Loading...
HomeMy WebLinkAboutRevision form , Energy calcsOFFICE USE ONLY: DATE FILED: REVISION FEE: PERMIT # 1910-0530 RECEIPT # PLANNING & DEVELOPMENT SERVICES BUILDING & CODE REGULATION DIVISION 2300 VIRGINIA AVENUE FORT PIERCE, FL 34982-5652 (772) 462-1553 APPLICATION FOR BUILDING PERMIT REVISIONS PROJECT INFORMATION LOCATION/SITE ADDRESS: 1313 Ione pine drive, fort pierce, fla. DETAILED DESCRIPTION OF PROJECT REVISIONS: REVISED ENERGY CODE TO REFLECT GLASS INSERTS IN THE FRONT DOOR CONTRACTOR INFORMATION: STATE of FL REG./CERT. #: crc036620 BUSINESS NAME: GEM BUILDERS, INC QUALIFIERS NAME: SUSAN BARBER ADDRESS: 1321 LONE PINE DRIVE CITY: FORT PIERCE STATE: FLA. PHONE (DAYTIME): 772-201-8434 OWNER/BUILDER INFORMATION: NAME: NOT APPLICABLE ADDRESS: CITY: PHONE (DAYTIME: STATE: ARCHITECT/ENGINEER INFORMATION: NAME: RAUL R. VALELLA ADDRESS: 138 SE NARANJA AVENUE CITY: PORT ST LUCIE PHONE (DAYTIME): 772-871-2457 SLCCC: 9/23/09 Revised 06/30/17 ST. LUCIE CO CERT. #: ZIP: 34982 FAX: NONE ZIP: FAX: STATE: FLA. ZIP: 34952 FAX: NONE EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 86/25/2020 9:19 PM Project Name: Owner: Builder Name: Permit Office: Jurisdiction: ST LUCIE COUNTY ST LUCIE COUNTY GEM BUILDERS WILLIAM AND DANA TILLBERG TILLBERG RESIDENCE Street: City, State, Zip: FORT PIERCE , FL , 1313 LONE PINE DRIVE Permit Number: Design Location: FL, Fort Pierce County: St. Lucie (Florida Climate Zone 2 ) 1. New construction or existing 2. Single family or multiple family 3. Number of units, if multiple family 4. Number of Bedrooms 5. Is this a worst case? 6. Conditioned floor area above grade (ft²) New (From Plans) Single-family 1 No 2778 7. Windows a. U-Factor: S H G C : b. U-Factor: S H G C : c. U-Factor: S H G C : d. U-Factor: S H G C : Sgl, U=0.55 471.04 ft² SHGC=0.22 N/A f t ² N/A f t ² N/A f t ² 8. Floor Types a. Slab-On-Grade Edge Insulation b. N/A c. N/A R=0.0 2778.00 ft² R=f t ² R=f t ² 9. Wall Types a. Concrete Block - Int Insul, Exterior R=5.0 2654.80 ft² b. Frame - Wood, Adjacent R=11.0 290.00 ft² c. N/A R=f t ² 10. Ceiling Types a. Roof Deck (Unvented)R=20.0 2778.00 ft² f t ² R=b. N/A c. N/A R = f t ² 11. Ducts a. Sup: Attic, Ret: Attic, AH: AHU CLST 12. Cooling systems 13. Heating systems 14. Hot water systems a. Electric Cap: 50 gallons b. Conservation features None d. N/A R=f t ² Area Weighted Average Overhang Depth:6.202 ft. Area Weighted Average SHGC:0.220 Description Area Insulation Area Insulation Area Insulation Area 15. Credits None 4 (471.0 sqft.) (2944.8 sqft.) (2778.0 sqft.) (2778.0 sqft.) Conditioned floor area below grade (ft²) 0 a. Central Unit a. Electric Strip Heat k B t u / h r 46.5 SEER:16.00 Efficiency k B t u / h r Efficiency 34.0 COP:1.00 f t ² R 6 200 EF: 0.980 Glass/Floor Area: 0.170 Total Proposed Modified Loads: Total Baseline Loads: 95.00 95.36 PASS I hereby certify that the plans and specifications covered by this calculation are in compliance with the Florida Energy Code. PREPARED BY: DATE: I hereby certify that this building, as designed, is in compliance with