Loading...
HomeMy WebLinkAboutbuilding permitAll APPLICABLE INFO MUST BE COMPLETED FOR APPLICATION TO BE ACCEPTED i�7 . Date: Permit Number: Building Permit Application Planning and Development Services Building and Code Regulation Division 2300 Virginia Avenue, Fort Pierce FL 34982 / Phone: (772) 462-1553 Fax: (772) 462-1578 Commercial Residential Site Plan Name:. Block No. Project Name: Additional work to be performed under this permit— check all that apply: _Mechanical +�GasTank /Gas Piping _Shutters —Windows/Doors _ Electric _ Plumbing _ Sprinklers _ Generator _ Roof Pitch Total Sq. Ft of Construction: a Sq. Ft. of First Floor: Cost of Construction: $! lip a �il, o Utilities: —Sewer _Septic Building Height: Name T- r Address I Win _ City: I State: Zip Code: L. ? Fax: Phone No. .E-Mail: Fill in fee simple Title Holder on next page ( if different from the Owner listed above) Licastri Company: AmeriGas Address:3301 Oleander Avenue City: Fort Pierce State: FL Zip Code: 34982 Fax: 772-465-8448 Phone E-MailAmeriGas-7262@amerigas.com State or County License02707/28579 If value of construction is S2500 or more. a RECORDED Notice of Commencement is required If value of HVAC is $7,500 or more, a RECORDED Notice of Commencement is required. Name: Address: City: State: Zip: Phone FEE SIMPLE TITLE HOLDER: _ Not Applicable Name: Address: City: Zip: Phone: MORTGAGE COMPANY: _ Not Applicable Address: City: State: Zip: Phone: BONDING COMPANY: _Not Applicable Address: City:_ Zip: OWNER/ CONTRACTOR AFFIDVIT: Application is hereby made to obtain a permit to do the work and installation as indicates. I certify that no work or installation has commenced prior to the issuance of a permit. St. Lucie County makes no representation that is granting a permit will authorize the permit holder to build the subject structure which is in conflict with any applicable Home Owners Association rules, bylaws or and covenants that may restrict or prohibit such structure. Please consult with your Home Owners Association and review your deed for any restrictions which may apply. In consideration of the granting of this requested permit, I do hereby agree that I will, in all respects, perform the work in accordance with the approved plans, the Florida Building Codes and St. Lucie County Amendments. The following building permit applications are exempt from undergoing full concurrency review: room additions, accessory structures, swimming pools, fences, walls, signs, screen rooms and accessory uses to another non-residential use WARNING TO OWNER: Your failure to Record a Notice of Commencement may result in your paying twice for i ov nts ta-yai�r property. A Notice of Commencem must a recorded and posted on the jobsite b ore the fir t inspection. If you intend to obtain financi consult !th-lender or an attorney before Signa ure of Ow er/ Lessee/Contractor as Agent for Owner Sign ture of C ntractor/License Holder STATE Q F RIDA STATE LORIDA COUNTY O COUNTY OF 8� The forgoing instrument was acknowledged before me The forgoing instrument was acknowledged before me this "6 day oT�2 '0� by thisaS day of -Vt SZ 2L=bY r Name of person making statement X Name of person making statement Personally Known >� OR Produced Identification Personally Known OR Produced Identification . Type of Identificatbril"I'll Type of Identification Produced - 4yrk Notary Public State of Florida Pro blic State of Florida ngef�M-Boore My Commission GG 190609 Angela M Boore My Comrlesion GG 190609 Expires 02/27/2022 Expires 021Yj/2022 (Signature of Notary Public- State of Florida) re o Notary Public- State of Florida-) Commission No.