ausuiy,isdsa amallujI
OZ01 9 0 AdW
Gulf Coast Supply and MFG 5v Crimp Metal roofing FL #11651.12
10iant3 24 ge. 5v crimp metal roofing attached to plywood deck using #9 x 1.5"
wood screws with self sealing washer at 12" o.c. max spacing over ASTM D
(type 2) 30 lb felt underlayment installed with min. 4 side laps and G" end
laps fastened with corrosion resistant tin caps and with 1.25' ring shank nails
spaced G o.c. at all laps and two staggered rows 12' o.c. in field. Attach
deck to trusses using attachment detail on this sheet
12" '.
.H.
c thick pica textured O O
stucco on typical concrete
block construction
Finish Columns with coral finished 8"wcocut
bands
5/8 thick cut coral '"
finished stucco bands RIGHT E L E V A T I 0 N
SCALE: 1/4' = I'-O"
Gulf Coast Supply and MFG 5v Crimp Metal roofing FL #11151.12
26 ga. 5v crimp metal roofing attached to plywood deck using #9 x 1.5"
wood screws with self sealing washer at 12' o.c. max spacing over ASTM D
(tgpe 2) 30 lb felt underlayment installed with min. 4' side laps and 6" and
laps fastened LI corrosion resistant tin caps and with 1.25" ring shank nails
spaced G o.c. at all laps and two staggered rows 12" o.c. in field. Attach
deck to trusses using attachment detail on this sheet
12
SLOPE 14
8'-I" T.O_B_
2"
0'-0" = Finished Floor
ELEVA71ON N07ES:
Gulf Coast Supply and MFG 5v Crimp Metal roofing FL #11451.12
24 ga_ 5v crimp metal roofing attached to plywood deck using #9 x 1.5"
wood screws with self sealing washer at 12" o.c. max spacing over ASTM D
(type 2) 30 lb felt underlayment installed with min. 4 side laps and L" end
laps Fastened with corrosion resistant tin caps and with 1.25" ring shank nails
spaced L" o.c. at all lapa and two staggered rows 12" o.c. in field_ Attach
deck to trusses using attachment detail on this sheet
12
Finish Columns With
5/8" thick cut coral
finished stucco bands
12"
Mil
O2 5/8" thick x 8"w cut
coral finished stucco bands
-t t
5/8" thick light textured
stucco on typical concrete
block construction
REAR ELEVATION
- Overhangs at 1'-0" unless otherwise noted on Roof Plan
- Roof pitch at 4:12 unless otherwise noted
- Any changes to this plan shall be submitted to the architect
for approval in writing prior to starting construction.
- Return ALL Stucco Bands into Window or Door.
12
4 SLOPE
8'-1" T
0. 5/8" thick x 8% cut C
coral finished stucco bands 3
5/8" thick light textu' d
stucco on typical concr
block construction
Finished Floor --------------------------
LEFT ELEVATION
r
Product Approval Submittal Affidavit
Opening Schedule Swing Doors, Overhand Doors, Sliding Doors,
windows h Skylights
Opening
Type
NOAfFL
NUMBER
Product
Model #
Manufacturer
Glass
Attachment method
EzpTESn'ation
Da
Design Pressure
of Approved Tests
1,2r3
t4
FL# 239.9
Single Hun
9 9
SH-1100A
la t
PGT
5/IG"
I/4' m. tapcons w/ inn. 1 3/8" pene.ration to be
spaced per product approval. Contracar shall adhere to
min. edge dstances specified in Product approval
L5.O/-80.0 PS
C"
A
16-0330.02
Overhead
Garage Door
_I
Model 824/811
9'-4" max. width
IIII max height
DAB
i ss se"volt. Dais x c, adu W� s..v. mxRiiet opt.
eh I. �rt 1 odes estann. i v w t, trek
: fiis iuit �e de screws m a"..a4.t
is. d ts' ass axean - oe t, strictly wism e,pr,a�t r'°'s
1/IL' uaaMr ew islet aMIG.
10-9-21
+ 50.0/-60.0 oaf
B
FL# IGL14.1
Fiberglass
D51=9h Pro
Jeld—Wen
Elco 1/4' dia. tapcon with min 1.25" embelment at 3' max
iron corners and n.5' o.c. max. thereafter in heed and iambs
+ 50.0 PSF
C
FL# 251.4
Sliding Glass
Door
Series ll0
PGT
I" nom
Type "G5A"
lspaced peer• or am hovel- contracto isshhall adhere to
min. 2 I/2 edge distances specified in Produce approval
± LO.O PSF
Product
NOI
NUMBER
Model #
Manufacturer
Attachment Method
Expiration
Date
Design Pressure
of Approved Tests
Mullions
FLU 261.1
1" x 2 3/4' x .315"
PGT
Inatell per fastener type and spacings shown in Table IA and IB
in product approval on sheet 5 of 22.
+ 58.0 PSF
Roof
FL# IIG51.12
5V Crimp
Metal Roofing
Gulf Coast Supply
and manufacturing
2L 5v crimp metal roofing attached to plgwood deck wing a9 x 1.5"
ft °Z 30wilbhPelt unwdera wen[ metalled nth minx spacing over and `M°D
ilp w
laps fastened with corromon resistant tin cape and with 1.25. ring shank nails
spaced 6' c.c. at all laps and two staggered rows 12" o.c. in field. Attach
deck to trusses using attachment dotal on root plan
— 108.6 PSF
Siding
Stucco on Block
Soffit
FL# 12198.3
Model T4 12" vented
Vinyl Soffit
Kaycan
Install using 2" x 2" battens at L' o.c. screwed to soffit training using
#81 x 33' wood screws aona t each truesa shank ' wtLall soffit to battens using
+55.0/-35.0 PSF
Hurricane
Panels
I have reviewed the above and approved it by my seal below. ( Architect or Engineer of Record
SCALE: 1/4" = 1'-0'
5/8" thick x 8"W cut --
coral finished stucco bands
2" x 4" top plate 1/2' drywall ceiling on truss bottom cord
1/2" drywall on
2" x 4" studs at 14" O.C.
base -board � 11 11 / 2" x 4" P.T, bottom plate
\ 4" concrete slab with fibermesh OR
G xL #10/10 WWII on G and Visqueen over
clean compacted termite treated fill
Interior Non -Bearing Partition
nLS
12
4 1 SLOPE
SCALE: 1/4' = 1'-0'
Gulf Coast Supply and MFG 5v Crimp Metal roofing FL #11(.51.12
26 ga. 5v crimp metal roofing attached to plywood deck using #9 x 1.5"
wood screws with self sealing washer at 12" o.c. max spacing over ASTM D
1112) 30 lb felt underlayment Installed with min. 4' side laps and 6" end
laps fastened with corrosion resistant tin caps and with 1.25" ring shank nails
spaced L" o.c. at all laps and two staggered rows 12" o.c. in field. Attach
deck to trusses using attachment detail on this sheet
1/8" Thick cut coral stucco over paper
backed wire lath nailed to substrate through
one lager of 15 Ib felt using I nails. Substrate
to be 19/32" CDX Plgwood nailed at 6" o.c.
in field and edges with IOd ring shank galvanized
nails into truss webbing.
5/8 tic Ight texture ish Columns with
we"stucco on typical concrete 5/8" thick cut coral
block construction finished stucco bands
FRONT ELEVATION
SCALE: 1/4" = 1'-0"
ALL CONTRACTOR WARRANTIES BEGIN WHEN THE CLOSING
OCCURS BETWEEN THE BUYER AND WYNNE BUILDING CORP.
