HomeMy WebLinkAboutMobile Home Inspection ReportSt Lucie County Building & Zoning 2300 Virginia Avenue Ft Pierce. FL 34982 Mobile Home Inspection Report All requests for permits to place or replace used Mobile I Manufactured homes must be accompanied by this completed Inspection Report and copies of both sides of the Title to the home. All used Mobile homes must be Wind Zone 11 certified. Owner: Address: Year / ME J;�?R&E prRELLZ (Print or type) Date: 3"690?0d0 -L 319,q% Fca3lt0&7 HUD Plate # %LA 31 o&(o t Width_ Length �D Single Double_ Wind Zone_ C = In Compliance N = Not in Compliance Fire Safety / Electrical C 1. Smoke Detector: Installed Missing (l 2. Electrical System Checked: Exposed Wiring _Other _1!, 3. Distribution Panel: Missing Loose_ Main Missing_ Breaker Missing_ Unplugged Opening Other_ 4. Electrical Fixtures: Missing Installed Improperly Improperly Wired Loose Wire_ GFCI receptacles not where required_ 5. Electrical Ground: Chassis Main Panel Gas Pipe Revised 3/9/05 Page I of 3 Construction C 1. Exit Doors Operable: 2. Exit Door Locks: Missing Inoperable S` 3. Egress windows: Missing Inoperable 4. Windows: Broken Glass Inoperable 5. Screens: Missing Damaged 6. Floor System: Joist Decking Area Damaged _ 7. Interior Paneling: Missing _ Loose _ Damaged_ ii 8. Rodent Proofing: Bottom Board —Pipe openings_ Other �L 9. Leaks Apparent: Ceiling Doors_ Floor _ Roof _ G 10. Vertical tie -down straps: Missing _ Short _ Damaged_ Ci 11. Structural modifications since manufactured: YES_ NO-[ S� 12. Walls: Structurally Unsound _ Loose _ Weather tight Plumbing 1. Trap: Missing Not connected Other G 2. Plumbing fixtures: Missing _ Not installed _ Not Vented 3. Relief Valve: Missing Inoperable Other ii 4. Drain Waste and Venting Piping: Missing _ Not supported_ Clean outs _ Use of fittings _ Not capped_ Heating and Air Conditioning G 1. Heating Appliances: Missing Not Connected Other A �L 2. Deleted Heating/AC system: Not installed Other ci 41 3. Thermostat: Missing Inoperable v 4. Air registers: Missing Inoperable Ci 5. Ducts: Not sealed Missing Collapsed Page 2 of 3 _C 6. Gas furnace Water heater vent: Missing �L 7. Return Air: To Furnace To A/C 8. Range: Vent Hood Loose From rooms _C— 9. Gas Valve: Accessible Installed improperly G 10. Gas lines: Not capped Not supported Kinked Not bonded Summary 1. Is subject structure found to be fifty (50%) or more damaged or deteriorated? YES NO 2. Willa remodeling permit be required? YES NOS/ The provisions of the repair and remodeling code shall ensure safe and livable housing and shall not be more stringent than those standards required to be met in the manufacture of mobile homes. Such provisions shall include, but not be limited to, standards for structural adequacy, plumbing, heating, electrical systems, and fire and life safety. FS 320.8232 IF ANY RENOVATIONS OR IMPROVEMENTS OVER AND ABOVE THE REQUIREMENTS OF FS 320.8232 ARE TO BE PERFORMED ON ANY MOBILE HOME WHICH WILL BE PERMITTED TO BE TIED -DOWN IN ST. LUCIE COUNTY, A SEPARATE PERMIT WITH ENGINEERING (IF APPLICABLE) WILL BE REQUIRED. ALL SEPARATE PERMITS MUST OBTAIN A FINAL INSPECTION BEFORE A FINAL INSPECTION IS OBTAINED FOR THE TIE -DOWN PERMIT. Q NO MOBILE HOME WILL BE ALLOWED TO BE MOVED TO ST. LUCIE COUNTY OR RE- Cii LOCATED WITHIN ST. LUCIE COUNTY UNTIL THE REQUIRED DOCUMENTS HAVE BEEN SUBMITTED, REVIEWED, APPROVED AND THE TIE -DOWN PERMIT HAS BEEN ISSUED. A REGISTERED FLORIDA PROFESSIONAL ENGINEER MUST COMPLETE THIS DOCUMENT, SIGN AND AFFIX Date inspected: 3 LIO L; 0 9 V Inspected By: �,__ Sign ura npulred Phone Numberma ) THEIR SEAL. License# 3'f3�8 3/jO�aoao Englneero Seal Page 3 of 3 STEVEN G. WOOD, P.E. FL LICENSE 34398 960 SULTAN DR pORT ST LUCIE, FL