HomeMy WebLinkAboutBuilding PlansPeter W. Jones, AIA AR0017858 10, 2019 Mr Jim McGuinness, Interim Building Official St. Lucie County Planning & Development Services Building & Code Regulation Division 2300 Virginia Avenue Fort Pierce, FL 34982 RE: COMMERCIAL RENOVATION 2300 INDUSTRIAL AVENUE 3 PERMIT NO. SLC-1909-0474 TEMPORARY ANIMAL SHELTER REQUEST FOR REDUCTION OF CALCULATED OCCUPANT LOAD Mr: McGuinness: The Unique nature of the use of the facility noted above is as a temporary shelter for stray or confiscated dogs and cats. Human occupancy of the structure will be limited to the management and care of the animals and will requirea very small staff. Please accept this letter as a formal request for a reduction of the calculated Occupant Load. I have been informed through the St. Lucie County Public Safety Director that the shelter operation will require no more than 15 staff members at any given time. The basis for this request falls under the 2017 Florida Building Code- Building, 6th Edition, Chapter 10 Means of Egress, Section 1004 Occupant Load, 1004.1.2 Areas without fixed seating, Exception: "Where approved by the building official, the actual number of occupants fort whom each occupied space, floor or building is, designed, although less than those determined by calculation, shall be permitted to be used in the determination of the design occupant load." you for your time and consideration in this matter. Very truly yours, irk y •,� ` .T lJr4 fr I , Peter W. Jones, AIA Cclt William DUPden, Chief Plans Examiner Daniel Retherford, Facilities Director Leslie Olsgn, Planning & Development Services Director Monica Graziani, Building & Code Regulation Manage 2300 Virginia Avenue, Fort Pierce Florida 34982 la I R all /_1 _.I It 111111-._ .KENNELS FE — — -. — — — — 9YP.) KENNELS (rYPJ AHu I-- ------- -- L. ----- ---- -- ----� F t. II-- ------------ ---- --- AHU L — — KENNELS (rYP.) J L — — ELS (TYP.) -- — -- — — — -- --— -- — -__ --- - -- - — --I II KENNELS (rYP.) L---------------------------I KENNELS (rYP.) i CLOSE OPENING, LARGE DOG KENNELS STUD RAME,2PLYWOOD BUSINESS GROUP B OR DRYWALL BOTH SIDES - 3,920 GSF/100 SF = 39.2 PERSONS 40 PERSONS TOTAL - FE - - — 7 KENNELS (TYP.)_ KENNELS (TYP.)