HomeMy WebLinkAboutFuel.Gas PATPRESUTTI - 430 Woodcrest Dr_SupportingDocsProperty Card
https://www.paslc.org(RECard/#/propCard/13120
Michelle Franklin, CFA -- Saint Lucie County Property Appraiser -- All rights reserved.
Site Address: 430 Woodcrest DR
Sec/Town/Range: 08/35SI39E
Map ID: 23/08N
Zoning: AR-1 Count
Ownership
Pat Presuni
Melissa C Presuni
430 Woodcrest Dr
Fort Pierce, FL 34945
Property Identification
Parcel ID: 2308-501-0023-000-6
Account #: 13120
Use Type: 0100
Jurisdiction: Saint Lucie County
Legal Description
ORANGE PARK S/D BLK B LOT 10 (1.04 AC) (OR 1142-848)
Current Values
Just/Market Value:
$276,900
Assessed Value:
$201,089
Exemptions:
$50,000
Taxable Value:
$151,089
Property taxes are subject to change upon
change of ownership.
• Past taxes are not a reliable projection of future taxes.
• The sale of a property will prompt the removal of a0
exemptions, assessment caps, and special
classifications.
Taxes for this parcel: SLC Tax Collector's Office [Ili
Download TRIM for this parcel: Download PDF C
W-
Total Areas
Finished/Under Air (SF):
2,222
Gross Sketched Area (SF):
8,816
Land Size (acres):
1.04
Land Size (SF):
45,302.4
Sale History
Date Book/Page
Sale Deed Grantor
Price
Code
Apr 30, 1998 1142 / 0848
XX00 WD Johnson James W
$25,000
Oct 1, 1983 0414 / 1982
XX00 CV
$15,500
Building Information (1 of 2)
Finished Area: 2,222 SF
Gross Sketched Area: 5,298 SF
Exterior Data
View:
Roof Cover: Dim Shingle
Roof Structure: Hip
Building Type: HB
Year Built: 1999
Frame:
Grade: B
Effective Year: 1999
Primary Wall: CB Stucco
Story Height: 1 Story
No. Units: 1
Secondary Wall:
Interior Data
Bedrooms: 0
Electric: MAXIMUM
Primary lot Wall:
Full Baths: 3
Hem Type: FrcdHotAir
Avg Hgt/Floor: 0
Half Baths: 0
Heat Fuel: ELEC
Primary Floors: Carpet
A/C W 1000/.
Heated %: 100%
Sprinkled W 0%
I of 3 5/28/2020, 12:52 PM
Property Card
View:
Building Type: DGAR
Grade: DG-
Story Height: I Story
Bedrooms: 0
Full Baths: 0
Half Baths: 0
A/C %: 0°/u
https://www.paslc.or&'RECard/g/propCard/13120
Sketch Area Legend
Sub Area Description Area Fin. Area Perimeter
APSA
Aluminium Porch (Screen) Average
456
0
99
BAS
BASE AREA
2222
2222
264
GAA
Garage Attached Average
720
0
108
NVPD
Pool Deck for Sketch Only (Valued in SFYI)
1485
0
156
OPAH
Open Porch Attached High
64
0
32
SPAA
Screen Porch Attached Average
186
0
54
URAA
Utility Room Attached Average
165
0
52
Building Information (2 of 2)
Finished Area: 0 SF
Gross Sketched Area: 3,518 SF
Exterior Data
Roof Cover: Suet Metal
Year Built: 2009
Effective Year: 2009
No. Units: 0
Interior Data
Electric:
Heat Type:
Heat Fuel:
Heated %: %
Sketch Area Legend
Roof Structure: Gable
Frame:
Primary Wall: Corr Metal
Secondary Wall:
Primary Int Wall:
Avg Hgt/Floor: 0
Primary Floors:
Sprinkled %: 0%
2of3
Sub Area Description Area Fin. Area Perimeter
GDA Garage Detached Average 1260 0 144
5/28/2020, 12:52 PM
Property Card https://www.pasle.org/RECardi#/propCard/13120
PATA Patio Average (Plain Slab) 2258 0 346
Type
Driv-Concret
VINYLFENCEY
POOL DK-AVG
SPA -HOT TUB
RES POOL HI
UTILITY AVG
Current Values Breakdown
Building:
Land:
Just/Market:
Ag Credit:
Save Our Homes or
10% Cap:
Assessed:
Exemption(s):
Taxable:
Start Year
2013
Year
2019
2018
2017
$234,300
$42,600
$276,900
$0
$75,811
Special Features and Yard Items
Qty
Units
Year Bit
1
1650
1999
1
ill
2004
1
1149
2004
1
25
2004
1
336
2004
1
144
2009
Current Year
Values
Current Year Exemption Value Breakdown
Tax
Grant
Code
Description
Year
Year
2019
2000
0500
Homestead
Exemption
2019
2008
0550
Homestead
Examption over $
50,000
Amount
$25,000
$25,000
$201,089
$50,000
$151,089
Current Year Special Assessment Breakdown
AssessCode Units Description Amount
0054 1.04 North St. Lucie Water Management $25.00
District
This does not necessarily represent the total Special Assessments that could be charged against this property. The total amount
charged for special�88sssessments is reflected on the most current tax statement and information is available with the SLC Tax
Coilemes omee'SIJ.
