Loading...
HomeMy WebLinkAboutBuilding PermitAll APPLICABLE INFO MUST BE COMPLETED FOR APPLICATION TO BE ACCEPTED Date: 06/29/2020 Permit Number: gv. Um 0 Building Permit Application Planning and Development Services Building and Code Regulation Division Commercial x Residential 2300 Virginia Avenue, Fort Pierce FL 34982 Phone: (772) 462-1553 Fax: (772) 462-1578 PERMIT APPLICATION FOR: Mechanical PROPOSED IMPROVEMENT LOCATION: Address: 1555 SE Tiffany Club Place PropertyTax ID #: 3414-501-3503-000-5 Site Plan Name: Project Name: Reserve at Port St Lucie DETAILED DESCRIPTION OF WORK: Exact AC change out - Replace existing AC unit with a 2 ton Tempstar 14 Seer R410 Air Handler - FEM4P2400 5 KW Heater Condenser - NXA424GKC New Electrical Meter Second Electrical Meter I CONSTRUCTION INFORMATION: Additional work to be performed under this permit– check all that apply: _Mechanical _ Gas Tank _ Gas Piping Electric _ Plumbing _Sprinklers Total Sq. Ft of Construction: _ Cost of Construction: $ 2,200 Lot No. Block No. _Shutters —Windows/Doors _Pond _Generator _Roof Pitch Sq. Ft. of First Floor: Utilities: _Sewer _Septic Building Height: OWNER/LESSEE: .,_ ;, , ,, , I CONTRACTOR: Name Tiffany Park Partners LTD Address: 3475 Piedmont Rd NE Ste 1640 City: Atlanta State: Zip Code: 30305 Fax: Phone No. E -Mail: Fill in fee simple Title Holder on next page ( if different from the Owner listed above) Name: Oscar A Calzadilla Company: Unico Air Conditioning Co Address: 1711 Sunset Isle Rd City: Ft Pierce State: FI Zip Code: 34949 Fax: 772-674-7525 Phone No 305-528-1392 E -Mail marty@unicohvac.com State or County License CAC1814920 It value of construction is 2500 or more, a RECORDED Notice of Commencement is required. If value of HAVC is $7,500 or more, a RECORDED Notice of Commencement is required. SUPPLEMENTAL CONSTRUCTION LIEN LAW INFORMATION: DESIGNER/ENGINEER: _ Not Applicable Name: MORTGAGE COMPANY: _ Not Applicable Name: Address: Address: City: State: Zip: Phone City: State: Zip: Phone: FEE SIMPLE TITLEHOLDER: _ Not Applicable Name: BONDING COMPANY: _Not Applicable Name: Address: Address: City: City: Zip: Phone: Zip: Phone: OWNER/ CONTRACTOR AFFIDVIT: Application is hereby made to obtain a permit to do the work and installation as indicated. I certify that no work or installation has commenced prior to the issuance of a permit. St. Lucie County makes no representation that is granting a permit will authorize thegermit holder to build the subject structure which is in conflict with any applicable Home Owners Association rules, bylaws or an covenants that may restrict or prohibit such structure. Please consult with your Home Owners Association and review your deed for any restrictions which may apply. In consideration of the granting of this requested permit, I do hereby agree that I will, in all respects, perform the work in accordance with the approved plans, the Florida Building Codes and St. Lucie County Amendments. The following building permit applications are exempt from undergoing a full concurrency review: room additions, accessory structures, swimming pools, fences, walls, signs, screen rooms and accessory uses to another non-residential use WARNING TO OWNER: Your failure to Record a Notice of Commencement may result in paying twice for improvements to your property. A Notice of Commencement mu5J4eTesQrded in the public records of St. Lucie County and posted on the jobsite before the first inspec' K. If yQUIDILrid to obtain financing, consult with lender or an attorney before commencing work or rec in r Not f Commencement. G-ran4-- T Cardane. Signature of Owner/ Lessee/Contractor as Agent for Owner Signatu of Contra r/Li e e Holder STATE OF FLORIDA STATE OF FL COUNTY OF Mamn COUNTY OF Mahn Sworn to (or affirmed) and subscribed before me of Sworn to (or affirmed) and subscribed before me of X Physical Presence or Online Notarization X Physical Presence or_ Online Notarization _ chis N day of June 2020 by this 29 day of June 2020 by Grant T Gardone Oa®rA Galzedille Name of person making statement. Name of person making statement. Personally Known x OR Produced Identification Personally Known X OR Produced Identification Type of Identification Type of Identification Produced Produced Ignature of Notary li Stbt 'yff'Flor'�{ fl MMISSION # GG 19132 - .. ignature of Nota q�9aAM. AGUIRRE 