HomeMy WebLinkAboutEnergy CodeFORM R405-2017
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
ProjectName: WYNNE THE STERLING IMPACT
BuilderName: WYNNE DEVELOPMENT
Street: THE STERLING
Permit Office: ST. LUCIE COUNTY
City, State, Zip: FT. PIERCE, FL,
PermitNumber:
Owner. N \
Jurisdiction:
Designt-ocaticn: FL, Fort Pierce
County: St. Lucie (Florida Climate Zone 2 )
1. New construction or existing New (From Plans)
9..Wall Types (1442.0 sqft.)
Insulation Area
2. Singlefamilyormultiple family Single-family
a. Concrete Block- Int lnsul, Exterior
R=4.1 1250.00 ft-
3. Number of units, if multiple family 1
b. Frame - Wood, Adjacent
R=11.0 192.00 fN
c. NIA
R= ft=
4. Numberof Bedrooms 2
d•N/A
R= fP
5. Is this a worst case? Yes
IO.Ceiling Types (1504.0 sqft.)
Insulation Area
a. UnderAtlic(Vented)
R=30.0 1474.Ooft-
6. Conditioned floorarea above grade(W) 1474
b. Knee Wall (Vented)
R=19.0 30.00 ft=
Conditioned floorarea beiowgrade(ft=) 0
c. N/A
R= ff=
11. Ducts
R fN
7. Windows(141.3 sqft.) Description Area
a. Sup: Attic, Ret Attic, AH: Attic
6 175
a. U-Factor. Sgl, U=1.04 101.25 ft-
SHGC: SHGC=0.29
b. U-Factor. SgI,U=1.11 40.00 ft-
12. Cooling systems
kBtulhr Efficiency
SHGC: SHGC=0.27
a. Central Unit
34.8 SEER:15.00
c. U-Factor. WA f6
SHGC:
13. Heating systems
kBtuRv Efficiency
d. U-Factor. N/A ft-
a. Electric Heat Pump
34.8 HSPF:8.50
SHGC:
Area Weighted Average Overhang Depth: 3.832 ft.
Area Weighted Average SHGC: 0.284
14. Hotwater systems
8. FloarTypes (1473.5 sqft.) Insulation Area
a. Electric
Cap; 50 gallons
a. Slab -On -Grade Edge Insulation R=0.0 1473.50 ft-
b. Conservationfealures
EF: 0.970
b. N/A R= ft.
None
c. N/A R= ft-
15. Credits
Pstat
Glass/Floor Area: 0.096 Total Proposed Modified Loads: 47.94
PASS
Total Baseline Loads: 46.55
I hereby certify that the plans and specifications covered by
Review of the plans and
this calculation are in compliance with the Florida Energy
specifications covered by this
Code.
calculation indicatescompliance
with the Florida Energy Code.
rq/y
PREPARED j3Y
Before construction is completed
DATE: 0-
this building will be inspected for
compliance with Section 553.908
fi p
I hereby certify that this building, as design mpliance
Florida Statutes.
with the Florida Energy Code.�i®�
OWNER/
BUILDING OFFICIAL:
DATE:
DATE:
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory -sealed In accordance with R403.3.2.1.
- Compliance requires an Air Barrier and Insulation Inspection C�q p02.4.1.1 and this project requires
an envelope leakage test report with envelope leakage no greate an Apq ?AWbE
C0E)E COM lr
IT. LUCIE COUNTY
BOCC
412012020 3:04 PM EnergyGauge®USA 6.0.02(Rev.1)-FlaRes2017FBC6thEdition (2017)CompliantSoftware Page Iof5
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
PROJECT
Title: WYNNE THE STERLING IMP Bedrooms: 2
Address Type:
Street Address
Building Type: User
ConditionedArea: 1474
Lot#
OwnerName:
TotalStories: 1
Block/Subdivision:
#of Units: 1
Worst Case: Yes
PlatBook:
BuilderName: WYNNE DEVELOPMENT RotateAngle: 180
Street:
THE STERLING
Permit Office: ST. LUCIE COUNTY
CrossVentilation: No
County.
