Loading...
HomeMy WebLinkAboutTR20-7965B Foundation Stab Rpt-Helicon - DS Technical Report #20-7965B PARTIAL-FOUNDATION STABILIZATION REPORT ASSET: WILSON RESIDENCE LOCATION: 4911 BALD CYPRESS TRAIL FORT PIERCE, FL 34951 SAINT LUCIE COUNTY CLIENT: HELICON FOUNDATION REPAIR SYSTEMS, INC. JAY SILVER 11103 N 46t" ST, BLDG B TAMPA, FLORIDA 33613 TEL: (813) 567-1065 FAX: (813) 864-4461 June 22, 2020 AWARD ENGINEERING, INC. 7804 N. FLORIDA AVENUE, TAMPA, FLORIDA 33604 Phone- (813) 238-4393; Fax- (813) 237-3909; E-mail- awardengineering@yahoo.com Website: http-//www.awardengineering.com T.R. #20-7965B AWARD ENGINEERING, INC. 7EO4 N. FLCRIDA AVENUE, TAMPA, FLORIDA 336CI4 Phone: (813) 238-43193; Rax: (813) 237i-3909; E-mail: awardencineeriinc Ca,yahoo.com Website: http:ilwww.awarcengineering.com Helicon Foundation Repair Systems, Inc. June 22, 2020 Jay(Silver 11103 N 46th S11, Bldg B Tampa, FL 33E 13 Tel: (813) 567-1065 i Rax: (813) 864-44E1 RE: Technical Report#20-7965B: PARTIAL-ROUNDIATION STABILIZATION REPORT: Wilsicn Residence 49' 1 Bald Cypress Trail Rod Pierce, RL 34SI51 (Saint Lucie County) (Parcel: 1418-132-CI040-000-4) Deari Sir/Macam: Rer your requesdl, AWARD Engineering, Inc. has designed a Rartial-Foundation Stabilization Program consisting of a pressure pier underpinning system for the above referenced location. The repair work was performed by Helicon Foundation Repair Systems, Inc. (CBC #125531CI). Following ccmpletlion of the work, AWARD Engineering inspected the provided insdlallaticn logs and phctlosi. This letter summarizes the underpinning pier installation by Helicon. The underpinning system was installed on June 11 and June 12, 2020. A total of iourteen (14) pressure piers were installed at selected locations along 11he exterior walls of the structure including the southeast corner section, the norihwesdl corner section, and in the pool deck area. Per the request of the homeowner, Pressure Pier SP12 wasi relccailec from its proposed locallion. See attachec As-Installed Rlan for approximate pier locations. The pressure piers were installec to ceptHs ranging from thirty-twc (212) to foray-fcur (44) feet below grcunc surface. Individual installation records showing depth and applied pressure for each pier are also attached. Basec on the prcviced information, it is the opinion of AWARD than Helicon Roundation Repair Systems, Inc. has completed the installation of this Rartial-Fcuncaticn Stabilization System in accordance with generally accepted industry standards and practices to the best of cur belief and knowledge and 11hat the foundation of the structure at the repaired locations is stabilized at this time. The scope of this report does not cover any problems that may occur in areas beyond the limits of this repair work or as a result