Loading...
HomeMy WebLinkAboutEnergy CodeFORM R405-2017 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: WYNNE THE WIND-SOF},IMPACT Builder Name: WYNNE DEVELOPMENT ' Street: -; �j.('op ` v „,� PermitOffice: ST. LUCIE COUNTY City, State, Zip: FT.. PIERCE, FL, ` Permit Number. Owner: Jurisdiction: Design Location: FL, Fort Pierce County: St. Lucie (Florida Climate Zone 2 ) 1. New construction or existing New (From Plans) 9. Wail Types(1432.0 sgft.) Insulation Area 2. Single family or multiple family Single-family a. Concrete Block- Int Insul, Exterior R=4.1 1224.00 W b. Frame - Wood, Adjacent R=11.0 208.00 ft2 3. Number of units, if multiple family 1 c. N/A R= ft' 4. Number of Bedrooms 3. d. N/A R= ft2 10. Ceiling Types (1783.0 sqft.) Insulation Area 5. Is this a worst case? Yes a. Under Attic (Vented) R=30.0 1753.00 ft2 6. Conditioned floor area above grade (ft� 1753 b. Knee Wall (Vented) R=19.0 30.00 ft' Conditioned floor area below grade (ft2) 0 c. N/A R= ft2 11. Ducts R ft2 7. Windows(151.4 sgfL) Description Area a. Sup: Attic, Ret: Attic, AH: Attic 6 175 a. U-Factor. Sgl, U=1.04 111.36 ft' SHGC: SHGC=0.29 b. U-Factor. Sgl, U=1.11 40.00 ft2 12. Cooling systems kBtulhr Efficiency SHGC: SHGC=0.27 - a. Central Unit 34.8 SEER:15.00 c. U-Factor: N/A ft2 SHGC: 13. Heating systems kBtu1hr Efficiency d. U-Factor. WA ft2 a. Electric Heat Pump 34.8 HSPF:8.50 SHGC: Area Weighted Average.Overhang Depth: 2.850 ft. Area Weighted Average SHGC:. 0.285 14. Hot water systems 8. Floor Types (1753.0 sqft.) Insulation Area a. Electric Cap: 40 gallons a. Slab -On -Grade Edge Insulation R=0.0 1753.00 ft2 b. Conservation features EF: 0.970 b. N/A R= ft2 None c. WA R= ft2 15. Credits Pstat Glass/Floor Area: 0.086 Total Proposed Modified Loads: 52.20 PASS /� A SS Total Baseline Loads: 53.92 I hereby certify that the plans and specifications covered by Review of the plans and this calculation are in compliance with the Florida Energy Code. specifications covered by this y Cl calculation indicates compliance the Florida Energy Code. a with „r PREPARED BY: Q Before construction is completed DATE: 1-9-2D this building will be inspected for compliance with Section 553.908 n hereby certify that this building, as designed, is i pliance Florida Statutes. �C��Willi with the Florida Energy Cod OWNER/A d BUILDING OFFICIAL: DATE: DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with 11403.3:2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist In accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 5.00 ACH50 (R40? g, VIEWED FOR CODE COMPLIANCE ST. LUCIE COUNTY 1/8/2020 4:43 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) CompiiaRCSo�Na ANC . Pagel of 6 FORM R405-2017 INPUT. SUMMARY, CHECKLIST REPORT PROJECT Title: WYNNE THE WINDSOR IMP Bedrooms: 3 Address Type: Street Address Building Type: User Conditioned Area: 1753 Lot # ' Owner Name: Total Stories: 1 Block/Subdivision: # of Units: 1 Worst Case: Yes PlatBook: Builder Name: WYNNE DEVELOPMENT Rotate Angle: 0 Street: Permit Office: ST. LUCIE COUNTY Cross Ventilation: No County: St. Lucie Jurisdiction: Whole House Fan: No City, State, Zip: FT. PIERCE, Family Type: Single-family FL, New/Existing: New (From Plans) Comment: CLIMATE / Design Temp Int Design Temp Heating Design Dally Temp V Design Location TMY Site 97.5 % 2.5 % Winter Summer Degree Days Moisture Range FL, Fort Pierce FL VERO BEACH_MUNI 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume 1 Entire. House 1753 14024 SPACES