St. Lucie
Jurisdiction:
Whole House Fan: No
City, State, Zip:
FT. PIERCE,
FamilyType: Single-family
FL
NewlEAsting: New(From Plans)
Comment:
CLIMATE
/
Design Temp
Int Design Temp Heating
Design
DallyTemp
V Designi-ocaflon
TMYSite 97.5% 2.5%
Winter
Summer DegreeDays Moisture
Range
FL, Fort Pierce FL_VERO_BEACH_MUNI 39 90
70
75 . 299
62
Low
BLOCKS
Number Name
Area Volume
1 Entire House
1474 11792
SPACES
Number Name
Area Volume Kitchen Occupants
Bedrooms
Infil ID Flnished Cooled
Heated
1 BEDROOM
329 2632 No 0
1
1 Yes
Yes
Yes
2 WIC
63 504 No 0
1 .No
Yes
Yes
3 M.BATH
56 448 No 0
1 Yes
Yes
Yes
4 KITCHEN
192 1536 Yes 0
1 No
Yes
Yes
5 BATH
45 360 No 0
1 Yes
Yes
Yes -
6 BEDROOM 2
204 1632 No 0
1
1 Yes
Yes
Yes
7 ENTRY
55 440 No 0
1 Yes
Yes
s
Yes
8 LAUNDRY,
42 336 No 0
1 Yes
Yes
Yes
9 GREAVDINING
488 3904 No 0.
1 Yes
Yes
Yes
FLOORS
# FldorType
Space Perimeter PerimeterR-Value
Area
JoistR-Value
Tile Wood
Carpet
1 Slab=On-Grade Edge Insulation
BEDROOM 52ft 0
329 ft2
----
0 1
0
2 Slab -On -Grade Edge Insulation
WIC 1ft 0
63 fN
----
0 1
0
3 Slab -On -Grade Edge Insulation
M.BATH 8ft 0
56 ft2
_---
0 1
0
4 Slab•On•GradeEdgelnsulation
KITCHEN 1 ft 0
192 ft2
0 1
0
5 Slab -On -Grade Edge Insulation
BATH 5ft 0
45 fN
----
0 1
0
6 Slab-On•GradeEdgelnsulafion
BEDROOM 32.2ft 0
203.5 ft2
.---
0 1
0
7Slab•On-Grade Edge Insulation
ENTRY 7ft 0
55ft2
----
0 1
0
4/20/2020 3:04 PM EnergyGaugeS USA 6.0.02 (Rev. 1)- FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 2 of 5
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
FLOORS
# FloorType Space Perimeter PerimeterR-Value
Area
JolstR-Value
Tile
Wood Carpet
8SIab-On-GradeEdgelnsulation LAUNDRY Eft 0
42 ft-
----
0
1
0
9 Slab -On -Grade Edge Insulation GREAT/DINING 46ft 0
488 ft2
----
0
1
0
ROOF
. / Roof
Gable
Roof
Red
Solar
SA Emitt Emitt Deck
Pitch
V # Type Materials Area
Area
Color
Barr
Absor.
Tested
Tested Insul.
(deg)
1 GableorShed Metal 1553 ft2
246 ft2
Light
N
0.6
No
0.9
No 0
18A
ATTIC
/
V # Type Ventilation
Vent Ratio (1 in)
Area
RBS
IRCC
1 Fullatuc Vented
150
1474 ft2
N
N
CEILING
# CeilingType Spac�
R-Value
Ins Type
Area
Framing Frac
Truss Type
1 UnderAttic(Vented) -BEDROOM
30
Blown
329 ft2
0.1
Wood
2 UnderAftic(Vented) WIC
30
Blown
63 ft'
0.1
Wood
3 UnderAttic(Vented) M.BATH
30
Blown
56 ft'
0.1
Wood
4 UnderAttic(Vented) KITCHEN
30
Blown
192.ft-
0.1
Wood
5 UnderAttic(Vented) BATH
30
Blown
45 fP
0.1
Wood
6 UnderAttic(Vented) BEDROOM
30
Blown
204 ft2
0.1
Wood
7 UnderAt6c(Vented) ENTRY
30
Blown
55 ft'
0.1
Wood
8 UnderAttic(Vented) LAUNDRY
30
Blown
42 ft-
0.1
Wood
9 UnderAttic(Vented) GREAT/DINING
30
Blown
488 ft2
0.1
Wood
10 Knee Wall (Vented) BEDROOM
19
Blown
30 ft2
0.11
Wood
WALLS
Adjacent Space Cavity Width
Height
Sheathing Framing
Solar Below
0
1 NE -->SW Exterior Concrete Block- Int Insul BEDROOM
4.1 10
0 8
0
80.0 ft2
0
0
OA
0
_2 SW=>NE Exterior Concrete Block- Int Insul BEDROOM
4.1 28
0 8
0
224.0 ft2
0
0
OA
0
_3 NW=>SE Exterior Concrete Block- Int Insul BEDROOM
4.1 14
0 8
0
112.0 ft2
0
0
OA
0
_4 SW=>NE Exterior Concrete Block-Int Insul M.BATH
4.1 8
0 8
0
64.0 ft2
0
