Loading...
HomeMy WebLinkAboutEnergy CodeFORM R405-2017 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method ProjectName: WYNNE THE STERLING IMPACT BuilderName: WYNNE DEVELOPMENT Street: THE STERLING Permit Office: ST. LUCIE COUNTY City, State, Zip: FT. PIERCE, FL, PermitNumber: Owner. N \ Jurisdiction: Designt-ocaticn: FL, Fort Pierce County: St. Lucie (Florida Climate Zone 2 ) 1. New construction or existing New (From Plans) 9..Wall Types (1442.0 sqft.) Insulation Area 2. Singlefamilyormultiple family Single-family a. Concrete Block- Int lnsul, Exterior R=4.1 1250.00 ft- 3. Number of units, if multiple family 1 b. Frame - Wood, Adjacent R=11.0 192.00 fN c. NIA R= ft= 4. Numberof Bedrooms 2 d•N/A R= fP 5. Is this a worst case? Yes IO.Ceiling Types (1504.0 sqft.) Insulation Area a. UnderAtlic(Vented) R=30.0 1474.Ooft- 6. Conditioned floorarea above grade(W) 1474 b. Knee Wall (Vented) R=19.0 30.00 ft= Conditioned floorarea beiowgrade(ft=) 0 c. N/A R= ff= 11. Ducts R fN 7. Windows(141.3 sqft.) Description Area a. Sup: Attic, Ret Attic, AH: Attic 6 175 a. U-Factor. Sgl, U=1.04 101.25 ft- SHGC: SHGC=0.29 b. U-Factor. SgI,U=1.11 40.00 ft- 12. Cooling systems kBtulhr Efficiency SHGC: SHGC=0.27 a. Central Unit 34.8 SEER:15.00 c. U-Factor. WA f6 SHGC: 13. Heating systems kBtuRv Efficiency d. U-Factor. N/A ft- a. Electric Heat Pump 34.8 HSPF:8.50 SHGC: Area Weighted Average Overhang Depth: 3.832 ft. Area Weighted Average SHGC: 0.284 14. Hotwater systems 8. FloarTypes (1473.5 sqft.) Insulation Area a. Electric Cap; 50 gallons a. Slab -On -Grade Edge Insulation R=0.0 1473.50 ft- b. Conservationfealures EF: 0.970 b. N/A R= ft. None c. N/A R= ft- 15. Credits Pstat Glass/Floor Area: 0.096 Total Proposed Modified Loads: 47.94 PASS Total Baseline Loads: 46.55 I hereby certify that the plans and specifications covered by Review of the plans and this calculation are in compliance with the Florida Energy specifications covered by this Code. calculation indicatescompliance with the Florida Energy Code. rq/y PREPARED j3Y Before construction is completed DATE: 0- this building will be inspected for compliance with Section 553.908 fi p I hereby certify that this building, as design mpliance Florida Statutes. with the Florida Energy Code.�i®� OWNER/ BUILDING OFFICIAL: DATE: DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory -sealed In accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection C�q p02.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greate an Apq ?AWbE C0E)E COM lr IT. LUCIE COUNTY BOCC 412012020 3:04 PM EnergyGauge®USA 6.0.02(Rev.1)-FlaRes2017FBC6thEdition (2017)CompliantSoftware Page Iof5 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT PROJECT Title: WYNNE THE STERLING IMP Bedrooms: 2 Address Type: Street Address Building Type: User ConditionedArea: 1474 Lot# OwnerName: TotalStories: 1 Block/Subdivision: #of Units: 1 Worst Case: Yes PlatBook: BuilderName: WYNNE DEVELOPMENT RotateAngle: 180 Street: THE STERLING Permit Office: ST. LUCIE COUNTY CrossVentilation: No County. St. Lucie Jurisdiction: Whole House Fan: No City, State, Zip: FT. PIERCE, FamilyType: Single-family FL NewlEAsting: New(From Plans) Comment: CLIMATE / Design Temp Int Design Temp Heating Design DallyTemp V Designi-ocaflon TMYSite 97.5% 2.5% Winter Summer DegreeDays Moisture Range FL, Fort Pierce FL_VERO_BEACH_MUNI 39 90 70 75 . 