HomeMy WebLinkAboutEnergy CodeRt�crv�� JUH 12 7W • FORM R405-2017 permitting Department St. Lucie county FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: Lot 4 Block2Waterstone 2265 BGL Builder Name: ADAMS HOMES Street: 8313 Cristelle Court Permit Office: City, State, Zip: Fort Pierce , FL , 34951 Permit Number: Owner: Jurisdiction: 661000 Design Location: FL, ST_LUCIE_CO_INTL County: St. Lucie (Florida Climate Zone 2 ) 1. New construction or existing New (From Plans) 9. Wall Types (1996.7 sgft.) Insulation Area 2. Single family or multiple family Single-family a. Concrete Block - Int Insul, Exterior R=4.1 1397.20 ft2 b. Frame - Wood, Exterior R=13.0 391.50 ft2 3. Number of units, if multiple family 1 c. Frame - Wood, Adjacent R=13.0 208.00 ft2 4. Number of Bedrooms 4 d. WA R= ft2 5. Is this a worst case? No 10. Ceiling Types (2281.0 sqft.) Insulation Area a. Under Attic (Vented) R=30.0 2281.00 ft2 6. Conditioned floor area above grade (ft2) 2281 b. N/A R= ft2 Conditioned floor area below grade (ft2) 0 c. N/A R= ft2 11. Ducts R ft2 7. Windows(306.4 sqft.) Description Area a. Sup: Attic, Ret: Main, AH: Main 6 456.2 a. U-Factor: Dbl, U=0.33 166.06 ft2 SHGC: SHGC=0.23 b. U-Factor: Dbl, U=0.33 70.92 ft2 12. Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.21 a. Central Unit 35.0 SEER:15.50 c. U-Factor: Dbl, U=0.55 51.11 ft2 SHGC: SHGC=0.70 13. Heating systems kBtu/hr Efficiency d. U-Factor: other (see details) 18.33 ft2 a. Electric Heat Pump 34.6 HSPF:8.50 SHGC: other (see details) Area Weighted Average Overhang Depth: 5.808 ft. Area Weighted Average SHGC: 0.309 14. Hot water systems 8. Floor Types (2281.0 sgft.) Insulation Area a. Electric Cap: 40 gallons a. Slab -On -Grade Edge Insulation R=0.0 2281.00 ft2 b. Conservation features EF: 0.940 b. N/A R= ft2 None c. N/A R= ft2 15. Credits Pstat Glass/Floor Area: 0.134 Total Proposed Modified Loads: 68.82 PASS Total Baseline Loads: 72.55 I hereby certify that the plans and specifications covered by Review of the plans and Of'TUiE STq this calculation are in complian a Florida rg���. specifications covered by this __ ° O Code. calculation indicates compliance , with the Florida Energy Code. PREPARED BY: Before construction is completed DATE: mn Winn Kenmany this building will be inspected for compliance with Section 553.908 O - Y I hereby certify that this building, as designed, is in compliance Florida Statutes. with the Florida Energy Code COp WE OWNER/AGE BUILDING OFFICIAL: DATE: DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an r envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2). M 511 V2020 8:55 AM EnergyGaugeO USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 61h Edition (2017) Compliant Software Page 1 of 5 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT PROJECT Title: Building Type: Owner Name: # of Units: Builder Name: Permit Office: Jurisdiction: Family Type: New/Existing: Comment: Lot 4 Block2 Waterstone 226 Bedrooms: 4 User Conditioned Area: 2281 Total Stories: 1 1 Worst Case: No ADAMS HOMES Rotate Angle: 0 Cross Ventilation: No 661000 Whole House Fan: No Single-family New (From Plans) Address Type: Lot Information Lot # 4 Block/Subdivision: Waterston PlatBook: Street: 8313 Cristelle Court County: St. Lucie City, State, Zip: Fort Pierce, FL, 34951 CLIMATE _ / V Design Location Design Temp TMY Site 97.5 % 2.6 % Int Design Temp Heating Design Daily Temp Winter Summer Degree Days Moisture Range FL, ST_LUCIE_CO_INTL FL_VERO_BEACH_MUNI 39 90 70 75 299 58 Medium BLOCKS Number Name Area Volume 1 Blocki 2281 20529 SPACES Number Name Area Volume Kitchen Occupants Bedrooms Infil ID Finished Cooled Heated 1 Main 2281 20529 Yes 5 4 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter R-Value Area Tile Wood Carpet 1 Slab -On -Grade Edge Insulatio Main 206.2 It 0 2281 ft2 ___ 0.35 0 0.65 ROOF / V # Type Roof Gable Roof Materials Area Area Color Red Solar SA Emilt Emitt Deck Pitch Barr Absor. Tested Tested Insul. (deg) 1 Gable or Shed Composition shingles 2551 ft2 572 ft2 Medium N 0.85 N 0.85 No 0 26.6 ATTIC # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Vented 300 2281 ft2 N N CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic (Vented) Main 30 Blown 2281 ft2 0.11 Wood 5/11/2020 8:55 AM EnergyGaugeO USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 2 of 5 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT WALLS Adjacent Cavity Width Height Sheathing Framing Solar Belo Space w _ 1 S Exterior Frame - Wood Main 13 9 8 8 0 77.3 ft' 0 0.23 0.6 0 -2 S Exterior Concrete Black - Int Insul Main 4.1 38 1 10 0 380.8 k' 0 0 0.6 0 3 E Exterior Frame - Wood Main 13 3 9 10 0 37.5 ft2 0 0.23 0.6 0 _ 4 E Exterior Concrete Block - Int Insul Main 4.1 31 1 10 0 310.8 W 0 0 0.6 0 5 N Exterior Frame - Wood Main 13 6 3 8 0 50.0 ft' 0 0.23 0.6 0 -6 N Exterior Concrete Block - Int Insul Main 4.1 50 0 8 0 400.0 ft' 0 0 0.6 0 _ 7 NW Exterior Frame - Wood Main 13 3 10 10 0 38.3 ft2 0 0.23 0.6 0 _ 8 NW Exterior Concrete Block- Int Insul Main 4.1 0 5 10 0 4.2 ft2 0 0 0.6 0 -9 W Exterior Frame - Wood Main 13 18 10 10 0 188.3 ft' 0 0.23 0.6 0 10 W Exterior Concrete Block - Int Insul Main 4.1 37 8 8 0 301.3 ft2 0 0 0.6 0 11 - Garage Frame - Wood Main 13 26 0 8 0 208.0 ft2 0 0.23 0.01 0 DOORS # Ornt Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 E Insulated Main None .25 3 6 8 20 ft- 2 - Insulated Main None .25 2 8 6 8 17.8 ft2 WINDOWS Orientation shown is the entered, Proposed orientation. _ / Wall Overhang V # Ornt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 S 1 Vinyl Low-E Double Yes 0.55 0.7 N 17.8 ft2 23 ft 0 in 0 it 9 in Drapes/blinds None 2 S 2 Vinyl Low-E Double Yes 0.33 0.23 N 32.4 ft' 1 ft 0 in 0 It 10 in Drapes/blinds Exterior 5 3 E 3 Vinyl Low-E Double Yes 0.33 0.31 N 6.0 ft' 7 It 8 in 0 It 6 in None None 4 E 4 Vinyl Low-E Double Yes 0.33 0.31 N 13.3 ft' 7 It 8 in 2 It 10 in None Exterior 5 5 E 4 Vinyl Low-E Double Yes 0.33 0.21 N 32.4 ft2 1 It 0 in 0 ft 10 in Drapes/blinds Exterior 5 6 E 4 Vinyl Low-E Double Yes 0.33 ,0.21 N 38.5 ft2 1 It 0 in 2 It 0 in Drapes/blinds Exteriors 7 N 5 Vinyl Low-E Double Yes 0.55 0.7 N 15.6 ft2 23 It 0 in 0 It 9 in Drapes/blinds None 8 N 6 Vinyl Low-E Double Yes 0.33 0.23 N 9.8 ft2 1 ft 0 in 0 ft 10 in Drapes/blinds Exterior 5 9 N 6 Vinyl Low-E Double Yes 0.33 0.23 N 16.2 ft2 1 ft 0 in 0 It 10 in Drapes/blinds Exterior 5 10 NW 7 Vinyl Low-E Double Yes 0.33 0.23 N 12.5 ft2 11 ft 0 in 0 ft 4 in Drapes/blinds Exterior 5 11 W 9 Vinyl Low-E Double Yes 0.55 0.7 N 17.8 112 9 ft 4 in 0 ft 9 in Drapes/blinds None 12 W 9 Vinyl Low-E Double Yes 0.33 0.23 N 16.7 ft' 6 ft 8 in 0 ft 4 in Drapes/blinds Exterior 5 13 W 9 Vinyl Low-E Double Yes 0.33 0.23 N 30.0 ft2 9 ft 4 in 0 It 4 in Drapes/blinds Exterior 5 14 W 10 Vinyl Low-E Double Yes 0.33 0.23 N 48.6 ft' 1 ft 0 in Oft 1 O in Drapes/blinds Exterior 5 5/11/2020 8:55 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 3 of 5 �1IIT, li4/_1-'Li3.Ixdrip 6�iN4ldhil GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 476 fV 476 ft' 64 ft 8 ft 1 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .0004 2395.1 131.48 247.28 .1454 7 HEATING SYSTEM # System Type Subtype Efficiency Capacity Block Ducts 1 Electric Heat Pump/ Split HSPF:8.5 34.6 kBtu/hr 1 sys#1 COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/ Split SEER: 15.5 35 kBtu/hr 1167 cfm 0.75 1 sys#1 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.94 40 gal 