0
0.4
0
5 NE=>SW Exterior Concrete Block- Int Insul BATH
4.1 5
0 8
0
40.0 ft2
0
0
0.4
0
_6 NE=>SW Exterior Concrete Block- Int InsuBEDROOM 2
4,1 16
0 8
0
128.0 ft'
0
0
0.4
0
7 SE=>NW Exterior Concrete Block- Int InsuBEDROOM 2
4,1 10
0 8
0
80.0 ft'
0
0
0.4
0
_ 8 S=>N Exterior Concrete Block- Int InsuBEDROOM 2
4.1 4
3 8
0
34.0 ft2
0
0
0.4
0
-9 SW=>NE Exterior Concrete Block- Int InsuBEDROOM 2
4.1 2
0 8
0
16.0 ft2
0
0
OA
0
10 SE=>NW Exterior Concrete Block-Intlnsul ENTRY
4.1 6
0 8
0
48.0 112
0
0
0.4
0
_11 SW ->NE Exterior Concrete Block-Intinsul ENTRY
4.1 1
0 8
0
8.0 ft2
0
0
0.4
0
_12 SW=>NE Exterior Concrete Block-Intlnsul LAUNDRY
4.1 6
0 8
0
48.0 ft2
0
0
OA
0
_13 NE=>SW Exterior Concrete Block -Int lnsuI3REAT/DIN1
4.1 26
0 8
0
208.0 ft2
0
0
0.4
0
14 NW=>SE Exterior Concrete Block -Int lnsulGREAT/DINI
4.1 20
0 8
0
160.0 ft'
0
0
0.4
0
4120/20203:04 PM EnergyGauge®USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition(2017) Compliant Software Page 3of5
FORM R405-2017 INPUT SUMMARY: CHECKLIST REPORT
WALLS
Adjacent
Space Cavity Width
Height
Sheathing Framing Solar pelow
_15 N=>S Garage Frame -Wood
KITCHEN 11 24 8
192.0 ft'
0.23 0.4
0
DOORS
# Omt
DoorType
Space Storms
U-Value
Ft
Width Height
In Ft In
Area
1 SE=>NW
Insulated
ENTRY None
.39 3
1 6 8
20.6ft-
_ / Wall
V # Ornt ID Frame
WINDOWS
Orientation shown Is the entered orientation => changed to Worst Case.
Overhang
Panes NFRC U-Factor SHGC Imp Area Depth Separation ' IntShade
Screening
1 NW=>SE 3 Metal
2 SW=>NE 4 Metal
3 SE=>NW7 Metal
4 NE=>SW 13 Metal
5 NW=>SE14 Metal
Low-ESingle
Low-ESingle
Low-ESingle
Low-ESingle
Low-ESingle
Yes 1.04 0.29 N
Yes 1.04 0.29 N
Yes 1.04 0.29 N
Yes 1.04 0.29 N
Yes 1.11 0.27 N
32.9 ft' 1 ft0 in-
6.9 ft' 1 ft 0 in
24.0 ft' 6ft0 in
37.5 ft' 1 ft 0 in
40.0 ft' 8ft0 in
1 ft 5 in Drapes/blinds
1 ft 5 in None
1ft5 in None
1 ft 5 in None
1ft5in Drapeslblinds
Exteriors
None
None
None
Fxterlor5
GARAGE
# FloorArea
CeilingArea Exposed Wall Perimeter
Avg. Wall Height
ExposedWalllnsulation
1 315 ft'
315 ft- 24ft
_81t
11
INFILTRATION
# Scope Method
SLA CFM 50 ELA EgLA ACH
ACH 50
1 Wholehouse ProposedACH(50)
.000356 1375.7 75.53 142.04 .1233
7
HEATING SYSTEM
# System Type
Subtype Speed Efficiency
Capacity
,Block
Ducts
1 Electric Heat Pump/
Split Single HSPF:8.5
34.8 kBtulhr
1
sys#1
COOLING SYSTEM
# SystemType
Subtype Subtype Efficiency
Capacity Air Flow SHR Block
Ducts
1 CentralUnitl
Split Single SEER:15
34.8 kBtulhr clin 0.85 1
sys#1
HOT WATER SYSTEM
# System Type
SubType
Location EF Cap
Use SetPnt
Conservation
1 Electric
None
Garage 0.97 50gal 60.9gal 120deg
None
4/20/20203:04 PM EnergyGauge®USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition(2017) Compliant SAvare Page 4of5
FORM R405-2017 INPUT SUMMARY. CHECKLIST REPORT
SOLAR HOT WATER SYSTEM
FSEC
Collector Storage
Cart # CompanyName
System
Model#
Collector Model#
Area Volume
FEF
None None
ft2
DUCTS
_ / —Supply-
Return
Air
CFM 25
CFM25
HVAC#
V # Location R-Value Area
Location
Area
LeakageType
Handler
TOT
OUT ON
RLF
Heat Cool
1 Attic
6 175 ft2
Attic
65 ft2
DefaultLeakage .