Number
C99-110677
98-100071
C23090338
C0906-0022
C1804-0755
C1808-0503
C1803-0433
Historical Values
Just/Market
Assessed
Exemptions
Taxable
$276,900
$201,089
$50,000
$151,089
$258,700
$197,340
$50,000
$147,340
$253,700
$193282
$50,000
$143,282
Permits
Issue Date
Description
Amount
Fee
Dec 13, 2000
Shed
$3,040
$0
Oct 23, 1998
Residential New
$115,452
$115,452
Construction
Sepp 16, 2003
Pool
$20,000
$302
Ju110,2009
Shed
$0
$0
Apr 30, 2018
Roof
$0
$0
Aug 23, 2018
Remodel
$0
$0
Mar 15, 2018
Window
$0
$0
replacement
Notice: This does not necessarily represent all the permits for this property.
Click the following link to check for additional permit data in Saint Lucie County
All information is believed to be correct at this time, but is subject to change and is provided without any warranty.
® Copyright 2020 Saint Lucie County Property Appraiser. All rights reserved.
3 of 3 5/28/2020, 12:52 PM
WHY CHOOSE QUALITY STEEL
UNDERGROUND TANKS?
• 120 - 1,990 WG CAPACITY
• General Specifications
• Conforms to the latest edition of ASME Rules for Construction of
Pressure Vessels, Section VIII, Division 1
• Complies with NFPA 58.
• Rated at 250 psig from -200 F to 1250 F. All vessels registered
with National Board.
• Two service options available:
• Option 1: Ready -to -bury underground option, coated with
either powder coated phenolic epoxy finish or liquid applied
epoxy primer coat followed by urethane top coat, supplied
with composite AG/UG dome
• Option 2: Aboveground option, coated with either powder coated
TGIC polyester finish or liquid applied epoxy primer coat followed
by urethane top coat, supplied with steel AG/UG dome
• Family & employee owned
• Financing and leasing available
• Customized delivery programs available
HOW DO I FIND MY
SALES REP?
Visit our website, www.propanetank.com to
view a list of our reps. Once on our site you'll
be able to choose the Commercial options and
from there you'll be taken to a list of US states
where you can choose your location and view
the contact information for your local sales rep.
If you don't see your sales rep. please give us
a call at 800-345-2495.
Our manufacturing locations are strategically
located to help serve your tank needs.
OHIO LOCATION
721 Graham Drive
Fremont, OH 43420
UTAH LOCATION
5601 Axel Park Rd.
West Jordan, UT 84081
801-280-1133
HOME OFFICE
2914 U.S.61
Cleveland, MS 38732
800-345-2495
Consult our dimension and specification chart below to find the tank that best fits your needs.
Visit our website at www.propanetank.com for more information.
OVERALLLENGTH
OV
HI
LEG SPACING 0.1
APPROXIMATE ABOVEGROUND/UNDEGROUND (AG/UG) VESSEL
LEG WIDTH
AND SPECIFICATIONS
WATER
CAPACITY
DIAMETER
(OD)
HEAD
TYPE
OVERALL
LENGTH
OVERALL
HEIGHT
LEG*
WIDTH
LEG**
SPACING
WEIGHT
(lbs.)
**QUANTITY
FutI.LQAo
PER STACK
*120 wg.
24"
Ellip.
5'-8"
3'
1'-1 1/2"
2'-10 1/2"
or T-11"
260
108 1 96
16 1 12
*250 wg.
30"
Hemi.
7-10"
3'-8"
V-5"
4'-11"
480
54
9
*320 wg.
30"
Hemi.
9'-7"
3'-8"
V-5"
5'
620
45
9
500 wg.
37 1/2"
Hemi.
10,
4'-2"
1'-8"
5'
1 950
37 30
8 6
1000 wg.
41"
Hemi.
16'
4'-5"
V-8"
10'-1"
1,800
17 15
6 5
1450 wg.
46 1/2"
Ellip.
17'-4"
4'-11"
V-9"
11'-7"
2,650
12
4
1990 wg.-
46 1/2"
Ellip.
