HomeMy WebLinkAbout5V CRIMP PRODUCT APPROVAL6/30/2020
oCIS Home
Florida Building Code Online
.. .or '
i- ;
Log In user Iteg'slrahon Hot'ropics Submit Surcharge I Slats & Fads 1. Publications contact Us I acts Site Map Links 1 Search
(1, Product Approval
USER: Public UserFor
Min.- I b " r
Pmtlud Aooroya Menu > Product or Application Search > Application List > Application Retail
I FL #
. Application Type
Code Version
Application Status
Comments
Archived
Product Manufacturer
Address/Phone/Email
Authorized Signature
Technical Representative
Address/Phone/Email
Quality Assurance Representative
Address/Phone/Email
Category
Subcategory
Compliance Method
FL14645-R3
Revision
2017
Approved
Metal Sales Manufacturing Corporation
545 South 3rd Street, Suite 200
Louisville, KY 40202
(502)855-4300
dstermer@metalsales.us.com
David Stermer
dstermer@metalsales.us.com
Roofing
Metal Roofing
Evaluation Report from a Florida Registered Architect or a Licensed Florida
Professional Engineer
Evaluation Report - Hardcopy Received
Florida Engineer or Architect Name who developed the Bala Sockalingam
Evaluation Report
Florida License PE-62240
Quality Assurance Entity Keystone Certifications, Inc.
Quality Assurance Contract Expiration Date 12/27/2026
Validated By Yoosef Lavi, P.E.
Validation Checklist - Hardcopy Received
Certificate of Independence
Referenced Standard and Year (of Standard)
Equivalence of Product Standards
Certified By
Sections from the Code
FL14645 R3 COI Certlficatelndenendence.[Ldf
Standard
FM 4470
TAS 125
UL 1897
UL 580
Year
2012
2003
2012
2006
https://www.floridabuilding.org/prlpr_app_dti.aspx?param=wGEVXQvvtDgswBZVNfeBA7ecHQhC9itQOtvOK%2fgnu6PmBdDM0IW5HbQ%3d%3d 114
6/30/2020
Product Approval Method
Florida Building Code Online
Method 1 Option D
Date Submitted
Date Validated
Date Pending FBC Approval
Date Approved
09/09/2017
09/14/2017
09/15/2017
12/12/2017
I FL # I Model, Number or Name I Description I
14645.1 2.5" Corrugated I Min. 26 ga., 21.33" wide coverage through fastened roof panel
over min. 19/32" thick plywood deck.
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL14645 R3 II EvaluationReportC2182 1.pdf
Approved for use outside HVHZ: Yes Verified By: Bala Sockalingam PE 62240
Impact Resistant: N/A Created by Independent Third Party: Yes
Design Pressure: +N/A/-86.0 Evaluation Reports
Other: Uplift load of 82.3 psf at fastener spacing of 36" o.c. FL14645 R3 AE EvaluationReportC2182 1. pdf
and 86.0 psf at fastener spacing of 12" o.c. Created by Independent Third Party: Yes
t 14645.2 SV-Crimp26 ga., 24 wide through fastened roof panel over min.
..�I 19/32" thick plywood deck with fasteners through panel flat.
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL14645 R3 11 EvaluationReo2rtC2182 2.pi f
Approved for use outside HVHZ: Yes Verified By: Bala Sockalingam PE 62240
Impact Resistant: N/A Created by Independent Third Party: Yes
Design Pressure: +N/A/-149.6 Evaluation Reports
Other: Uplift load of 84.5 psf at fastener spacing of 24" o.c., FL14645 R3 AE EvaluationRe0ortC2182 2.pdf
131.3 psf at fastener spacing of 18" o.c. and 149.6 psf at Created by Independent Third Party: Yes
fastener spacing of 12" o.c.
14645.3 5V-Crimp Min. 26 ga., 24" wide through fastened roof panel over min.
19/32" thick plywood deck with fasteners through panel rib.
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL14645 R3 II EvaluationReportC2182 3.pdf
Approved for use outside HVHZ: Yes Verified By: Bala Sockalingam PE 62240
Impact Resistant: N/A Created by Independent Third Party: Yes
Design Pressure: +N/A/-196.75 Evaluation Reports
Other: Uplift load of 41.6 psf at fastener spacing of 36" o.c., FL14645 R3 AE EvaluationReportC2182 3,Pjj
74.8 psf at fastener spacing of 16" o.c. and 196.75 psf at Created by Independent Third Party: Yes
fastener spacing of 8" o.c.
14645.4 1 5V-Crimp
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: +N/A/-172.5
Other: Uplift load of 30.0 psf at fastener spacing of 36" o.c.
and 172.5 psf at fastener spacing of 6" o.c.
Min. 26 ga., 24" wide through fastened roof panel over min.
