCT SHOWN HEREIN IS DESIGNED AND
MANUFACTURED TO COMPLY WITH THE CURRENT EDITION h O
FLORIDA BUILDING CODE(FBC),EXCLUDING HVHZ AND HAS 2 z i m T
BEEN EVALUATED ACCORDING TO THE FOLLOWING: h 3 m
;? • AAMA/WDMA/CSA 101/I.S.2/A440-110
w
W W Q
a 2.ADEQUACY OF THE EXISTING STRUCTURAL TABLE OF CONTENTS r ti W
CONCRETE/MASONRY,2X FRAMING,AND METAL FRAMING r a
AS A MAIN WIND FORCE RESISTING SYSTEM CAPABLE OF SHEET REVISION SHEET DESCRIPTION
WITHSTANDING AND TRANSFERRING APPLIED PRODUCT REMARKS BY DATE
LOADS TO THE FOUNDATION IS THE RESPONSIBILITY OF THE 1 - GENERAL NOTES&GLAZING DETAILS 6TH FBC EDITION FM 10/17
ENGINEER OR ARCHITECT OF RECORD FOR THE PROJECT OF 2 - ELEVATIONS&ANCHOR LAYOUTS
INSTALLATION.
3 - VERTICAL SECTIONS
3.1X AND 2X BUCKS(WHEN USED)SHALL BE DESIGNED AND
ANCHORED To PROPERLY TRANSFER ALL LOADS TO THE 4 - HORIZONTAL SECTIONS
TxE iNSTAWnON DETAIEF—11"1111N APF OFNERK
STRUCTURE.BUCK DESIGN AND INSTALLATION IS THE 5 - ANCHOR DETAIL&SCHEDULE AND NMY NOTREF—A—AL-11IONS FORA SRE
RESPONSIBILITY OF THE ENGINEER OR ARCHITECT OF RECORD R orn TRx'T oDNanoxsuusE usruunoxToocvuTE
E REaDIREMENrsDETA MHEREKAEICEREED
INEERORAR
ENGCHDECTFxALLRREPARESRESREAFIC
FOR THE PROTECT OF INSTALLATION. Docu.—FORu WRHMS—MENT.
4.THE INSTALLATION DETAILS DESCRIBED HEREIN ARE GENERIC Digitally signEQ IHE1rhJdrifTNorero,P.E
'- AND MAY NOT REFLECT ACTUAL CONDITIONS FOR A SPECIFIC Reason-QX 's a6fyrjlant
(, SITE.IF SITE CONDITIONS CAUSE INSTALLATION TO DEVIATE Date, 8 .33.
FROM THE REQUIREMENTS DETAILED HEREIN,A LICENSED
ENGINEER OR ARCHITECT SHALL PREPARE SITE SPECIFIC `� ;'��)•E S• ••'Pp moi=
DOCUMENTS FOR USE WITH THIS DOCUMENT IN NON-HVHZ a N 7 7
AREAS.
5/8"O.A.
5. APPROVED IMPACT PROTECTIVE SYSTEM IS REQUIRED ONS A OF
THIS PRODUCT IN AREAS REQUIRING IMPACT RESISTANCE. - ��OT IDP;•• Y!/�`
EXTERIOR INTERIOR
6. WINDOW FRAME MATERIAL:PVC
3
7.GLASS SHALL M EET THE REQUIREMENTS OF ASTM E 1300 7/ �D4RELlxLai
GLASS CHARTS.SEE SHEET 1 FOR GLAZING DETAILS. rEaRnA P.E HD tine
EiULOIN DROPS.PEC
D98 E DANIA BEACH MW./3]a
o"a'BEACH,rL]300+
iHPE CERT.of AUTHORRATIOX Ha"S.
DESIGN PRESSURE TABLE FL#:
r^L1 4^1 w
; SIZE CONFIGURATION DESIGN PRESSURE MISSILE IMPACT RATING y 1
DATE: 09.20.17
F0 DWG.BY: CHK.B
36.0"X 62.0" O/X +50/-50 PSF NON-IMPACT �„{FN
1/2FI CL.MIN.GLASS l
+40/-40 PSF NON-IMPAR BITE GLAZING DETAIL DWGEa' NTS
as.o°x 6z.o" o/x S W D 018
52.0"X 13.0" O/X +30/-30 PSF NON-IMPARSHEET:
GLAZING NOTE:
• GLASS THICKNESS AND TYPE SHALL {�
COMPLY WITH ASTM E-1300 GLASS u
CHARTS REQUIREMENT
OF 4
Silver Line
byAna
ONE MWERUNEDRNE
NORTH BRUNSWICK,N1 08902
UNIT MAX. PN:800:34-4228
WIDTH 52.0E-4N z
r
D.L.O MAX. - o a"
�-
WIDTH 47.69" 0cd
c , Z".--
2
W h Z Z z g d
�3
A 6.011 FROM o N a 3
3 CORNER(TYP.) rL Q? o
F EY W
f � 6
14.00"MAX• REMARKS 8Y DATE
011 4 D HEIGHT 6TH OII (NP) 6TH FBC EDITION FM 10/17
UNIT 33.50"
MAX. 3.0"(TYP.)