�ti'tCkCX:SZ�FJ (Seal) Commission NoGI9d (Seal) REVIEWS FRONT ZONING SUPERVISOR PLANS VEGETATION SEA TURTLE MANGROVE COUNTER REVIEW REVIEW REVIEW REVIEW REVIEW REVIEW DATE RECEIVED DATE COMPLETED Rev.8/2/17 Designed to reduce first stage pressure of 5 to 20 PSIG down to Winer pressure, normally 11' w.c. Ideal for medium commercial installations, multiple cylinder installations and normal domestic loads. Large vent helps prevent blockage and has 4" F.NPT for vent piping. • With 15 PSIG inlet pressure, regulator is designed to not pass more than 2 PSIG with the seat disc removed. Incorporates integral relief valvas. Replaceable valve orifice and valve seat disc. Straight line valve closure reduces wear on seat disc. Unique bonnet vent profile minimizes vent freeze over when - propedy installed. • Large molded diaphragm is extra sensitive to pressure changes. Built in pressure tap has plugged 1W F.NPT outlet Plug can be removed with a 3/10" hex alien wrench. Select brown finish. Mounts directly to house line piping. Eliminates need for union joints, elbows, and mounting brackets. Quick and easy to install. LV4403S 3W i 1W, ................. _..... ..... Die Cast Zinc et.....__ ........ .._......................... ............... I............ Die Cast 2mc leOffice ... flce..... .......... _........... ............ ................................. Brass ring. . __ .. ...-.......................................................................... Steel aNe Seat Disct..........................._......................... Resilient Rubber Diaphragm ... ... _........... ....... Integrated Fabric and Synthetic Rubber. Series LV44P313 %s t.V44s564(6 %' F. NPT 1p28 Drill 11" w.c. at 10 PSIG LV44os64sR` F. NPT Inlet V44a3B86 /" F. NPT LV4463a66R` `Backmpuntdmp ^Maximum Mw basetl on 10 PSIG inlet end 9" •x.c. tlelivery pressure. e r ar e n r 2W,L00 5ogn - 75D,CW 1,LCO,CfA ,Coo LV44403BR 9" to 13"w.c. I Over Inlet I 935,000 A yG 100 Rego Dc Pa. Box 24T Son. NC 2T244 USA �Mgopmductssom Phune (3301 W9-T107 Fax (3361 ta9-6594 J Application Materials Ideal for use as a first stage regulator on any domestic size ASME or DOT container in propane gas installations requiring up to 1,500,000 BTU's per hour. The regulator is factory set to reduce container pressure to an intermediate pressure of approximately 10 PSIG. Features Compact design can be connected to a service valve using either a POL adapter or a RegO product pigtail. Large threaded''/a" ENPT bonnet vent can easily be piped -away underground installations without the need of glue kits or extra adapters. • Non Adjustable Large tiow, orifice resists freeze ups due to water concentration in LPG vaper. Design provides for good flow regulation at both high and low container pressures. Built In relief valve and travel stop comply with NFPA 56 over pressure requirements. Incorporates'/" F.NPT downstream pressure tap for an easy inlino check of the regulator's delivery pressure. Molded diaphragm provides an o-ring type seal between the body and bonnet. Body and bonnet are assembled in the USA using the unique, patented RegUlok seal system_ Fully painted in brilliant red for complete corrosion protection. Mounting bracket available as an accessory: part number 2302-31. 3.56" Ordering information Body Zinc Zinc Spring.......................... .....------- ---- seat Disc ..... ........... .....