Loading...
HomeMy WebLinkAboutEnergy CodeFORM R405-2017 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method ProjectName: WYNNE THE GRAND CARLTON IMPACT BuilderName: WYNNE BUILDING COPR. Street: 11;t 71 cl� q� n Ci Permit Office: ST. LUCIE.000NTY City, Slate, Zip: FT. PIERCE, FL, PennitNumber: Owner: WYNNE BUILDING CROP Jurisdiction: ST. LUCIE COUNTY DesignLocalion: FL, Fort Pierce. County: SL Lucie (Florida Climate Zone 2) 1. New construction or existing, New (From Plans) 9. Wall Types(1442.0 sgft.) Insulation Area 2. Single family or multiple family Single-family a. Concrete Block- Int lnsul, Extedor R=4.1 1250.00 ft' b. Frame -Wood, Adjacent R=11.0 192.00 ft2 3. Number of units, if multiple family 1 c.N/A R= 112 4. Number of Bedrooms, 2 d•N/A R= ft2 IO.Ceiling Types (1476.0 sgft.) Insulation Area 5. Is lhisaworsl case? Yes a. UnderAttic(Vented) R=30.0 1446.00 ft2 6. Conditioned Ooorarea above grade (ft2) 1446 b. Knee Wall (Vented) R=19.0 30.00 ft2 Conditioned 9oorarea below grade (ft') 0 c.N/A R= ft2 11. Ducts R ft2 7. Wmdows(141.3 sqft.) Description Area a. Sup: Attic, Ret: Attic, AH: Attic 6 175 a. U-Factor: Sgl, U=1.04 101.25 ft2 SHGC: SHGC=0.29 b. U-Factor: Sgl, U=1.11 40.00 ft2 12. Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.27 a. Central Unit 34.8 SEER:15.00 C. U-Factor: N/A ft' SHGC: 13. Heating systems kBtu/hr Efficiency d. U-Factor: NIA ft2 a. Electric Heat Pump 34.8 HSPF:8.50 SHGC: Area Weighted Average Overhang Depth: 3.832 ft. Area Weighted Average SHGC: 0284 14. Hotwalersystems A. Electric Cap:40gallons 8. FloorT es (1445.5 sqft.) Insulation Area YP EF: 0.970 a. Slab -On -Grade Edge Insulation R=0.0 1445.50 ft' b. Conservation features b. NIA R= ft' None c. NIA R= ft2 15. Credits Patel Glass/Floor Area: 0.098 Total Proposed Modified Loads: 47.50 PASS Total Baseline Loads: 48.09 I hereby certify that the plans and specifications covered by Review of the plans and 4T STg7 this calculation are incompliance with the Florida Energy specifications covered by this ,y� 0 leoA Code. calculation indicates compliance 1. �O ��1i with the Florida Energy Code. rnd(�. %-° f PREPARED BY:. Before construction is completed r� Ts'"�Y DATE: I q-2f) this building will be inspected for compliance with Section 553.908 9sr 4)li- • ' o I hereby certify that this building, as designed, is in compliance Florida Statutes. !� COD with the Florida Energy Co W£1� OWNER/AGEN5: BUILDING OFFICIAL: DATE: � \ rid DATE: Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2). 1AEVIEWpE�® FyOpp"�CE 1/8/20204:18 PM EnergyGauge@ USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th F,dgior�(0 C9r I�' gCBolW4N Pagel of L JSVVTe. LU LUNTY OCO FORM R405-2017 INFO I SUMMAKT UHt:t:KLIJ I KCI'UKI PROJECT - Title: WYNNE THE GRAND CARLT Bedrooms: 2 Address Type: StreetAddress Building Type: Usei - CondibonedArea: 1446 Lot# OwnerName: WYNNE BUILDING CROP Total Stones: 1 Block/Subdivision: #of Units: 1 Worst Case: Yes PlatBook: BuilderName: WYNNE BUILDING COPR. RotateAngle: 180 Street: Permit Office: ST. LUCIE COUNTY CrossVentilation: No County: St. Lucie Jurisdiction: ST. LUCIE COUNTY Whole House Fan: No City, State, Zip: F.T. PIERCE, ' Family Type: Single-family FL, New/Fxisting: New (From Plans) Comment: CLIMATE / Design Temp Int Design Temp Heating .Design DailyTemp DesignLocation TMYSite 97.5% 2.5% Winter