AND WILL CONTINUE FOR ONE YEAR FROM THAT DATE
PERMITTING INFORMATION (FORM 100)
Florida Building Code Residential: Lth Edition and ASCE 1-10 for Wind Loading
Building Design is; Enclosed Risk Categorgg: II Wind Velocity: IL5 mph ultimate
Mean Roof Height: Roof Pitch: +12
Internal Pressure Coefficient: 10_I8
Subjectabdity to damage from: Weathering: Negligible Termites: Very Heavy
Width of Roof End Zone: 3'-4" Wind Speed: I45 mph ultimate
Wind Exposure Classification: C L21 x O.L = 012L
Adjustment factor for Exposure Height: ASD design
Load Combination: ASCE 1-10 Section 2.4 DL+LL; DL+O.LWL; 0.LDL+O.6WL
Components t Cladding Wind Pressure (NET) Roof Zone. I. +20.6/-32.4 pet
Roof Zone: 2. +20.L/-51.0 pet
Roof Zone: 3. +20.6/-84.0 oaf
Components t Cladding Wall End Zone Width: 3'-4"
Components t Cladding Wind Pressure (NET) Wall Zone: 4. +35.8/-38.1 psf
Wall Zone: 5. +35.8/-41.8 pet
Components t Cladding Wind Pressure (NET) on Garage Door: +32.0/-40.3 pet
Shear Walla Considered for Structure? Yes
Continuous Load Path Provided? es
Are Components an Cladding Details Provided? Yea
Minimum Sal Bearing Pressure:2.500 psi, Presumptive: X By Test: psi
SEE PRODUCT APPROVAL FOR IMPACT PROTECTION FOR OPENING
ROOF LIVE LOAD: 31 pet ROOF DEAD LOAD: 10 psf
FLOOR LIVE LOAD: --'%— pet FLOOR DEAD LOAD: 10 oaf
JOB ADDRESS: n ISL,t,p, rr�ip
19.5S0;rr
0 = Roof Zone I
Walls Zone 4
® = Roof Zone 2
Walls Zone 5
END ZONE
= Corner Zones
Roof Zone 3
36'-O"
FLOOR FLAN
1<_� CRASH POST DETAIL
TYPICAL NOTES: SCALE 1/4" = 1'-0" N.T.S.
steel
p ste
I. Contractor to verify ALL notes and dimensions prior to high by 4" diameter
el crash post. Floor
proceeding with work. Flange with 4 - 3/8"
2. Contractor to STRICTLY enforce ALL OSHA Re uirements. slab la ansion bolts into
q (3/8"t 50 ks1 steel plate)
3. ALL Lumber to be used as Beam, Rafters, etc... to have
a minimum 1,400 P.S.I. fiber stress.
4 No dlssimllar metals to touch
5.
ALL Concrete used for slabs shall be min. 2,500 PSI concrete.
o
ALL Concrete used for vertical filled cells, cont. tie beams etc.. to
M
shall be 3,000 P.S.I. concrete and/or -4,000 P.S.I. grout mix
6.
Drywall at ceilings shall be leveled and attached to bottom chord
LO6
of trusses with screws per FBC R�102.3.5.
1.
ALL wood in contact with concrete shall be pressure treated.
8.
ALL wall dimensions are nominal and not finished wall or stud dimensions.
9.
ALL plumbing fixtures to be low flow.
10.
Contractor to Provide Drain at water heater in accordance
with the current edition of the Florida Plumbing Code.
11.
Contractor to Provide a 2'-8" wide door at one bathroom for
handicap accessibility requirements.
v211
12.
Lowest finished floor to be set by Governing Building Department
13.
surveyor to set in field.
Separation between residence and garage shall be per FBC R302.6
14.
Door between garage and residence shall be 1-3/4"t 20 min. rated door
w.H. = Water Heater
15.
Wall and Ceiling shall have a flame -spread classification of not greater than 200 pper
FBC R302.9.1
16.
Wall and ceiling finishes shall have a smoke -developed index of not greater than 450
per FBC R302.9.2
11.
All exposed attic insulation materials installed on attic floors shall have a critical radiant I" x L" P.T. Buck nailed to
flux not less than 0.12 watt per square centimeter. Exposed foam plastic insulation
block with case hardened nails
materials exposed on the underside of the roof deck or on the attic walls shall comply
prior to door attachmen
18.
with F.B.C. R31L - see permit info box of code edition
Gy�(psum board material shall conform to ASTM C36, C19, C415, C514, C630, C931
Ao, C1002, C1041,C1117, C11-18, C1218, C1395, or C1396 and shall be installed
nccordinn to the following: (FBC R-i02.3.5)
::, ._ ,:
Drywall
Thickness
Location
Orientation
Framing
Member
Max. spacing
of fasteners
Nail sizing options for
installation of drywall into
Spacing
Maximum
wood framin members
x min. t icknesa
Ceiling
Perpendicular
24"
13ga 1 3/8" lloong with 19/64" head
TNailsScrews2"
0.098" diameter x 1 1/4" long
annular -ringed or 5d cooler nail
OR
0.080" dia. x 1 5/8" long with
15/64" head
Walls
Either
16"
Direction
OR
Ggpsum board nail 0.086" dia.
x 15/8" with 9/32" head.
Ceiling
Perpendicular
24"
1"
12"
13ga 15/8 ,bong with 19/44" head
0.098" diameter x 1 3/8" long
annular -ringed or 4d cooler nail
e
0.092" dia �R 1 1/8' long with
Walls
Either
16"
g"
16"
Direction
I/4" head
OR
Ggpsum board nail 0.0915" dia.
x 1 I/8" with 19/L4" head.
Install SGD thru buck into
block with 3/14" tap -con with
1 1/2" penetration at 6" o.c. max.
from each corner and 20." o.c. max
thereafter at head per product approval
Use 3/I6" tap -con with
1 1/2" penetration at L" o.c. max.
from each corner and 20" o.c. max
thereafter at sill per product apprc
19, ALL ceramic the surfaces installed shall conform to ASTM A108.1 thru A108.6,
A108.1, A118.1, A118.3, A136.1 and A131.1
20. Cement, fiber -cement or glass mat gypsum backers in accordance with ASTM
C1288, C1325, OR CII-18 and installed I.A.W. manufacturers recommendations shall
be used as backer for the wall tile in tub areas and wall panels in shower areas.
21. insulation including facings such as retarders or vapor permeable mem5ers installed
within floor -ceiling assemblies, roof -ceiling assemblies, wall, crawl spaces and attics
shall have a flame spread index not to exceed 25 with an accompanying smoke
developed index not to exceed 450 when tested in accordance with ASTM E 84.
insulation shall comply with F.B.C. iR316.
Gulf Coast Supply and MFG 5v Crimp Metal roofing FL #11651.12
2G ga. 5v crimp metal roofing attached to plywood deck using #9 x 1.5"
wood screws with self sealing washer at 12" o.c. max spacing over ASTM D
(type 2) 30 lb felt underlagment installed with min. 4 side laps and 6" end
laps fastened with corrosion resistant tin caps and with 1.25" ring shank nails
?aced 6" o.c. at all laps and two staggered rows 12" o.c. in field. Attach
dpeck to trusses using attachment detail on this sheet
Simpson HETA 20 or equal
hurricane anchor at each trues
with (10) IOd x 11/2" nadc
( 24" o.o.) $upport°ng Max.
18101bs. uplift
Grade
T
Aluminum Drip -
Edge il Fascia
2" x 6"
Kagcan full o vent ving
ueng 1/8' dia shank x I
roofing nails with 3/8"
product approval - see
5/8" thick light textured
stucco on typical concrete
block construction
#5 bar vert. w/
30" overlap -
at each filled cell
12
PRE-ENGINEERED TRUSSES
4I at 24"o.c. TYPICAL
(shop drawings by manufacturer)
"\R-30 blown fiberglass
in bottom chord or trusses
I/2" drywall with smooth finish
Two rows of beam block filled with concrete
and (U #5 bar cont. in each row. Substitute
ad precast lintel filled with concrete and (U #5
bar cant. For bottom row over openings
#I 1/2" drywall over I" x furringg
strips at 16" o.c. with R4.1 Frfod
insulation on typical 8" Block walls
All drywall to be installed per FBC R'102.3.1
and shall meet all pertaining ASTM codes.
ao Mortar to be Type "M" only proportioned per FBC R601.1
and Mortar Jonts shall comply with FBC R401.2.1.
Provide Dur-O-Rock at all wet areas (ex. showers, tubs etc...)