- ............ _.......... ....,.............. Resilient Rubber Diaphragm ...... ........ .._....., integrated Fabric and Synthetic Rubber arvmr. sai bo" ,;"a, +me.aoo Vbvp4o Lsaana I'M= FLOW PROP"s - Le.l»uo n. • Maximum flow based an inlet pressure ZO PSIG higher lhen the regulator seging and delivery pressure 2g°h (.war than theregulaloisetEng anddelivary pressure 20%lower Ihan this selling. A14 p® ape ftag0 pr. P.O. aax 24T Elon, NC 2T244 U6A www.regopmducts.cam Phyre (33fi) W9-7707 Fax r3361449-6694 H..f- any fom�pennNedv'NvutwriBen pemJaivv vlNFPA For ingWresur l mpatlan it iv'. evneunw ..nm . Chapter 15 • Pipe and Tubing SlAng Tables TABLE 15.1(o) Polyerhvlene Plastic Prpe S1'9t8 Between First Stage and Second -Stage Regulators: Nominal Outside Diameter (1PSj Gas, U), led Propane rn&t Pressure:psi Pressure Drop: 1.0 psi 1pe¢ifteGravity: I L52 Matic Pipe `h in_ 314 in, 1 in. in. 1'L• in, 2 in. Length SDR 9.33 SDR I1.0 SDR Me SDR 10,00 SDR 11.00 SDR 11.00 UU (0.660) (0.860) (1.078 (1,328) (1.554) (1.943) 1...30 2143 4292 7744 13416 20260 36402 40 1835 3673 6618 11482 J7340 31155 50 1626 3256 5874 10176 15369 27612 60 1473 2950 5322 9220 13924 25019 70 1355 2714 4896 9483 12810 23017 80 1261. 252.5 4555 7991 11918 21413 90 1193 2369 4274 7404 11182 20091 t00 1117 2239 4037 6994 10562 19978 125 990 1993 3578 6199 9361 16820 150 897 1797 3242 5616 8482 15240 175 826 1653 2983 5167 7803 14020 -0-----775-----4539 ------47-T5.. dRa7 7259 13043 225 721. 1443 2603 4510 6811 12238 250 681 1363 2459 4260 64.14 11560 275 646 1294 2336 4046 6111 10979 300 617 1235 2228 3960 5830 10474 350 567 1136 2D50 3551 5363 9636 . 400 528 1057 1907 3304 4989 8965 450 495 992 1789 3100 4681 9411 500 468 937 1690 2928 4422 7945 600 424 849 1531 2653 4007 7199 700 390 781 1409 2441 3686 66D 800 363 726 1311 2271 3429 6161 900 340 682 1230 2131 3217 5781 '5461 10D0 322 644 1162 2012 3039 1500 258 517 933 1616 2441 4385 2000 221 443 798 1383 2089 3753 1pS: Iran pipe size. SDR: Stendud dimension ratio - - Notes: il)Capa6des are in 1000 ffiu/lu. (2) Dimensions in puemheses are inside diameter. 2014 LP -Gas Code Handbook r� 2' VA1E.Y GUTTER (TYPICAL) y� II.~j � Ls' I'y a I z_a ''3 LOT 11 SCALE 1"=30' la Iw-v I\ E=101.86' mzc EK � N ! pELI S89°18'04"E a J�; ' try I 165,00' ao/ y 3 OVCR -- IS. O' —q"-- 8.0' W PPODOSED __ EfN ,4 �_ � 26.C' --- CO16' DRIV� 'I _o S00°41'56W f 10 " ( �' =— —J— LOT 12 s r i 50.00' i c 28.T °r�61 OS J o 0 Lo r, RFSJPFWCt_�/� v ri PROPOSED 00 '2.0 51:8'_._ i0.0O' --25 8T7, `r Ca 65.00' � a �Z) I J /It f y LOT 13FQ iye rVACANT) LOT 14 1C'..73' LEGEND -CALCULATPED ' f POSITION � � � ) b CEN. ,AL ANGLE R CURVE RADIUS L ++ CURVE v CALCULATED CERTIFIED TO: = PLAT ME FOUND FRANCIS S. CISHOP AR,) , '"., A, S,FHOE :R = 5/8" IRON ROD Ill = /2" IRON PIPE DHU = OVERHEAD UTLITIE5 DESCRIPTION `dB TOP OF BANK (J,KE) 'fE FINISH FLOOR ELEVAUON LOT 12, THE ^;IOV'.- ,` N TIER WOODS, AGCCRDING TO 'NE PLAT T,NEREO:-, AS RECORDED PKo :.: PK NAIL AND DISK IV P'_AT. BOOK AO PAGE 5l 7H THE PIJBUC RECORDS OF ST. LUCIE COUNTY, FLORIDA. P.L& - PROFESSIONAL LAND SURVEYOR 1 a = LICENSED BUSINESS P.B. = PLAT BOOK SAID LAND C"N?AIMS 1.19 ACRES, MORE OR LESS. Rjtq = RIGI!L_gp_SVAY SURVEY NOTES CD-S,'L d = AT&TATST PED'snt. 1. Thls serve_; is r,ci Valk withaui a signoture and original embossed seal of O Peron = WATER METER P.ro'Besional L and Surveyor. 