Summer Degree Days Moisture Range FL, Fort Pierce FL_VERCIBEACH MUNI 39 90 70 75 299 62 'Low BLOCKS Number Name Area Volume 1 Entire House 1446 11568 " SPACES' Number Name Area Volume Kitchen Occupants Bedrooms Infil ID Finished Cooled Heated 1 BEDROOM 301 2408 No 0 1 1 Yes Yes Yes 2 WIC 63 504 No 0 1 No Yes Yes 3 M.BATH 56 448 No 0 1 Yes Yes Yes 4 KITCHEN 192 •1536 Yes 0 1 No Yes Yes 5 BATH 45 360 No 0 1 Yes Yes Yes 6 BEDROOM 2 204 1632 No 0 1 1 Yes Yes Yes 7 ENTRY 55 440 No 0 1 Yes '.Yes Yes 8 LAUNDRY 42 336 No 0 1 Yes Yes Yes 9 GREAT/DINING 488 3904 No -. 0 1 Yes Yes Yes FLOORS # FloorType Space Perimeter, PenmeterR-Value Area JoistR-Value Tile Wood Carpet ' 1 Slab -On -Grade Edgelnsulation BEDROOM 52 ft 0 301 ft' ---- 0 1 0 2SIab-On-GradeEdgeinsulallon WIC 1 ft 0 63 ft' ---- 0 1 0 3 Slab -On -Grade Edge Insulation M•BATH 8ft 0 56 ft' _--- 0 -. 1 0 4 Slab -On -Grade Edge Insulation KITCHEN 1 ft 0 192,ft' --- 0 1 0 5 Slab -On -Grade Edgelnsulation BATH 5ft 0 45 ft' ___- 0 1 0 6 Slab -On -Grade Edge Insulation BEDROOM2 .32.2ft 0 203.5 ft' - — - 0 1 0 7 Slab -On -Grade Edgelnsulation ENTRY 7ft 0 55 to ---- 0 1 0 1/812020 4:18 PM . EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 2 of 5 .FORM R405-2017 INPUT SUMMARY CHEGKL15T REPORT FLOORS # FloorType Space Perimeter PedmeterR-Value Area Joist R-Value Tile Wood Carpet 8 Slab -On -Grade Edge Insulation LAUNDRY 6ft, 0 42 ft' ____ 0 1 0 9 Slab -On -Grade Edge Insulation GREATIDINING 46ft 0 488 it' _�_ 0 1 0 ROOF / Roof Gable Roof Red Solar SA Emil Emitt Deck Pitch Type Materials Area Area Color Barr Absor. Tested Tested Insul. (deg) 1 GableorShed Metal 1524 ft' 240 ft' Light N 0.6 No 0.9 No 0 18.4 ATTIC. / V # Type Ventilation' Vent Ratio (I in) Area RBS IRCC. 1 Full attic Vented 150 1446 ft' N N CEILING # CeilingType Space R-Value Ins Type Area Framing Frac Truss Type _ 1 UnderAttic(Vented) BEDROOM 30 Blown 301 ft' 0.1 Wood 2 UnderAttic(Vented) WIC 30 Blown 63 ft' 0.1 Wood 3 UnderAttic(Vented) M. BATH 30 Blown S6.ft' 0.1 Wood 4 UnderAtOc(Vented) KITCHEN 30 Blown 192 ft' 0.1 Wood _ 5 UnderAttic(Vented) BATH 30 Blown 45 fP 0.1 Wood .6 UnderAttic(Vented) BEDROOM 30 Blown 204 ft' 0.1 Wood 7 UnderAttic(Vented) ENTRY 30 Blown 55 ft' 0.1 Wood _ 8 UnderAttic(Vented) LAUNDRY 30 Blown 42 fN 0.1 Wood _ 9 UnderAttic(Venled) GREATIDINING 30 Blown 488 ft' 0.1 Wood 10 KneeWall(Vented) GREAT/DINING 19 Blown 30 ft' 0.11 Wood WALLS Adjacent Space Cavity Width Height Sheathing Framing. Solar Below _ 1 NE=>SW Exterior Concrete Block- Int lnsul BEDROOM 4.1 10 0 8 0 80.0 ft' 0 0 0.4 0 _ 2 SW=>NE Exterior Concrete Block- Int lnsul BEDROOM 4.1 28 0 8 0 224.0 ft' 0 0. 0.4 0 _ 3 NW=>SE Exterior Concrete Block- Int lnsul BEDROOM 4.1 14 0 8 0 112.0 fl' 0 0 0.4 0 _ 4 SW=>NE Exterior Concrete Block -Int lnsul M. BATH 4.1 8 0 8 0 64.0 fP 0 0 0.4. 0 _ 5 NE=>SW Exterior Concrete Block -Int lnsul BATH 4.1 5 0 8 0 40.0 ft' 0 0 0.4 0 6 NE=>SW Exterior Concrete Black- IntlnsuBEDROOM 2 4.1 16 0 8 0 128.0ft' 0 0 0.4 0 7 SE=>NW Exterior Concrete Block- IntlnsuBEDROOM 2 4.1 10 0 8 0 80.0 ft'. 