— ORAcGE N P RT F R IT — - —' — - -- - _ -- - -- - - -- — -- STORAGE RouPNsLY -z) 3,698 GSF/300 SF = 12. PERSONS - C P A D ""-- 1_ FKENNELS(TYP) FE 13 PERSONS TO L E AF O IT N -- KENNELS(TYP.) ----— -Iu -- —J INTAKE u II d BUSINESS GROUP B 336 GSF/100 SF = 3.4 PER jj 4 PERSONS TO TAI _J CAT KENNELS F ___--- W Z BUSINESS GROUP B 716 GSF/100 SF w 7.16 PERSONS KENNELS (rYP.) F y 8 PERSONS TOTALL — — — — J _ A , KENNELS (TYP.), i L KENNELS (fYP.� - - I_ — P� FOOD ORAGE STORAGE G UP S (S-2) - 84B GSF/300 SF = 2.82 PERSONS - ALL DOG KENNELS 3 PER NS TOTAL CLOSE OPENING, BUSINESS GROUP B METAL STUD FRAME, 1,347 GSF/100 SF = 13.47 PERSONS 1 /2 PLYWOOD OR 14 PERSONS TOTAL _ _ _ _ [KENNELS OW.) DRYWALL - 64, 82' KENNELS (rYP.) �. AHu. KENNELS (_YP.) FO qHu `I L,r J C ADMINISTRATION (NON-PUBLIC USE) ' BUSINESS GROUP B I--F-I 735 GSF/100 SF = 7.35 PERSONS I\ 8 PERSONS TOTAL 1 L F -- r � I I As -Built Plan EXISTING CONCRETE PAVING N Site Detail/Parking L EMPLOYEE PARKING ACCESSIBLE PARKING SPACE PER MINIMUM REQUIREMENTS OF FBC ACCESSIBILTY CHAPTER 5, SECTION 502 PARKING SPACES FE FIRE EXTINGUISHER A"U AHU ❑� MAXIMUM TRAVEL DISTANCE Fo FAN ONLY EMERGENCY LIGHTING ® EMERGENCY EXIT -'-- EXISTING CONCRETE PAVING ADDITIONAL PARKING SPACES TO MEET MINIMUM REQUIREMENTS OF COUNTY LDC SECTION 7.06-00 OFF-STREET PARKING AND LOADING EXISTING BUILDING i J 1"=20 F ANIMAL KENNEL LOCATIONS L (TYPICAL) I I I �1 I I DENOTES REQUIRED '--' CLEARANCES (rYP.) 1 1 I 1 1 \ I I 1 3'0" 68" DO W/ r ' O ADA L ER HAR ARE ----f I !e� 3,0„ 6'8" DOOR W/ ADA L ER HARDWARE O 1 I I I i NOTE: RELOCATE FIXTURES TO MEET ADA REQUIREMENTS ADD GRAB BARS AND SUPPORT Modified Toilets I I HI/1-FADA DRINKING FOUNTAIN I I 3/32" = 1'-0" REMOVE EXISTING CLOSET WALL 1 ' (MAX.) THRESHOLD RAMP MEETING MINIMUM REQUIREMENTS OF FBC BUILDING CHAPTER 10, SECTION 1012 RAMPS AND SECTION 1014 HANDRAILS RAMP 12:1 SLOPE (MAX.) Front Entry Ramp 1W,= V-0" CODES REVIEW: THE SCOPE OF WORK CONSISTS OF THE CHANGE OF USE/OCCUPANCY OF AN EXISTING 20,140 SF BUILDING FROM GROUP — TO AN OCCUPANCY OF BUSINESS GROUP'B'. THE WORK CONSISTS OF INTERIOR IMPROVEMENTS, PLUMBING, ELECTRICAL AND MECHANICAL IMPROVEMENTS. THE EXISTING BUILDING IS CONSIDERED TO BE OF TYPE II B CONSTRUCTION. IT IS ALSO NOTED THAT THE OCCUPANCY AND USE IS CONSIDERED AS 'TEMPORARY'AS DEFINED BY 2017 FLORIDA BUILDING CODE- BUILDING, 6TH EDITION, SECTION 3103 TEMPORARY STRUCTURES. CODES REFERENCED: 2017 FLORIDA BUILDING CODE 6TH EDITION 2017 FLORIDA FIRE PREVENTION CODE 6TH EDITION: NFPA 1, NFPA 101 SYNOPSIS