299 62 Low BLOCKS Number Name Area Volume 1 Entire House 1474 11792 SPACES Number Name Area Volume Kitchen Occupants Bedrooms Infil ID Flnished Cooled Heated 1 BEDROOM 329 2632 No 0 1 1 Yes Yes Yes 2 WIC 63 504 No 0 1 .No Yes Yes 3 M.BATH 56 448 No 0 1 Yes Yes Yes 4 KITCHEN 192 1536 Yes 0 1 No Yes Yes 5 BATH 45 360 No 0 1 Yes Yes Yes - 6 BEDROOM 2 204 1632 No 0 1 1 Yes Yes Yes 7 ENTRY 55 440 No 0 1 Yes Yes s Yes 8 LAUNDRY, 42 336 No 0 1 Yes Yes Yes 9 GREAVDINING 488 3904 No 0. 1 Yes Yes Yes FLOORS # FldorType Space Perimeter PerimeterR-Value Area JoistR-Value Tile Wood Carpet 1 Slab=On-Grade Edge Insulation BEDROOM 52ft 0 329 ft2 ---- 0 1 0 2 Slab -On -Grade Edge Insulation WIC 1ft 0 63 fN ---- 0 1 0 3 Slab -On -Grade Edge Insulation M.BATH 8ft 0 56 ft2 _--- 0 1 0 4 Slab•On•GradeEdgelnsulation KITCHEN 1 ft 0 192 ft2 0 1 0 5 Slab -On -Grade Edge Insulation BATH 5ft 0 45 fN ---- 0 1 0 6 Slab-On•GradeEdgelnsulafion BEDROOM 32.2ft 0 203.5 ft2 .--- 0 1 0 7Slab•On-Grade Edge Insulation ENTRY 7ft 0 55ft2 ---- 0 1 0 4/20/2020 3:04 PM EnergyGaugeS USA 6.0.02 (Rev. 1)- FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 2 of 5 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT FLOORS # FloorType Space Perimeter PerimeterR-Value Area JolstR-Value Tile Wood Carpet 8SIab-On-GradeEdgelnsulation LAUNDRY Eft 0 42 ft- ---- 0 1 0 9 Slab -On -Grade Edge Insulation GREAT/DINING 46ft 0 488 ft2 ---- 0 1 0 ROOF . / Roof Gable Roof Red Solar SA Emitt Emitt Deck Pitch V # Type Materials Area Area Color Barr Absor. Tested Tested Insul. (deg) 1 GableorShed Metal 1553 ft2 246 ft2 Light N 0.6 No 0.9 No 0 18A ATTIC / V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Fullatuc Vented 150 1474 ft2 N N CEILING # CeilingType Spac� R-Value Ins Type Area Framing Frac Truss Type 1 UnderAttic(Vented) -BEDROOM 30 Blown 329 ft2 0.1 Wood 2 UnderAftic(Vented) WIC 30 Blown 63 ft' 0.1 Wood 3 UnderAttic(Vented) M.BATH 30 Blown 56 ft' 0.1 Wood 4 UnderAttic(Vented) KITCHEN 30 Blown 192.ft- 0.1 Wood 5 UnderAttic(Vented) BATH 30 Blown 45 fP 0.1 Wood 6 UnderAttic(Vented) BEDROOM 30 Blown 204 ft2 0.1 Wood 7 UnderAt6c(Vented) ENTRY 30 Blown 55 ft' 0.1 Wood 8 UnderAttic(Vented) LAUNDRY 30 Blown 42 ft- 0.1 Wood 9 UnderAttic(Vented) GREAT/DINING 30 Blown 488 ft2 0.1 Wood 10 Knee Wall (Vented) BEDROOM 19 Blown 30 ft2 0.11 Wood WALLS Adjacent Space Cavity Width Height Sheathing Framing Solar Below 0 1 NE -->SW Exterior Concrete Block- Int Insul BEDROOM 4.1 10 0 8 0 80.0 ft2 0 0 OA 0 _2 SW=>NE Exterior Concrete Block- Int Insul BEDROOM 4.1 28 0 8 0 224.0 ft2 0 0 OA 0 _3 NW=>SE Exterior Concrete Block- Int Insul BEDROOM 4.1 14 0 8 0 112.0 ft2 0 0 OA 0 _4 SW=>NE Exterior Concrete Block-Int Insul M.BATH 4.1 8 0 8 0 64.0 ft2 0 0 0.4 0 5 NE=>SW Exterior Concrete Block- Int Insul BATH 4.1 5 0 8 0 40.0 ft2 0 0 0.4 0 _6 NE=>SW Exterior Concrete Block- Int InsuBEDROOM 2 4,1 16 0 8 0 128.0 ft' 0 0 0.4 0 7 SE=>NW Exterior Concrete Block- Int InsuBEDROOM 2 4,1 10 0 8 0 80.0 ft' 0 0 0.4 0 _ 8 S=>N Exterior Concrete Block- Int InsuBEDROOM 2 4.1 4 3 8 0 34.0 ft2 0 0 0.4 0 -9 SW=>NE Exterior Concrete Block- Int InsuBEDROOM 2 4.1 2 0 8 0 16.0 ft2 0 0 OA 0 10 SE=>NW Exterior Concrete Block-Intlnsul ENTRY 4.1 6 0 8 0 48.0 112 0 0 0.4 0 _11 SW ->NE Exterior Concrete Block-Intinsul ENTRY 