Attic
(Default) c(Default) c
1 1
TEMPERATURES
PmgmmablereTO,hennostat: Y
Ceiling Fans:
Venting HFeb
r00,
NMar
Apr
€
Jun
D0
[ ]Jul
[XJ
[ ]Aug
D'0
[ ]Sep
[ ]
LJ
[ ],Jan
May
Jun
[)Jul
[)Aug
I 1 Sep
lxl Qc
Nov
Dec
ThermostatSchedule: HERS 2006 Reference
Hours
Schedule Type
1
2
3
4
5
6
7
8
9 10
11
12
Cooling (WD)
80
80
78
78
78
PM
78
78
78
78 78
78
78
Cooling (WEH) PM
78
78
78
78
78
78
78
78
78 78
78
78
Heating(WD) AM
66
66
66
66
66
68
68
68
68 68
68
68
PM
68
68
68
68
68
68
68
68
68 68
fib
66
Heating(WEH) AM
66
66
66
66
66
68
68
68
68 68
68
68
PM
68
68
68
68
.68
68
68
68
68 68
66
66
MASS
Mass Type
Area
Thickness
FumitureFraction
Space
Default(8lbs/sq.ft.
0 ft2
Oft
0.3
1BEDROOM
Default(8lbs/sq.ft.
ft2
ft
0.3
WIC
Default(8lbs/sq.ft.
ft2
ft
0.3
M. BATH
Default(816s/sq.ft.
ft2
ft
0.3
KITCHEN
Default(81bs/sq.ft
ft2
It
0.3
BATH
Defaull(Blbs/sq.ft.
ft2
ft
0.3
BEDROOM
Default(8 lbs/sq.ft.
ft2
ft
0.3
ENTRY
Default(8lbs/sq.ft.
ft2
ft
0.3
LAUNDRY
Default 81bs/s .ft..
ft2,
ft
0.3
GREAT/DINING
4/202020 3:04 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 5 of 5
2017 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
TABLE 402.4.1.1
AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
Project Name: WYNNE THE STERLING IMPACT Builder Name: WYNNE DEVELOPMENT
Street: THE: STERLING Permit Office: ST. LUCIE COUNTY '
City, State, Zip: FT. PIERCE, FL, Permit Number:
x
Owner. Jurisdiction:
w
Design Location: FL, Fort Pierce
=
U
COMPONENT
AIR BARRIER CRITERIA
INSULATION INSTALLATION CRITERIA
General
A continuous air barrier shall be installed in the building envelope.
Alr-permeable insulation shall
requirements
The exterior thermal envelope contains a continuous air barrier.
not be used as a sealing material.
Breaks or joints in the air barrier shall be sealed.
'Ceilinglattic
The air barter in any dropped ceiling/soffit shall be aligned with
The insulation in any dropped ceiling/soffit
the insulation and any gaps in the air barrier shall be sealed.
shall be aligned with the air barrier.
Access openings, drop down stairs or knee wall doors to
unconditioned attics aces shall be sealed.
Walls
The junction of the foundation and sill plate shall be sealed.
Cavities within comers and headers of frame walls
•
The Junction of the tap plate and the top of exterior walls shall be
shall be Insulated by completely filling the cavity
sealed.
with a material having a thermal resistance of R-3
Knee walls shall be sealed.
per inch minimum.
Exterior thermal envelope Insulation for framed
.
walls shall be installed in substantial contact and
continuous alignment with the air barter.
Windows, skylights
The space between window/doorjambs and framing, and
and doors
skylights and framing shall be sealed.
Rim joists
Rim joists shall Include the air barrier.
Rim joists shall be insulated.
Floors
The air barrier shall be installed at any exposed edge of
Floor framing cavity insulation shall be installed to
(including
insulation.
maintain permanent contact with the underside of
above -garage
subffocr decking, or floor framing cavity insulation
and cantilevered
shall be permitted to be in contact with the top side
floors)
of sheathing, or continuous Insulation installed on
the underside of floor framing and extends from the
bottom to the top of all perimeter floor framing
members.