0 0 0.4 0 8 S=>N Exterior Concrete Block= Int lnsuBEDRGOM 2 4.1 4 3 8 0 34.0 ft' 0 0 0.4 0 9 SW=>NE Exterior Concrete Block- Int lnsuBEDROOM 2 4.1 2 0 8 0 16.0 fN 0 0 0.4 0 10 SE=>NW Exterior Concrete Block -Int lnsul ENTRY 4.1 6 0 8 0 48.0 ft' 0 0 0.4 0 11 SW=>NE Exterior Concrete Block -Int lnsul ENTRY 4.1 1 0 8 0 8.0 ft' 0 0 0.4 0 12 SW=>NE Exterior Concrete Block- Int lnsul LAUNDRY 4.1 6 0 8 0 48.0 ft' 0 0 0.4 0 13 NE=>SW Exterior Concrete Block -Inl lnsuGREAT/DINT 4.1 26 0 8 0 208.0 ft' 0 0- 0.4 0 14 NW=>SE Exterior Concrete Block- Int lnsuGREATIDINI 4.1 20 0 8 0 160.0 ft' 0 0 0.4 0 1/8120204:18 PM EnergyGauge®USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition(2017)Compliant Software . Page 3of5 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT WALLS Adjacent Space .Cavity WidthA. ' Height Sheathing Framing Solar Below 15 N=>S Garage Frame -Wood KITCHEN 11 24 8 192:0 ft- 0.23 0.4 0 DOORS # Ornt DoorType Space Storms U-Value Width Ft In Height Ft In Area 1 SE=>NW Insulated ENTRY None .39 3 1 6 8 _ 20.6 ft' WINDOWS Odenlatiorshown is the entered orientation => changed to Worst Case. Wall # Omt ID Frame Panes I Overhang NFRC U-Factor SHGC Imp Area Depth Separation IntShade Screening 1 NW=>SE 3 Metal _ 2. SW=>NE:4 Metal 3 SE=>,NW 7 Metal _ 4 NE=>SW13 Metal 5—NW=>SE14 Metal Low-ESingle Low-ESingle Low-ESingle Low-ESingle Low-ESingle Yes 1.04 0.29 Y 32.9 ft' 1 ft 0 in 1 ft 5 in Yes 1.04 0.29 Y 6.9 ft' 1 ft 0 in 1 ft 5 in Yes 1.04 8:29 Y 24.0 ft' 6 ft 0 in 1 It 5 in Yes 1.04 0.29 Y 37.5 ft- 1ft0in 1ft51n Yes 1.11 0.27 Y 40.0I 8ft01n 1ft5In Drapes/blinds. None None None Drapes/blinds Extedor5 None None None Exledor5. GARAGE # FlcorArea CeilingArea Exposed Wall Perimeter Avg.Wall Height Exposed Wall Insulation 1 31511' 315.ft' 24ft 8ft 11 INFILTRATION, # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 ' Wholehouse ProposedACH(50) .000356 1349.6 74.09 139.34 .1233 7 HEATING SYSTEM # System Type Subtype . Speed Efficiency Capacity Block Ducts 1 Electric Heat Pump/ Split Single HSPF:8.5 34.8 kBtu/hr 1 sys#1 COOLING SYSTEM # System Type Subtype Subtype Efficiency Capacity Alr Flow SHR Block Duds 1 CentralUnitt Split Single SEER:15 34.8 kBtulhr , rim 0:8 1 sys#1 HOT'WATER SYSTEM # System Type SubTpe Location EF _ Cap Use SetPnt Conservation 1 Electric -None Garage 0.97 40gal - 60.9gal 120deg None 1/8/20204:18 PM EnergyGauge®USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition(2017) Compliant Software Page'4 of FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT SOLAR HOT WATER SYSTEM FSEC Collector , Storage Cart # CompanyName System Model# CollectorModel# Area Volume FEF None None ft2 DUCTS / —Supply-- —Return— Air CFM 25 CFM25 HVAC# V # .Location R-Value Area Location Area LeakageType Handler TOT OUT ON RLF Heat Cool 1 Attic 6 175 ft2 Attic 66ft2 Defaulti-eakage Attic (Default) c(Default) c 1 1 TEMPERATURES Programabl[er)TC')hermostat:Jan Y Crlelling Fans:Cooling ftFebrrXX''t1 rr frfr f`f` ftX Aug t0( r Sep Oct HNov Dec Venting [ ]Jan [ ]ov Feb [X]ct Mar Apr [ Maymay [x�Jun [X�JuI [ [ Dec ThermostatSchedule: HERS 2006 Reference Hours ScheduleType 1 2 3 4 5 6 7 8 9 10 11 12 Cooling IWO) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling(WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 '78 78 Heating IWO) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating(WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 MASS Mass Type Area Thickness FumitureFraction Space Default(8lbs/sq.ft. 0 ft2 0 ft 0.3 BEDROOM Default(8lbs/sq.ft. 112 ft 0.3- WIC Default(8lbs/sq.ft. ft2 ft 0.3 M. BATH Default(8lbs/sq.ft. ft2 ft 0.3 KITCHEN Default(8 lbs/sq.fL ft2 ft 0.3. BATH