4.1 1 0 8 0 8.0 ft2 0 0 0.4 0 _12 SW=>NE Exterior Concrete Block-Intlnsul LAUNDRY 4.1 6 0 8 0 48.0 ft2 0 0 OA 0 _13 NE=>SW Exterior Concrete Block -Int lnsuI3REAT/DIN1 4.1 26 0 8 0 208.0 ft2 0 0 0.4 0 14 NW=>SE Exterior Concrete Block -Int lnsulGREAT/DINI 4.1 20 0 8 0 160.0 ft' 0 0 0.4 0 4120/20203:04 PM EnergyGauge®USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition(2017) Compliant Software Page 3of5 FORM R405-2017 INPUT SUMMARY: CHECKLIST REPORT WALLS Adjacent Space Cavity Width Height Sheathing Framing Solar pelow _15 N=>S Garage Frame -Wood KITCHEN 11 24 8 192.0 ft' 0.23 0.4 0 DOORS # Omt DoorType Space Storms U-Value Ft Width Height In Ft In Area 1 SE=>NW Insulated ENTRY None .39 3 1 6 8 20.6ft- _ / Wall V # Ornt ID Frame WINDOWS Orientation shown Is the entered orientation => changed to Worst Case. Overhang Panes NFRC U-Factor SHGC Imp Area Depth Separation ' IntShade Screening 1 NW=>SE 3 Metal 2 SW=>NE 4 Metal 3 SE=>NW7 Metal 4 NE=>SW 13 Metal 5 NW=>SE14 Metal Low-ESingle Low-ESingle Low-ESingle Low-ESingle Low-ESingle Yes 1.04 0.29 N Yes 1.04 0.29 N Yes 1.04 0.29 N Yes 1.04 0.29 N Yes 1.11 0.27 N 32.9 ft' 1 ft0 in- 6.9 ft' 1 ft 0 in 24.0 ft' 6ft0 in 37.5 ft' 1 ft 0 in 40.0 ft' 8ft0 in 1 ft 5 in Drapes/blinds 1 ft 5 in None 1ft5 in None 1 ft 5 in None 1ft5in Drapeslblinds Exteriors None None None Fxterlor5 GARAGE # FloorArea CeilingArea Exposed Wall Perimeter Avg. Wall Height ExposedWalllnsulation 1 315 ft' 315 ft- 24ft _81t 11 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse ProposedACH(50) .000356 1375.7 75.53 142.04 .1233 7 HEATING SYSTEM # System Type Subtype Speed Efficiency Capacity ,Block Ducts 1 Electric Heat Pump/ Split Single HSPF:8.5 34.8 kBtulhr 1 sys#1 COOLING SYSTEM # SystemType Subtype Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 CentralUnitl Split Single SEER:15 34.8 kBtulhr clin 0.85 1 sys#1 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.97 50gal 60.9gal 120deg None 4/20/20203:04 PM EnergyGauge®USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition(2017) Compliant SAvare Page 4of5 FORM R405-2017 INPUT SUMMARY. CHECKLIST REPORT SOLAR HOT WATER SYSTEM FSEC Collector Storage Cart # CompanyName System Model# Collector Model# Area Volume FEF None None ft2 DUCTS _ / —Supply- Return Air CFM 25 CFM25 HVAC# V # Location R-Value Area Location Area LeakageType Handler TOT OUT ON RLF Heat Cool 1 Attic 6 175 ft2 Attic 65 ft2 DefaultLeakage . Attic (Default) c(Default) c 1 1 TEMPERATURES PmgmmablereTO,hennostat: Y Ceiling Fans: Venting HFeb r00, NMar Apr € Jun D0 [ ]Jul [XJ [ ]Aug D'0 [ ]Sep [ ] LJ [ ],Jan May Jun [)Jul [)Aug I 1 Sep lxl Qc Nov Dec ThermostatSchedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) 80 80 78 78 78 PM 78 78 78 78 78 78 78 Cooling (WEH) PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating(WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 fib 66 Heating(WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 .68 68 68 68 68 68 66 66 MASS Mass Type Area Thickness FumitureFraction Space Default(8lbs/sq.ft. 0 ft2 Oft 0.3 1BEDROOM Default(8lbs/sq.ft. ft2 ft 0.3 WIC Default(8lbs/sq.ft. ft2 ft 0.3 M. BATH Default(816s/sq.ft. ft2 ft 0.3 KITCHEN Default(81bs/sq.ft ft2 It 0.3 BATH Defaull(Blbs/sq.ft. ft2 ft 0.3 BEDROOM Default(8 lbs/sq.ft. ft2 ft 0.3 ENTRY Default(8lbs/sq.ft. ft2 ft 0.3 LAUNDRY