Crawl space walls
Exposed earth in unvented crawl spaces shall be covered with
Where provided Instead of floor insulation, insulation
a Class I vapor retarder with overlapping joints taped.
shall be permanently attached to the crewlspace
Shafts, penetrations
Duct shafts, utility penetrations, and flue shafts opening to
exterior or unconditioned space shall be sealed.
Batts in narrow cavities shall be cut to fit, or narrow
Narrow cavities
cavities shall be ,filled by insulation that on
installation readily conforms to the available cavity
spaces.
Garage separation
Air sealing shall be provided between the garage and conditioned spa
s.
Recessed lighting
Recessed light fixtures installed in the building thermal envelope
Recessed light fixtures installed In the building
shall be sealed to the drywall.
thermal envelope shall be air light and IC rated.
Plumbing and wiring
Batt Insulation shall be cut neatly to. fit around wldng
and plumbing in exterior walls, or insulation that on
installation readily conforms to available space shall
extend behind nininn and wirina
Shower/tub
The air barrier installed at exterior walls adjacent to showers and
Exterior walls adjacent to showers and tubs shall
on exterior wall
tubs shall separate them from the showers and tubs.
be insulated.
Electrical/phone box oi
The air barrier shall be installed behind electrical or communication
exterior walls
boxes or air -sealed boxes shall be Installed.
HVAC register boots
HVAC register boots that penetrate building thermal envelope shall
be sealed to the sub -floor or drywall.
Concealed
When required to be sealed, concealed fire sprinklers shall only be
sprinklers
sealed In a manner that is recommended by the manufacturer.
Caulking or other adhesive sealants shall not be used to fill voids
a. In addition, Inspection of log walls shall be In accordance with the provisions of ICC-400.
4/20/2020 3:05 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1
2017 EPL DISPLAY CARD
ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 99
The lower the Energy
Performance Index,
the more efficient the home.
1. New home or, addition
1. New (From Plans)
12. Ducts, location & insulation level
a) Supply ducts R
6.0
2. Single-family or multiple -family
2. Single-family
b) Return ducts FL
6.0
c) AHU location
Attic
3. No. of units (ifmultiple-family)3.
1
4. Number of bedrooms
4.
2
13. Cooling system: Capacity
34.8
5. Is this a worst case? (yes/no)
5.
Yes
a) Split system SEER.
b) Single package SEER
15.0
c) Ground/water source SEERICOP
6. Conditioned floor area (sq. ft.)
6.
1474
d) Room unit/PTAC EER
e) Other
7. Windows, type and area
a) U-factor:(weighted average)
7a.
1.060
b) Solar Heat Gain Coeffiicient(SHGC)
7b.
0.284
14. Heating system: Capacity
34.8
c) Area
7c.
141.3
a) Split system heat pump HSPF
8.5
b) Single package heat pump HSPF
8. Skylights
c) Electric resistance COP
a) U-factor:(weighted average)
8a.
NA
d) Gas furnace, natural gas AFUE
b) Solar Heat Gain Coefficient (SHGC)
8b.
NA
e) Gas furnace, LPG AFUE
0 Other
9. Floor type, insulation level:
a) Slab -on -grade (R-value)
9a.
0.0
b) Wood, raised (R-value)
9b.
15. Water heating system .
c) Concrete, raised (R-value)
9o.
-
a) Electric resistance EF
0.97
b) Gas fired, natural gas EF
10. Wall type and insulation:
c) Gas Fred, LPG EF
A. Exterior:
d) Solar system with tank EF
1. Wood frame (Insulation R-value)
10A1.
e) Dedicated heat pump with tank EF_
2. Masonry (Insulation R-value)
10A2.
4.1
f) Heat recovery unit HeatRec0/a
B. Adjacent:
g) Other
1. Wood frame (Insulation R-value)
10B1.
11.0
2. Masonry (Insulation R-value)
10B2.
16. HVAC credits claimed (Performance Method)
11. Ceiling type and insulation level
a) Ceiling fans
a) Under attic
11a.
30.0
b) Cross ventilation
No
b) Single assembly
111b.
c) Whole house fan
No
c) Knee walls/skylight walls
11c.
19.0
d) Multizone cooling credit
d) Radiant barrier installed
11d.
No
e) Muitizone heating credit
f) Programmable thermostat
Yes
*Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT
I certify that this home has complied with the Florida Building Code, Energy Conservation, through the above energy
saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL
display card will be completed based on installed code compliant features. Builder Signature:_ ��� Date: k-`D-CA O^^``
�
Address of New Home: THE STERLING S� X y City/FL Zip: FT. PIERCE, FL S
4/20/2020 3:05:01 PM EnergyGaugeO USA 6.0.04 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1