of pre-exisdlinc, conditions. The prcposec plan by AWARD Bncineering, Inc. was Iimillec 110 the iouncation stabilization of the structure at the repaired locations, based on our client's request for a pressure pier uncerpinning plan. This remediaticn is nail intendec to mitigate any deep soil conditions or to provide a remediaticn for any sinkhole sitatus that might exist at the site. AWARD appreciates this opportunity to be of service. Do not hesitate to contact cur office to answer any questions you may have concerning this report. Respectfu% sufrlMi r, /CCC Digitally signed by ._�`� • .41•.•i I""A Hovhannes Mouradian,PE •"' '� • DN.c=us,s Florida,-Z2 Z Hovhannes Brandon o Hovhannes 9, Mouradian AM„°n nnePE, Hovhanjk Motes a..,.......Monad PES ema l ho i—. 6d @g Prof io% En inegr##71Q439 -°M -1— '" Date 2020 06 26 12.06:38 Stag of Fla�ariday -g°°° Ple"I rAztog;he attachid s�eeils'for locatiors,cates,anc plar(s): Attec "A Propost�d_LndErpinring Plar,As-Installed Uncerpinning Plan,Pier Data Sheets AltachMeWv.' Site PRotbgraphs AWARD Engineening, Inc. T.R. #20-7965B ATTACHMENT "A" Sheet #1 : Proposed Underpinning Plan Sheet #2: As-Installed Underpinning Plan Pier Data Sheet(s) (Sheets #1 to #3) AWARD Engineering, Inc. PROJECT NOTES REVISIONS BY • ALL CONSTRUCTION SHALL COMPLY WITH APPLICABLE CODES AND STANDARDS,INCLUDING BUT NOT LIMITED TO ALL STATE LAWS,LOCAL ORDINANCES,UTILITY COMPANY, Z FLORIDA ACCESSIBILITY CODE FOR BUILDING CONSTRUCTION,THE OCCUPATIONAL SAFETY AND HEALTH ACT,NFPA AND THE CURRENTLY ADOPTED. SP8 SP9 SP10 0' 10, • CONTRACTOR SHALL REMOVE ALL DEBRIS FROM THE Mdbmm memo ISCALE 1"=10' PROJECT SITE AS REQUIRED TO MAINTAIN A SAFE AND r ORDERLY WORK ENVIRONMENT. SP1 1 • GENERAL CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND EXISTING CONDITIONS PRIOR TO AND DURING CONSTRUCTION. SCREENED-IN EXISTING GROUND SHALL BE PROTECTED DURING I PATIO CONSTRUCTION.THE CONTRACTOR SHALL CLEAN AFTER CONSTRUCTION AND REPLACE AREAS DAMAGED AS A RESULT OF PERFORMANCE OF THE WORK. I SP7 SP12 • THE CONTRACTOR SHALL SECURE ALL OPENINGS UNDER CONSTRUCTION AT THE END OF EACH WORKING DAY. ' • ITEMS OR AREAS DAMAGED BY THE CONTRACTOR OR SUBCONTRACTORS SHALL BE REPAIRED OR REPLACED AT THE CONTRACTORS EXPENSE. • IF ANY VOIDS UNDER THE SLAB/FOUNDATION ARE DISCOVERED,CONTRACTOR WILL PUMP A I SP13 a SOIUCEMENTIWATER MIXTURE INTO THE VOID SPACE BY a 0 ACCEPTABLE INDUSTRY STANDARDS AS APPROPRIATE FOR sw L m THE SPECIFIC SITE CONDITION. - • CONTRACTOR SHOULD HAVE GENERAL LIABILITY SP6 STREET LOCATION MAP 0 w INSURANCE. p r • CONDITIONS SUCH AS INSUFFICIENT STEEL IN THE SLAB PROJECT NO.20-7965B: Z a M AND/OR OTHER STRUCTURAL CONDITIONS AND/OR WILSON RESIDENCE OWNER INFORMATION: 0 " LL SINKHOLE ACTIVITY MAY BE DISCOVERED AFTER WORK 4911 BALD CYPRESS TRL SP14 >Z�,'t LL j COMMENCES THAT MAY NOT BE VISIBLE PRIOR TO FORT PIERCE,FL 34951 RECORDED OWNER: EDWIN C WILSON& F-Q O W z COMMENCEMENT OF WORK OR EVEN DURING THE WORK. Z dj U m a (SINGLE-STORY) SARAA WILSON W>� 0 2 THESE CONDITIONS MAY MAKE LEVELING THE STRUCTURE 4911 BALD CYPRESS TRL J a W> a IMPOSSIBLE. IF SUCH CONDITIONS ARE FOUND, SP5j FORT PIERCE,FL 34951-3528 v =rn ~ CONTRACTOR WILL IMMEDIATELY HALT WORK AND INFORM THE OWNER AND THE SITE ENGINEER PARCEL ID: 1418-132-0040-000-4 • IF,DURING THE COURSE OF FOUNDATION REPAIR, EXISTING UNDERPINNINGS OR OTHER UNFORESEEN PHYSICAL ADDRESS: 4911 BALD CYPRESS TRL CONDITIONS ARE ENCOUNTERED THAT CREATE AN FORT PIERCE,FL 34951-3528 z OBSTRUCTION FOR THE CONTRACTOR,THE CONTRACTOR 0 WILL NOTIFY THE OWNER AND/OR THE SITE ENGINEER OF LEGAL DESCRIPTION: 16 34 40 S 1/2 OF SE 1/4 OF NW 114 OF SW 1/4 OF NE 1/4-LESS E 30 FT-(1.16 AC)(OR 2210-1051) SUCH UNDERPINNINGS OR OTHER CONDITIONS. SP4 FRONT J • CONTRACTOR WARRANTS THAT THE WORK AND MATERIALS WILL BE FREE FROM DEFECTS NOT INHERENT ENTRANCE PROPERTY USE: 0100 SINGLE FAMILY RESIDENCE z IN THE NATURE OF SUCH WORK AND MATERIALS AND WILL t Z H u� PERFORM AS STATED HEREIN AND THAT CONTRACTOR ! YEAR BUILT: 2006 O w V) WILL PERFORM ALL WORK EXERCISING THE STANDARD OF WATER FILTER SYSTEM 44 Q ZJL CARE NORMALLY EXERCISED BY OTHER CONTRACTORS IN z WOTHIS GEOGRAPHICAL AREA ENGAGED IN FOUNDATION P3 �V5REPAIR BY MEANS OF PILING INSTALLATION. ® LO'rTHIS PROPOSED DRAWING IS IN ACCORDANCE WITH THE WATER TANK CONTRACTOR v a ZSIXTH EDITION(2017)FLORIDA BUILDING CODE. F 0AWARD ENGINEERING INC.SHALL NOT BE RESPONSIBLE WATER wELL OFOR ANY DAMAGES OCCUR DURING THE JAY SILVER a.°d REPAIR/CONSTRUCTION WORK. HELICON FOUNDATION REPAIR SYSTEMS a a IRRIGATION CONTROL 11103 N 46TH ST,BLDG B • THE CONTRACTOR SHOWN IN THIS PLAN SHALL OBTAIN VALVES TAMPA,FL 33613 THE REQUIRED PERMIT BEFORE BEGINNING P2 CONSTRUCTION ON THIS STABILIZATION PROJECT. FAX:(813)564-1065 461 • LOCATE ALL UTILITIES INCLUDING WATER, FAX: 86 � SEWER,ELECTRICAL,TELEPHONE AND IRRIGATION LINES CBC#1255310 EITHER AROUND THE PERIMETER OR BENEATH THE GARAGE INTERIOR SLABS OF THE BUILDING. SP1 • CALL SUNSHINE PRIOR TO CONSTRUCTION. • THIS FOUNDATION STABILIZATION PLAN IS NOT i INTENDED TO MITIGATE ANY DEEP SOIL OR SINKHOLE CONDITIONS THAT MAY EXIST AT THE SITE,NOR IS IT PROPOSED UNDERPINNING PLAN DRIVEWAY LEGEND I (9 INTENDED TO REPLACE A COMPACTION GROUTING PRESSURE PIER Za'> m o w f PRESSURE PIER w/SPREADER BEAM ¢ m o PROGRAM. Z¢o o m C9�mmm PROJECT CLASSIFICATION THIS IS AN ALTERATION LEVEL 1 PROJECT AND FALLS UNDER THE WORK AREA COMPLIANCE z 0 J N N W J LL METHOD p LL �zawm ALTERATION,AS DEFINED IN CHAPTER 2 OF THE FLORIDA BUILDIG CODE-EXIS1Y1XG BUIDING,IS ANY CONSTRUCTION OR 3 ¢0Jj RENOVATION TO AN EXISTING STRUCTURE_OTHER