HEIGHT NE INSAM DxD A—DEDxEREa.REGENRK
AND NUY NOTRE[IECT ACNAICONDDI0N5[p1ANEa[IC
73.0" FROM TME CONOR E'NStlDSEINUDHETONTOOEWTE
FROM THE REQUMFNENTR OETAIIED NERnx,ANC 90
ENGINEER ORARCNPFSN2RPIDARESIIERRF(1[K
DO[UMENTR[ORO TNISDOOIME
3.011(TYP.)
A 11 � �
;? X1, %%%
IIXII ��
r 4 _
s OF rD
6.011 FROM O VOP:c.<v�`?
s CORNER(TYP.) graL dE��`•
ANCHOR LAYOUT RDR DA PE N4 7J77e
ELEVATION THROUGH FRAME >sBED BCH.FL MOM 0 f 33a
DAa BEACH,R m.
iH MT.OF AUTg1eZA N,39573
FL M:
FL14911
DATE: 09.20,17
DWG.BY: CHK.BY:
CL HFN
SCALE: NTS
DWG.u: SWD018
SHEET:
OF 4
Silver Line
brAndFdR
E8'
ONE SILVERNNE DRIVE
NORTH BRUNSWICK, 08902
PH:800 I8A-022228
O SEE GLAZING z
SHEET 1 2
A� o1 3
C3
_� zmgaa
o
co ;
m
o
W � W <0
O I REMARKS BY DATE
6TH FBC EDITION FM 10/17
t Q
VERTICAL SECTION = EXTERIOR INTERIOR
3 �
Q NOT REFUCAN5uF5WeEFIIONS FORA
OGENfNC
z xnwuv xar aEfFERARNAEeoxomoxs foaasafafK
z X O vrf.If v REWI MENTS f lxsru IMIA—...
'4 Q f_tNEE RMARCMFNRM
ENGINEER OR aR[NITERSHALLRRFRA0.FSRF SRELLEK
HNI l6E w1
` V\. ,AO
R N_. 7 7
SEE GLAZING S A OF
fSHEET 1
i�pT O IDp
OL
P Y0No 737 c
FLORIDAOP.E.Na ZINC
B11 BEAcRoCH
INC
89e E E BEACH BLVD./J]8
DANIA EIEACH,ii]]00!
f13PE mfr,a wnwwunaN Na nsre
FL a:
FL14911
O DATE: 09.20.17
DWG.BY: CHK.BY:
OO CL HFN
SCALE: NTS
DWG.it: SWD018
SHEET:
ry
a
u��J� OF 4
Silver Line
MMd63Fh
ONE SILVERUNE DRNE
NORTH BRUNSWIQ,M 08902
PH:800 230-0278
o
-� - Mme $_ - -
n` (D
Z O
FWi1 OO O ai
Z m
3 O m //
_ \a
`• 0 INTERIOR 0 Rs
SEE GLAZING SEE GLAZING
DETAIL SHEET I DETAILSHEETl r a
REMARKS BY DATE
6TH FBC EDITION FM 10/17
p
O� aSlA WTIDx DETAILSDfG@IBED NEREw ARE DExfRK
AND MA
Q� TXE IN TxOi R[CIECIACTUAl O>xgDM6 FgtA5FLCPK
SOF.MTM REQUIRE 5 MMILTAWTON TO DE 90
I` RARM USHALLPRE FREM,A PEO'.D
FFNGINF[RO0. OREwONPRE5�D0NMCNTOCR:
L CO[uMF
EXTERIOR
``,
o ��� .�
O 00 ; ;10
-N 7
D.L.O.
A OF
MAX.FRAME WIDTH i 01" O IOP•' �/
3 i��''�SS
x b1 Y"EttOZ*
- M.WA PE ND 7377°
BULLDNG DROPS,NO
HORIZONTAL SECTION � HORIZONTAL SECTION CI�.AU ���"°
2 FSE GTFf. A WTH0E0lA3 Na 29578
OPERABLEJAMB 4, FIXEDJAMB FL#:
FL14911
DATE: 09.20.17
gDWG.BBL CHK.B
SCALE: NTS
r, DWG.It: SWD018
SHEET:
.f
0F 4
MIN.EDGE DISTANCE Silver Line
SUBSTRATE BY OTHERS �Mderseri
--�I 3/8"MAX.SHIM SPACE
SUBSTRATE BY OTHERS
0
INTERIOR
ONE SINE URWE
NORM BRUNSWICK,W 06903
MIN.EMB. TO BE INSTALLED PH:IBM 1344228
ABOVE MEETING RAIL
TO BE INSTALLED ? I„ z�
3/8"MAX. BELOW MEETING RAIL Ey v1m m S
SHIM SPACE o 2 _ o Q
MIN.
