Loading...
HomeMy WebLinkAboutDesign Pressure Report (PHILIP KRON) - Galeforce Hurricane ShuttersProperty Information Owner:PHILIP KRON Address:1499 NW WILD OLIVE CT PALM CITY, FL 34990 Building Information Wind Zone:170 MPH. Exposure Category:B Minimum Building Dimension:5 ft. Mean Roof Height:15 ft. Risk Category:II Design Pressure Calculations Opening Number Location Zone Device Width (in) Device Height (in) Device Elevation (ft) Max Positive Pressure (psf) Max Negative Pressure (psf) 1 Int 87 140 7 26.8 -29.5 2 Int 66 84 7 28.4 -31.1 3 Int 90 108 7 27.3 -29.9 4 Int 40 84 7 29.5 -32.1 5 Int 42 84 7 29.4 -32.0 6 Int 62 84 7 28.6 -31.2 9 Int 60 108 7 28.1 -30.8 10 Int 108 125 7 26.6 -29.3 11 Int 66 84 7 28.4 -31.1 12 Int 108 125 7 26.6 -29.3 13 Int 134 118 7 26.3 -29.0 14 Int 128 108 7 26.6 -29.2 15 Int 156 118 7 26.0 -28.6 16 Int 42 84 7 29.4 -32.0 17 Int 66 84 7 28.4 -31.1 18 Int 66 84 7 28.4 -31.1 19 Int 84 84 7 27.9 -30.6 Prepared in accordance with: ASCE 7-10, Chapter 30. Wind Loads - Components and Cladding. 6th Edition (2017) Florida Building Code. Page 1 of 1