THAN A REPAIR OR ADDITION.ALTERATIONS ARE CLASSIFIED AS LEVEL a F F tL 1,LEVEL 2 AND LEVEL 3. PROJECT DESCRIPTION: THIS PROJECT CONSISTS OF INSTALLING UNDERPINS TO PROVIDE ADDITIONAL FOUNDATION SUPPORT TO THE EXISTING FLORIDA ROOM. " DRAWN BY: 503.1 SCOPE. H.M. CHECKED BY: LEVEL 1 ALTERATIONS INCLUDE THE Rt„IJVAL AND REPLACEMENT OR 7W.E COVERING OF EXISTING MATERIALS, � H.M. ELEMENTS, EQUIPMENT,OR FIXTURES USIN^NEW MATERIALS, ELEMENTS,EQUWWNT.OR FIXTURES THAT SERVE THE I HZjREBN EERTI THA .THISINLAN%NJD- DATE: SAME PURPOSE. SPEC161¢ATIO S bN'MED BY ME 05/14/2020 503,2 APPLICATION. ORDER MY DIRECT SUPERVISION SCALE AS SHOWN LEVEL 1 ALTERATIONS SHALL COMPLY WITH T11E PROVISIONS OF CHAPTER 7. < PROJ.NO. 301.1.2 WORK AREA COMPLIANCE METHOD. ,� `1-f �j ! 20-7965B REPAIRS, ALTERATIONS, ADDITIONS, CH NC;ES IN OCCUPANCY AND RELOCATED BUILDINGS COMPLYING WITH THE "•• - SHEET APPLICABLE_REQUIREMENTS OF CHAPTER^5 THROUGH 13 OF THIS CODE SHALL BE CONSIDERED IN COMPLIANCE WI Ri HQ4/Ff1kA MP41 �1A�1.P. THE PROVISIONS OF THIS CODE. PROSES @RY/,7a OF TWO SHEETS •c- z..x we.�,n.,_. aw+�svw�.w.scsr revf-_-w f �'••y• REVISIONS BY O ASSEMBLY INCLUDES SEAT-6"X8"X1/2X12"L ANGLE IRON FxjunJation Stern Wak TOP PLATE-6"X3/4X7"L -- SP-PLANE NO HOLE 3 T05 PP-BORE+THREADED FOR GROUT Top Plate BRACKET PLATE 7"X3/4X9"L 48ottrarn Platte m BRACKET TUBE 4"SCH 120 SRL BPE CUT TO 9"L a o GUSSET-8"X1/2"X1 0 3/4"L -- BracK t _tug Z CUT DIAGONALLY FOR 2 GUSSETS w Gusset " Q W -Guns t ...... »,, n . - S;. Z to co GUIDE SLEEVE 3"SCH 40BPE CUT TO 50"L �" tees."` o =� � L ~p J WELD ON RETAINING RING 3 '112 SCH 40BPE 5/6"L W O V ..................._. ��OwZQ Z nc�F na W}J V PUSH PIPE L'_ STARTER- 2 1 2" H 40 BPE T T 48" J Q W cn } Q WELD ON SOIL PLUG •PUSH PIPE TO BE 2.875" ALL THREAD AND NUTS =(2PCS)1"X8"X6"L-ALL THREAD O.D.SCHEDULE 40 GRADE 5 STEEL PIPE o N m Q � J Z O W'n U1 Q Z W LLJ O W UNDERPINNING PIER INSTALLATION INSTRUCTIONS o o p W v¢Zaa 'F-OmF O� THE INTENT OF THE UNDERPINNING IS TO RE-SUPPORT THE FOUNDATION SLAB BY PILES BEARING ONTO THE COMPETENT MATERIAL AT DEPTH. THE �Q�° �Ir d v 0 INSTALLATION OF THE UNDERPINNING PILES WILL LIFT AND/OR SUPPORT THE STRUCTURE. THE TYPICAL SPACING BETWEEN UNDERPINS IS 6' TO 8' ON CENTER AND SHOULD NOT BE LOCATED UNDER ANY WINDOW OR OPENING UNLESS APPROVED BY THE OVERSEEING ENGINEER. ADDITIONALLY, SOME OF THE PINS' DISTANCES ARE LESS AT CORNERS, AND MORE AT GARAGES, WINDOWS, AND SLIDING DOORS. THE LOCATIONS OF THE UNDERPINS MAY REQUIRE ADJUSTMENT BY THE CONTRACTOR BASED ON SITE CONDITIONS, BUT THE OVERSEEING PROFESSIONAL ENGINEER MUST APPROVE ANY ADJUSTMENTS. UNDERPINNING BRACKETS WILL BE INSTALLED UNDER THE EXISTING SLAB AS SHOWN IN THE ABOVE DETAIL AT THE LOCATIONS SHOWN ON THE PLAN. THE PILES z WILL BE DRIVEN, HYDRAULICALLY ADVANCED, JETTED, OR