2. Descrptin"l provided by client and/or their agent. `� =WOOD PODIER POLE t T. e I- s e Of field ward. was (December 20, 2018. Q= FOUND IR (NO IC) ' " UndergroUrn r,provemenfs and foundotior.s were not-ocatcd as part of this c= CCNORETE !Be e RN- INA ROD h RAP o. Sear.ngs snc,a+n herecn ere based on the East ',R/AJ line of Grave Court, bur. eor'surveY' ng D... = DRAmncE AND unLlEv enserwE:vr as rnonumented. All bearings are relat've €hereto. -x-= 6' M-e FENCE a. All bOundury 'rformatlo , shown is calculated per plat, unless otherwise: shown. 0 BAHLE. TELEVISION PDX I 7. Property lies in flood zone "X", per man 12111C01ED J. dated 2-1D-12. '�14 =FIRE HYDRANT 8. .4ddi tors a- deletions to survey maps or reports by other than the signing party or . par ies 's proh bltcd without written con Rent of the signing purl y or ParE'DQ - WA -,ER VALVE g 9 .d=. NSLRMD NORDH T. LUCIE RIPER WAIER �. AIi 3Ie V0'.Ian+ Shavtn CIO Cased on on assumed datum. CONTROL OBTRICT j Americas is pleased -to -offer thefollowingproposal foryourconsideration; Fran Bishop Bruce Cobedy sales Representative 3608.Grove Court 5trest Fort Pierce, F134951 city, State, Zip Code Description of work: Connect new generator to existing gas system Ft. Pierce District Location 772-971-6092 Telephone Quantity Description Unit Cost Total �[Dispatch .. xl ,�_Requlatqrventingi} . Ir 4 . se scopper �[ • .: • tank tie in All prices am exclusive of any applicable taxesi plumbing and electrical vmrk. All prices are based on a standard installation. Unforeseen circumstances such as poor soill condition, premature Installation of ooncrete, landscaping, sherrhock etc may reault In increased costs. Change orders must be approved poor to installation and are subject to approval by the authority having jurisdiction. Attie G s tariff not be resoonsibie for damage to ginmarked tines tsorinkior water alecfrio etc 1. ALL WORK SHALL BE PERFORMED ACCORDING TO FEDERAL, STATE ,AND LOCAL REQUIREMENTS. Designed to reduce first stage pressure of 5 to 20 PSIG down toqte ..._.---••.•---•-•-•-�-•••-••••--•••-"""......._...._.... Die Cast=inc burner pressure, normally fi" w.c. Ideal for medium commercial installations, .....:..............._............... Die Cast2mc Bross installations, multiple cylinder installations and normal domesticDdflce .••••._loads. 'SeatDiscregm .._.._......_..-.-._- Integ[ated Fabric and Synthefic Rubber. Large vent helps prevent blockage and has u" FNPT for vent piping. With 15 PSIG -inlet pressure, regulator is designed to not pass more than 2 PSIG with the seat disc removed. Incorporates Integral relief valves. • Replaceable valve orifice and valve seat disc. straight line valve closure reduces wear on seat disc. Unique bonnet vent profile minimizes vent freeze over when properly installed. Large molded diaphragm is edra sensitive to pressure changes. Built in pressure tap has plugged 1/8" F.NPT outlet Plug can be removed with a 3/I6" hex alien wrench. Select brown finish. Mounts directly to house line piping. Eliminates need for union joints• elbows, and mounting brackets. Quick and easy to install. LV4403B 3r1K„ Series IBM------� —ma's —�,__ 50 29O131 5 ow 250 75..3350 1,� CW 1.7� OCO 044e36B iV44P384/z" L '(463646 'F=" F NPT It28 Drill 11" w.c. at 10 PSIG 9" to 13"w.c. over Inlet 935,000 Lv44a3B4sR` /4 F NPT Inlet Lv46s3B66 /" F. NPT LV44FISH66K` ` Ssaluaeunt design ^ Narlmum a.. based on 16 PSIG inlet and 9" x.c. delivery pressure. * aC 11, Rego 0[ P.O. eoz 247 Elan. NC 2T US0. •wrccregopmdu O.ccm Phone (396) 949-M7 Fax (33%U9-6694 Application Materials Meal