Loading...
HomeMy WebLinkAboutWind Load Calculation WINDOW • OPENING INFORIWk— TION A FLOOR PLAN WITH OPENING IDENTIFICATION SHOULD BE PROVIDED WITH THIS SHEET Definition of Comer Zone-10%of least horizontal dimension or 40%of the mean roof height,whichever is smaller,but not less than 4%of least horizontal dimension or 3 ft. PRODUCT APPROVAL REQUIRED OPENING MAXIMU MULTIPLE OPENING (Location) IS THIS A PRODUCT ROUGH ARE GLAZING APPROVED PRESSURE RATING DESIGN PRESSURE M WINDOW LOCATION Corner Zone WINDOW ACCEPTANCE OPENING SHUTTERS NUMBER or Interior OR DOOR TYPE NUMBER + PSF + PSF TESTED MULLION ( ) (-)PSF ( ) (-)PSF SIZE DIMENSIONS REQ Y/N REQ Y/NINA 1 End window 7/8"Lami 20-0109.04 55 55 37.8 -50.6 60 x 60 24x36 No No 2 Int Window 7/8"Lami 18-0911.05 55 55 36.2 -39.5 52 x 75 51x53 No No 3 Int Window 7/8"Lami 18-0911.05 55 55 36.2 -39.5 52 x 75 51x53 No No 4 Int Window 7/8"Lami 18-0911.04 55 55 35.1 -38.3 74 x 63 72x61 No No 5 Int Window 7/8"Lami 18-0911.05 55 55 37.8 -41.0 52 x 75 2507 No No 6 Int Window 7/8"Lami 20-0506.03 55 55 36.8 -40.0 36 x 68 35x61 No No 7 Int Window 7/8"Lami 20-0506.03 55 55 36.8 -40.0 36 x 68 35x61 No No 8 Int Window 7/8"Lami 20-0109.04 55 55 37.8 -41.0 60 x 60 2506 No No J N 29 ::0211