DRILLED TO REACH THE RECOMMENDED DEPTH AND/OR PRESSURE. THE INTENT IN THE FIELD WILL BE c� TO INTERCEPT THE LIMESTONE/SOIL INTERFACE. THE CONTRACTOR WILL INSTALL THE PIERS TO AT A MINIMUM TO THE ANTICIPATED DEPTH OF BEDROCK OR TO w Q A DEPTH CONSIDERED SUFFICIENT TO DETERMINE THAT COMPETENT SOIL OR ROCK HAS BEEN REACHED. INDICATORS THAT SUFFICIENT DEPTH HAS BEEN Zc,." REACHED INCLUDE STRUCTURAL LIFT AND/OR PIPE ADVANCEMENT REFUSAL. MINIMUM REQUIRED PIER TERMINATION DEPTH IS 9 FEET. THE DEPTHS OF "0"O WJ LLmc%> UNDERPINNING ARE LIKELY TO VARY. TYPICAL CUTOFF PRESSURE RANGES BETWEEN 2000 AND 4000 PSI, BUT MAYBE CONSIDERABLY LESS IN LIGHT LOAD ',3 Z d AREAS, WOOD FRAME, OR COLUMNS. UPON COMPLETION OF PIER ADVANCEMENT, THE STRUCTURE LOADS WILL BE LOCKED IN BY A TOP PLATE FASTENED TO 3 m Q W Q r H F LL THE BRACKET BY TWO THREADED BOLTS AND HEX NUTS. THIS METHOD OF ATTACHMENT WILL PRESSURE HOLD THE PIER BRACKETS IN PLACE. IT IS IMPORTANT TO NOTE THAT THE OPTIMUM LEVEL TO WHICH THE STRUCTURE CAN BE LIFTED, IF RECOMMENDED, AS A RESULT OF THE UNDERPINNING oRAwNBY: .. H.M. PROCESS IS A FUNCTION OF THE STRUCTURAL CONFIGURATION AS WELL AS THE AMOUNT OF LONG-TERM AND IRREVERSIBLE STRESSES THAT HAVE v z CHECKED BY: ACCUMULATED. IT MAY NOT BE PRACTICAL_ TO ATTEMPT TO COMPLETELY RE-LEVEL THE STRUCTURE, AS EXCESSIVE COLLATERAL DA�PuIAi:E MAY RESULT. THE IHE-PjIEtYYERTIFY THAT TH19PLANAND o M• $PVCIFI�'ATION/,Vt4th�PAR�O$YME 05/13/2020 STRUCTURE IS TO BE CAREFULLY MONITORr_0 DURING ANY LIFTING PROCESS. THERE IS NO RECOMMENDATION FOR LIFTING FOP,THIS STRUCTURE . =_)WUN140MYDIRECTSUPER�IIWN. SCALE _ . AS SHOWN PROS NO. SHEET •d VES A.MOUuRRN� fil ms 2 MTOtF10`�7ddA L� OF TWO SHEETS PROJECT NOTES REVISIONS FBY • ALL CONSTRUCTION SHALL COMPLY WITH APPLICABLE PR 05/14/20 H.M. CODES AND STANDARDS,INCLUDING BUT NOT LIMITED TO ALL STATE LAWS,LOCAL ORDINANCES,UTILITY COMPANY, z AS 06/22/20 H.M. FLORIDA ACCESSIBILITY CODE FOR BUILDING CONSTRUCTION,THE OCCUPATIONAL SAFETY AND HEALTH ACT,NFPA AND THE CURRENTLY ADOPTED. SP8 SP9 SP10 0' 10, • CONTRACTOR SHALL REMOVE ALL DEBRIS FROM THE SCALE 1'=10' PROJECT SITE AS REQUIRED TO MAINTAIN A SAFE AND L�f ___j ORDERLY WORK ENVIRONMENT. S P 11 • GENERAL CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND EXISTING CONDITIONS PRIOR TO AND DURING CONSTRUCTION. SCREENED-IN • EXISTING GROUND SHALL BE PROTECTED DURING PATIO CONSTRUCTION.THE CONTRACTOR SHALL CLEAN AFTER CONSTRUCTION AND REPLACE AREAS DAMAGED AS A RESULT OF PERFORMANCE OF THE WORK. • THE CONTRACTOR SHALL SECURE ALL OPENINGS P7 UNDER CONSTRUCTION AT THE END OF EACH WORKING 0 DAY. _ • ITEMS OR AREAS DAMAGED BY THE CONTRACTOR OR SUBCONTRACTORS SHALL BE REPAIRED OR REPLACED AT THE CONTRACTORS EXPENSE. • IF ANY VOIDS UNDER THE SLAB/FOUNDATION ARE Ep DISCOVERED,CONTRACTOR