Fill cell with concrete and
(l) #5 bar vert. (typical).
-Max. spacing shall not exceed
48" unless otherwise noted
ace Foundation plan notes For
spacing at openings
4" concrete slab with f°bermesh OR
6 xil#10/10 WWM on L mil V°squeen over
clean compacted termite treated fill
I I I I -I I I IE1111 III I
- -'"-� 111E1111-1 I II I 11111�''-
14" x 14" Concrete footing
%�
14" with (2) #5 bars cost. and #5
F I C A L SECTION
transverse bars at 48" o.c.
Scale : I/2" = I'-O"
Sliding
I
AREA CALCULATIONS
Living A/C = 1,414 sq. ft.
Front Porch = 153 sq. ft,
Rear Porch = 114 sq. ft.
Garage = 321 sq. ft.
Total Under Roof= 2.124 Sq. ft.
Total Cubic Ft = 11,192
1-1 2' VTR
o J�� I
I 12„
O 2i'A„ � I 12,E 1 BATHER
i i I LAV-1
ih I �L,AV-I �,�
Masonry Beam
IN
12=1
fixed door
sliding door
1 1/2„
Sill
Door Detail
At Masonry Wall
NTS
2" LAUNDRY 3" 2" '
2" 1 2' AAV 4L2' VTR
3„ BT-1 3" 6-1 1
2, KTICHEN 2"
2„ LAv-11
3" � 2„
WC-1 BATH #2
PLUMBING RISER 3
I" x 6" P.T. Buck nailed to
block with case hardened nails
prior to door attachment
Masonry Wall
yp°cal Flooring
Install SGD thru buck into
block with 3/14" tap -con with
1 1/2" penetration at V o.c. max.
from each corner and 20." o.c. max
thereafter at Jambs per product approval larnk
Window
Schedule
Mark
Size
Rough Open.
Window Descrl tion
PRESSURE ZONE
I.
4'-5%"x 5'-3%"
54%a"x 63%;'
Single Hung
ZONE 4
2.
6'-2Ys"x 5'-3'/e"
15" x 43 %;'
Single Hung
ZONE 4
3.
2'-2" x 3'-2 1/2"
2'Ii2"x 385s"
Single Hung
ZONE 4
4.
4'-5%"x 4'-2%a"
54318"x 54y8"
Single Hung
ZONE 4
ALL
Windows to be aluminum
windows wl tint
and mullions per
elevations.
ALL
windows to Withstand
pressures in permit info box on
sheet I
ALL
windows in bathrooms to
be tempered
All
rough opening
dimensions
to be verified by contractor
with
manufacturer s specs prior to construction
Door Schedule
Mark
Size
Rough Opening
Door Description
PRESSURE ZONE
A
9'-0" X 1'-0"
108" x 84"
Overhead Garage Door
ZONE 4
B
3'-0" X V-8"
41 i/4"x 83%"
Fiberglass Panel - Inswing
ZONE 4
C
4'-O" X 4'-8"
14" x 81 %2" 077 .t:-
Sliding Glass Door
ZONE 4
D
2'-0" X c-8"
Solid Core - Wood
- L-Panel -Bi-Fold
Finished 24" x 81 °/2"
H
X-L" X V-8"
Solid Core - Wood
- L-Panel
F
5'-0" X 6'-8"
Solid Core - Wood
- 6-Panel - Bi-Fold
G
2'-8" x C-8" x 1 %"
Solid Core Wood, Steel, or Masonite Door
H
2'-8" X V-8"
Solid Core - Wood
- 4-Panel
J
X-6" X V-8"
Solid Core - Wood
- 4-Panel - Bi-Fold
K
2'-8" X V-8"
Solid Core - Wood
- 4-Panel - Bi-Fold
L
1'-L" X 4'-8"
BI-FOLD
ALL Exterior doors to withstand pressures stated in permit info
box on sheet 41
GARAGE DOOR SPECIFIED IN PRODUCT APPROVAL FORM AND SHALL
WITHSTAND THE PRESSURES STATED IN PERMIT INFO BOX ON SHEET 41
All rough opening dimensions to be verified by contractor
, with manufacturer s specs prior to construction
To septic
O
I
LnM
Install windows thru buck into
block with 3/10 tap -con with
1 1/2" penetration at L" o.c. max.
from each corner and 20." o.c. max
thereafter at Iambs and 20" o.c. max.
Exterior face at head and sill per product approval
of wall -\ / \ Buck to be I" x 4" PT
Detail at Windows
I"x4" P.T. Buck nailed to
block with case hardened nails
prior to window attachment
NTS
Attach buck to block wall with
1/4" dia. Elco cone screws with min.
1 1/4" penetration at 12" o.c. max
and 4" max from each corner thru
Exterior face 2" x 4" PT Buck
of wall
ariea
INSTALL VULKEM BLOCK SEALANT #8 Wood screws thru Jamb into buck
ON ALL JAMB, HEADER. AND at each hinge and 15" o.c. max and
SILL BLOCK PRIOR TO BUCK Detail at Door prior to door attachment
INSTALLATION
NTS
m
STRUCTURAL
NOTES:
I.
ALL FOOTING ARE DESIGNED FOR A MINIMUM OF 2,500 PSF SOIL
S.
SLOPE ALL PORCH SLABS, COVERED WALK, ETC. AWAY
BEARING CAPACITY. IF ANY SUB -SOIL, MUCK OR NON -UNIFORM
FROM HOUSE TO DRAINS (IF PROVIDED) PER PLANS
CONDITIONS EXIST, REPORT TO ARCHITECT AND OBTAIN
PROPER ENGINEERING DATA FOR DESIGN.
2•
ALL SLABS AND FOOTINGS TO BE A MINIMUM 2,500 PSI AT 28 DAYS
9.
DESIGN LOADS ARE AS FOLLOWS:
ALL COLUMNS, FILLED CELLS, AND BEAMS SHALL BE MIN. 3000 PSI
ROOF fDL+LL) = 41 PSF
BE 3000 PSI OR 4,000 PSI GROUT MIX AT 28 DAYS
WiND VELOCITY = PER PERMIT INFO BOX ON SHEET 41
EXPOSURE ="C"
3.
POISON SOIL AND COVER W/ 6 MIL. VISQUEEN WITHIN 24 HOURS. NO
SOIL POISONING TO BE ACCOMPLISHED OUTSIDE OF FOUNDATION.
1p
ALL REINFORCING STEEL SHALL BE GRADE 40, MEETING ASTM A-I6, 6.
4
GROUND FLOOR SLAB TO BE A MINIMUM 4" THICK W/ 6X6 10/10
A-35 SPECIFICATIONS. ALL ANCHOR TO BE A - 30-1 STEEL.
WELDED WIRE MESH REINFORCING ON 6 MIL. POLYETHYLENE VAPOR
BARRIER ON TERMITE TREATED, CLEAN MACHINE COMPACTED FILL
11
ALL DOWELS, SLEEVES, CONDUITS, INSERTS, BLOCKOUTS, ANCHOR
(MINIMUM 95% DENSITY). LAP POLYETHYLENE 12" MINIMUM. FIBERMESH
BOLTS AND FRAMES SHALL BE IN PLACE PRIOR TO POURING CONCRETE.
MIX MAY BE SUBSTITUTED FOR WELDED WIRE MESH.
FOR OPENINGS AND SPECIAL FEATURES OMITTED ON THESE PLANS,
SEE ARCHITECTURAL OR MECHANICAL PLANS WHERE APPLICABLE.
5
LOT TO BE CLEARED OF ALL SMALL PLANT GROWTH AND DEBRIS
BEFORE FILL IS BROUGHT IN. FILL MATERIAL SHALL CONSIST OF
CLEAN GRANULAR SAND CONTAINING LESS THAN 10% MATERIAL
12•
MINIMUM CONCRETE PROTECTION FOR REINFORCING BARS:
PASSING THE US STANDARD NO. 200 MESH SIEVE. PLACE
FOOTING: 3"
STRUCTURAL FILL IN LOOSE LAYERS OF 12" IN THICKNESS AND
BEAMS: 1-1/2"
COMPACT EACH LIFT TO AT LEAST 95% OF ITS MODIFIED DRY
PROCTOR VALUE.