OF APPLICABLE CODES CHAPTERS/SECTIONS: 2017 FLORIDA BUILDING CODE 6TH EDITION: EXISTING CHAPTER 5 CLASSIFICATION OF WORK CHAPTER 9 ALTERATIONS LEVEL 3 2017 FLORIDA BUILDING CODE 6TH EDITION: BUILDING CHAPTER 2 DEFINITIONS CHAPTER 3 USE AND OCCUPANCY CLASSIFICATION SECTION 304 BUSINESS GROUP B 304.1 BUSINESS GROUP B CHAPTER 5 GENERAL BUILDING HEIGHTS AND AREAS SECTION 506 BUILDING AREA TABLE 506.2 ALLOWABLE AREA FACTOR IN SQUARE FEET TYPE II B NS 23,000 SF ALLOWED CHAPTER 6 TYPES OF CONSTRUCTION SECTION 601 GENERAL TABLE 601 FIRE -RESISTANCE RATING REQUIREMENTS FOR BUILDING ELEMENTS (HOURS) TYPE II B: '0' HOURS, ALL MEMBERS CHAPTER 10 MEANS OF EGRESS SECTION 1004 OCCUPANT LOAD 1004.1 DESIGN OCCUPANT LOAD TABLE 1004.1.2 MAXIMUM FLOOR AREA ALLOWANCES PER OCCUPANT (REFERENCE LIFE SAFETY PLAN) CALCULATED OCCUPANT LOAD- 82 PERSONS REQUESTED OCCUPANT LOAD BY ACTUAL USE: 15 PERSONS (PER FBC 1004.1.2- SEE REDUCTION LETTER ATTACHED) CHAPTER 11 FLORIDA ACCESSIBILITY CODE FOR BUILDING CONSTRUCTION CHAPTER 12 INTERIOR ENVIRONMENT SECTION 1210 SURROUNDING MATERIALS CHAPTER 13 ENERGY EFFICIENCY 2017 FLORIDA BUILDING CODE 6TH EDITION: PLUMBING CHAPTER 4 FIXTURES, FAUCETS AND FIXTURE FITTINGS SECTION 403 MINIMUM PLUMBING FACILITIES 403.1 MINIMUM NUMBER OF FIXTURES TABLE 403.1 MINIMUM NUMBER OF REQUIRED PLUMBING FIXTURES (REFERENCE SECTIONS 403.2, 403.4 AND 403.4.1) BASED ON OCCUPANT LOAD OF 121 PERSONS 41 MALE 41 FEMALE WC/URINAL LAV DF MOP MALE: REQUIRED: 1 1 PROVIDED: 1 1 FEMALE: REQUIRED: 1 1 PROVIDED: 1 1 ALL: REQUIRED: t 1 PROVIDED: 1 1 2017 FLORIDA BUILDING CODE 6TH EDITION: ACCESSIBILITY NFPA 1 FIRE CODE CHAPTER 1 ADMINISTRATION SECTION 1.14 PLAN REVIEW CHAPTER 6 CLASSIFICATION OF OCCUPANCY SECTION 6.1 CLASSIFICATION OF OCCUPANCY 6.1.11 BUSINESS CHAPTER 10 GENERAL SAFETY REQUIREMENTS CHAPTER 14 MEANS OF EGRESS Code Summary NOTES: 1. ALL DIMENSIONS ARE ABOVE FINISHED FLOOR. 2. GRAB BARS SHALL HAVE AN OUTSIDE DIAMETER OF 1 1/2". 3. PROVIDE 1 1/2" CLEARANCE BETWEEN RAIL AND WALL. 4. PROVIDE GRAB BAR BACKING SUCH THAT BARS SUPPORT PULL STRENGTH OF NOT LESS THAN 250 LBS. 5. FINISHES PER FBC:BUILDING CHAPTER 12 INTERIOR ENVIRONMENT A. FLOORS IN BATHROOMS, KITCHEN AND PUBLIC AREAS TO BE FINISHED WITH NON -SLIP DURABLE NON -ABSORBENT COATING. B. PERIMETER WALLS AT BLOCK AREA 3 FT. FROM FLOOR WILL BE COATED WITH NON -ABSORBENT FINISH, WASHABLE IN BATHROOMS AREAS. 