WILL PUMP SP13 ¢ 0 SOIL/CEMENT/WATER MIXTURE INTO THE VOID SPACE BY - w o ACCEPTABLE INDUSTRY STANDARDS AS APPROPRIATE FOR n=re 0r m THE SPECIFIC SITE CONDITION. LD • CONTRACTOR SHOULD HAVE GENERAL LIABILITY P6 Lu STREET LOCATION MAP ¢ w INSURANCE. p - • CONDITIONS SUCH AS INSUFFICIENT STEEL IN THE SLAB PROJECT NO.20-7965B: z U AND/OR OTHER STRUCTURAL CONDITIONS AND/OR WILSON RESIDENCE OWNER INFORMATION: O M SINKHOLE ACTIVITY MAY BE DISCOVERED AFTER WORK 4911 BALD CYPRESS TRL S P 14 >Z v, COMMENCES THAT MAY NOT BE VISIBLE PRIOR TO FORT PIERCE,FL 34951 RECORDED OWNER: EDWIN C WILSON& J O w z Z(nU MLL COMMENCEMENT OF WORK OR EVEN DURING THE WORK. (SINGLE-STORY) SARAA WILSON w _1 U)o g THESE CONDITIONS MAY MAKE LEVELING THE STRUCTURE 4911 BALD CYPRESS TRL v'Lu_� IMPOSSIBLE. IF SUCH CONDITIONS ARE FOUND, SP5 FORT PIERCE,FL 34951-3528 CONTRACTOR WILL IMMEDIATELY HALT WORK AND INFORM THE OWNER AND THE SITE ENGINEER PARCEL ID: 1418-132-0040-000-4 • IF,DURING THE COURSE OF FOUNDATION REPAIR, PHYSICAL ADDRESS: 4911 BALD CYPRESS TRL EXISTING UNDERPINNINGS OR OTHER UNFORESEEN FORT PIERCE,FL 34951-3528 z CONDITIONS ARE ENCOUNTERED THAT CREATE AN QO OBST WILL NOTIFIYOTHE OWNER AOND/OR THE SITE ENGINEER OF SP4 LEGAL DESCRIPTION: OF SW 1/4 OF NE 1/4-LE SFE 01/4 N SUCH UNDERPINNINGS OR OTHER CONDITIONS. FRONT FT-(1.16 AC)(OR 2210-1051) m • CONTRACTOR WARRANTS THAT THE WORK AND MATERIALS WILL BE FREE FROM DEFECTS NOT INHERENT ENTRANCE PROPERTY USE: 0100 SINGLE FAMILY RESIDENCE J U IN THE NATURE OF SUCH WORK AND MATERIALS AND WILL z u� PERFORM AS STATED HEREIN AND THAT CONTRACTOR YEAR BUILT: 2006 O w m v WATER FILTER SYSTEM U coM WILL PERFORM ALL WORK EXERCISING THE STANDARD OF ¢z w J CARE NORMALLY EXERCISED BY OTHER CONTRACTORS IN z 0 a-ui THIS GEOGRAPHICAL AREA ENGAGED IN FOUNDATION P3 REPAIR BY MEANS OF PILING INSTALLATION. FLLI o w • THIS PROPOSED DRAWING IS IN ACCORDANCE WITH THE ® WATER TANK CONTRACTOR ¢z¢a SIXTH EDITION(2017)FLORIDA BUILDING CODE. ' O m • AWARD ENGINEERING INC.SHALL NOT BE RESPONSIBLE WATER WELL G J FOR ANY DAMAGES OCCUR DURING THE JAY SILVER a a ILL O FOR ANY DAMAGES ION WORK. ❑ HELICON FOUNDATION REPAIR SYSTEMS IRRIGATION CONTROL 11103 N 46TH ST,BLDG B • THE CONTRACTOR SHOWN IN THIS PLAN SHALL OBTAIN VALVES TAMPA,FL 33613 THE REQUIRED PERMIT BEFORE BEGINNING CONSTRUCTION ON THIS STABILIZATION PROJECT. FAX:(813)567-1465 • LOCATE ALL UTILITIES INCLUDING WATER, P2 FAX:C#1 55310 61 CBC#1255310 SEWER,ELECTRICAL,TELEPHONE AND IRRIGATION LINES EITHER AROUND THE PERIMETER OR BENEATH THE GARAGE INTERIOR SLABS OF THE BUILDING. SP1 SP12 • CALL SUNSHINE PRIOR TO CONSTRUCTION. U • THIS FOUNDATION STABILIZATION PLAN IS NOT z INTENDED TO MITIGATE ANY DEEP SOIL OR SINKHOLE CONDITIONS THAT MAY EXIST AT THE SITE,NOR IS IT DRIVEWAY LEGEND z w INTENDED TO REPLACE A COMPACTION GROUTING AS-INSTALLED UNDERPINNING PLAN PRESSUREPIER wa rno PROGRAM. PRESSURE PIER w/SPREADER BEAM w 0-r v M J N Z O N PROJECT CLASSIFICATION THIS IS AN ALTERATION LEVEL 1 PROJECT AND FALLS UNDER THE WORK AREA COMPLIANCE w J LL c m METHOD 0 Z¢ ILH- 1,ALTERATION,AS DEFINED IN CHAPTER 2 OF THE FLORIDA BUILDIG CODE-EXISITING BUIDING,IS ANY CONSTRUCTION OR 3.