EXTERIOR INTERIOR EDGE DISTANCE EXTERIOR w h Z m
5 Ti
ul MIN.EMB. 22 3 a Es
EWif
ANCHOR DETAIL ANCHOR DETAIL �3 z o m T
5 THROUGH FRAME(HEAD) 5 THROUGH FRAME(JAMB) W a w
W N d \
Pf ti
REMARKS BY DATE
ANCHOR SCHEDULE 6TH FBC EDITION FM 10/17
METHOD SUBSTRATE ANCHOR SCHEDULE MIN EMBEDMENT MIN.EDGE
DISTANCE
WOOD:MIN.SG=0.55 #10 WOOD SCREW 1.5• 0.75°
3 THREADS MIN EIN:i,NA„ON OEIAR:OEE�IaEONEREINARE GENERIC
METAL:18 GAUGE OT RFfIECTA[NNECONDrt10 =—EUBG
#10 TEK SCREW PENETRATION BEYOND 0.75" ii lvi"EmNnmMSM ERNn.uanONTOGEvwIE
Steel,MIN.Fy=33KSI OM1NEnrOU�REMEN 0-1 HUREIN.AE¢FN40
INSTALLATION NOTES: THROUGH FRAME METAL ENGINEER ORAROIIlERSNALLYRERMESIlF5VF0iIC
CONCRETE: 3/16'ITWTAPCON 1" 25° OOE„ME`,j1111r;/'OOE,EMEM.
1. ONE(1)INSTALLATION ANCHOR IS REQUIRED AT EACH ANCHOR LOCATION SHOWN, fc=2000PSI
MASONRY:CMU per3/16'ITW TAPCON 1' 2.5' ����` E F' 0
2. THE NUMBER OF INSTALLATION ANCHORS DEPICTED IS THE MINIMUM NUMBER OF ANCHORSTO BE USED ASTM C90
FOR PRODUCT INSTALLATION OF THE MAXIMUM SIZE LISTED. +� •E••S 'Ao
N 7 7
3. INSTALL INDIVIDUAL INSTALLATION ANCHORS WITHIN A TOLERANCE OF±1/2INCH THE DEPICTED LOCATION NOTE:
&SPACING IN THE ANCHOR LAYOUT DETAILS(I.E.,WITHOUT CONSIDERATION OF TOLERANCES). 1. LOCATION OF BUCK OR WINDOW ANCHORS MAY BE
- TOLERANCES ARE NOT CUMULATIVE FROM ONE INSTALLATION ANCHOR TO THE NEXT. ADJUSTED TO MAINTAIN 1"MIN.CENTER TO CENTER S A OF
SPACING BETWEEN ANCHORS SUCH THAT MAX.O.C. Op 0 IOP- �41i�
4. SHIM AS REQUIRED AT EACH INSTALLATION ANCHOR WITH LOAD BEARING SHIM(S). MAXIMUM SPACING SPECIFIED IS NOT EXCEEDED. �i�(ns, •G\����
ALLOWABLE SHIM STACK TO BE 1/4 INCH.SHIM WHERE SPACE OF 1/16 INCH OR GREATER OCCURS. 2. BUCK MAY BE FLUSH WITH FACE OF THE BLOCK. �i� S 0 EN ���
SHIM(S)SHALL BE CONSTRUCTED OF HIGH DENSITY PLASTIC OR BETTER. /�� 11
- 1/4"ITW TAPCON ANCHOR xElbtA P poN.73na
OA P
ROWE 3E 10 19
S. MINIMUM EMBEDMENT AND EDGE DISTANCE EXCLUDE WALL FINISHES,INCLUDING BUT NOT LIMITED TO 4"FROM CORNERS8V4DPB."O OROwO
M E 11 N BEA OI BWO.0 aOa
STUCCO,FOAM,BRICK VENEER,AND SIDING. 16"MAX.O.C.THEREAFTER OAru Ea:1Ea.n OOEro4
2X WOOD BUCK OF SUFFICIENT RBPE Exnr.OF wlxawrAnaE W.rima
- 6. INSTALLATION ANCHORS AND ASSOCIATED HARDWARE MUST BE MADE OF CORROSION RESISTANT DEPTH TO FULLY SUPPORT FL#:
- MATERIAL OR HAVE A CORROSION RESISTANT COATING. WINDOW FRAME. I �/�
4
BY OTHERS `
's 911
7 ON ANCHORS INTO MORTAR I-
JOINTSS..LED E DISTANCE IS MEASURED LOW BLOCK AND GROUT DFROM REE EDGE OF BBLOCK,DO NOT LOCK ORE GELL IOF MORTAR JOINT INTO FACE 11/4"MIN. .. .. DATE: 09.20.17
SHELL OF BLOCK. EMBEDMENT 11/2 MIN.EDGE DWG.BY: CHK.BY:
° DISTANCE CL HFN
8. INSTALLATION ANCHORS SHALL BE INSTALLED IN ACCORDANCE WITH ANCHOR MANUFACTURER'S '�'
INSTALLATION INSTRUCTIONS,AND ANCHORS SHALL NOT BE USED IN SUBSTRATES WITH STRENGTHS LESS SCALE: NTS
THAN THE MINIMUM STRENGTH SPECIFIED BY THE ANCHOR MANUFACTURER. 2"MIN.EDGE DWG.#:
-
DISTANCE • o. * CONCRETE/MASONRY SWD018
BY OTHERS SHEET:
BUCK INSTALLATION DETAIL G�
OF 4