18" 42" MIN. " 3 "MIN. 54"MIN. N QlRAI11U 19" Milt. TOILET PAPER 0"X 48'� 60"X 60" L . LEAR CLEAR 2 " MIN. 1 "MIN. M TRANSFER SIDE ADA Toilet 1/4" = T-0 St. Lucie County BOCC 2300 Virginia Avenue Fort Pierce, Florida 34982 T: 772.462.1100 General Contractor: Keyplan: 1 ® = Area of Improvements Issues: No.: Date: Description: 01 10.10.2019 AS -BUILT 2700 Industrial Ave 3 Temporary Animal Facility St. Lucie County, Florida Drawing Title: AS -BUILT PLAN Drawn: PWJ Issue Date: 10.10.2019 Checked: Scale: Project No.: Sheet No.: AB-1 THE ATTACHED PLANS HAVE BEEN DESIGNED FOR AND ARE IN COMPLIANCE WITH THE 6TH EDITIONS OF THE FLORIDA BUILDING CODE AND FLORIDA FIRE PREVENTION CODE. DESIGN IS SITE SPECIFIC AND NOT VALID WrrHOUT THE AUTHORIZED SIGNATURE AND SEAL OF A REGISTERED ARCHITECT. THESE NOTES ARE PART OF THE CONSTRUCTION DOCUMENTS. DO NOT SCALE THESE DRAWINGS, USE FIGURED DIMENSIONS ONLY. IF A DISCREPANCY OCCURS, CONTACT THE ARCHITECT FOR CLARIFICATIONS. I i t7 111t T�y • 11 -- 10.10.2019 Peter W. Jones Date AR0017858 �`1L �'- � o 50' 011 -00 Aoc ENIIWALL ELEVATION OPPOSITE ENDWALL SIMILAR o �.. N N '.. 171-0" 9' O" `1r_ 1 15r-8" 6. 1V-1 -4" •-1" -11" r-4" EAST SIDEWALL i REVISIONS BY A" nnnnrtw. z w-v _ M U Li w W ��c> JJJ W— Im J =.* E wa0, q 5-0 n m N o UJ DR AWN RAP CHECKED PW DATE 08 11 17 JOB', NO. SHEET A-1 OF TWO - L L — — — — — Fa — — _ — — ® 102' VE EXISTIN SHELVING/SCAFFOLDING - L--i r-------------- DOG KENNELS O I BUSINESS GROUP B 3,920 GSF/100 SF = 39.2 PERSONS 40 PERSONS TOTAL ' AHU FA III ! ! CLOSE OPENING, METAL i STUD FRAME, 1/2 PLYWOOD OR DRYWALL BOTH SIDES i DOG ENNELS BUSINE GROUP B 3,6 8 GSF/100 SF 36.98 PERSONS NO PA OF HIS — — — — 37 PERSO S TOTAL OP OR I I 84 = I I CAT KE NELS BUSINESS OUPB 1, 2 GSF/100 SF = 17.42 PERSONS BUSINESS aouP e 18 PERSO TOTAL CLOSE OPENING, 1,696 GSF/100 SF = 16.96 PERSONS METAL STUD FRAME, 17 PERSONS TOTAL 1/2 PLYWOOD OA DRYWALL I!I 64 I 82 AHU FO nHw FA Life UPGRADE ACCESSIBLE AHU - TOILETS- SEE PLAN \--- FE a"u DETAIL THIS SHEET 'Lr� FIRE EXTINGUISHER AHU MAXIMUM ADMINISTRATION f TRAVEL DISTANCE AFAi AHU/FRESH AIR INESS GROUP 8 866 GSF/100 SF = 8.66 PERSO S 9 PERSONS TOTAL _�Ff _ _ EMERGENCY LIGHTING Fo FAN ONLY r ® EMERGENCY EXIT ADD FRONT ENTRY ACCESSIBLE RAMP- SEE PLAN DETAIL THIS SHEET -------------- - 3/32" = 1'-0" I ! ! I Y I�I DENOTES REQUIRED --- ^ CLEARANCES (TYP.) ` ---- L , I I , 