¢ RENOVATION TO AN EXISTING STRUCTURE OTHER THAN A REPAIR OR ADDITION.ALTERATIONS ARE CLASSIFIED AS LEVEL Q n~ LEVEL 2 AND LEVEL 3. PROJECT DESCRIPTION: THIS PROJECT CONSISTS OF INSTALLING UNDERPINS TO PROVIDE ADDITIONAL FOUNDATION SUPPORT TO THE EXISTING FLORIDA ROOM. DRAWN Bv: H.M. 503.1 SCOPE. CHECKED BY: LEVEL 1 ALTERATIONS INCLUDE THE REMOVAL AND REPLACEMENT OR THE COVERING OF EXISTING MATERIALS, I HEREBY CERTIFY THAT THIS PLAN AND H.M. ELEMENTS, EQUIPMENT,OR FIXTURES USING NEW MATERIALS, ELEMENTS, EQUIPMENT,OR FIXTURES THAT SERVE THE SPECIFICATION WAS PREPARED BY ME DATE: SAME PURPOSE. 06/22/2020 OR UNDER MY DIRECT SUPERVISION SCALE 503.2 APPLICATION. AS SHOWN LEVEL 1 ALTERATIONS SHALL COMPLY WITH THE PROVISIONS OF CHAPTER 7. PROJ.NO. 301.1.2 WORK AREA COMPLIANCE METHOD. 20-7965B REPAIRS, ALTERATIONS, ADDITIONS, CHANGES IN OCCUPANCY AND RELOCATED BUILDINGS COMPLYING WITH THE SHEET HOVHANNES A.MOURADIAN,P.E. APPLICABLE REQUIREMENTS OF CHAPTERS 5 THROUGH 13 OF THIS CODE SHALL BE CONSIDERED IN COMPLIANCE WITH PROFESSIONAL ENGINEER#78439 1 THE PROVISIONS OF THIS CODE. STATE OF FLORIDA OF ONE SHEET(S) Wilson Residence AWARD ENGINEERING, INC PINNING DATA SHEET#1 7804 FLORIDA AVE 0 4911 Bald Cypress Trail TAMPA, FL 33604 Fort Pierce, FL 34951 \ (813)238-4393 JOB #20-7965B FOREMAN: Brent PIER# 1 PIER# 2 PIER# 3 PIER# 4 PIER# 5 PIER# 6 DATE 06/11/20 DATE 06/11/20 DATE 06/11/20 DATE 06/11/20 DATE 06/11/20 DATE 06/11/20 SPREADER YES SPREADER NO SPREADER NO SPREADER YES SPREADER YES SPREADER NO LIFT 1/16" LIFT 1/16" LIFT 1/16" LIFT 1/16" LIFT 1/16" LIFT 1/16" TERMINATION 32 TERMINATION 44 TERMINATION 35 TERMINATION 43 TERMINATION 41 TERMINATION 44 DEPTH(ft) DEPTH(ft) DEPTH(ft) DEPTH(ft) DEPTH(ft) DEPTH(ft) DEPTH PRESSURE DEPTH PRESSURE DEPTH PRESSURE DEPTH PRESSURE DEPTH PRESSURE DEPTH PRESSURE 4 600 4 300 4 300 4 500 4 500 4 800 8 700 8 400 8 500 8 700 8 700 8 700 12 500 12 500 12 700 12 700 12 700 12 500 16 300 16 500 16 900 16 500 16 800 16 500 20 700 20 300 20 700 20 700 20 500 20 1000 24 700 24 800 24 400 24 900 24 1000 24 1000 28 800 28 700 28 400 28 400 28 700 28 1100 32 2200 32 600 32 700 32 400 32 1200 32 1300 36 36 600 36 2800 36 800 36 1300 36 1400 40 40 1300 40 40 1500 40 1500 40 2200 44 44 2800 44 44 3000 44 3000 44 3000 48 48 48 48 48 48 52 52 52 52 52 52 56 56 56 56 56 56 60 60 60 60 60 60 64 64 64 64 64 64 68 68 68 68 68 68 72 72 72 72 72 72 76 76 76 76 76 76 80 1 80 80 