Number Name Area Volume Kitchen Occupants Bedrooms Infil ID Finished Cooled Heated 1 MASTER BEDROO 224 1792 No 0 1 1 Yes Yes Yes 2 WIC 63 504 No 0 1 No Yes Yes 3 MASTER BATH 56 448 No 0 1 Yes Yes Yes 4 M. BATH 61 488 No 0 1 Yes Yes Yes 5 LAUDRY 36 288 No 0 1 No Yes .Yes 6 BEDROOM - 180 1440 No 0 1 1 Yes Yes Yes 7 DINING/GREATR 588 4704 No 2 1 Yes Yes Yes 8 KITCHEN 209 1672 Yes 0 1 Yes Yes Yes 9 BATH 50 400 No 0 1 Yes Yes Yes 10 HALL 25 200 No 0 1 No Yes Yes 11 FOYER 92 736 No 0 1 Yes Yes Yes 12 BEDROOM 3 169 1352 No 0 1 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Slab -On -Grade Edge Insulatio MASTER BEDRO 37 ft .0 224 W s 0 1 0 2 Slab -On -Grade Edge Insulatio WIC 1 ft 0 63 ft' 0 1 0 3 Slab -On -Grade Edge Insulatio MASTER BATH Bit 0 55 It, — 0 1 0 4Slab-On-Grade Edge Insulatio M. BATH 7 ft 0 61 f6 — 0 1 0 . 5 Slab -On -Grade Edge Insulatio LAUDRY 1 ft 0 36 It' _ 0 1 0 1/8/2020 4:43 PM EnergyGauge®USA 6.0.02.(Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 2 of 6 FORM R405-2017 INPUT. SUMMARY. CHECKLIST REPORT FLOORS # Floor Type Space Perimeter Perimeter R-Value 'Area Joist R-Value Tile Wood Carpet. 6 Slab -On -Grade Edge Insulatio BEDROOM 2 12 ft 0 180 ft2 _ 0 1 0 7 Slab -On -Grade Edge lnsulatio DINING/GREAT 50ft 0 588'ft2 _ 0 1 0 8 Slab -On -Grade Edge lnsulatio KITCHEN 11 ft 0 209 ft2 — 0 1 0 9 Slab -On -Grade Edge lnsulatio BATH 5 ft 0 50 ft2 _ 0 1 0 10Slab-On-Grade. Edge lnsulatio HALL - 1 R 0 25 ft' _ 0 1 0 11Slab-On-Grade Edge lnsulatio FOYER 9 ft 0 92 ft2 _ 0 1 0 12SIab-On-Grade Edge lnsulatio BEDROOM -3 14 ft 0 169 ft2 _ 0 1 0 ROOF / -Roof Gable Roof Red Solar SA Emitt Emitt Deck Pitch V # Type Materials Area Area Color Barr Absor. Tested Tested Insul. (deg) 1 Hip Metal 1847 ft' 0 ft2 Light N 0.4 No 0.9 No 0 18.4 ATTIC / V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Vented 150 1753 ft2 N N CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type . _ 1 Under Attic (Vented) MASTER BEDRO 30 Blown 224 ft2 0.1 Wood 2 Under Attic (Vented) WIC 30 Blown 63 112 0.1 Wood 3 Under Attic (Vented) MASTER BATH 30 Blown 66,112 0.1 Wood 4 Under Attic (Vented) M. BATH 30 Blown 61 ft2 0.1 Wood _ 5 Under Attic (Vented) LAUDRY 30 Blown 36.ft2 0.1 Wood _ 6 Under Attic (Vented) BEDROOM 2 30 Blown 180 ft' 0.1 Wood _ 7 Under Attic (Vented) DINING/GREAT 30 Blown 588 ft2 0.1 Wood _ 8 'Under Attic (Vented) KITCHEN 30 Blown 209 ft2 0.1: Wood 9 Under Attic (Vented) BATH 30 Blown 50 ft2 0.1 Wood 10 Under Attic (Vented) HALL 30 Blown 25ft2 0.1 Wood 11 Under Attic (Vented) FOYER 30 Blown 92 ft2 0.1 Wood _ 12 Under Attic (Vented) BEDROOM 3 30 Blown 169 ft' 0.1 Wood 13 Knee Wall (Vented) DINING/GREAT 19 Blown 30 ft2 0.11 Wood WALLS Adjacent Space Cavity Width Height Sheathing Framing Solar Below 0 _ 1 E Exterior Concrete Block- Int InsAlASTER BE 4.1 16 0 8 0 128.0 112 0 0 0.3 0 —2 W Extedor Concrete Block- Int Ins6IASTER BE 4.1 7 0 8 0 56.0 ft' 0 0 0.3 _ 0 3 S Exterior Concrete Block - Int InsIMASTER BE 4.1 14 0 8 0 112.0 ft' 0 0 0.3 0 1/8/2020 4:43 PM EnergyGauge® USA 6.0.02'(Rev. 1) - FlaRes2017FBC 6th Edition (2017) Compliant Software Page 3 of 6 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT WALLS Adjacent Space -Cavity Width Height Sheathing' Framing Solar Below -4 E Exterior Concrete Block- Int InsOIASTER BA 4.1 8 0 8 0 64.0 ft2 0 0 0.3 0 _ 5 E Exterior Concrete Block- Int Insul M. BATH 4.1 7 0 8 0 56.0 ft2 0 0 0.3 0 -6 E Exterior Concrete Block- Int InsBEDROOM 2 4.1 12 0 8 0 96.0 ft2 0 0 0.3 0 -7 S Exterior Concrete Block- Int InsWINING/GRE 4.1 30 0 8 0 240.0 ft2 0 0 0.3 0 -8 W Exterior Concrete Block - Int InsiDINING/GRE 4.120 0 8 0 160.0 ft2 0 0 0.3 0 _ 9 W Exterior Concrete Block- Int InsuIKITCHEN 4.1 11 0 8 0 88.0 ft2 0 0 0.3 0 _ 10 E Exterior Concrete Block- Int Insul BATH 4.1 5 0 8 0 40.0 ft2 0 0 0.3 0 _ 11 N Exterior Concrete Block - Int Insul FOYER 4.1 8 0 8 0 64.0 ft2 0 0 0.3 0 _ 12 N Exterior Concrete Block- Int Insul FOYER 4.1 1 0 8 0 8.0 ft2 0 0 0.3 0 13 W Exterior Concrete Block- Int Ins8EDR00M 3 4.1 13 0 8 0 . 