13.
LAP ALL REINFORCING STEEL A MINIMUM OF 48 BAR DIAMETERS.
6•
GENERAL CONTRACTOR TO VERIFY ALL EXISTING CONDITIONS AND
14.
USE STRUCTURAL GRADE WOOD WITH A MINIMUM Fb OF 1400 PSI
DIMENSIONS. BRING ANY DISCREPANCIES OR OMISSIONS TO THE
ATTENTION OF THE ARCHITECT.
IS-
ALL STANDARD LUMBER SHALL BE SYP WITH A MINIMUM Fib OF 1000
PSI OF NO.2 SOUTHERN PINE, UNLESS NOTED OTHERWISE.
7
GARAGE FLOORS TO BE SMOOTH TROWEL FINISH (SLOPPED PER
FOUNDATION PLAN). PROVIDE 1-1/2" RECESS FOR OVERHEAD DOOR
16.
ALL LUMBER IN CONTACT WITH ANY CONCRETE OR MASONRY SHALL BE
PRESSURE TREATED. FASTENERS TO HAVE MIN. G185 RATING.
FOUNDATiON F L/4N
I. Any changes to plans must be submitted to the architect
for approval before proceeding with construction.
2. Contractor shall be responsible for verification Of all
notation and dimensions before starting construction.
3. Soil conditions assumed to be 2500 psf. Should any other conditions be
encountered, the architect shall be notified in writing for revision
4. Verify all recess thickness at showers, tile, etc....
8. Contractor to provide filled cell with concrete and 1 45 bar vert. at 48"
o.c. max. Provide (1) filled cell on each side of openings up to 5'—I1" wide.
and Provide (3) filled cells on each side of openings from 10'-0" and up
Contractor to see plans for any other condition used. Foundation walls
shall have filled cells at 24" o.c. unless otherwise noted (see section)
6. Contractor to provide for Form Board Survey — Form Board Survey
to be provided to Truss Company prior to truss construction
1. Contractor to provide for soil test prior to construction and provide
a copy of soil test to architect for review prior to construction
8. ALL Reinforcing steel shall be grade 60, meeting ASTM A—I6 and
A-35 specifications. ALL Anchors to be A-301 steel.
9. Provide a minimum of 3" concrete protection at footings and
1-1/2" concrete protection at beams for ALL reinforcing bars.
35 bar vertoverlap
w/ Fill call with concrete and
30" overlap „
111 (I) #5 bar vert. (typicaU- Thicken edge to 8 x8
SCALE: 1/4" = 1'-0"
Termite Protection for New
Construction.
Soil treatment used for subterranean termite prevention
inside the foundation perimeter shall be done after all
excavation, backfilling and compaction is complete.
If soil area is disturbed after initial chemical soil treatment
area shall be re -treated with a chemical soil treatment
including spaces boxed or framed.
Treatment must be in accordance with the rules and laws
established bg the Florida Department of Agriculture and
consumer services.
Protective sleeves around metallic piping penetrating
concrete slab on grade floors shall not be of cellulose
containing materials and shall receive application of
termicide in annular space between sleeve and pipe.
at each filled c Max. spacing shall not exceed with concrete and 4" concrete slab with fibermesh OR
Wood 48" unless otherwise noted one 45 bar continuous VxV #10/10 WWM on 10 mil Visqueen over
Base see foundation plan notes for clean compacted termite treated fill
spacing at openings
4" concrete slab with fibermesh OR GRADE
6"x6" #10/10 WWM on 6 and Visqueen over
clean compacted termite treated fill a'
Grade
III IIII
ITIIII 1111- 114"w x 18"d Concrete Footing
11 1 with (2) #5 bars Cont. and #5
transverse bars at 48" o.c.
TYPICAL FOOTING DETAIL
J SCALE 1/2" = I'-0"
4" concrete slab with fibermesh OR
6"x(V #10/10 WWM on 10 mil Visqueen over
clean compacted termite treated fill
#5 bar Cont.
Step per
v...., foundation plan
) #5 bars coat. bottom steel
DETAIL AT GARAGE STEPDOWN
SCALE 1/2" = I'-
12" x 12" concrete column
block filled with concrete
and (2) #1 bars vert. tied
into lintels above
Top of Tooter
IL" below finished floor
_ 30"x30"xl6" concrete
i column footing with !4)
IIII=III 49 bars each way
S
3 0 "
SCALE 1/2" = 1'-0"
PORCH SLAB EDGE DETAIL
95 bar coot. in curb
Curb height
Verify based on
foundation plan
Grade
Wood
Base
77..:
Contractor to provide
proper foundation cfiairs
for proper steel installation
30" min.
SCALE 1/2" = 1'-0" I_ -I
#5 bar vert- w/
-30" overlap Corner Steel Lap
at each filled cell
nts
Fill cell with concrete and
(1) #5 bar vert. (typical). Filled Cell Masonry Column With One
-Max. spFrom Footing shall not exceed #5 FFTo Tie Beam
48" unless otherwise noted g
see foundation plan notes for Conc. Fill To Be 3000 PSI
spacing at openings See Floor Plan For Location
4" concrete slab with fibermesh OR
Vx6" #10/10 WWM on 6 mil Visqueen over
/ clean compacted termite treated fill ;;. '=%•
I-
14% x 18"d Concrete footing
with (2) #5 bars cont. and #5
transverse bars at 48" o.c.
GARAGE CURB DETAIL
SCALE 1/2" = 1'-0"
2" x 6" PT wood secured with
1/2"dia. x 6" expansion anchors
with 2" sq, washer at IS" o.c. overhead door track secured to wood
iamb per manufacturer's product approval
Garage Door Jamb Detail
GARAGE DOOR TO WITHSTAND PRESSURES STATED NTS
IN PERMIT INFO BOX ON SHEET #I. SEE PRODUCT
Single Filled Cell Column
NTS
Filled Cell Masonry Column With One
45 From Footing To Beam Each.
Conc. Fill To Be 3000 PSI
See Floor Plan For Location
Double Filled Cell Column
NTS
14'-O"
36'-O"
10'-O"
121.' 10'-0"
_I_I_i_00— OO — — — — -- °° I — — — — — -I
I I Rear Patio/Slab t -
to be poured separatenL Q
from the house slab. p �I
Thicken footing to 24 m CC<1
FI 24"w x 14"d x 24"L cn -
under filed cellar J �n
I under grader bearing. -
n I Eml ICDI°O ° O I I F I lisI
L— — — — — — — — — — — — — — — — — — — — — ,I
CD I Rear Patio/Slah to
be flush with bottom of
Um I sliding door recess. FI
v ac, c Slope 1/2"
r LLN I I F
o I
I;
I II
I
1 FI
o,
I
H B I Vanity to be
I-d 34 Y2"high 4" concrete slab with fibermesh OR
O C 6 x6 #10/10 WWM on 6 mil Visqueen over
clean compacted termite treated fill
I � I
FI I
o� I
I / I
-� I
C°O I I I
I FI I;
o I�I I
O
I
'V-
I
FI °
OID g °
I �
F F51
eniA r5 0
1 I
A/c ° F— — --- ts
#I II no I rl
4"Pdiedt w% Concrete 0
F5 &L I I p l I
IDIQI I
M o o
I FI I
I M a iu wQJ
I I I
E a ro I I a FI I
o I o —r
V E E
C4LU
00 iL
3 a --�---
-
0UiiiiiIL "
0
o �
bD
H.B.
