Loading...
HomeMy WebLinkAboutCompaction TestANDERSEN ANDRE CONSULTING ENGINEERS; INC. 834 SW Swan Avenue Port St. Lucie, Florida 34983 Phone: 772-807-9191 Fax: 772-807-9192 www.aaceinc.com FIELD DENSITY TEST REPORT PROJECT: FPL Solar Interstate Education/Operation Center FILE NO: 20-148 St. Lucie County, FIL REPORT NO: 15 REPORTED TO: Curington Contracting CC: DATE OF TEST(S): 06/25/2020 PAGE NO.: 1 OF 1 TEST NO, Building Foundations, Column Footings MDR MOISTURE DRY DENSITY PERCENT DEPTH NO. CONTENT (%) (PCF) COMPACTION LOCATION 1 Gridline A-2 3065 8.8 107.2 96 0 to -12" F 2 Gridline A-3 3065 8.2 106.5 95 0 to -12" F 3 Gridline A-4 3065 9.0 107.4 96 0 to -12" F 4 Gridline A-5 3065 8.3 107.0 96 0 to -12" F 5 Gridline G-2 3065. 8.7 106.7 96 0 to -12" F 6 Gridline G-3 3065 9.2 107.3 96 0 to -12" F 7 Gridline G-4 3065 8.9 107.9 97 0 to -12" F 8 Gridline G-5 3065 9.5 107.5 96 0 to -12" F * DENOTES IN-PLACE DENSITY TEST DOES NOT MEET MINIMUM COMPACTION REQUIREMENT OF 95 PERCENT. ** RETEST INDICATED DENSITY MEETS OR EXCEEDS MIN. DENSITY REQUIREMENTS PER SPECIFICATIONS FIELD TEST: r` ASTM D-2937 , ASTM D-2922 r, - ASTM D-2167 ASTM D-1556 TECHNICIAN: SM REMARKS: LABORATORY MOISTURE -DENSITY RELATIONSHIP F = SOIL DIRECTLY BELOW FOOTING FS = FLOOR SLAB SUBGRADE OPTIMUM ASTM MAX. GA = SOIL IN GENERAL COMPACTED AREA PAV = SOIL BELOW STABILIZED SECTION MDR NO. MOISTURE TEST METHOD DENSITY PSSG = STABILIZED SUBGRADE PB = PAVEMENT BASE CONTENT RS = ROADWAY NSSG = NON STABILIZED SUBGRADE 3065 D1557 111.7 PCF 10.1% SBP= SOIL BELOW PAVEMENT TOP = TOP OF PIPE BOP = BOTTOM OF PIPE BOS = BOTTOM OF STRUCTURE OTHER: ..vl{IIIb._ rG. Andersen, P.E. 4 ela. RtWN(5i9ffi AS A MUTUAL PROTECTION TO CLIENTS, THE PUBLIC AND OURSELVES, ALL REPORTS ARE SUBMITTED AS THE COMPUWIIL PROPERTY OFCLIENTS AND Al1TCgRWATION FOR PUBLICATION OF STATEMENTS, CONCLUSIONS OR EXTRACTS FROM OR REGARDING OUR REPORTS IS.RE \1fD PEND&AQ�A•U� prEN APPAtt ,L -ft a�f, �/4�CV1' 00 0 Lo NAt- ANDERSEN ANDRE CONSULTING ENGINEERS, INC. 834 SW Swan Avenue Port St. Lucie, Florida 34983 Phone: 772-807-9191 Fax: 772-807-9192 www.aaceinc.com FIELD DENSITY TEST REPORT PROJECT: FPL Solar Interstate Education/Operation Center FILE NO: 20-148 St. Lucie County, FL REPORT NO: 16 REPORTED TO: Curington Contracting CC: DATE OF TEST(S): 06/25/2020 PAGE NO.: 1 OF 1 TEST NO. Elevator Pit Footing MDR NO. MOISTURE CONTENT (%) DENSITY (PCF) PERCENT COMPACTION DEPTH LOCATION 1 Center of Pit Footing 3065 9.5 108.1 97 0 to -12° F * DENOTES IN-PLACE DENSITY TEST DOES NOT MEET MINIMUM COMPACTION REQUIREMENT OF 95 PERCENT. ** RETEST INDICATED DENSITY MEETS OR EXCEEDS MIN. DENSITY REQUIREMENTS PER SPECIFICATIONS FIELD TEST: F ASTM D-2937 Cv ASTM D-2922 r ASTM D-2167 (,' ASTM D-1556 TECHNICIAN: SM REMARKS: LABORATORY MOISTURE -DENSITY RELATIONSHIP F = SOIL DIRECTLY BELOW FOOTING FS = FLOOR SLAB SUBGRADE ASTM MAX. OPTIMUM GA = SOIL IN GENERAL COMPACTED AREA PAV = SOIL BELOW STABILIZED SECTION MDR NO. TEST METHOD DENSITY MOISTURE PSSG = STABILIZED SUBGRADE PB = PAVEMENT BASE CONTENT RS = ROADWAY NSSG = NON STABILIZED SUBGRADE 3065 D1557 111.7 PCF 10.1 % SBP = SOIL BELOW PAVEMENT TOP = TOP OF PIPE BOP = BOTTOM OF PIPE BOS = BOTTOM OF STRUCTURE OTHER: ���-'��t •NsF• O�/ori —Pe r 4^. Andersen, M. }Reg. No. 579[6/ AS A MUTUAL PROTECTION TO CLIENTS, THE PUBLIC AND OURSELVES, ALL REPORTS ARE SUBMITTED AS THE CONFIDENI'� � }ARTY srC�LrNTSAND AUTFj{iRS TI4 FOR PUBLICATION OF STATEMENTS, CONCLUSIONS OR EXTRACTS FROM OR REGARDING OUR REPORTS IS RESEF�iCP 13VG.IR WRITTEN APPRVN* ®