23'-11"
4'-11"
V-9"
16'
3,520
8
4
Dimensions and specifications shown are approximate. Individual vessels may vary
* Leg spacing +/- 2". Leg widths and spacing may vary based on mfg. location. Check with your salesperson for details. 120, 250, 320 wg. standard
tanks - no holes in legs (one center hole on request). 500 and 1000 wg. standard tanks - 2 holes 16" on center. 1450 wg. and up as shown above.
** Full load and stack quantities vary by shipping location. Check with your salesperson for details.
QUALITY STEEL
Because Qu fity Steel Means QUOIA/ Tanks
f rh,la VUU 1,U S.l, 0ul,, J USA MAUAMUIIEIS It
HOME OFFICE
2914 U.S.61
Cleveland, MS 38732
800-345.2495
OHIO LOCATION
721 Graham Drive
Fremont, OH 43420
419-334-2664
UTAH LOCATION
5601 Axel Park Rd.
West Jordan, UT 84081
801 --280-1133
Quality Steel 6/2017 S2
STORAGE TANK IS ADEQUATELY
ANCHORED TO PREVENT FLOATATION,
COLLAPSE OR LATERAL MOVEMENT
DURING THE BASE FLOOD EVENT.
ALL WORK SHALL BE IN ACCORDANCE WITH
NFPA 54-58, NATIONAL FUEL GAS CODE
AND FLORIDA FUEL GAS CODE 2017 k
FLORIDA BUILDING CODE 2017.
TANKS INSTALLED IN TRAFFIC AREAS
SHALL BE PROTECTED WITH GALV. STEEL
SCHED. 80 PIPE BOLLARDS (4'4) 6' LONG
X 3' BURY DEPTH WITH CAP ® 3' O.C.
PROPANE TANK BUOYANCY
MAX BUOYANCY = p.*g*Vtm►
= 1.94 slug/ft' * 32.2 ft/s' * 66.84 ft'
= 4176 LBS
NET BUOYANCY = MAX BUOYANCY — WEIGHT OF EMPTY TANK
= 4176 LBS — 871 LBS
= 3305 LEIS
FORCE ON r CABLE = 3305 / 2 = 1653 LEIS
TENSILE STRENGTH OF r CABLE = 7000 LBS
FORCE ON AUGER ANCHOR = 1653 / 2 = 827 LBS
MIN. PULL—OUT RESISTANCE OF AUGER ANCHOR = 1360 LBS
LP TANK
r 7xl9 GALV.
AIRCRAFT CABLE
2 TOTAL (IN POLY.
SLEEVE)
AUGER ANCHOR, 36'
LONG W/ 6.0 HELIX
4 TOTAL
SIDE ELEVATION
SCALE 1/4' - 1'-0'
Fm
9LB. ANODE BAG
LP TANK EXCAVATION SIZE:
IAx4'Wx4.5'D
r 7x19 GALV.
AIRCRAFT CABLE
F STRAPPING BOLT
AUGER ANCHOR, 36'
LONG W/ 6.0 HELIX
FRONT ELEVATION
SCALE 1/4' - I'—O'
Ferrellgas
3232 SE Dixie Hwy.
Stuart, FL 34997
Fort Pierce Engineering, Inc.
Depe�& n MecMOlcd, Eleciricd
df P1VIINo 28 73
C.A No.28V3
315 South 7th Sveei
Fon Pierce, FL. 34950
Plant: 772 6724636
Fax: 772 672-4637
Eric J. Svoboda,-PE
..,P.E. No. 60962
.ISSUE DATE:y �.
r V
DRAWN: EJS
APPROVED: EJ$
DRAWING NUMBER
T-1
LP500
NFPA 58-2017 and 2020 Editions
Liquefied Petroleum Gas Code
TIA Log No.: 1480
Reference: 'fable 16.1(n)
Comment Closing Date: June 17, 2020
Submitter: Tom Dunn, Iowa Propane Gas Association
www nfoa orgjll
1. Revise Table 16.l(n) to read asJollows (highlighted to show corrections):
Inlet Pressure: 10.0 psig
Pressure Drop: 1.0
psig _.
Specific'1.52
Gravity:
Plastic Pipe
,/2 in. SDR
Vf in. SDR
1 in. SDR
1,/n in. SDR
L/a in. SDR It
2 in. SDR 11.
Length
9.33
i1
11
11
(1.554)
(1.943)
(it)
(0.660)
(0.860)
(1.00'7)
(1.328)
INTENDED USE:
Sizing Between
First -Stage Pressure
Regulator
and Second -Stage (low -Pressure)
Regulator...