I Fso I o
° I up c I O
o
1
I ,a
a
L— PS Recess for — — —— J 0 u F4 r 1 F r
ll ri inh Garage Door nr 00 — —F.——— — — — — ——
3'-5"
Extend curb steel into footing #5 bar vert in filled cell
to end of "Z" bar -at curb transition
#5 bar cont in T
of concrete curb
iPr
1 in
F 24" T I ui
-
�-----------------------
in 1 24
Lri _
45 "Z" bar at each 12" Cont. bottom steel
cont steel bar. see foundation plan
STEPPED FOOTING DETAIL
SCALE 1/2" = 1'-0"
a `e g Q —
6.5" Stop F
12" x 12" concrete column block fille
3'-5" with concrete and (2) #1 bars vert.
into lintels above
FOOTING
SCHEDULE
Mark
Size
Description
I
14"W
x 18"D
MONOLITHIC FOOTING
WITH 2 #5 BARS CONTINUOUS
F
12"W
X 12"D
MONOLITHIC FOOTING
WITH (2) #5 BARS CONTINUOUS
F
30"
x 30" x IVE)
COLUMN FOOTING WITH (4) #5 BARS EACH WAY
F�
8"W
x 8"D
ITHICKEN SLAB EDGE
WITH I #5 BAR CONTINUOUS
l�J
14"W
With
x 18"D
Curb at Garage
MONOLITHIC FOOTING
WITH 2 #5 BARS CONTINUOUS - CURB 9 0'-0"
ROOF SHEETING
ATTACHMENT DETAIL
i.
rnnimum ixoii 7ize -
ou ring arlarik 1111 . e... P tv
2.
Minimum Screw Size
= 48 x
2"
3.
Minimum Sheathing Thickness
19/32" COX Plgwood
4.
Use nails or screws
based on
pressure for roof stated
in permit info box
on these
plans
for zone 3
Keg
Area
Edge
Field
Fastener
Max.
Pressure
Zone 1
ri
6
6it
8d ring shank
45 psf
Zone 2
ii
6"
Sd ring shank
% psf
3
"
.4"
8d ring shank
84 psf
IZone
** Zone 3a
1 6"
6"
#$ wood screw
112.5 psf
** Use nails or screws based on pressure for roof stated
in permit info box on these plans for zone 3
Verify with Plan >I
Column to :Intel
12"x 12"
lumn Block
Rebar
Provide #5 bars with min. 48 bar
diameters overlap Into beam. Tie
filled cell steel into continuous
beam block steel
Provide Cast -Crete
SUB-OB/OT precast
lintel set in mortar-.
Min. 8" Bearing
N
Provide U5 bar set in pre -cast
lintel Into beam where length of
the opening calla for It.
f
4..
I, r Provide PT Buck
attached
per ,Iamb
details into Pilled cal
4' Pre -cast
Sill
l y ,77
r.4 .'I
i} i
—Poured Filled Cell
Provide 45 bars with min. 48 bar
diameters overlap in filled cell. Tie
Pilled cell steel into continuous
Pooter steel.
SINGLE PLY REAR GIRDER TRUSS
Nail 2" x 4" bloclil to Vertleg of
truss with IOd x 1.5 nails at 4" o.c.
Install Simpson MGT into wall usin
5/8' dra. threaded rod sat min. &
into wet beam and (22) 10d nails into truss
R-II batts
Min- °— verb TRUSS BLOCKiNG DETAIL
AT GiRDER STRAPPING.:
Attachment AT CENTER BEARING POINT
NTS
1/8" thick light textured stucco installed per
ASTM C 924 over ASTM D type 2 paper backed
wire lath nailed to substrate through one layer of
ASTM D Tgpe 2 felt paper using 8d nails. Substrate
to be 19/32" CDX Plywood nailed at 6" o.c. in field
and edges with IOd ring shank nails into studs.
Gulf Coast Supply and MFG 5v Crimp Metal roofing FL 411451.12
24
ga. 5v crimp metal roofing attached to plywood deck using #9 x 1.5"
wood screws with self sealing washer at 12" o.c. max spacing over ASTM D
(type 2) 30 lb felt underlayment installed with min. 4' side laps and 6" end
laps fastened with corrosion resistant tin caps and with 1.26" ring shank nails
spaced ("o.c. at all lapa and two staggered rows 12 o.c. in field. Attach
deck to trusses using attachment detail on this sheet
LINTEL SCHEDULE
Mark
Window
or 0
Unit
Width
Lintel
Size
Cast -Crete
Specification
Rays of
"H" Block
Above
" "
Bottom
steel
Size
Top
Steel
S1ZQ
Max
Gravity
Load
IPLF)
Max.
Uplift
Load
(PLF)
may-
Lateral
Load
(PLF)
L22
2'-2"
V-V
8F8-OB/IT
1
#5
3069
1519
1024
L31
T-6"
4'-0"
8P8-OBAT
1
#5
2561
1363
11.3
L45
4'-5"
5'-10"
811118-OBAT
1
85
1105
909
331
L50
5'-0"
L'-0
811118-OBAT
I
#6
1238
835
121
L60
1.'-9.
1'-6'
81118-013/IT
1
#5
1011
121
534
L80
8'-0"
9'-4"
SFa-I13/2T
I
#5
2
#5
152
591
512
L90
I 9'-D"
10'-V
BPS-IB/2T
I
#5
1 2
#5
643
530
401
L9oB
al
IO'-L"
BFI6-I13/2T
ONE
I
#5
1 2
35
1533
1183
401
LIO0
10'-0'
11'-4"
SF8-8/2T
I
95
1 2
85
562
444
452
LIOOB
10'-0'
ll'-4"
8111I6-0/2T
ONE
I
#5
1 2
#5
1366
1028
1 452
L120
12'-0'
1 13'-4"
8P8-IB/2T
I
#5
1 2
1 #5
1 411
428
1 324
L120B
IT-O"
13'-4"
81111I6-0/2T
ONE
I
#5
2
#6
1016
110
324
L140
14'-0'
15'-4"
SPIL-IB/2T
ONE
I
#5
2
#5
1250
L09
259
L160
IL'-O'
11'-4"
eF8-IB/2T
1
#5
2
#5
300
192
194
L1605
IL'-O"
111-4"
8PIL-IB/2T
ONE
1
#5
2
#5
950
500
194
- ALL LINTELS SHALL BE MADE BY CAST-CRETE.
- LINTELS SHALL BE FILLED SOLID WITH 3000 PSI CONCRETE
- REFER TO CAST-CRETE CATALOG FOR ALL INFORMATION REGARDING
LINTEL CONSTRUCTION, HANDLING INFORMATION, AND SAFE LOAD REQ.
REQUIREMENTS
- LINTELS OVER W-Off LONG ARE TO BE PRESTRESSED.
12
Simpson HETA 20 or equal "f
hurricane anchor at each truss
with (10) IOd x 1 1/2' nails
24" o.cJ supporting Max.
18101be. uplift
Aluminum Drip
Edge t Fascia
Flash and Counter
flash
Nail ledger to
gable end truss
with (2) IOd rls
at each web
Aluminum Drip \ /
Edge t Fascia 5/8' thick stucco on 3/8' hi -rib lath
attached to horizontal and vertical wood
12" framing with nails or staples to provide
no less than 1-3/4" penetration into
2" x 6" Sub-Fasei horizontal wood framing and 3/4' penetration
into vertical wood framing members
Kaycan full o vent vongl soffit installed
using 1/8' die shank x 15' long gals.
roofing nails with 3/8' dia. head per
product approval - sae chart sheet #1
12" x 12' concrete column
block filled with concrete
and (2) #1 bars vert. tie
into lintels above
thicken edge to 8"xa"
wrth concrete and
one #5 bar continuous
BEYOND
Top of footer
IL" below Finished floor
ta
;IIIIIIII
=IIIII�I�—I�I�
-IIII-IIII,
Brace Gable and
with 2" x 4" SYP 42
aft back nailed to bottom
of top chords using (2) IOd
nails at each truss
RE -ENGINEERED WOOD TRUSSES
w 24"o.c. TYPICAL
( shop drawings by manufacturer )
to
a
L
x
10
r
OU
rn
�w
° a
a
a
W
__C
N
u
O I
ra
V
q O
ms,
E10
°D
O
�UCV
Q
w
En
Brace Gable end
with 2" x 4" SYP #2 min.
aft back nailed to bottom -
of top chords using (2) IOd
nails at each truss
R-30 blown fiberglass N Q
yin bottom chord of trusses p
-I/2° drywall with smooth Plnleh ro o
W
Two rows of beam block filled with concrete
.and (1) #5 bar cant- in each row. Substitute
precast lintel Filled with concrete and (1) #5
bar cont. for bottom row over openings cn
1/2" dryywall over I" x furring
strips at 16"
o.c. with R4.1 fi-foil
-insulation on typical 8" Block walls
5/8" thick light textured
stucco on typical concrete
block construction
Varies - see plan
#5 bar vert. w/
30" overlap
at each filled cell
Rear Patio/Slab to
be flush with bottom of
sliding door recess.