310" 618,100 W/ O ADA L ER HAR ARE - 3,0,, 6'8" DOOR W/ ADA L ER HARDWARE REMOVE EXISTING CLOSET WALL NOTE. RELOCATE I ! I FIXTURES TO MEET ADA k — — REQUIREMENTS ADD I < ------ I i — GRAB BARS AND SUPPORT HI/LO�ADA r I, DRINKING 1 FOUNTAIN L --- Modified Toilets 1/4"=1'-0" 1 " (MAX.) T RESHOLD 5'X5' LANDING 11 ACCESSIBLE ROUTE TO ACCESSIBLE 2O PARKING SPACE BOTH MEETING MINIMUM REQUIREMENTS OF FBC _J ACCESSIBILTY CHAPTERS 4 AND 5 r N 5'X5' LANDING Front Entry Ramp 1/4"=1'-0" CODES REVIEW: THE SCOPE OF WORK CONSISTS OF THE CHANGE OF USE/OCCUPANCY OF AN EXISTING 20,140 SF BUILDING FROM GROUP _ TO AN OCCUPANCY OF BUSINESS GROUP'B'. THE WORK CONSISTS OF INTERIOR IMPROVEMENTS, PLUMBING, ELECTRICAL AND MECHANICAL IMPROVEMENTS. THE EXISTING BUILDING IS CONSIDERED TO BE OF TYPE 11 B CONSTRUCTION. IT IS ALSO NOTED THAT THE OCCUPANCY AND USE IS CONSIDERED AS 'TEMPORARY' AS DEFINED BY 2017 FLORIDA BUILDING CODE- BUILDING, 6TH EDITION, SECTION 3103 TEMPORARY STRUCTURES. CODES REFERENCED: 2017 FLORIDA BUILDING CODE 6TH EDITION 2017 FLORIDA FIRE PREVENTION CODE 6TH EDITION: NFPA 1, NFPA 101 SYNOPSIS OF APPLICABLE CODES CHAPTERS/SECTIONS: 2017 FLORIDA BUILDING CODE 6TH EDITION: EXISTING CHAPTER 5 CLASSIFICATION OF WORK CHAPTER 9ALTERATIONS LEVEL 3 2017 FLORIDA BUILDING CODE 6TH EDITION: BUILDING CHAPTER 2 DEFINITIONS CHAPTER 3 USE AND OCCUPANCY CLASSIFICATION SECTION 304 BUSINESS GROUP B 304.1 BUSINESS GROUP B CHAPTER 5 GENERAL BUILDING HEIGHTS AND AREAS SECTION 506 BUILDING AREA TABLE 506.2 ALLOWABLE AREA FACTOR IN SQUARE FEET TYPE 11 B INS 23,000 SF ALLOWED CHAPTER 6 TYPES OF CONSTRUCTION SECTION 601 GENERAL TABLE 601 FIRE -RESISTANCE RATING REQUIREMENTS FOR BUILDING ELEMENTS HOURS TYPE II B: '0' HOURS, ALL MEMBERS CHAPTER 10'MEANS OF EGRESS SECTION 1004 OCCUPANT LOAD 1004.1 DESIGN OCCUPANT LOAD TABLE 1004.1.2 MAXIMUM FLOOR AREA ALLOWANCES PER OCCUPANT (REFERENCE LIFE SAFETY PLAN) TOTAL OCCUPANTS 147PERSONS CHAPTER'11 FLORIDA ACCESSIBILITY CODE FOR BUILDING CONSTRUCTION CHAPTER 12 INTERIOR ENVIRONMENT SECTION 1210 SURROUNDING MATERIALS CHAPTER 13' ENERGY EFFICIENCY 2017 FLORIDA BUILDING CODE 6TH EDITION: PLUMBING CHAPTER 4 FIXTURES, FAUCETS AND FIXTURE FITTINGS SECTION 403 MINIMUM PLUMBING FACILITIES 403.1 MINIMUM NUMBER OF FIXTURES TABLE 403.1 MINIMUM NUMBER OF REQUIRED PLUMBING FIXTURES (REFERENCE SECTIONS 403.2, 403.4 AND 403.4.1) BASED ON OCCUPANT LOAD