30
2140
23904290
7740 I
13420
20300 j
36400
40
1840
3670
6630
11480
17300
31200
50
1630
3260
5870
10180
15400
27600
60
1470
2950
5320
9220
13900
25000
70
1360
2710
4900
8480
12B00
23000
80
1260
2530
4560
7890
11900
21400
90
1180
2370
4270
7400
11200
20100
100
1120
2240
4040
6990
10600
19000
125
990
9Q#AW
3580
6200
9360
16800
150
897
3240
5620
8480
15200
175
826
2980
5170
7800
14000
200
778
2780
4810
7260
13000
225
721
2600
4510
6810
12200
250
681
,,.
2460
4260
6430
11600
275
646
';Q
2340
4050
6110
11000
300
617
2230
3810
5830
10470
350
567
2050
3550
5360
9640
400
528
1910
3300
4990
8970
450
495
u
3100
4680
8410
Soo
468
46OW
W1$;11)
2930
4420
7950
600
424
4illi
801M
2650
4010
7200
700
390
i
2440
3690
6620
800
363
2270
3430
6160
900
340
2130
3220
5780
1000
322
Q
2010
3040
5460
1500
258
$
go=
461Qd"
4390
2000
1 221
401M
I A"0121=1 1
3750
Ideal for use as a first stage regulator on any domestic size ASME or O
DOT container in propane gas installations requidng up to 1,500,000
BTU's per hour. The regulator is factory set to reduce container usm
Pressure to an intermediate pressure of approximately 10 conta
Compact design can be connected to a service valve using either
a POL adapter or a Rego product pigtail.
Large threaded W FNPT bonnet vent can easily be piped -away
underground installations without the need of glue kits or extra
adapters.
Non Adjustable
• Large flow orifice
LPG vapor. resists freeze ups due to water concentration in
• Design provides for good now regulation a
container pressures. t both high and low
Built in relief valve and travel stop comply with NFPA 58 over
Pressure requirements.
Incorporates W F.NPT downstream pressure tap for an easy
inline check of the regulator's delivery pressure
Molded diaphragm provides an o-ring type seal between the
body and bonnet.
Body and bonnet are assembled in the USA using the unique,
Patented RegUbk seal system.
Fully Painted in brilliant red for complete corrosion protection
• Mounting bracket available as an a ceessory: part number 2302-31.
Bt.'.dtegi a
Body............................................................................................Zinc
Bonnet......................
...................................................................Zinc
SSpring........................................................................................ Steel
eat Disc ......................................... .
• � ••�•••�••--••-••�d Synthetic
Resilient Rubber
DraWrregm•••••••••••-.•••••.........Integretetl Fabric and Synthetic Rubber
LV3403Tk
3.56•___�
�.vewmq.
Af4
100 Rego or. Elaq NC 272" UU wYN.npeprptlyye, •1(336) 44
9
•7707
Designed to reduce first stage pressure of 5 to 20 PSIG down to
burner pressure, normally 11" w.c. Ideal for medium commercial
installations, vapor meter installations and normal domestic loads.
• 90 degree right angle inlet to outer connection for meter or
standard installations.
• Large vent helps to prevent blockage and has''%" F. NPT for vent
piping.
• With 15 PSIG inlet pressure, regulator is designed to not pass
MOM than 2 PSIG with the seat disc removed.
• Replaceable valve orifice and valve seat.
• Straight line valve closure reduces wear on seat disc
• Unique bonnet vent profile minimizes vent freeze over when
Property installed.
• Large molded diaphragm is extra sensitive to pressure changes.
• Suitt in pressure tap has plugged %" F. NPT outlet. Plug can be
removed with a 3/16" hex alien wrench.
• Select Brown Finish
Can mount directly to vapor meter. It is also suitable for mounting
directly to the house piping. It will retrofit into existing installations that
are currently using a 90 degree, right angle regulator.
Body...........................................................................
Die Cast Zinc
Bonnet........................................................................
Die Cast Zinc
NozzleOrifice .........................................................................
Brass
Spring.....................................................................................
Steel
Valve Seat Disc .....................................................
Resilient Rubber
Diaphragm .........................
Integrated Fabric and Synthetic Rubber
TdmomlhKBradm
Now
9djusenentBonnet Vent
Range:. . pwton
LV4401386GRA
LV4403666RA6•' 'W F. NPT
W F. NPT 1 3116'
11"w.c. at 10
PSIG Inlet
' MaA-um ibw is based on 10 PSIG,nW and 9' w.w delivery preuure.
'• Mounting Brecht indwded.
100 Rego Dr. Elora, NC 27244 USA uww.regoproduCs = .1 (336)449-7707 EGO
rr r rr
r11 rer r rer
1,000,000
0