Defaull(8lbs/sq.ft. ft2 ft 0.3 BEDROOM 2 Default(8lbs/sq.ft. ft2 ft 0.3 ENTRY Oefault(8lbs/sq.fL ft2 ft 0.3 LAUNDRY Default 8lbs/s .fL ft2 ft 0.3 GREATIDINING 1/8/2020 4:18 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 5 of 5 2017 -AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: WYNNE THE GRAND CARLTON IMPACT Builder Name: WYNNE BUILDING COPR. Street: Permit Office: ST. LUCIE COUNTY - City, State, Zip: FT. PIERCE, FL, Permit Number: Y U Owner: WYNNE BUILDING CROP Jurisdiction: ST. LUCIE COUNTY w x Design Location: FL, Fort Pierce � COMPONENT AIR BARRIER CRITERIA INSULATION INSTALLATION CRITERIA General A continuous air barrier shall be installed in the building envelope. Air -permeable insulation shall The exterior thermal envelope contains a continuous air barrier, not be used as a sealing material. requirements Breaks or joints in the air barrier shall be sealed., Ceiling/attic The air barrier in any dropped ceiling/soffit shall be aligned with The insulation in any dropped ceiling/soffit the insulation and any gaps in the air barrier shall be sealed. shall be aligned with the air barrier. Access openings, drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Walls The junction of the foundation and sill plate shall be sealed. Cavities within comers and headers of frame walls The junction of the top plate and the top of exterior walls shall be shall be insulated by completely filling the cavity sealed. with a material having a thermal resistance of R-3 Knee walls shall be sealed. per inch minimum. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Windows, skylights The space between window/doorjambs and framing, and and doors skylights and framing shall be sealed. I Rim joists Rim joists shall include the air barrier. Rim joists shall be insulated. Floors The air barrier shall be Installed at any exposed edge of Floor framing cavity insulation shall be installed to (including insulation. maintain permanent contact with the underside of above -garage subfloor decking, or floor framing cavity Insulation and cantilevered shall be permitted to be in contact with the top side floors) of sheathing, or continuous insulation installed on the underside of floor framing and extends from the bottom to the top of all perimeter floor framing members. Crawl space walls Exposed earth In unvenled crawl spaces shall be covered with Where provided instead of floor insulation, insulation a Class I vapor retarder with overlapping joints taped. shall be permanently attached to the crawlspace Shafts, penetrations Duct shafts, utility penetrations, and flue shafts opening to exterior or unconditioned space shall be sealed. Batts in narrow cavities shall be cut to fit, or narrow Narrow cavities cavities shall be filled by insulation that on installation readily conforms to _the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spac 3s. Recessed lighting Recessed light fixtures Installed in the building thermal envelope Recessed light fixtures installed in the building shall be sealed to the drywall. thermal envelope shall be air tight and IC rated. Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring and plumbing in exterior walls, or insulation that on Installation readily conforms to available space shall extend behind nin'na an wirina Shower/tub The air barrier installed at exterior walls adjacent to showers and Exterior walls adjacent to showers and tubs shall on exterior wall tubs shall separate them from the showers and tubs. be insulated. Electrical/phone box or The air barrier shall be installed behind electrical or communication exterior walls boxes or air -sealed boxes shall be installed. HVAC register boots HVAC register boots that penetrate building thermal envelope shall be sealed to the sub -floor or drywall. Concealed When required to be sealed, concealed fire sprinklers shall only be J sprinklers sealedin a manner that is recommended by the manufacturer. Caulking or other adhesive sealants shall not be used to fill voids between fire snrinklpr cover nlates and walls or ceilinas, a. In addition, inspection of log walls shall be in accordance with the provisions of ICC-400. 1/8/2020 4:19 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1 2017 EPL DISPLAY CARD ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 99 The lower the Energy Performance Index, the more efficient the home. 1. New home or, addition 1. New (From Plans) 12. Ducts, location & insulation level a) Supply ducts R 6.0 2. Single-family or multiple -family 2. Single-family b) Return ducts R 6.0 c) AHU location Attic 3. No. of units (if multiple -family) . 3. 1 4. Number of bedrooms 4. 2 13. Cooling system: Capacity 34.8 a) Split system SEER 15.0 5. Is this a worst case? (yes/no) 5. Yes b) Single package SEER c) Ground/water source SEERICOP 6. Conditioned floor area (sq. ft.) 6. 1446 d) Room unitIPTAC EER e) Other 7. Windows, type and area a) U-factor.(weighted-average) 7a. 1.060 b) Solar Heat Gain Coefficient (SHGC) 7b. 0.284 14. Heating system: Capacity 34.8 c) Area 7c. 141.3 a) Split system heat pump HSPF 8.5 b) Single package heat pump HSPF 8. Skylights c) Electric resistance COP a) U-factor:(weighted average) 8a. NA d) Gas furnace, natural gas AFUE b) Solar Heat Gain Coefficient (SHGC) 81b. NA e) Gas furnace, LPG AFUE f) Other 9. Floor type, insulation level: a) Slab -on -grade (R-value) 9a. 0.0 b) Wood, raised (R-value) 9b. 15. Water heating system c) Concrete, raised (R-value) 9c. a) Electric resistance EF 0.97 b) Gas fired, natural gas EF 10. Wall type and insulation: c) Gas fired, LPG EF A. Exterior: d) Solar system with tank EF 1. Wood frame,(Insulation R-value) 10A1. e) Dedicated heat pump with tank EF_ 2. Masonry (Insulation R-value) 10A2. 4.1 f) Heat recovery unit HeatRec%* B. Adjacent: g) Other 1. Wood frame (Insulation R-value) 10131. 11.0 2. Masonry (Insulation R-value) 10B2. 16. HVAC credits claimed (Performance Method) 11. Ceiling type and insulation level a) Ceiling fans a) Under attic 11 a. 30.0 b) Cross ventilation No b) Single assembly 11b. c) Whole house fan No c) Knee walls/skylight walls lid. 19.0 d) Multizone cooling credit d) Radiant barrier installed 11d. No e) Multizone heating credit f) Programmable thermostat Yes *Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. I certify that this home has complied with the Florida Building Code, Energy Conservation, through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL display card will be completed based on installed code compliant features. Builder Signature: Date: Z-A Address of New Home: �1.4�^nI City/FL Zip: FT. PIERCE, Fl- 1/8/2020 4:19:34 PM EnergyGauge® USA 6.0.04 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1