Step per foundation plan
a Slope per foundation plan
IIIIIIII—IIII IIII—
,'�. ".. 1=IIII=IIII=IIII11
as n
field
and
C el
Poured Concrete or \
concrete block wall
Concrete Anchors F
Manufacturers Space
Flush Noun
Trusses at 24" c.c.
see shop drawings
by others
transition
v apprapr
per mar
on Irk `late(
R-30 Batts Strap truss to wall
using Simpson MGT with
Simpson
HETA 20
5/8' dra.
threaded
rod with min 12" embedment
hurricane anchor
at each truss
into beam
either wet
set or in epoxy with
( 2�" O.C.)
supporting Max.
pp 9
(22) IOd
�R-II batts truss lea
nails into
ber detail
truss. Add blocking to
on this sheet
CHETA 20 1810
Ibs, uplift
ceding
ical section
I m o
I �
I
I u w
i a
I L
I
I
i I
I
I I IetS'
I
1 Stud Detall
Stud w/ Die Coat Zinc NTa
j Nickel Plated Wing Nut
er Detail
nts
II
W
2
O
Q
W
(Y
W
N I
LU L
:3 Q
WUm
7
LLIHE
IV �
uJ u-D
LLI 0 to
Z:trn
Z 1O
LLI�
I
W a
IV e8
(L
O
W
All drywall to be installed per FBC R102.3.1
i and shall meet all pertaining ASTM codes. H TA 20
ro Mortar to be Type "M" only proportioned Der FBC R601.1
and Mortar joints shall camp"lg with FBC R601.2.1.
Provide Dur-O-Rock at all wet areas (ex. showers, tubs etc...)
FIII cell with concrete and ROOF FLAN
(U 45 ppbar Vert. (typical).
48not ' unlessnotherlwi a noted exceed
Wood see foundation plan notes for - OVERHANGS AT 1'-0" UNLESS OTHERWISE NOTED ON THIS SHEET
Base spacing at openings - ROOF PITCH AT 4:12 UNLESS OTHERWISE NOTED ON THIS SHEET
4' concrete slab with Fibesh - TRUSS SHOP DRAWINGS TO BE PROVIDED BY MANUFACTURER
mil ViVlsqueen over
6"xb" #10/10 WWM on 6 mil en
clean compacted termite treated fill — ANY CHANGES TO THIS PLAN SHALL BE SUBMITTED TO THE
' ARCHITECT FOR APPROVAL iN WRITING PRIOR TO STARTING CONSTRUCTION.
III=I�I .a..`, III=IIII=IIII ;,,IIII— - ALL TRUSS TO TRUSS CONNECTIONS BY
—III— II-IIII= TRUSS MANUFACTURER
III=III =IIII IIII- - ARCHITECT TO REVIEW TRUSS SHOP DRAWINGS PRIOR
14• TO CONSTRUCTION FOR LAYOUT AND UPLIFT VERIFICATION
FI
(IIII il'' 3 TI pical Section at Front Porch - CONTRACTOR TO PROVIDE FOR FORM BOARD SURVEY AND TO PROVIDE
FORM BOARD SURVEY TO TRUSS COMPANY PRIOR TO TRUSS CONSTRUCTION
IN
VAA WA
0
��rrp;Vor F"
FOA MAE
1A Ar
e
uW7100M.
MVIEN
1-2-19
PANEL
"A"
Poles
SR
Load
Wee
Description
area
circa
Description
Wee
Load
SR
Poles
1
20
1.2 kw
a12
Rarngerator
I
Range
a6
12.0 kw
60
2
1
20
1.2 kw
912
Clothes Washer
3
1
20
1.5 kw
all
Kitchen S.A.C.
5
L
Dr or
410
5.0 kw
30
2
1
20
1.5 kw
$12
Kitchen S.A.C.
I
e
1
20
-
812
Bathroom Racapts
9
10
Air Cad ear
a10
5.0 kw
30
2
1
20
1.2 kw
012
Dishwasher
11
12
1
20
1.2 ke
a12
Microwave
13
14
Air Handier
#10
5.0 kw
30
2
1
15
-
$14
General Lighting
15
16
I
15
a14
General Lighting
n
18
WH
a10
5.0 kw
26
2
1
15
-
a14
General Lighting
19
20
I
15
-
414
General Lighting
21
22
GDO
a12
0.81 KU
20
1
I
15
-
$14
General Lighting
23
24
Spare
Spare
25
21,
Spare
Spare
21
26
Spare
Spare
29
30
Spare
PANEL "A" LOAD CALCULATION SHEET
Load Description
Qty.
Watts
Total(Watte)
General..Lightmg_ (3.,ggp..sq..rt.)................
Small. P�pphance. Circuit(s) . ........ . . . .................. ..
.Range! ....... ......... ......... ......... .................
.Refrigerator..................................................
Microwave
Dish . Washer
Clothes Washer
.CIDOSI..Prger...................,............................
Water Heater ......................
Garage. poor. Opener........................................
1135
3
5.205
2
1,500
3,000
1
12,000
I2.000
1
1,200
1,200
I
1500
1500
1
1,200
1,200
1
1,200
1.200
1
5,000
5,000
1
4500
45oo
1
810
810
Total Watts
35AIS
First 10000 Watts 9100%
1
10,000
10,000
Remainder 2SAIS e40%
1
O
10.244
Electric Heat or A/C 10,000 965%
1
10,000
10,000
Calculated Load
Watts
30,244
Voltage
240
Calculated Wattage Divided bg Voltage = Total Amps 126.02
Panel Size Required = 150 Amps
Electrical S mbol Legend
S
Single Pole Switch
®
Recessed Can Light
Sa
Double Pole Switch
®
Eyeball Recessed
PB
Push Button Switch
Exhaust Fan
Duplex Outlet
j}
Ceding Mounted Light
_0
Special Receptacle
Wall Mounted Light
Wa= ground fault circuitInt
Light with Pull Chown (attic)
®
Floor Duplex Outlet
©
Computer Connection Jack
Carbon Monoxide Detector
4&
Flood Light
(D
Thermostat
m
Electrical Panel
®
Central Vac
8
Electrical Meter
®
Smoke Detector
Ceiling fan
®
Television Jack
❑t
Telephone Jack
arc
I A/C Disconnect
®
I x 4 Florescent Light
®
2 x 4 Florescent Light
KR
Speaker Hook -Up
FB = JUNCTION BOX TO SUPPORT A PAN
O = THERMOSTAT LOCATION
B/A = BALANCED AIR
149 CFM
IOxlOx6
149 CFM
IOxlOx6
J\
12xI2x10
B/A
Vent_tFuru _-__
Sofflt $14ATH
1-2-19
FIELD VERIFY SERVICE
LOCATION RESPECIVE TO
PANEL LOCATION AND USE
APPROPRIATE RISER BELOW
A/C diac.
A/C disc.