61Y C m+' .i;< ,,,EXQIRES: March 9, 20'11 Commission NO. GG181327 q£ Notary Public Underair v..a .. ' : f' <'-, A1Y COMMISSION # C J 13132T tsC mmission No. GG19t EXPII�6B3�r Pu Bondad Thnl NotaryPuNk UmtemrY.a� REVIEWS FRONT ZONING SUPERVISOR PLANS VEGETATION SEA TURTLE MANGROVE COUNTER REVIEW REVIEW REVIEW REVIEW REVIEW REVIEW DATE RECEIVED DATE COMPLETED Rev. S/b/ZU Unico Air Conditioning Company 25 SW Cabana Point Circle Stuart, FL 34994 Phone; (772)678-6676 Fax: (772)647-7525 Contract Billing Address Document Number 51007510338 Unico Air Conditioning Company Date 06/17/2020 25 SW Cabana Point Circle Stuart, FL 34994 Shipping Address: Grant T Cardona Reserve at PSL 1555 SE Tiffany Club PI Port St Lucie ,FI 772-421-0822 Terms of payment: Net 15 Days Term of delivery: ZOR(FOB Origin) Equipment ready for pick up at HD Supply Item Material/Description Quantity Unit Price Amount 1 Install Indoor/outdoor AC Unit 1 $2,200.00 $2,200.00 Int. Article No. 25937855 2 ton Tempstor 14 Seer R410 Signature:y ron+ T CQ rd Un e Certificate of Product Ratin AHRI Certified Reference Number: 9487261 Date : 06-17-2019 Model Status : Active AHRI Type: RCU-A-CR Series: 14 SEER N SERIES R410A AC Outdoor Unit Brand Name: TEMPSTAR Outdoor Unit Model Number (Condenser or Single Package) NXA424(A,G)KC" Indoor Unit Model Number (Evaporator and/or Air Handier) FEM4P24"AL Region : Southeast and North (AL, AR, DC, DE, FL, GA, HI, KY, LA, MD, MS, NC, OK, SC. TN, TX, VA, AK, CO, CT, ID, IL, IA, IN, KS, MA, ME, MI, MN, MO, MT, ND, NE. NH, NJ, NY, OH, OR, PA, RI. SD, UT. VT, WA, WV, WI, WY, U.S. Territories) Region Note: Central air conditioners manufactured prior to January 1, 2015 are eligible to be installed in all regions until June 30, 2016. Beginning July 1. 2016 central air conditioners can only be installed in region(s) for which they meet the regional efficiency requirement. The manufacturer of this TEMPSTAR product is responsible for the rating of this system combination. Rated as follows in accordance with the latest edition of ANSI/AHRI 2101240 with Addenda 1 and 2, Performance Rating of Unitary Air -Conditioning & AirSouroe Heat Pump Equipment and subject to rating accuracy by AHRI-sponsored, independent, third parry testing: Cooling Capacity (A2) - Single or High Stage (95F). btuh : 22800 SEER: 14.00 EER (A2) - Single or High Stage (95F) : 11.50 t"Active" Model Status are those that an AHRI Certification Program Participant is currently producing AND selling or offering for sale: OR new models that are being marketed but are not yet being produced "Production Stopped' Model Status are those that an AHRI Certification Program Participant is no longer producing BUT is soil selling or offering for sale. Ratings_ that are acoomoanied by WAS indicate an involuntary re -rate. The new published retina is shown along with the Drevious h e. WAS) ratino. DISCLAIMER AHRI does not endorse the producl(s) listed on this Certificate and makes no representations, warranties or guarantees as to, and assumes no responsibility for, the products) listed on this Certificate. AHRI expressly disclaims all liability for damages of any kind arising out of the use or performance of the produchs), or the unauthorized alteration of data listed on this Certificate. Certified ratings are valid only for models and configurations listed in the directory at www.ahridirectory.org. TERMS AND CONDITIONS This Certificate and Its contents are proprietary products of AHRI. This Certificate shall only be used for individual, personal and confidential reference purposes. The contents of this Certificate may not, In whole or in part, be reproduced; copied; disseminated; entered Into a computer database; or otherwise utilized, in any form or manner or by any means, except for the user's Individual, personal and confidential reference. AIR-CONDITIONING. HEATING, CERTIFICATE VERIFICATION & REFRIOERATION INSTITUTE The information for the model cited on this certificate can be verified at www.ahridirectory.org, click on "Verify Certificate" link »e„rake lire beim,° and enter the AHRI Certified Reference Number and the date on which the certificate was issued, which is listed above, and the Certificate No., which is listed at bottom right. ©2019Air-Conditioning, Heating, and Refrigeration Institute CERTIFICATE NO.: a2o52a7e24G255o52