Default 81bs/s .ft.. ft2, ft 0.3 GREAT/DINING 4/202020 3:04 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 5 of 5 2017 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: WYNNE THE STERLING IMPACT Builder Name: WYNNE DEVELOPMENT Street: THE: STERLING Permit Office: ST. LUCIE COUNTY ' City, State, Zip: FT. PIERCE, FL, Permit Number: x Owner. Jurisdiction: w Design Location: FL, Fort Pierce = U COMPONENT AIR BARRIER CRITERIA INSULATION INSTALLATION CRITERIA General A continuous air barrier shall be installed in the building envelope. Alr-permeable insulation shall requirements The exterior thermal envelope contains a continuous air barrier. not be used as a sealing material. Breaks or joints in the air barrier shall be sealed. 'Ceilinglattic The air barter in any dropped ceiling/soffit shall be aligned with The insulation in any dropped ceiling/soffit the insulation and any gaps in the air barrier shall be sealed. shall be aligned with the air barrier. Access openings, drop down stairs or knee wall doors to unconditioned attics aces shall be sealed. Walls The junction of the foundation and sill plate shall be sealed. Cavities within comers and headers of frame walls • The Junction of the tap plate and the top of exterior walls shall be shall be Insulated by completely filling the cavity sealed. with a material having a thermal resistance of R-3 Knee walls shall be sealed. per inch minimum. Exterior thermal envelope Insulation for framed . walls shall be installed in substantial contact and continuous alignment with the air barter. Windows, skylights The space between window/doorjambs and framing, and and doors skylights and framing shall be sealed. Rim joists Rim joists shall Include the air barrier. Rim joists shall be insulated. Floors The air barrier shall be installed at any exposed edge of Floor framing cavity insulation shall be installed to (including insulation. maintain permanent contact with the underside of above -garage subffocr decking, or floor framing cavity insulation and cantilevered shall be permitted to be in contact with the top side floors) of sheathing, or continuous Insulation installed on the underside of floor framing and extends from the bottom to the top of all perimeter floor framing members. Crawl space walls Exposed earth in unvented crawl spaces shall be covered with Where provided Instead of floor insulation, insulation a Class I vapor retarder with overlapping joints taped. shall be permanently attached to the crewlspace Shafts, penetrations Duct shafts, utility penetrations, and flue shafts opening to exterior or unconditioned space shall be sealed. Batts in narrow cavities shall be cut to fit, or narrow Narrow cavities cavities shall be ,filled by insulation that on installation readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spa s. Recessed lighting Recessed light fixtures installed in the building thermal envelope Recessed light fixtures installed In the building shall be sealed to the drywall. thermal envelope shall be air light and IC rated. Plumbing and wiring Batt Insulation shall be cut neatly to. fit around wldng and plumbing in exterior walls, or insulation that on installation readily conforms to available space shall extend behind nininn and wirina Shower/tub The air barrier installed at exterior walls