the Florida Energy Code. OWNER/AGENT: DATE: BUILDING OFFICIAL: DATE: Review of the plans and specifications covered by this calculation indicates compliance with the Florida Energy Code. Before construction is completed this building will be inspected for compliance with Section 553.908 Florida Statutes. - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory-sealed in accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2). FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method FORM R405-2017 6-25-2020 PROJECT Title: Owner Name: # of Units: Builder Name: Permit Office: Jurisdiction: ST LUCIE COUNTY ST LUCIE COUNTY GEM BUILDERS 1 WILLIAM AND DANA TILLBE TILLBERG RESIDENCE Family Type: New/Existing: Bedrooms: Conditioned Area: Total Stories: Worst Case: Rotate Angle:0 No 1 2778 4 New (From Plans) Single-family Address Type: Lot # Block/Subdivision: PlatBook: Street: County: City, State, Zip: FL , FORT PIERCE , St. Lucie 1313 LONE PINE DRIV Street Address Comment: Building Type: User Cross Ventilation:No Whole House Fan:No TMY Site Design Temp Int Design Temp Heating Design Daily Temp Design Location 2.5 %97.5 %Degree Days Moisture RangeWinter Summer CLIMATE 90 70 75 299 62 Low39FL_VERO_BEACH_MUNIFL, Fort Pierce______ Number Name Area Volume BLOCKS 1 Entire House 2778 28500 Number Name Area Volume SPACES Kitchen Occupants Bedrooms Cooled HeatedInfil ID Finished 1 BEDROOM 4 156 1560 No 0 1 Yes Yes1 Yes 2 CLST 4 18 180 No 0 Yes Yes1 Yes 3 BATH 3 54 540 No 0 Yes Yes1 Yes 4 BEDROOM 3 132 1320 No 0 1 Yes Yes1 Yes 5 CLST 3 16 160 No 0 Yes Yes1 Yes 6 BATH 2 64 640 No 0 Yes Yes1 Yes 7 BEDROOM 2 140 1400 No 0 1 Yes Yes1 Yes 8 CLST 2 16 160 No 0 Yes Yes1 Yes 9 MUD ROOM 105 1050 No 0 Yes Yes1 No 10 AHU CLST 12 120 No 0 Yes Yes1 No 11 DINING 156 1560 No 0 Yes Yes1 Yes 12 FOYER 94 940 No 0 Yes Yes1 Yes 13 KITCHEN 358 3580 Yes 0 Yes Yes1 Yes 14 LIVING ROOM 202 2222 No 0 Yes Yes1 Yes 15 FAMILY ROOM 247 2717 No 0 Yes Yes1 Yes 16 HALL 32 320 No 0 Yes Yes1 No 17 HALL 2 40 400 No 0 Yes Yes1 No 18 MASTER BEDROO 271 2981 No 0 1 Yes Yes1 Yes 19 M WIC 1 49 490 No 0 Yes Yes1 Yes 20 M WIC 2 54 540 No 0 Yes Yes1 No 21 M BATH 234 2340 No 0 Yes Yes1 Yes 22 M TOILET 20 200 No 0 Yes Yes1 Yes 6/25/2020 9:19 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 2 of 8 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT Number Name Area Volume SPACES Kitchen Occupants Bedrooms Cooled HeatedInfil ID Finished 23 W/D 24 240 No 0 Yes Yes1 No 24 POWDER RM 36 360 No 0 Yes Yes1 Yes 25 GAME ROOM 248 2480 No 0 Yes Yes1 Yes # Floor Type Area Tile Wood Carpet FLOORS Perimeter R-Value Joist R-ValueSpace Perimeter 1 156 ft² 1 0 0______ Slab-On-Grade Edge Insulation - - - -025 ft BEDROOM 4 2 18 ft² 1 0 0______ Slab-On-Grade Edge Insulation - - - -02 ft CLST 4 3 54 ft² 1 0 0______ Slab-On-Grade Edge Insulation - - - -06 ft BATH 3 4 132 ft² 1 0 0______ Slab-On-Grade Edge Insulation - - - -011 ft BEDROOM 3 5 16 ft² 1 0 0______ Slab-On-Grade Edge Insulation - - - -02 ft CLST 3 6 64 ft² 1 0 0______ Slab-On-Grade Edge Insulation - - - -08 ft