#2/0 AL SER Cable
13) #1 THHN Copper
With #1 Grnd r
2" PVC Schedule
40 conduit
2" PVC Schedule
AMP
40 conduit sleeve
AMP
MCB
into attic
MCB
PANEL
AHU
PANEL
AHU
200a rated
200a rated
meter can
n
meter can
Intersystem bonding Interagaten bonding
2" PVC ( FPL Termination pant 2" PVC ( FPL Termination pant
schedule 80 schedule 80
2" rigid service FPL 2" rigid service FPL
GEC Bar a6 a sir ire GEC Bar aG aqppsir ire
to P2) e'- Galuvanmed to (2) 8'-O" Galvar ied
ground rods ground rods
ELECTRICAL RISER ALTERNATE SERVICE ELECT. RISER
e.
p
E 1
Opt. PATIO/SLAB
Covered Porch
I
GRE,a T
ROOM`l
I
12xI2x10 I
B/A
201 CFM Center Registers
a \ Q/]�/�-/o ceding fan 208 CFM
�1 loxox I \".4 Ioxloxl
I01
12'i
DIKING
ROOM
ill X I
a
L-- - - - - -
-
1 21 FM I42 CFM
tl 12xbxi a
10 x6
I�" 2gx2QR Al 15 CFM
- - - - Sx4x4
�i� ATH
T I
I
I-
Ix Lu
_
A is h ci N I 1 146 CFM
L - - - - - J IL 10X6)L
150 Amp Lc:__4'4Z
Meter Panel r- 8 C'tP
GARAGE
r----------------- I
I I
I I
I I
I I
I I
I I
I I
I I
I I
I I
I I
I I
SECOND
tl BEDROOM
1\ j 12xl2xe
B/A
Exhaust Duct
Thru Soffit
H.B.
Vent thru
Soffit 4" Exhaust
Duct Thru
Wall
w.p. G
Install owleAorto
under disc.not shownto
clarity
COVERED I o;
PORCH
MECH,4NIC/4L L;4Y0UT
- Contractor shall use AL-CU Landing lugs_ NTs - Contractor shall use AL-CU Landing lugs. NTs
Contractor shall torque lugs I.A.W. - Contractor shall torque lugs I.A.W. manufacturers recommendations which manufacturers recommendations which SCALE: 1/4" = Ii - Oii
shall be verified prior to construction
shall be verified prior to construction
- Verifg AIC/KIC Rating prior to ordering equipment
- Verdg AIC/KIC Rating prior to ordering equipment
ELECTRIC NOTES:
I.
Use copper wire only From panel to devices
15.
Contractor shall guarantee all materials and workmanship
free of defects for a of not less than two from
20. All equipment and panel sizes shall be verified beFore
The to
2.
Provide
and wire all required smoke t Carbon
period years
ordering. contractor shall provide circuit routings
Monoxide detectors.
the date of acceptance or certificate of occupancy, or one
suit the Job conditions.
3.
Contractor to verify location of electrical
year from closing sale of house.
service and provider.
Correction of defects shall be completed without additional
21_ Furnish and install all fixtures as called for on the plans
4.
ALL bath and kitchen receptacles to be GFCI
protected.
charge and shall include replacements or repair of any
or as selected by others.
5.
ALL exterior outlets to be WP/GFCI protected.
other phase of installation that mail have been damaged.
6.
Recessed cans to be installed per NFPA requirements.
14.
It is not the intent of these plans to show every minor detail
22• All racewags and pipes placed in or through any concrete
1.
Tamper resistant AFCI receptacles are required in
of construction. The contractor shall furnish and install
slab shall be spaced a minimum of three diameters of the
ALL rooms.
all items for a complete electrical system and provide all
largest conduit or pipe from ang other service.
S.
A/C Return Air Balance Must comply w/ FBC RM1402
the requirements necessary for the equipment to be placed in
23. All below 9'-I" be EMT
9.
A(C ReFri r�pprr��t lines that are run thru slabs must be
proper working order_
exposed wire shall installed In metal
P
sleeved inYC
11.
All work shall be done in accordance with the N.E.C. and
conduit.
10.
ALL A/C Equipment shall comply with energy calculation
shall comply with all local codes and ordinances, and shall
24. Dryer Vents to be installed per
11.
All work shall be performed by a licensed electrical
meet all standard requirements of the local electric utility
FBC RMI502
12.
contractor, the completed s stem shall be fully operative.
Contractor for Fees,
and telephone company.
shall pay all permits, testing, and
blower
13.
inspections including testing where required.
All work be coordinated trades to
18.
The electrical system shall be completely and effectively
shall with other avoid
grounded as required by the latest edition of the N.E.C.
interference with the progress of construction.
14.
All required insurance shall be provided For protection
19.
All material shall be new and shall bear underwriters'
against the public liability and property damage for the
labels where applicable.
-
duration or the work.
Ai C
Meter
MASTER c
BEDROOM
i
16"
S�L_-_U_--
CLOSE
Opt. PATIO/SLAB
Covered Porch
1 \
\ I
\ I
� r
w.p. GFI
v v I �u
Smoke / Carbon G R E T
Monoxide Detector R O M
Combo
I
s I
CM
I
I
i�
II
II
II
I I
I I
I I DINING
``GF 1 1 Room
I
4-
I \ o I
�i KITCHEN I �I
L - _5Dok€ L GArb-o
Monoxide Detector
/24Combo" I 3'-2" 3'-2" � � CHInE6 4F- � -
-oB AT
�I 50 CFM
0 F N
G I GFI 1
42"h GFIII W.H. E
- - - - -
11(m �
Cente
22"x 54" , 17, Q \
` I A cc
aKh tight ~ , \
L J Lt_] `\SECON'D---
150 AMR Optional BEDROOM
Panel Pc� panel location ® $
Pull chainl i$ T \\
\ light in attic
GARAGE AGE 42"h GFI
� e PB
II Garage
/VjJj J� Door �
Opener \
r-----------------1 1
1 \N
I I
I I IN,
I I
I I
I I RSEr
FCF-0-R C H
ELECTRICAL PLAN
Braden It
Braden AIA, PA
Architects
- Planners
'411
S.E. Coconut Avenue
Tel :
(112) 281-8258
Fax
: (112) 281-8283
E-mail:
bradenaiaecomcast.net
Stuart. FL
34994 UAAC000032
l
SCALE: 1/4" = I'-O"
Attic Ventirici Calculations FBC 2309.1
Total Attic Space = 212-4 sq. ft.
Venting Ratio 1/150 = 1-4.16 sq. ft. required
Provide A Continuous Vented Soffit
Post Light with,- ° o
Photo cell I N
v
H.B.
Exhaust Duct
Thru Soffit
a-
Wiirre For
Front Post
Light
Wgnng
THE
Building Corp.
STERLING
MODEL:
GARAGE
LEFT
11 ISLANDIA
Date Drawn :
3-31-20
Drawn by:
C.C.U.
Checked by:
D.R.B.
Revisions :
REVIEWED FOR
CODE COMPLIANCE
ST. L.UCIE COUNTY
Sheet
F - 1
OF 5
Comm 4
20-0
Spanish Lakes
St. Lucie Countg Florida
shop drawing approval is NOT..a
"double check" of the contractor.
- The contractor shall: remain responsible
for checking field measurements and
other construction criteria. Architect's
approval covers general roof shape,
review of truss strapping, and loading on
structure from gravity and uplift loads and
TRUSSES FOR THE FIRST MODES SH UI-D BE SHIPPED ,AND SUCCES SFUI_!_Y SET BEFORE ANY MORE TRUSSES AKr BUILT 0� IAT MODE. their re active locations .'
Approved By:.1// .-
�► ARRANGE WITH CRANE OPERATOR IN ADVANCE FOR A SPREADER BAR OF 18'- 24' IN LENGTH
�h
30' Span or less 30° to 60' Span A o not stand on trusses until they are braced per BCSI pro erly nailed to straps angers
o degrees Spreader BarAj'
or less'
r
i
:- 1/ 2 _— ag F'-- APprox 2/3 to
T g Line span approx. Line 1/2 of span
REFER TO BCSI REFER TO BCSI
Truss must be set this way if crone7.eedTruTss.m,,u9.trbe setthis way if crone used.
Truss is an example. your truss me, net mexample, truss may not match.
