Loading...
HomeMy WebLinkAboutft pierce engineeringArchitectonic Inc June 26, 2020 City of Fort Pierce Building Department 100 North US 1 Fort Pierce, FL Re: Shutter specification prepared for the City of Fort Pierce for the structure located at, 3202 Oleander Avenue, Fort Pierce, FL 34982 Manufacturer: Profiles: Code: Wind Speed: Exposure: Mean Roof Height: Required Design Pressure: Maximum Pressure: Base Attachment: Head Attachment: American Shutters Systems Association Bertha HV Accordion Shutter Blade 1 Only, FL# 389.2 FBC 2017 160 MPH; Ultimate Design Wind Speeds C 26' Maximum Zone 4: -33.88 Zone 5: -41.14 +70/-75 Detail Il trench installation with'b" Tapcons @ 6" o.c., with 1-1/2" min. embedment MS wall header/sill installation withX' 0 x 3" self -drilling bolt in lieu of/." 0-20 x 3 bolt with''/." aluminum sleeve @ 6" o.c. The above approved, as per Florida Building Code Compliance acceptances, 2017 Florida Building Code, and the Manufacturer's recommendations. 806 Delaware Avenue Tel: 772 460 7751 www.architectonicinc.com Fort Pierce, Florida 34950 Fax: 772 460 4244 FL Reg #AA26003348 1 of 1