BATH 2 7 140 ft² 1 0 0______ Slab-On-Grade Edge Insulation - - - -011 ft BEDROOM 2 8 16 ft² 1 0 0______ Slab-On-Grade Edge Insulation - - - -02 ft CLST 2 9 105 ft² 1 0 0______ Slab-On-Grade Edge Insulation - - - -01 ft MUD ROOM 10 12 ft² 1 0 0______ Slab-On-Grade Edge Insulation - - - -01 ft AHU CLST 11 156 ft² 1 0 0______ Slab-On-Grade Edge Insulation - - - -014 ft DINING 12 94 ft² 1 0 0______ Slab-On-Grade Edge Insulation - - - -09 ft FOYER 13 358 ft² 1 0 0______ Slab-On-Grade Edge Insulation - - - -014 ft KITCHEN 14 202 ft² 1 0 0______ Slab-On-Grade Edge Insulation - - - -011 ft LIVING ROOM 15 247 ft² 1 0 0______ Slab-On-Grade Edge Insulation - - - -014 ft FAMILY ROOM 16 32 ft² 1 0 0______ Slab-On-Grade Edge Insulation - - - -01 ft HALL 17 40 ft² 1 0 0______ Slab-On-Grade Edge Insulation - - - -01 ft HALL 2 18 271 ft² 1 0 0______ Slab-On-Grade Edge Insulation - - - -027.2 ft MASTER BEDRO 19 49 ft² 1 0 0______ Slab-On-Grade Edge Insulation - - - -08 ft M WIC 1 20 54 ft² 1 0 0______ Slab-On-Grade Edge Insulation - - - -01 ft M WIC 2 21 234 ft² 1 0 0______ Slab-On-Grade Edge Insulation - - - -037 ft M BATH 22 20 ft² 1 0 0______ Slab-On-Grade Edge Insulation - - - -09 ft M TOILET 23 24 ft² 1 0 0______ Slab-On-Grade Edge Insulation - - - -01 ft W/D 24 36 ft² 1 0 0______ Slab-On-Grade Edge Insulation - - - -018 ft POWDER RM 25 248 ft² 1 0 0______ Slab-On-Grade Edge Insulation - - - -032 ft GAME ROOM 6/25/2020 9:19 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 3 of 8 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT # Type Materials Color Absor. Roof Solar Deck Insul. Pitch ROOF Tested Roof Area Gable Area Emitt Tested EmittSA (deg) Rad Barr 1 Hip Metal 3107 ft² Light 0.2 20 26.6______No0 ft² 0.9 NoN ATTIC # Type Ventilation Area RBS IRCCVent Ratio (1 in) ______ 1 Full attic Unvented 2778 ft² N N0 # Ceiling Type R-Value Area Framing Frac Truss Type CEILING Space Ins Type 1 Under Attic (Unvented)0 156 ft² 0.1 Wood______BEDROOM 4 Blown 2 Under Attic (Unvented)0 18 ft² 0.1 Wood______CLST 4 Blown 3 Under Attic (Unvented)0 54 ft² 0.1 Wood______BATH 3 Blown 4 Under Attic (Unvented)0 132 ft² 0.1 Wood______BEDROOM 3 Blown 5 Under Attic (Unvented)0 16 ft² 0.1 Wood______CLST 3 Blown 6 Under Attic (Unvented)0 64 ft² 0.1 Wood______BATH 2 Blown 7 Under Attic (Unvented)0 140 ft² 0.1 Wood______BEDROOM 2 Blown 8 Under Attic (Unvented)0 16 ft² 0.1 Wood______CLST 2 Blown 9 Under Attic (Unvented)0 105 ft² 0.1 Wood______MUD ROOM Blown 10 Under Attic (Unvented)0 12 ft² 0.1 Wood______AHU CLST Blown 11 Under Attic (Unvented)0 156 ft² 0.1 Wood______DINING Blown 12 Under Attic (Unvented)0 94 ft² 0.1 Wood______FOYER Blown 13 Under Attic (Unvented)0 358 ft² 0.1 Wood______KITCHEN Blown 14 Under Attic (Unvented)0 202 ft² 0.1 Wood______LIVING ROOM Blown 15 Under Attic (Unvented)0 247 ft² 0.1 Wood______FAMILY ROOM Blown 16 Under Attic (Unvented)0 32 ft² 0.1 Wood______HALL Blown 17 Under Attic (Unvented)0 40 ft² 0.1 Wood______HALL 2 Blown 18 Under Attic (Unvented)0 271 ft² 0.1 Wood______MASTER BEDRO Blown 19 Under Attic (Unvented)0 