62.3 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Cert # Company Name Collector Storage System Model # Collector Model # Area Volume FEF None None ft' DUCTS # —Supply— Location R-Value Area —Return Air CFM 25 CFM25 HVAC# Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool 1 Attic 6 456.2 ft Main 114.05 Default Leakage Main (Default) (Default) 1 1 5/11/2020 8:55 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 4 of 5 FORM R405-2017 INPUT SUMMARY CHECKLIST. REPORT TEMPERATURES Programablre'Thermostat: Creiling Fans: Heating Jan jY f Feb jj ]] [X] Mar r AP, [ May fX� j j Jun [XJ r ] Jul [X] [ ) Aug jX� [ ] Sep ] L J v jrX'j Dec Venting I 1 Jan L 1 r 1 Feb [Xl Mar r [ ] Jun r 111 Jul r 1 Aug r 1 Sep lxl Oct [X] Nov Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling(WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling(WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating(WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Healing(WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 MASS Mass Type Area Thickness Furniture Fraction Space Default 8lbs/s .ft. 0 ft' 0 ft 0.3 Main 5/11/2020 8:55 AM EnergyGauge® USA 6.0.02 (Rev. 1) - F1aRes2017 FBC 6th Edition (2017) Compliant Software Page 5 of 5 2017 EPL DISPLAY CARD ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX' = 95 The lower the Energy Performance Index, the more efficient the home. 1. New home or, addition 1. New (From Plans) 12. Ducts, location & insulation level a) Supply ducts R 6.0 2. Single-family or multiple -family 2. Single-family b) Return ducts R 6.0 c) AHU location Main 3. No. of units (if multiple -family) 3. 1 4. Number of bedrooms 4. 4 13. Cooling system: Capacity 35.0 a) Split system SEER 15.5 5. Is this a worst case? (yes/no) 5. No b) Single package SEER c) Ground/water source SEER/COP 6. Conditioned floor area (sq. ft.) 6. 2281 d) Room unit/PTAC EER e) Other 7. Windows, type and area a) U-factor:(weighted average) 7a. 0.367 b) Solar Heat Gain Coefficient (SHGC) 7b. 0.309 14. Heating system: Capacity 34.6 c) Area 7c. 306.4 a) Split system heat pump HSPF 8.5 b) Single package heat pump HSPF 8. Skylights c) Electric resistance COP a) U-factor:(weighted average) Be. NA d) Gas furnace, natural gas AFUE b) Solar Heat Gain Coefficient (SHGC) 8b. NA e) Gas furnace, LPG AFUE f) Other 9. Floor type, insulation level: a) Slab -on -grade (R-value) 9a. 0.0 b) Wood, raised (R-value) 9b. 15. Water heating system c) Concrete, raised (R-value) 9c. a) Electric resistance EF 0.94 b) Gas fired, natural gas EF 10. Wall type and insulation: c) Gas fired, LPG EF A. Exterior: d) Solar system with tank EF 1. Wood frame (Insulation R-value) 10A1. 13.0 e) Dedicated heat pump with tank EF 2. Masonry (Insulation R-value) 10A2. 4.1 f) Heat recovery unit HeatRec% B. Adjacent: g) Other 1. Wood frame (Insulation R-value) 10131. 13.0 2. Masonry (Insulation.R-value) 10B2. 16. HVAC credits claimed (Performance Method) 11. Ceiling type and insulation level a) Ceiling fans a) Under attic 11a. 30.0 b) Cross ventilation No b) Single assembly 11b. c) Whole house fan No c) Knee walls/skylight walls 11c. d) Multizone cooling credit d) Radiant barrier installed 11d. No e) Multizone heating credit f) Programmable thermostat Yes 'Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. I certify that this home has complied with the Florida Building Code, Energy Conservation, through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL display card will be completed based on installed code compliant features. Sz; Builder Signatures Date: Address of New Home: 8313 Cristelle Court City/FL Zip: Fort Pierce, FL 34951 5/11/2020 8:55:12 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1