adjacent to showers and Exterior walls adjacent to showers and tubs shall on exterior wall tubs shall separate them from the showers and tubs. be insulated. Electrical/phone box oi The air barrier shall be installed behind electrical or communication exterior walls boxes or air -sealed boxes shall be Installed. HVAC register boots HVAC register boots that penetrate building thermal envelope shall be sealed to the sub -floor or drywall. Concealed When required to be sealed, concealed fire sprinklers shall only be sprinklers sealed In a manner that is recommended by the manufacturer. Caulking or other adhesive sealants shall not be used to fill voids a. In addition, Inspection of log walls shall be In accordance with the provisions of ICC-400. 4/20/2020 3:05 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1 2017 EPL DISPLAY CARD ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 99 The lower the Energy Performance Index, the more efficient the home. 1. New home or, addition 1. New (From Plans) 12. Ducts, location & insulation level a) Supply ducts R 6.0 2. Single-family or multiple -family 2. Single-family b) Return ducts FL 6.0 c) AHU location Attic 3. No. of units (ifmultiple-family)3. 1 4. Number of bedrooms 4. 2 13. Cooling system: Capacity 34.8 5. Is this a worst case? (yes/no) 5. Yes a) Split system SEER. b) Single package SEER 15.0 c) Ground/water source SEERICOP 6. Conditioned floor area (sq. ft.) 6. 1474 d) Room unit/PTAC EER e) Other 7. Windows, type and area a) U-factor:(weighted average) 7a. 1.060 b) Solar Heat Gain Coeffiicient(SHGC) 7b. 0.284 14. Heating system: Capacity 34.8 c) Area 7c. 141.3 a) Split system heat pump HSPF 8.5 b) Single package heat pump HSPF 8. Skylights c) Electric resistance COP a) U-factor:(weighted average) 8a. NA d) Gas furnace, natural gas AFUE b) Solar Heat Gain Coefficient (SHGC) 8b. NA e) Gas furnace, LPG AFUE 0 Other 9. Floor type, insulation level: a) Slab -on -grade (R-value) 9a. 0.0 b) Wood, raised (R-value) 9b. 15. Water heating system . c) Concrete, raised (R-value) 9o. - a) Electric resistance EF 0.97 b) Gas fired, natural gas EF 10. Wall type and insulation: c) Gas Fred, LPG EF A. Exterior: d) Solar system with tank EF 1. Wood frame (Insulation R-value) 10A1. e) Dedicated heat pump with tank EF_ 2. Masonry (Insulation R-value) 10A2. 4.1 f) Heat recovery unit HeatRec0/a B. Adjacent: g) Other 1. Wood frame (Insulation R-value) 10B1. 11.0 2. Masonry (Insulation R-value) 10B2. 16. HVAC credits claimed (Performance Method) 11. Ceiling type and insulation level a) Ceiling fans a) Under attic 11a. 30.0 b) Cross ventilation No b) Single assembly 111b. c) Whole house fan No c) Knee walls/skylight walls 11c. 19.0 d) Multizone cooling credit d) Radiant barrier installed 11d. No e) Muitizone heating credit f) Programmable thermostat Yes *Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT I certify that this home has complied with the Florida Building Code, Energy Conservation, through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL display card will be completed based on installed code compliant features. Builder Signature:_ ��� Date: k-`D-CA O^^`` � Address of New Home: THE STERLING S� X y City/FL Zip: FT. PIERCE, FL S 4/20/2020 3:05:01 PM EnergyGaugeO USA 6.0.04 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1