fir use as a first stage regulator on any domestic site ASME or DOT container in propane gas installations requiring UP to 1,500,000 BTU's per hour. The regulator is factory set to reduce container pressure in an intermediate pressure of approximately 10 PSIG, Features Compactdesign can be connected to a service valve using either a POL adapter or a RegO product pigtail Large threaded''/.' F.NPT bonnetvent can easily be piped -away underground installations' without the need of glue We or extra adapters. Non Adjustable Large thaw orifice resists freeze ups due to water concentration in LPG vapor. . Design provides for good flow regulation at both high and low container pressures. Built in relief valve and travel stop comply with NFPA 58 over Pressure requirements. Incorporates;'/" PNPT downstream pressure tap for an easy inline check of the regulator's delivery pressure. Molded diaphragm provides an o-ring type seat between the body and bonnet Body and bonnet are assembled in the USA using the unique, patented RegUlok seal system. Fully painted in briliiant red for complete corrosion protection. Mounting bracket available as an accessory: part number Z302-31. - Ordering information ..................._...................... .2mc Bo .........:.... .. ........._. Zinc gannet...... ....... . ..... ................. ..... ............. .......... Spring..............- ............. ........................_....Steel Seat Mae-- . . ......... 11— ............. .......... .,...... .... ....Resillent Rubber Diaphragm ...... ....._.,......._. Integrated Fabric and Synthetic Rubber rz u an W •"" y5y av asv.nva W.mo mmv wa, a,mvAao t A FLOW ?"PANE W5403TR. Over uuue[ 1,500,000 l.Va4osTRvS �' F NPT %" F NP7 %" 10 PSIG g 00 end depVs assure 2p%fawerlhan the regulabsethng and del 6P 2g".b Ih N mg Megmum fiuw eased an lntst pressumza PSIG higher than the mguhaor seging hP A14 100 Rego pr. P.o: apt 247 FJaM1 NC 212M USA www.rcgopmduc6.com PM1ge(]36t W9-]]O] fa. 1336}Yra-8596 CepyryM2016 NAtlnuinm Pmmdon Aesamam{nrrn).rxenseo, ey agreement. Wh3do,01111e ena tlownloee on Moof,u, aoo'' me,anenamnaeyesvrvd•y any rmm pmmflmewithout mitlen pemasdan or NFPA For ingWme or 0 mpod en�Jv Chapter 15 - Plpe and iUbing Suing Tables TABLE 15.1(o) Potyerhptene piasfic pipe 517"g letween First Stage and Serand-Stage Regulators: Nominal Outside Diameter (1PS) Gas: Undrluteditpane inktpressure: MOO Pressure Drop: 1.0psi Jpetific Gravity: 1.52 _ Pksik Pipe 54 in. rl in: I in 1% tn. 2% in, 2 irt. Length SDR 9.33 OR 11.0 SDR 110 SDR10,00 SDR 11.00 SDR 11.00 (jt) (0.660) (0.860) (1.078 (1.328) (1.554) (1.943) 40 2143 4292 7744 13416 20260 36402 40 1835 3673 6628 11482 1.7340 31155 50 1626 3256 5974 10176 15368 27612 60 1473 2956 5322 9220 13924 25019 70 1355 2714 4896 8483 12810 23017 80 1261. 2525 4555 7891 11918 21413 90 1193 2369 4274 7404 11182 20091 100 1117 2238 4037 6994 10562 18978 125 990 1993 3578 6199 9361 16820 150 897 1797 3242 .5616 8492 15240 175 826 1653 2983 5167 7803 14020 ©0----778 ---�339 ----- 5- 2603 4907 4510. 7259 6811 13M _. 12238 225 250 721 691 1443 1363 2459 4260 6434 11560 275 646 1294 2336 4046 6111 10979 300 617 1235 2228 3860 5830 10474 350 567 1136 2050 3551 5363 9636 400 528 1057 1907 3304 4999 9965 450 495 992 1789 3100 4681 8411 500 468 937 1690 2928 4422 7945 600 424 84-9 1531 2653 4007 7199 700 390 781 1409 2441 3686 6623 900 363 726 1311 2271 3429 6161 900 340 682 1230 DR 3217 5781 '5461 1000 322 644 1162 2012 3039 1500 258 517 933 1616 2441 4385 2000 221, 443 798 1383 2089 3753 IpS: Iran pipe size. SDR: Staadazd dlmOmian rado Notes: I1) Capacides are in 1000 S{uA r. (21 Dimensions in Parenlbesm are inside diaureler. 