15/32" thick plywood deck or 7/16" thick OSB with fasteners
through panel rib.
Installation Instructions
FL14645 R3 II EvaluationReportC2182 4.pdf
Verified By: Bala Sockalingam PE 62240
Created by Independent Third Party: Yes
Evaluation Reports
FL14645 R3 AE Evaluation Rep2rtC2182 4. pdf
Created by Independent Third Party: Yes
14645.5 i Aluminum Classic Rib Nord. 0.032" thick, 36" wide, aluminum through fastened roof
panel over min. 15/32" thick plywood deck or 7/16" thick OSB.
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL14645 R3 11 EvaluationReportC2182 5.pdf
Approved for use outside HVHZ: Yes
Verified By: Bala Sockalingam PE 62240
Impact Resistant: N/A
Created by Independent Third Party: Yes
Design Pressure: +N/A/-120
Evaluation Reports
Other: Uplift load of 30 psf at fastener spacing of 36" o.c. and
FL14645 R3 AE EvaluadonReportC2182 5.p iff
120 psf at fastener spacing of 6" o.c.
Created by Independent Third Party: Yes
14645.6 Aluminum Vertical Seam I Nom. 0.032" thick, 16" wide, aluminum standing seam roof
panel over min. 15/32" thick plywood deck or 7/16" thick OSB.
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL14645 R3 II EvaluationReportC2182 6.pdf
Approved for use outside HVHZ: Yes Verified By: Bala Sockalingam PE 62240
Impact Resistant: N/A Created by Independent Third Party: Yes
Design Pressure: +N/A/-97.05 Evaluation Reports
Other: Uplift load of 41.6 psf at clip spacing of 36" o.c., 71.0 FL14645 R3 AE Evaluation ReportC2182 6.pdf
psf at clip spacing of 12" o.c. and 97.1 psf at clip spacing of 12" Created by Independent Third Party: Yes
o.c, with sidelap adhesive.
https://www.floridabuilding.org/prlpr_app_dtl.aspx?param=wGEVXQvADgsw8ZVNfe8A7ecHQhCgitQOtvOK%2fgnuBPmBdDM0IW5HbQ%a3d°/3d 2/4
EVALUATION REPORT OF
METAL SALES MANUFACTURING CORPORATION
`26 GA. 5V-CRIMP PANEL'
FLORIDA BUILDING CODE 6TH EDITION (2017)
FLORIDA PRODUCT APPROVAL
FL 14645.2-R3
ROOFING
METAL ROOFING
Prepared For:
Metal Sales Manufacturing Corporation
545 South 3rd Street, Suite 200
Louisville, KY 40202
Telephone: (502) 855-4300
Fax: (502) 855-4200
Prepared By:
Bala Sockalingam, Ph.D., P.E.
Florida Professional Engineer #62240
1216 N Lansing Ave., Suite C
Tulsa, OK 74106
Telephone: (918) 492-5992
FAX: (918) 493-3568
This report consists of
Evaluation Report (3 Pages including cover)
:Installation Details kinage)
�teLtl1Oli1xs
Sp C K.4
y No 62240 •�,
� '}sj' • s � .r
�: STATE OF 44'
.M
d�
•
f � . ,
,,,g s �13
-7
Report No. C2182-2
Date: 9.9.17
FL 14645.2-R3
C2182-2
9.9.17
Page 2 of 3
Manufacturer: Metal Sales Manufacturing Corporation
Product Name: 5V-Crimp
Panel Description: 24" wide coverage with (5) 1/2" high ribs
Materials: Min. 26 ga., 50 ksi steel. Galvanized coated steel (ASTM A653) or
Galvalume coated steel (ASTM A792) or painted steel (ASTM A755).
Deck Description: Min. 19/32" plywood or min. 3/4" thick wood plank (min SG of 0.42)
for new and existing constructions. Designed by others and installed
as per FBC 2017.
Deck Attachment: 8d x 2.5" long ring shank nails or #8 x 2" long wood screws @ 6" o.c.
(Minimum) in the field and edges. Designed as per FBC 2017.
Underlayment: Minimum underlayment as per FBC 2017 Section 1507.4.5.1
Slope: 1/2:12 or greater in accordance with FBC 2017 Section 1507.4.2.
Requires applied lap sealant for roof slopes less than 3:12.
Design Uplift Pressure: 84.5 psf @ fastener spacing of 24" o.c.
(Factor of Safety = 2) 131.3 psf @ fastener spacing of 18" o.c.
149.6 psf @ fastener spacing of 12" o.c.
Fastener Pattern:
Type: #9-16 or # 10-14 hex head wood screws with sealed washer. Fastener
shall be of sufficient length to penetrate through the deck a minimum
of 3/8".