104.0 ft2 0 0 0.3 0 14 N Exterior .Concrete Block - Int InsENEDROOM 3 4.1 1 0 8 0 8.0 ft2 0 0 0.3 0 15 N Garage Frame - Wood BEDROOM 3 11 26 8 208.0 ft2 0.23 0.3 0 DOORS # Omt Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 N Insulated FOYER None .32 3 3 6 8 21.7 ft2 WINDOWS Orientation shown is the entered orientation => chan ed to Worst Case. Wall Overhang V # Omt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 S 3 Metal Low-E Single Yes 1.04 0.29 N 32.4112 1 ft 0 in 1 It 5 in Drapes/blinds Exterior 5 2 E 5 Metal Low-E Single Yes 1.04 0.29 N 6.9.ft2 1 It 0 in 1 ft 5 in None None 3 E 6 Metal Low-E Single Yes 1.04 0.29 N 16.2 ft2 1 It 0 in 1 It 5 in None None 4 S 7 .Metal Low-E Single Yes 1.04 0.29 N 39.8 112 1 ft 0 in 1 ft 51n None None 5 W 8 Metal Low-E Single Yes 1.11 0.27 N 40.0 ft2 8 ft 0 In 1 ft 5 in None None 6 W 13 Metal Low-E Single Yes 1.04 0.29 N 16.2 fl21 ft 0 in 1 ft 5 in Drapes/blinds Exterior 5 GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height 'Exposed Wall Insulation 1 806 ft2 806 ft2 26 It 8 It 11 INFILTRATION # Scope Method SLA CFM 50 . ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000254 1168.7 64.16 120.66 .0881 5 1/8/2020 4:43 PM EnergyGaugeS-USA 6.0.02. (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 4 of 6 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT HEATING SYSTEM # System Type Subtype Speed Efficiency Capacity Block Ducts 1 Electric Heat Pump/ Split Singl HSPFi8.5 34.8 kBlulhr 1 sys#1 COOLING SYSTEM # System Type Subtype Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/ Split Sing[ SEER: 15 34.8 kBtu/hr cfm 0.85 1 sys#1 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SeWnt Conservation 1 Electric None Garage 0.97 40 gal 60.9 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Collector Storage Cart # Company.Name System Model # Collector Model # Area Volume FEF None None g2 DUCTS Supply— —Return Air CFM 25 CFM25 HVAC# V # Location R-Value Area Location Area Leakage Type Handler TOT OUT ON RLF Heat Cool 1 Attic 6 175 ft2 Attic 55 ft2 Default Leakage Attic (Default) (Default) 1 1 TEMPERATURES Programable Thermostat: Fans:Cooling CrFeb Jan 'IY Mar Venting Jan Feb Mar Areiling Apr, D0 D( JMe un f ] Jul f � Aug �X r i Sep r00' Nov Dec [ ] X [ May Jun [ 1 Jul [ Aug [ Sep Oct (X] Nov Dec Thermostat Schedule: HERS 2006 Reference 'Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 - 78 78 78 78 78 78 78 78 78 78 78 Heating (WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating (WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 -PM 68 68 68 68 68 68 68 68 68 68 66 66 MASS Mass Type Area Thickness Furniture Fraction Space Default(8 lbs/sq.ft. 0 ft2 0 ft 0.3 BEDROOM Default(8lbslsq.ft. ft2 ft 0.3 WIC Default(8 Ibs/sq.ft. ft2 ft 0.3 M. BATH Default(81bs/sq.ft. ft2 ft 0.3 KITCHEN Default(8lbs/sq.ft. ft2 ft 0.3 BATH Default(8lbs/sq.ft. ft2 ft 0.3 BEDROOM 2 Default(8lbs/sq.ft. ft2 ft 0.3 ENTRY Default(8 lbs/sq.fL ft2 ft 0.3 LAUNDRY 1/8/2020 