2014 LP -Gas Code Handbook N 2', VALLEY GUTTFR ` (TYP7GAL) W r E S LOT 11 SCALE 1 °=30' za no w�0 1n S89°18'04"E floL st i 165Mr �8 � f� -OVURFC A.O'y�-- :�f �. d PROPOSED L, y ?r ^ Ivr. I �.O'co ! l�� j i Lin CD i-r 2,.0' '= f SQQ°41'36"`y1( _ 0 / �. o 2�� LOT 12 50M' of I i IJ Ln R GIG^.. `t 72.OFFE . 1.82' SG OO' --25 N89" r n g 3 .14J. L`J` O bl 'i 9 j01 U LOT 13 (F C� yX J Ci LOT i4 ! Yti. �p� Ff= rs' LEGEND r�t'SI iQr.(- - )` d CENTRAL ANGLE \% R CURVE RADIUS CURVE 1_",,S. (Oj CALCULATED FRANCIS S. cIS ,UNO A. 3-iNOP ENa R 5j8" IRON ROD iiP 1/V IRON PIPE D[` (('"'}} CHU = OVERHEAD UT, E S V R 1 i I V N. 703 = 'raP OF DANH ('_A<E) =FF = FINISH FLOOR ELEVAMN LOT to i_,E FCb. -1ER Vi00•'S ACCCROING TO THE PLAT h'EREOr AS RECORDED PKO - rK NAIL AND DISK IN P• K.^.K ? a, fHE ?U3LIC RECORDS OF S L'JCIE COUNTY, FLORIDA. LS = '.ICENSED BUSINESS P.L.S. = PROFESSIONAL '-AND SURVEYOR SAID LAND CC`iTA'sN5 u. 13 ACRES, MORE OR LESS. P.S. = PA- BOOK Raw = RIG+T-aF-WAY SURVEY NO ES =ELECTRIC SERMCE d - ATST PC IS rAL 1 Ih s -' Q'. valid ithau-i a signature and orginci embossed seal of a Fordo ?-Sslorr. c Survey..,. NSt' = WATER METER 2. Descr!a Ec-: Iorcvided by client and/Or their agent °L: ='WOOD POWER POLE 3. The 'nodole of field- work was Docemoer 20, 2018, Q = FOUND iR (No ID) a Uncerc,orlric npruvements ono foardotier.s were not located as part of this survey. CONO CONCRETE 5 ae ng'= wl hereon ere bused en the Cos: 2f;'J line of Grave Ooart, oearn Rc gs IRr.N Roc v OAP M1DC E - g D.L •= DRAINAGE AND UT ITY EASEME` a C `Dlonum rted. All bearngs are rely%iv `sereto. X - 6' `AN°_PENCE S. All 3ourila y crorma-Ior, shown Is o:cu ated per O'Dt, unless otherwlsc: shown. 0 CAe : TrucrosfON Box ? Prolperity ! es in flood zone "X" per mop 1211100160 J, dated 2-15-12. = PRE HYDRANT 8 Ado c- r, or deict'OnS tO survey maps or reports by Other %hon the sic .r.0 party or part es is prohibited without wrhter con=_er.t of the sighing Carty or 'NnTER VALVE g g y purl"" :NSLRWC NORi S� _UCIF RIV,H 'HATER 9 All .. ovations shown re „used an an assemed datum.CONT.Rat. DSTRrC'r A AmeriGas is pleased to offer the following proposal for your consideration: Fran Bishop 3608 Grove Court, Street Fort Pierce, FI 34951 City, State, Zip Code - I - Bruce Cobedy Sales Reptesentative Ft. Pierce District Location 772-971-6092 Telephone description of work Connect new generator to wdsting gas s stem . Unit Cost Total tauantity 69.99 _ $r59.99 1 Dispatch 1 Gas hook- 75 $75.00 1 R ulator 56 $55 00 1 R ulatorventln material 75 $75,00 1 Hard riser 45 $90.00 2 314 trans poly to copper 2 $$00 1 Minimum line installation and tank tie in 25 2525-00 . 1 Shut off5 250 $250:00 1 Permit 7.00% $74., R TAX - .._... TOTAL COST $1,136.46 Ail piit wv W[41u.1 . u, a»Y All prices are based on a standard installation. Unforeseen circumstances such as poor soil condition, premature Installation of concrete, landscaping, sheetrock etc may result in increased costs, Change orders mustbe approved prior to installation and are subject to approvel by the authority having jurisdiction. ArneriGas wfff not be resoonsfixte for damage M unmarked lines t`sadnkfer water etectdc etc•} . ALL WORE{ SHALL BE PERFORMED ACCORDING TO FEDERAL, STATE AND LOCAL REQUIREMENTS. M lid for 30 days from the date submitted. Date 614M20