80 80 80 Wilson Residence AWARD ENGINEERING, INC PINNING DATA SHEET#2 7804 FLORIDA AVE 0 4911 Bald Cypress Trail TAMPA, FL 33604 Fort Pierce, FL 34951 \ (813)238-4393 JOB #20-7965B PIER# 7 PIER# 8 PIER# 9 PIER# 10 PIER# 11 PIER# 12 DATE 06/12/20 DATE 06/11/20 DATE 06/11/20 DATE 06/11/20 DATE 06/11/20 DATE 06/12/20 SPREADER NO SPREADER YES SPREADER YES SPREADER YES SPREADER YES SPREADER YES LIFT 1/16" LIFT 1/16" LIFT 1/16" LIFT 1/16" LIFT 1/16" LIFT 1/16" TERMINATION 35 TERMINATION 42 TERMINATION 40 TERMINATION 41 TERMINATION 35 TERMINATION 44 DEPTH(ft) DEPTH(ft) DEPTH(ft) DEPTH(ft) DEPTH(ft) DEPTH(ft) DEPTH PRESSURE DEPTH PRESSURE DEPTH PRESSURE DEPTH PRESSURE DEPTH PRESSURE DEPTH PRESSURE 4 300 4 700 4 700 4 800 4 700 4 1000 8 700 8 500 8 900 8 800 8 800 8 700 12 400 12 500 12 1000 12 800 12 800 12 800 16 500 16 1000 16 1000 16 1100 16 800 16 1000 20 700 20 1100 20 800 20 900 20 1100 20 900 24 900 24 1100 24 800 24 800 24 900 24 1200 28 1000 28 700 28 1100 28 700 28 1000 28 1300 32 1300 32 500 32 1700 32 1400 32 1200 32 700 36 3000 36 1300 36 2600 36 2600 36 3000 36 1000 40 40 1700 40 3000 40 2400 40 40 1900 44 44 3000 44 44 3000 44 44 3000 48 48 48 48 48 48 52 52 52 52 52 52 56 56 56 56 56 56 60 60 60 60 60 60 64 64 64 64 64 64 68 68 68 68 68 68 72 72 72 72 72 72 76 76 76 76 76 76 80 80 1 80 80 1 80 r 80 Wilson Residence AWARD ENGINEERING, INC PINNING DATA SHEET#3 7804 FLORIDA AVE 0 4911 Bald Cypress Trail TAMPA, FL 33604 Fort Pierce, FL 34951 \ (813)238-4393 JOB #20-7965B PIER# 13 PIER# 14 PIER# 15 PIER# 16 PIER# 17 PIER# 18 DATE 06/12/20 DATE 06/12/20 DATE DATE DATE DATE SPREADER YES SPREADER YES SPREADER SPREADER SPREADER SPREADER LI FT 1/16" LI FT 1/16" LI FT LI FT LI FT LI FT TERMINATION TERMINATION TERMINATION TERMINATION TERMINATION TERMINATION DEPTH(ft) 43 DEPTH(ft) 43 DEPTH(ft) DEPTH(ft) DEPTH(ft) DEPTH(ft) DEPTH PRESSURE DEPTH PRESSURE DEPTH PRESSURE DEPTH PRESSURE DEPTH PRESSURE DEPTH PRESSURE 4 700 4 500 4 4 4 4 8 500 8 700 8 8 8 8 12 500 12 400 12 12 12 12 16 1000 16 700 16 16 16 16 20 900 20 900 20 20 20 20 24 1100 24 600 24 24 24 24 28 1300 28 700 28 28 28 28 32 1000 32 1100 32 32 32 32 36 1200 36 900 36 36 36 36 40 2800 40 1500 40 40 40 40 44 3000 44 3000 44 44 44 44 48 48 48 48 48 48 52 52 52 52 52 52 56 56 56 56 56 56 60 60 60 60 60 60 64 64 64 64 64 64 68 68 68 68 68 68 72 72 72 72 72 72 76 76 76 76 76 76 80 1 80 F 80 1 F 80 F 80 T.R. #20-7965B ATTACHMENT " B" SITE PHOTOGRAPHS AWARD Engineering, Inc. 4911 BALD CYPRESS TRAIL T.R. #20-7965B f.. 1-4 n a P _ a 6 AWARD Engineering, Inc. 4911 BALD CYPRESS TRAIL T.R. #20-7965B ji, t a y` r ,� N�, _ d � aw a v � S'_ . a� ti '�■ R i Cry +i��''{� �a�,sS.�!,r,���• �&i��� i [' j ' !7L Q f r ti AWARD Engineering, Inc. 4911 BALD • • �'}#• _ S, try„ _ Al AWARD 1 - `�y`_` N• i� Engineering,