HomeMy WebLinkAboutIncident ReportDate: 5/18/2020 Owner: Stacy Kastner Address: 2303 Canoe Creek Ln. Ft, Pierce Tenant: N/A Type of Incident: Fire Planning and Development Services Building and Code Regulation Division 2300 Virginia Avenue, Fort Pierce FL 34982 Phone: (772) 462-1553 Fax: (772) 462-6443 Time: 8:17 AM The above premises have been inspected by: David Johnson The following items must be done to bring the building up to code: Plans required: Yes Electrical: Yes Plumbing: No Structural: Yes Mechanical: Yes Other: Mechanical ducts and Air Handler replaced without permit Comments: Fire originated in fireplace. Wood framed walls around fireplace must be replaced along with fire box and chimney. Damaged trusses will need to be replaced or repaired. All trusses not replaced will need to be certified by structural engineer that they have not been compromised and are structurally sound. R&R all damaged drywall in room in front of fireplace and in garage area. Electric wiring damaged will need to be R&R. Emergency repairs to get home re -energized that was already done requires a permit to be pulled ASAP. Building Permit needed: X Yes No Signed: David Johnson Title: Chief Building Inspector 01/19-gs