Loading...
HomeMy WebLinkAboutEngineerCONTRACTOR: South Florida Aluminum Products DESIGN CRITERIA: .Applicable Codes, Regulation., :end tiSbn Ards 1. The 6th Edition (2017) Florida Building Code, specifically Chapter 16 Structural Design, Chapter 20 Aluminum, and Chapter 23 Wood. 2. ASCE 7-10. Loading C'ritei-ia 1. Wind Load: 1.1. Building Occupancy Category, Section 1604.5 and Table 1604.5: Risk CateEory 2. 1.2. Ultimate Design Wind Speed: VULT = 1601/IPH, Nominal Design Wind Speed: VASD = 124 MPH as required by local jurisdiction. 2. Exposure Category, Section 1609.4.3: Exposure C Scope of Work: 1. Replacement of (5) Accordian Shutters and (1) Storm Panels. Builder / Permit Application is to provide Florida Product Approvals meeting required design pressures. OPENING SCHEDULE MARK SIZE (W'xH") MANUFACTURER SERIES # A OPENING:74x63 AMERICAN SHUTTER SYSTEMS ACCORDIAN SHUTTER - BLADE 1 +35.0/-45.3 PSF SHUTTER SIZE: 85.5x69 ASSOCIATION, INC.(IMPACT) �BERTHAHV +33.8/-42.9 PSF OPENING: 74x38.375 AMERICAN SHUTTER SYSTEMS HV ACCORDIAN SHUTTER - BLADE 1 (r) SHUTTER SIZE:85.5x44 ASSOCIATION. INC. (IMPACT) C OPENING: 3708.375 AMERICAN SHUTTER SYSTEMS BERTHA HV ACCORDIAN SHUTTER - BLADE 1 SHUTTER SIZE:43.5x44 ASSOCIATION, INC. (IMPACT) D OPENING: 74x38.375 AMERICAN SHUTTER SYSTEMS BERTHA HV ACCORDIAN SHUTTER - BLADE 1 SHUTTER SIZE: 85.5x44 ASSOCIATION, INC. (IMPACT) ZL OPENING: 72x80 SHUTTER SIZE:82.25x83 AMERICAN SHUTTER SYSTEMS ASSOCIATION, BERTHA HV ACCORDIAN SHUTTER - BLADE 1 INC. (IMPACT) ZL STORM PANELS W/ TRACKS 6 O 83' EASTERN METAL SUPPLY 0.050" BERTHA ALUM STORM PANEL 2 INCH ( ) (IMPACT) OPENING: 72x80 SHUTTER SIZE: 82.25x83 OPENING: 74x38.375 D SHUTTER SIZE: 85.5x44 OPENING: 37x38.375 C SHUTTER SIZE: 43.5x44 OPENING: 74x38.375 B SHUTTER SIZE: 85.5x44 AA APPROVALS FL1850.3-R11 FL1850.3-R11 FL1850.3-R11 FL1850.3-R11 FL1850.3-R11 FL11964.1-R4 STORM PANELS W/ TRACKS 6 ® 83" 2L 25'-0" BUILDING HEIGHT APP# 207 OPENING: 74x63 SHUTTER SIZE: 85.5x69 FRONT DOOR DESIGN PRESSURES ALLOWABLE PRESSURES +33.9/-43.1 PSF +70.0/-70.0 PSF +35.0/-45.3 PSF +70.0/-70.0 PSF +36.6/-48,6 PSF +70.0/-70.0 PSF +35.0/-45.3 PSF +70.0/-70.0 PSF +33.5/-42.4 PSF +70.0/-70.0 PSF +33.8/-42.9 PSF +50.0/-50.0 PSF cc W W LU a Z W Z v J I= � Z Q Z O a LA LLJ V) N Q LLJ (J I O O J = CL 1- CL 2 - U �Z� 09 Z_ 0 U- $ o O C� *� Q Q 11,1 (0 �t LU W • Q 1 .v a o,co k (r) o O Z $ o o cc W W LU a Z W Z v J I= � Z Q Z O a LA LLJ V) N Q LLJ (J I O O J = CL 1- CL 2 - U �Z� 09 Z_ $ 5 Z Nq Q W2aMM Q W Z�m� H Z _Z (r) o O Z $ o LJL W N V) W J Q � LL H W_ Q H U U fLLJryJ J � Q LU O d mg�a DRAWN BY TP DATE DRAWN 06/12/20 REVISION Q - SHEET NO: A-1 x C z