AIF-2 HAIIIV�1___�R NG7T�
UNLESS NOTED ELSEWHERE ON THIS LAYOUT, THESE TRUSSES
ARE NOT DESIGNED FOR AIR HANDLERS IN THE ROOF OR FOR
ANY OTHER A/C REQUIREMENTS, THIS MAY BE IN CONFLICT
WITH BUILDING ICODE AND A/C DESIGN REQUIREMENTS.
CONSULT WITH BUILDING DEPARTMENT AND A/C CONTRACTOR.
/L
� /CL�(L � L
Insist crone operator sets truss this way. Insist crane. operator sets truss this way. - -
Carrying Girder
For Truss to Truss
Connections see
hanger/connectorTDome
be as
de tabs o
schedule in engineeringanails.
package.
Carried Truss
SEAT PLATES ®Y CHAMBERS
12
4.00 F—
zo
to 2.0012
�}8_—
cn
r
upset=1/4" heel=315/16"
PLUMB CUT END
2 x 4 Top Chord
WALL HEIGHT 8'
END DETAIL: TYPICAL VAULT
to
12
4.00 17—
io
1'
upsi l/4" heel=315/16"
PLUMB CUT END
2 x 4 Top Chord
WALL HEIGHT 8'
TYPICAL END DETAIL
I
t INDICATES LOAD BEARING
REQUIRED BY TRUSSES
SUPPLIED BY BUILDER
ATA HEIGHT OF li
ABOVE FINISHED FLOOR
1
M
pop
IMP
r
/ AN
i �P,
--
�■_
®�
/1
�—
—
-
ATA
®
.■�■_
a
■—
®
••a
ATA
®,
ATAPON
BHA
��■■�■�■��■��■���■.�
"���I��:■�■ley
I,
r
I•
r
I•
r
'I
'/
Ir
it
w\�i
•
••
I®��I®I®I®I®I®I®
i®I�I®I�I�I®�®
I I
5'4 3'4
GARAGE LEFT
rA
Q
m
m
m
m
m
J2
2
J4
4
J6
6
GRA
Al
3
5
1,
5
5
AV
A5
A5
A5
A5
At
ATA
IATS
_
J
bo
TD
J
—
N
R
V)
ep
a)
r0
W
c0
as
m
W
W
m
U)
V
N
�
A
o
i\
J
J
m
2.0... INT .001 NT.� I
. I
2,
_ 13'-6"
�
� I
I
I
ATA
'
- ATA
�
INVERTED "V" WEBS AT CENTER
WI9' B.C. PANNEL. LOAD WI (2)
50p POINT LOADS PER TRUSS FOR A/H/U
ATA
ATA
ATA
ATA
�' B
I
i
•� BHA
I
I
�
�
1
J2
Date:--- —
Braden
.& Braden A.I.A. P.A.
FABRICATION AGREEMENT
TRUSSES CANNOT BE STARTED UNTIL THIS AGREEMENT IS SIGNED & RETURNED
The legal description of the property where the trusses will be Installed is:
The undersigned acknowledges and agrees:
1. Trusses will be made in strict accordance with this truss placement diagram layout,
which Is the sole authority for determining. successful fabrication of the trusses.
2 All dimensions In this layout have been verified by the undersigned.
.3, Unless written nodes Is provided by certified mall to Chambers Trues within ten (10)
days of delivery the underslgnod agrees that no backcha ees will be allowed., in the event
such written notice is fumished Chambers Truss shall have three (3) bu�nass days in which
to begin repairs required, or to substitute othectrusses, at Chambers optlon.l
4. The undersigned acknowledges nacelpt o1 "BCSI 1-03' summary sheet �y'rPl & VVTCA.
S. Delivery is to Job site, It Is the buyer's' responsibility to make the job site suitable for
delivery. Chambers Truss has the sole authority to determine the suitability of the Job site or a
potion of the Job site for delivery. Chambers Truss will be responsible for dump delivery only,
The buyer Is responsible for additional delivery expenses If Chambers Truss has to redeliver
because Job she Is not prepared for delivery or buyer Is not prepared for delivery of trusses,
Guyer Is responsible to Chambers Truss for towing costs duo to she conditions.
B. Price as shown In paragraph 7 below Is subject to change If any changes em. made in
this layout A $50 per hour fee for revisions may be charged by Chambers Truss,
7. This is a PURCHASE ORDER to Chambers, Truss of the sum agreed to, or If ne,
agreement a reasonable price. Involve will be made on delivery and paid within terms of net
on delivery. Invoice may. be made at scheduled date of delivery It buyer cannot accept..
delivery of fabricated trusses, The undersigned agrees to pay Chambars.Truss reasonable
attorneys fee for Whections In event of payment not timely made. 1-12 %, por month service
charge will be added for all sums not paid within terms. -
a. Signature or Initials anywhere on this sheer constitutes agreement to all terms herein,
ee in consideration of Chambers Truss extending credit for this material the undersigned
unconditionally guarantees payment when due of any and all indebtedness owed to
Chambers Truss by any entity receiving material and the undersigned agrees to pay such
Indebtedness Including attorneys fees, If default in payment for material 6e made by the
recipient.
10, In the event of any litigation concerning this agreement, the items furnished hereunder
e Bola referred to herein the parties ag
ree lea the. the sale venue for any u
payments � � P g y such action will
be Saint Luce County, Florida. I '
11. Design responsibilltles are per "National Standard And Recommerl Guidelines On
Rasponlbilldes For Construction Using Metal Plate Connectetl Wood Trusses
ANSVrPIWTCA 4 - 2002" .
DATED
SIGNED
FOR TITLE
I _
A spreader bar maybe regt(lred per "BCSI 1-V' to prevent kVuiY & �9e•
Multiple ply trusses must be fastened togithar per engineering
before they are set, failure to do so can result In root collapse.
Temporary and permanent bracing are required and can save life
and property and Is the resp_nsfbllity of the truss erector.
Study the contents of the Information packet Included on delivery
before setting trusses.
Trttseas must be setand braced pe�lieslgn m Pit �ltrY6 dansage,
Trusses must be set plumb and square
Do not set bunks or stack of plywood, roofing material or any
other concentrated loads on trusses, this can cause collapse.
DO NOT SET TRUSSES USING THIS L4YOUT
USE LAYOUT DELIVERED WITH TRUSSES TO SET TRUSSES
CHAMBERS TRUSS INC
3105 Oleander Avenue
Fort Piercer Florida 34982-6423
800-551-5932
Fort Pierce 772-466-2012 Fax 772.465-8711
Vero Beach TT2 569-2012 Stuart 772-288 3302 '
92.0/93.2 MITEK 4.2
DESIGN CRITERIA
County SAINT LUCIE
Building Department ST LUCIE COUNTY
Wind Design Criteria ASCE 7-2010
Wind Design Method MWFRS/C-C hybrid Wind ASCE 7-10
Roofing Material Shingle or Shake
Loading in li Roof R.D.L:
00 �, Top Chord Live 20
R ., , Top Chord Dead 7 4.2
�+ 0 Bottom Chord Live 10 Non -Concurrent
Bottom Chord Dead 10 3
0 _ , TOTAL Load 37 7.2
w H Duration Factor 1.25
m = Wind Speed 165mph
L ;, Top Chord C.B. Sheeting by builder.
`—° Bottom Chord C.B. Sheeting by builder.
H Highest Mean Height 12'-0"
Building Type ENCLOSED
Building Category II:Non Restrictive
Exposure Category C
Barrier Island No
Conforms to FBC 2017
I Building Designer and/or Engineer of Record.
Chambers Truss Inc. Drawing Name: M11412
Scale: 1 /4 = 1'
73 total trusses, 18 different trusses.
.� MI 4: RLC ACAD: RLC Reviewed By:
- - Date: 11/14/16 Revised: 10/23/18
a FOR
1T-6• S-4- rat /EDWNNE DEVELOPMENT CORP.
�� 5'-4" � 15'-10" _�
— SOD , MP
sou � ��E�IIPTION:
GARAGE RIGHT�,.TFLING
PAGE 1 of 1 CUSTOMER INITIALS EACH PAGE
18 TRUSS DRAWINGS ARE ATTACHED TO LAYOUT M 11412