HomeMy WebLinkAboutMobile Home Inspection ReportSt Lucie County Building & Zoning
2300 Virginia Avenue
Ft Pierce. FL 34982
Mobile Home Inspection Report
All requests for permits to place or replace used Mobile I Manufactured homes must be accompanied by this
completed Inspection Report and copies of both sides of the Title to the home.
All used Mobile homes must be Wind Zone 11 certified.
Owner:
Address:
Year / ME
J;�?R&E prRELLZ
(Print or type)
Date: 3"690?0d0
-L 319,q%
Fca3lt0&7
HUD Plate # %LA 31 o&(o
t
Width_ Length �D Single Double_ Wind Zone_
C = In Compliance N = Not in Compliance
Fire Safety / Electrical
C 1. Smoke Detector: Installed Missing
(l 2. Electrical System Checked: Exposed Wiring _Other
_1!, 3. Distribution Panel: Missing Loose_ Main Missing_ Breaker Missing_
Unplugged Opening Other_
4. Electrical Fixtures: Missing Installed Improperly
Improperly Wired Loose Wire_
GFCI receptacles not where required_
5. Electrical Ground: Chassis Main Panel Gas Pipe
Revised 3/9/05
Page I of 3
Construction
C 1. Exit Doors Operable:
2. Exit Door Locks: Missing Inoperable
S` 3. Egress windows: Missing Inoperable
4. Windows: Broken Glass Inoperable
5. Screens: Missing Damaged
6. Floor System: Joist Decking Area Damaged
_ 7. Interior Paneling: Missing _ Loose _ Damaged_
ii 8. Rodent Proofing: Bottom Board —Pipe openings_ Other
�L 9. Leaks Apparent: Ceiling Doors_ Floor _ Roof _
G 10. Vertical tie -down straps: Missing _ Short _ Damaged_
Ci 11. Structural modifications since manufactured: YES_ NO-[
S� 12. Walls: Structurally Unsound _ Loose _ Weather tight
Plumbing
1. Trap: Missing Not connected Other
G 2. Plumbing fixtures: Missing _ Not installed _ Not Vented
3. Relief Valve: Missing Inoperable Other
ii 4. Drain Waste and Venting Piping: Missing _ Not supported_
Clean outs _ Use of fittings _ Not capped_
Heating and Air Conditioning
G 1. Heating Appliances: Missing Not Connected Other A
�L 2. Deleted Heating/AC system: Not installed Other ci
41
3. Thermostat: Missing Inoperable v
4. Air registers: Missing Inoperable
Ci 5. Ducts: Not sealed Missing Collapsed
Page 2 of 3
_C 6. Gas furnace Water heater vent: Missing
�L 7. Return Air: To Furnace To A/C
8. Range: Vent Hood
Loose
From rooms
_C— 9. Gas Valve: Accessible Installed improperly
G 10. Gas lines: Not capped Not supported Kinked
Not bonded
Summary
1. Is subject structure found to be fifty (50%) or more damaged or deteriorated? YES NO
2. Willa remodeling permit be required? YES NOS/
The provisions of the repair and remodeling code shall ensure safe and livable housing and shall not be more stringent
than those standards required to be met in the manufacture of mobile homes. Such provisions shall include, but not be
limited to, standards for structural adequacy, plumbing, heating, electrical systems, and fire and life safety. FS 320.8232
IF ANY RENOVATIONS OR IMPROVEMENTS OVER AND ABOVE THE REQUIREMENTS OF FS 320.8232 ARE TO
BE PERFORMED ON ANY MOBILE HOME WHICH WILL BE PERMITTED TO BE TIED -DOWN IN ST. LUCIE COUNTY,
A SEPARATE PERMIT WITH ENGINEERING (IF APPLICABLE) WILL BE REQUIRED. ALL SEPARATE PERMITS
MUST OBTAIN A FINAL INSPECTION BEFORE A FINAL INSPECTION IS OBTAINED FOR THE TIE -DOWN PERMIT. Q
NO MOBILE HOME WILL BE ALLOWED TO BE MOVED TO ST. LUCIE COUNTY OR RE- Cii
LOCATED WITHIN ST. LUCIE COUNTY UNTIL THE REQUIRED DOCUMENTS HAVE BEEN
SUBMITTED, REVIEWED, APPROVED AND THE TIE -DOWN PERMIT HAS BEEN ISSUED.
A REGISTERED FLORIDA PROFESSIONAL ENGINEER MUST COMPLETE THIS DOCUMENT, SIGN AND AFFIX
Date inspected: 3 LIO L; 0 9 V
Inspected By:
�,__ Sign ura npulred
Phone Numberma )
THEIR SEAL.
License# 3'f3�8 3/jO�aoao
Englneero Seal
Page 3 of 3 STEVEN G. WOOD, P.E.
FL LICENSE 34398
960 SULTAN DR
pORT ST LUCIE, FL