49 ft² 0.1 Wood______M WIC 1 Blown 20 Under Attic (Unvented)0 54 ft² 0.1 Wood______M WIC 2 Blown 21 Under Attic (Unvented)0 234 ft² 0.1 Wood______M BATH Blown 22 Under Attic (Unvented)0 20 ft² 0.1 Wood______M TOILET Blown 23 Under Attic (Unvented)0 24 ft² 0.1 Wood______W/D Blown 24 Under Attic (Unvented)0 36 ft² 0.1 Wood______POWDER RM Blown 25 Under Attic (Unvented)0 248 ft² 0.1 Wood______GAME ROOM Blown WALLS #Wall Type R-Value Area Adjacent Framing Solar Ornt Fraction Absor. HeightWidth Ft In Ft InTo Cavity Sheathing R-ValueSpace Grade% Below 1 5 0BEDROOM 4 00013 10S Concrete Block - Int Insul 0.20Exterior130.0 ft² ____ 2 5 0BEDROOM 4 00012 10W Concrete Block - Int Insul 0.20Exterior120.0 ft² ____ 3 5 0CLST 4 0002 10W Concrete Block - Int Insul 0.20Exterior20.0 ft² ____ 4 5 0BATH 3 0006 10W Concrete Block - Int Insul 0.20Exterior60.0 ft² ____ 6/25/2020 9:19 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 4 of 8 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT WALLS #Wall Type R-Value Area Adjacent Framing Solar Ornt Fraction Absor. HeightWidth Ft In Ft InTo Cavity Sheathing R-ValueSpace Grade% Below 5 5 0BEDROOM 3 00011 10W Concrete Block - Int Insul 0.20Exterior110.0 ft² ____ 6 5 0CLST 3 0002 10W Concrete Block - Int Insul 0.20Exterior20.0 ft² ____ 7 5 0BATH 2 0008 10W Concrete Block - Int Insul 0.20Exterior80.0 ft² ____ 8 5 0BEDROOM 2 00011 10W Concrete Block - Int Insul 0.20Exterior110.0 ft² ____ 9 5 0CLST 2 0002 10W Concrete Block - Int Insul 0.20Exterior20.0 ft² ____ 10 11 0CLST 2 0008 10N Frame - Wood 0.20.1Garage80.0 ft² ____ 11 11 0MUD ROOM 0009 10N Frame - Wood 0.20.1Garage90.0 ft² ____ 12 5 0DINING00013 10N Concrete Block - Int Insul 0.20Exterior130.0 ft² ____ 13 5 0DINING0001 10E Concrete Block - Int Insul 0.20Exterior10.0 ft² ____ 14 11 0DINING0002 10W Frame - Wood 0.20.1Garage20.0 ft² ____ 15 5 0FOYER0009 10N Concrete Block - Int Insul 0.20Exterior90.0 ft² ____ 16 5 0KITCHEN00010 10E Concrete Block - Int Insul 0.20Exterior100.0 ft² ____ 17 5 0KITCHEN0004 10S Concrete Block - Int Insul 0.20Exterior40.0 ft² ____ 18 5 0LIVING ROO 00011 11S Concrete Block - Int Insul 0.20Exterior121.0 ft² ____ 19 5 0FAMILY ROO 00014 11E Concrete Block - Int Insul 0.20Exterior154.0 ft² ____ 20 5 0MASTER BE 00017 11E Concrete Block - Int Insul 0.20Exterior187.0 ft² ____ 21 5 0MASTER BE 0003 11S Concrete Block - Int Insul 0.20Exterior33.0 ft² ____ 22 5 0MASTER BE 0037 11SW Concrete Block - Int Insul 0.20Exterior79.8 ft² ____ 23 5 0M WIC 1 0007 10E Concrete Block - Int Insul 0.20Exterior70.0 ft² ____ 24 5 0M WIC 1 0001 10S Concrete Block - Int Insul 0.20Exterior10.0 ft² ____ 25 5 0M BATH 00014 10N Concrete Block - Int Insul 0.20Exterior140.0 ft² ____ 26 5 0M BATH 00010 10E Concrete Block - Int Insul 0.20Exterior100.0 ft² ____ 27 5 0M BATH 00013 10W Concrete Block - Int Insul 0.20Exterior130.0 ft² ____ 28 5 0M TOILET 0004 10N Concrete Block - Int Insul 0.20Exterior40.0 ft² ____ 29 5 0M TOILET 0005 10E Concrete Block - Int Insul 0.20Exterior50.0 ft² ____ 30 11 0W/D 0004 10N Frame - Wood 0.20.1Garage40.0 