At panel ends 6 fasteners per panel width. (4 located adjacent to ribs and 2 between
ribs)
At intermediate 4 fasteners per panel width. (4 located adjacent to ribs)
Test Standards: Roof assembly tested in accordance with TAS 125-03 `Standard
Requirements for Metal Roofing Systems' .
Code Compliance: The product described herein has demonstrated compliance with FBC
2017 Section 1507.4
Product Limitations: Design wind loads shall be determined for each project in accordance
with FBC 2017 Section 1609 or ASCE 7-10 using allowable stress
design. The maximum fastener spacing listed herein shall not be
exceeded. This evaluation report is not applicable in High Velocity
Hurricane Zone. Fire classification is not within scope of this
Evaluation Report. Refer to FBC 2017 Section 1505 and current
FL 14645.2-R3
C2182-2
9.9.17
Page 3 of 3
approved roofing materials directory or ASTM E108/UL790 report
from an accredited laboratory for fire ratings of this product.
Supporting Documents: TAS 125 Test Reports
Farabaugh Engineering and Testing Inc
Project No. T235-07, Reporting Date 7/12/07
Project No. T172-08, Reporting Date 4/29/08
SEE DETAIL t PANEL FASTENER SPACING
5V-CRIMP _ �' - - PER ALLOWABLE PRESSURE
� TABLE ON THIS SHEET.
f
ii
n
t' f
v v
I
T v
L
� PLYWOOD
UNDERLAYMENT SHALL BE INSTALLED
AS PER MANUFACTURER'S INSTALLATION
MIN. 2X_ WOOD RAFTER/JOIST/ G131DELINES
TRUSS AT MAX. 24" O.C.
MINIMUM ATTACHMENT:
8d x 2.5" LONG RING SHANK NAIL
OR #8 x 2" LONG WOOD SCREWS
SPACED 0 6" O.C. IN THE FIELD &
AT PLYWOOD EDGES
19/32" THICK (MIN.)
IN
FASTENER PATTERN AT INTERMEDIATE
LOCATIONS
5V-CRIMP SEE DETAIL 1 24"
Ir
UNDERLAYMENT SHALL BE INSTALLED
AS PER MANUFACTURER'S INSTALLATION
PLYWOOD
MINIMUM ATTACHMENT: 19/32" THICK (MIN.)
as .. 1 r," 1 MY' oiuc CWAKPV KlAu
\—MIN. 2X- WOOD RAFTER/JOIST/ GUIDELINES OR #8 x 2" LONG WOOD SCREWS
TRUSS AT MAX. 24" O.C. SPACED 0 6' O.C. IN THE FIELD &
AT PLYWOOD EDGES
FASTENER PATTERN AT PANEL ENDS
#9-16 OR #10-14 WOODSCREWS
WITH SELF SEALING WASHER AT
MAXIMUM SPACING OF 24" O.C.
UNDERLAYMENT
DETAIL 1
TYPICAL PANEL INSTALLATION X-SECTION
5V-CRIMP
MIN 26 GA.
PLYWOOD
19/32" THICK (MIN.)
ALLOWABLE UPLIFT PRESSURE
FASTENER
SPACING
(IN)
PRESSURE
(PSF)
24
84.5
18
131.3
12
149.6
GENERAL NOTES:
1. ARCHITECTURAL ROOF PANEL HAS BEEN DESIGNED IN ACCORDANCE WITH THE
FLORIDA BUILDING CODE (FBC).
2. ROOF PANELS SHALL BE MIN. 26 GA. (t = 0.017"). EFFECTIVE COVERING
WIDTH OF PANEL = 24".
3. THE ROOF PANELS SHALL BE INSTALLED OVER SHEATHING & STRUCTURE AS
SPECIFIED ON THIS DRAWING.
4. REQUIRED DESIGN WIND LOADS SHALL BE DETERMINED FOR EACH PROJECT. THIS
PANEL SYSTEM MAY NOT BE INSTALLED WHEN THE REQUIRED DESIGN WIND LOADS
ARE GREATER THAN THE ALLOWABLE WIND LOADS SPECIFIED ON THIS DRAWING.
5. ALL FASTENERS MUST BE IN ACCORDANCE WITH THIS DRAWING & THE FLORIDA
BUILDING CODE. IF A DIFFERENCE OCCURS BETWEEN THE MINIMUM
REQUIREMENTS OF THIS DRAWING & THE CODE, THE CODE SHALL CONTROL.
6. RAFTERS/JOISTS/TRUSSES MUST BE DESIGNED TO WITHSTAND WIND LOADS AS
REQUIRED FOR EACH APPLICATION AND ARE THE RESPONSIBILITY OF OTHERS.
a
Ix 0
00
U C'4
z t=O
Wo
tf'
la myoLn
1
wJ co
M,J I
j N
ill �
0
cn-j
1 OF 1