OF 147 PERSONS 74 MALE 74 FEMALE WC/URINAL LAV DF MOP MALE: REQUIRED: 1 1 PROVIDED: 1 1 FEMALE`. REQUIRED: 1 1 PROVIDED: 1 1 ALL: REQUIRED: 1 1 PROVIDED: 1 2017 FLORIDA BUILDING CODE 6TH EDITION: ACCESSIB11TY NFPA 1 FIRE CODE CHAPTER 1 ADMINISTRATION SECTION 1.14 PLAN REVIEW CHAPTER 6 CLASSIFICATION OF OCCUPANCY SECTION 6.1 CLASSIFICATION OF OCCUPANCY 6.1.11 BUSINESS CHAPTER 10 GENERAL SAFETY REQUIREMENTS CHAPTER 14 MEANS OF EGRESS CHAPTER 20 OCCUPANCY FIRE SAFETY SECTION 20.13 BUSINESS OCCUPANCIES Code Summary NOTES: 1. ALL DIMENSIONS ARE ABOVE FINISHED FLOOR. 2. GRAB BARS SHALL HAVE AN OUTSIDE DIAMETER OF 1 1/2". 3. PROVIDE 1 1/2" CLEARANCE BETWEEN RAIL AND WALL. 4. PROVIDE GRAB BAR BACKING SUCH THAT BARS SUPPORT PULL STRENGTH OF NOT LESS THAN 250 LES. 5. FINISHES PER FBC:BUILDING CHAPTER 12 INTERIOR ENVIRONMENT A. FLOORS IN BATHROOMS, KITCHEN AND PUBLIC AREAS TO BE FINISHED WITH NON -SLIP DURABLE NON -ABSORBENT COATING. B. PERIMETER WALLS AT BLOCK AREA 3 FT. FROM FLOOR WILL BE COATED WITH NON -ABSORBENT FINISH, WASHABLE IN BATHROOMS AREAS. 18" 42" MIN. 3 "MIN. 54" MIN. ' 12" 42"MIN. ¢"�RADIU Ml TOILET PAPER CIr CN $0„X 4fly 60"X 601,L LEAK CLEAR r 24" MIN. 12"IMIN. TRANSFER SIDE 1 ADA Toilet 1/4" = T-0" OCCUPANCY AND USE 1S CONSIDERED AS 'TEMPORARY' AS DEFINED BY 2017 FLORIDA BUILDING CODE- BUILDING, 6TH EDITION, SECTION M63 TEMPORARY STRUCTURES. St. Lucie County BOCC 2300 Virginia Avenue Fort Pierce; Florida 34982 T: 772.462.1100 General Contractor: I Keyplan: = Area of Improvements Issues: No.: Date: Description: A 09.18.2019 PERMIT DRAFT B 09.20,2019 PERMIT DRAFT I, 01 09.23.2019 PERMIT - 01=rr- TI/PD aor y,k Lutz ST. Lucie County, Permitting Project: FILE COP 2700 Industrial Ave 3 Temporary Animal Facility St. Lucie County, Florida REVIEWED FOR If CODE CI ST. LU COUNT, , BOCC Drawing Title: DETAIL EXISTING FLOOR PLAN Drawn: Issue Date: PWJ 09.23,2019 Checked: Scale: Project No.: Sheet No.: !! SK-1! IN COMPLIANCE WITH THE 6TH EDITIONS OF THE FWHIDA BUILDING CODE AND FLORIDA FIRE PREVENTION CODE. DESIGN IS SITE SPECIFIC AND NOT VALID WITHOUT THE AUTHORIZED SIGNATURE AND SEAL OF A REGISTERED ARCHITECT. THESE NOTES ARE PART OF THE CONSTRUCTION DOCUMENTS. DO NOT SCALE THESE DRAWINGS, USE FIGURED DIMENSIONS ONLY. IF A DISCREPANCY OCCURS, CONTACT THE ARCHITECT FOR CLARIFICATIONS. - +.T �'..f.7 P"Sr (iif 09.23.2019 Peter W. Jones Date Al ]17858