ft² ____ 31 11 0W/D 0006 10W Frame - Wood 0.20.1Garage60.0 ft² ____ 32 5 0POWDER R 0006 10E Concrete Block - Int Insul 0.20Exterior60.0 ft² ____ 33 5 0POWDER R 0006 10S Concrete Block - Int Insul 0.20Exterior60.0 ft² ____ 34 5 0POWDER R 0006 10W Concrete Block - Int Insul 0.20Exterior60.0 ft² ____ 35 5 0GAME ROOM 00015 10E Concrete Block - Int Insul 0.20Exterior150.0 ft² ____ 36 5 0GAME ROOM 00017 10S Concrete Block - Int Insul 0.20Exterior170.0 ft² ____ #Door Type U-Value AreaStorms DOORS Ornt Space Width Ft In Ft In Height 1 Insulated .34 48 ft² None______N FOYER 86 2 Insulated .27 21.3 ft² None______N MUD ROOM 882 6/25/2020 9:19 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 5 of 8 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT # Ornt Panes NFRC U-Factor SHGC Area Depth Separation Int ShadeFrame Screening WINDOWS Overhang Orientation shown is the entered, Proposed orientation. Wall ID Imp 1 S Low-E Single 0.55 0.22 15.0 ft² 2 ft 0 in 0 ft 7 in NoneMetal None______Yes1 Y 2 W Low-E Single 0.55 0.22 15.0 ft² 2 ft 0 in 0 ft 7 in NoneMetal None______Yes2 Y 3 W Low-E Single 0.55 0.22 6.0 ft² 2 ft 0 in 0 ft 7 in NoneMetal None______Yes4 Y 4 W Low-E Single 0.55 0.22 15.0 ft² 2 ft 0 in 0 ft 7 in NoneMetal None______Yes5 Y 5 W Low-E Single 0.55 0.22 6.0 ft² 2 ft 0 in 0 ft 7 in NoneMetal None______Yes7 Y 6 W Low-E Single 0.55 0.22 15.0 ft² 2 ft 0 in 0 ft 7 in NoneMetal None______Yes8 Y 7 N Low-E Single 0.55 0.22 36.0 ft² 8 ft 0 in 0 ft 6 in NoneMetal None______Yes12 Y 8 E Low-E Single 0.55 0.22 20.0 ft² 8 ft 0 in 0 ft 7 in NoneMetal None______Yes16 Y 9 S Low-E Single 0.55 0.22 72.0 ft² 14 ft 0 in 0 ft 7 in NoneMetal None______Yes18 Y 10 E Low-E Single 0.55 0.22 72.0 ft² 2 ft 0 in 0 ft 7 in NoneMetal None______Yes19 Y 11 E Low-E Single 0.55 0.22 20.0 ft² 2 ft 0 in 0 ft 7 in NoneMetal None______Yes20 Y 12 SW Low-E Single 0.55 0.22 46.7 ft² 14 ft 0 in 0 ft 7 in NoneMetal None______Yes22 Y 13 N Low-E Single 0.55 0.22 25.0 ft² 2 ft 0 in 0 ft 6 in Drapes/blindsMetal Exterior 5______Yes25 Y 14 E Low-E Single 0.55 0.22 9.0 ft² 2 ft 0 in 0 ft 7 in NoneMetal None______Yes29 Y 15 W Low-E Single 0.55 0.22 20.0 ft² 8 ft 0 in 0 ft 7 in NoneMetal None______Yes34 Y 16 E Low-E Single 0.55 0.22 48.0 ft² 2 ft 0 in 0 ft 7 in NoneMetal None______Yes35 Y 17 S Low-E Single 0.55 0.22 12.0 ft² 2 ft 0 in 0 ft 7 in NoneMetal None______Yes36 Y 18 N Low-E Single 0.55 0.22 9.2 ft² 7 ft 5 in 0 ft 7 in NoneMetal None______Yes15 Y 19 N Low-E Single 0.55 0.22 9.2 ft² 7 ft 5 in 0 ft 7 in NoneMetal None______Yes15 Y # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation GARAGE 1 546 ft² 546 ft² 29 ft 10 ft 11______ Method CFM 50 ACH 50ELASLAScope INFILTRATION ACHEqLA# 3325 7182.54.000456Wholehouse .1747343.29Proposed ACH(50)1 HEATING SYSTEM # System Type Efficiency Capacity DuctsSubtypeBlockSpeed 1 Electric Strip Heat/COP:1 34 kBtu/hr ______sys#1None1 # System Type Efficiency Capacity Air Flow SHR COOLING SYSTEM DuctsSubtypeBlockSubtype 1 Central Unit/SEER: 16 46.5 kBtu/hr 1395 cfm 0.8______sys#1Split1 Single 6/25/2020 9:19 