4:43 PM EnergyGaugeS USA 6.0.02. (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 5 of 6 -FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT MASS Mass Type Area Thickness Furniture Fraction Space Default 8lbs/s .ft. ft. ft 0:3 GREAT/DINING 1/8/2020 4:43 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 6 of 6 2017 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA TABLE 402.4.1.1 AIR BARRIER AND INSULATIOWNSPECTION COMPONENT CRITERIA Project Name: WYNNE THE WINDSOR IMPACT Builder Name: WYNNE DEVELOPMENT Street: Permit Office: ST. LUCIE COUNTY City, State, Zip: FT. PIERCE, FL, Permit Number: Y U Owner: Jurisdiction: w x Design Location: FL, Fart Pierce ci COMPONENT AIR BARRIER CRITERIA. INSULATION INSTALLATION CRITERIA General Acontinuous air barrier shall be installed in the building envelope. Air -permeable insulation shall requirements The exterior thermal envelope contains a continuous air barrier. not be used as a sealing material. Breaks or joints in the air barrier shall be sealed. Ceiling/attic The air barrier in any dropped ceiling/soft shall be aligned with The Insulation in any dropped ceiling/soffit the insulation and any gaps in the air barrier shall be sealed. shall be aligned with the air barrier. Access openings, drop down stairs or knee wall doors to unconditioned atfic spaces shall be sealed. Walls The junction of the foundation and sill plate shall be sealed. Cavities within comers and headers of frame walls The junction of the top plate and the top of exterior walls shall be shall be Insulated by completely filling the cavity sealed. with a material having a thermal resistance of R-3 Knee walls shall be sealed. per Inch minimum. Exterior thermal envelope insulation for framed walls shall be Installed in substantial contact and continuous alignment with the air barrier. Windows, skylights The space between window/doorjambs and framing, and and doors skylights and framing shall be sealed. Rim joists Rim joists shall include the air barder. Rim joists shall be insulated. Floors The air barrier shall be installed at any exposed edge of Floor framing cavity insulation shall be Installed to (including insulation. maintain permanent contact with the underside of above -garage subfioor decking, or floor framing cavity insulation and cantilevered shall be permitted to be in contact with the top side floors) of sheathing, or continuous insulation installed on the underside of floor framing and extends from the .bottom to the top of all perimeter floor framing members. Crawl space walls Exposed earth in unvented crawl spaces shall be covered with Where provided instead of floor insulation, insulation a Class I vapor retarder with overlapping joints taped. shall be permanently attached to the crawlspace Shafts, penetrations Duct shafts, utility penetrations, and flue shafts opening to exterior or unconditioned space shall be sealed. Batts in narrow cavities shall be cut to fit, or narrow Narrow cavities cavities shall be filled by insulation that on installation readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spa s. Recessed lighting Recessed light fixtures installed in the building thermal envelope Recessed light fixtures Installed In the building shall be sealed to the drywall. thermal envelope shall be airtight and IC rated. Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring and plumbing in exterior walls, or Insulation that on installation readily conforms to available space shall Shower/tub The air barrier installed at exterior walls adjacent to showers and Exterior walls adjacent to showers and tubs shall on exterior wall tubs shall separate them from the showers and tubs. be Insulated. Electricalfphone box or The air barrier shall be installed behind electrical or communication exterior walls boxes or air -sealed boxes shall be Installed. HVAC register boots HVAC register boots that penetrate building thermal envelope shall be sealed to the sub -floor or drywall. Concealed When required to be sealed, concealed fire sprinklers shall only be J sprinklers sealed in a manner that is recommended by the manufacturer. I Caulking or other adhesive sealants shall not be used to fill voids between fire sprinkler cover plates and walls or cellinas I a. In addition, inspection of log walls shall be in accordance with the provisions of ]CC-400. 1/8/2020 4A3 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1 2017 EPL DISPLAY CARD ENERGY PERFORMANCE, LEVEL (EPL) DISPLAY.CARD ESTIMATED ENERGY PERFORMANCE INDEX" = 97 The lower the Energy Performance Index, the more efficient the home. 1. New home or, addition 1. New (From Plans) 12. Ducts, location $ insulation level a) Supply ducts' R 6.0 2. Single-family or multiple -family 2. Single-family b) Return ducts R 6.0 c) AHU location Attic 3. No. of units (if multiple -family) 3. 1 4. Number of bedrooms 4. 3 13. Cooling system: Capacity 34.8 a)Split system . SEER 15.0 5. Is this a worst case? (yes/no) 5. Yes b) Single package SEER c) Ground/water source SEER/COP 6. Conditioned floor area (sq. ft.) 6. 1753 d) Room unitIPTAC EER e) Other 7. Windows, type and area a) U-factor:(weighted average) 7a. 1.058 b) Solar Heat Gain Coefficient(SHGC) 7b. 0.285 14. Heating system: Capacity 34.8 c) Area 7c. 151.4 a) Split system heat pump HSPF 8.5 b) Single package heat pump HSPF 8. Skylights c) Electric resistance COP a) U-factor.(weighted average) 8a. NA d) Gas furnace, natural gas AFUE b) Solar Heat Gain Coefficient (SHGC) 8b. NA e) Gas furnace, LPG AFUE f) Other 9. Floor type, insulation level: a) Slab -on -grade (R-value) 9a. 0.0 b) Wood,. raised (R-value) 9b. 15. Water heating system c) Concrete, raised (R-value) 9c. a) Electric resistance EF 0.97 b) Gas fired, natural gas EF 10. Wall type and insulation: c),Gas fired, LPG EF A. Exterior: d) Solar system with tank EF 1. Wood frame (Insulation R-value) 10A1. e) Dedicated heat pump with tank EF_ 2. Masonry (Insulation R-value) 10A2. 4.1 0 Heat recovery unit HeatRec% B. Adjacent: g) Other 1. Wood frame (Insulation R-value) 10B1. 11.0 2. Masonry (Insulation R-value) 10B2. 16. HVAC credits claimed (Performance Method) 11. Ceiling type and insulation level a) Ceiling fans a) Under attic 11 a. 30.0 b) Cross ventilation No b) Single assembly 11 b. c) Whole house fan No c) Knee walls/skylight walls 11c. 19.0 d) Multizone cooling credit d) Radiant barrier installed 11d. No e) Multizone heating credit f) Programmable thermostat Yes 'Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT I certify that this home has complied with the Florida Building Code, Energy Conservation, through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL display card will be completed based on installed code compliant features. Builder Signature: (�� l^' _ Date: Address of New Home:�� LJ. r-ir AC �91 Wy t� City/FL Zip: FT. PIERCE, FL>'tr> L13CI 1/8/2020 4:43:52 PM EnergyGauge® USA 6.0.04 (Rev. 1) - FlaRes2017 FBCBth Edition (2017) Compliant Software Page 1-of 1