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 6 of 8 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT # System Type EF Cap Use SetPnt Conservation HOT WATER SYSTEM SubType Location 1 Electric 0.98 50 gal 62.3 gal 120 deg None______None Garage FSEC Company Name System Model #Collector Model # Collector SOLAR HOT WATER SYSTEM Storage FEFCert #Area Volume None None f t ² ______ # Location R-Value Area Location Area ---- Supply -------- Return ---- Leakage Type Handler CFM 25Air QN RLF DUCTS Heat Cool HVAC # TOT OUT CFM25 1 Attic 6 200 ft² Attic 20 ft² Default Leakage AHU CLST (Default) c______1 1 (Default) c TEMPERATURES Programable Thermostat: N Ceiling Fans: Cooling [ ] Jan [ ] Feb [ ] Mar [ ] Apr [ ] May [X] Jul [X] Aug [X] Sep [ ] Oct [ ] Nov [ ] Dec [ ] Dec [X] Dec[X] Nov [X] Nov [ ] Oct [X] Oct [ ] Sep [ ] Sep [ ] Aug [ ] Aug [ ] Jul [ ] Jul[ ] Jun [ ] Jun [X] Jun [ ] May [ ] May [ ] Apr [X] Apr [X] Mar [X] Mar [X] Feb [ ] Feb [X] Jan [ ] Jan Heating Venting Thermostat Schedule:HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD)AM PM 78 80 78 80 78 80 78 80 78 78 78 78 78 78 78 78 80 78 80 78 80 78 80 78 Cooling (WEH)AM PM 78 80 78 80 78 80 78 80 78 78 78 78 78 78 78 78 80 78 80 78 80 78 80 78 Heating (WD)AM PM 65 68 65 68 65 68 65 68 65 68 65 68 65 68 68 68 68 68 68 68 68 68 68 68 Heating (WEH)AM PM 65 68 65 68 65 68 65 68 65 68 65 68 65 68 68 68 68 68 68 68 68 68 68 68 MASS Mass Type Area Thickness Furniture Fraction Space Default(8 lbs/sq.ft.0 ft² 0 ft 0.3 BEDROOM 4 Default(8 lbs/sq.ft.f t ² f t 0.3 CLST 4 Default(8 lbs/sq.ft.f t ² f t 0.3 BATH 3 Default(8 lbs/sq.ft.f t ² f t 0.3 BEDROOM 3 Default(8 lbs/sq.ft.f t ² f t 0.3 CLST 3 Default(8 lbs/sq.ft.f t ² f t 0.3 BATH 2 Default(8 lbs/sq.ft.f t ² f t 0.3 BEDROOM 2 Default(8 lbs/sq.ft.f t ² f t 0.3 CLST 2 Default(8 lbs/sq.ft.f t ² f t 0.3 MUD ROOM Default(8 lbs/sq.ft.f t ² f t 0.3 AHU CLST Default(8 lbs/sq.ft.f t ² f t 0.3 DINING Default(8 lbs/sq.ft.f t ² f t 0.3 FOYER Default(8 lbs/sq.ft.f t ² f t 0.3 KITCHEN Default(8 lbs/sq.ft.f t ² f t 0.3 LIVING ROOM Default(8 lbs/sq.ft.f t ² f t 0.3 FAMILY ROOM Default(8 lbs/sq.ft.f t ² f t 0.3 HALL 6/25/2020 9:19 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 7 of 8 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT MASS Mass Type Area Thickness Furniture Fraction Space Default(8 lbs/sq.ft.f t ² f t 0.3 HALL 2 Default(8 lbs/sq.ft.f t ² f t 0.3 MASTER BEDROO Default(8 lbs/sq.ft.f t ² f t 0.3 M WIC 1 Default(8 lbs/sq.ft.f t ² f t 0.3 M WIC 2 Default(8 lbs/sq.ft.f t ² f t 0.3 M BATH Default(8 lbs/sq.ft.f t ² f t 0.3 M TOILET Default(8 lbs/sq.ft.f t ² f t 0.3 W/D Default(8 lbs/sq.ft.f t ² f t 0.3 POWDER RM Default(8 lbs/sq.ft.f t ² f t 0.3 GAME ROOM 6/25/2020 9:19 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 8 of 8 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT ��������������������������������������������������������������������������� ��������������������������������������������������������������������������������� �����������������������������������������������������